Technology Challenges of Commercial Medical Electron Accelerators

Similar documents
Elekta Synergy Digital accelerator for advanced IGRT

Intensity Modulated RadioTherapy

Elekta - a partner and world-leading supplier

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management

Elekta Infinity Digital accelerator for advanced treatments

S Y N C H R O N Y R E S P I R A T O R Y T R A C K I N G S Y S T E M

The Journey of Cyberknife Commissioning

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

iviewdose Confidence and assurance in dose delivery

Elekta Infinity. Digital accelerator for advanced treatments. Redefining treatment precision, speed and control

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

A Patient s Guide to SRS

Potential conflicts-of-interest. Respiratory Gated and Four-Dimensional Tumor Tracking Radiotherapy. Educational objectives. Overview.

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Protura Robotic Patient Positioning System. for efficiency + performance

Advances in external beam radiotherapy

Mitsubishi Heavy Industries Technical Review Vol. 51 No. 1 (March 2014)

Stereotactic Radiosurgery. Extracranial Stereotactic Radiosurgery. Linear accelerators. Basic technique. Indications of SRS

SRS Uncertainty: Linac and CyberKnife Uncertainties

X-Ray Guided Robotic Radiosurgery for Solid Tumors

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

ADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

Image Guided in Radiation Therapy (IGRT) Chumpot Kakanaporn Med Phys Radiation Oncology Siriraj Hospital

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

IMAGE-GUIDED RADIATION THERAPY

Overview of Advanced Techniques in Radiation Therapy

Intensity-Modulated and Image- Guided Radiation Treatment. Outline. Conformal Radiation Treatment

I. Equipments for external beam radiotherapy

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Quality assurance in external radiotherapy

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

Amendment No. 2. Item No. 2 (Rfx/ Event number )

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Who Should Know Radiation Oncology Coding?

Trajectory Modulated Arc Therapy: Application to Partial Breast Irradiation. Research and development to advance radiotherapy

IORT with mobile linacs: the Italian experience

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Elekta Innovation and Growth. ESTRO 2012 Capital Markets Presentation

Session 17 Practical Implementation of New Technologies in Low-to-Middle Income Countries

Elekta R&D Update 22 January 2015, Utrecht

pat hways Medtech innovation briefing Published: 16 May 2018 nice.org.uk/guidance/mib147

Imaging of Radiation Dose Using Cherenkov Light

Radiotherapy Standards Users Meeting, 1 Dec 2008 Abstracts. New calorimeters Simon Duane, NPL

Global Radiation Therapy Market Report

Managing the imaging dose during image-guided radiation therapy

Dosisverifikation mit Delta 4 Discover während der Behandlung

Sarcoma and Radiation Therapy. Gabrielle M Kane MB BCh EdD FRCPC Muir Professorship in Radiation Oncology University of Washington

typical IMRT fraction time and expand high definition radiotherapy anywhere in the body with the widest range of motion of the

PRECISE, ROBOTIC TREATMENT AS INDIVIDUAL AS EVERY PATIENT

EORTC Member Facility Questionnaire

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

FLUKA Monte Carlo Simulation for the Leksell Gamma Knife Perfexion TM radiosurgery system

ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D.

Institute of Oncology & Radiobiology. Havana, Cuba. INOR

Cyberknife Stereotactic Treatment

Helical Tomotherapy Experience. TomoTherapy Whole Brain Head & Neck Prostate Lung Summary. HI-ART TomoTherapy System. HI-ART TomoTherapy System

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Integrating CBCT into Radiotherapy Verification Protocols

SBRT REQUIRES: STEREOTACTIC BODY RADIOTHERAPY STEREOTACTIC BODY RADIOTHERAPY (SBRT) (SBRT) What s s in a name? Stereotactic Body Radiotherapy

Learning Objectives. Clinically operating proton therapy facilities. Overview of Quality Assurance in Proton Therapy. Omar Zeidan

Hot Topics in SRS: Small Field Dosimetry & Other Treatment Uncertainties. Sonja Dieterich, PhD University of California Davis

pat hways Medtech innovation briefing Published: 24 August 2018 nice.org.uk/guidance/mib157

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

Varian Acuity BrachyTherapy Suite One Room Integrated Image-Guided Brachytherapy

Canadian Partnership for Quality Radiotherapy. Technical Quality Control Guidelines for Gamma Knife Radiosurgery. A guidance document on behalf of:

SOUTHAMPTON UNIVERSITY HOSPITALS NHS TRUST CANCER CARE PHASE 2A+ BUSINESS CASE

Future Therapeutic Developments in Head and Neck Cancer

Rotating and static sources for gamma knife radiosurgery systems: Monte Carlo studies

EXACTRAC HIGHLY ACCURATE PATIENT MONITORING

A new geometric and mechanical verification device for medical LINACs

Is dosimetry of multiple mets radiosurgery vendor platform dependent? Y. Zhang

Case Study. Institution Farrer Park Hospital

Dose rate response of Digital Megavolt Imager detector for flattening filter-free beams

Implementation of advanced RT Techniques

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

Radiosurgery by Leksell gamma knife. Josef Novotny, Na Homolce Hospital, Prague

National Institute for Health and Clinical Excellence. Health Technology Appraisal. IIntensity modulated radiotherapy for prostate cancer

Radiotherapy What are our options and what is on the horizon. Dr Kevin So Specialist Radiation Oncologist Epworth Radiation Oncology

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Precisely Maximize Dose, side effects, Patient

Chapters from Clinical Oncology

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

About Cancer Research UK

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

XSIGHT LUNG TRACKING SYSTEM

What is the CyberKnife System?

Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology

A Dosimetric study of different MLC expansion aperture For the radiotherapy of pancreas cancer

Regional Neuro-Oncology Service Information Evening

IMRT Planning Basics AAMD Student Webinar

Custom-Made Products / Scientific Research Instruments

Transcription:

Technology Challenges of Commercial Medical Electron Accelerators John Allen Chief Engineer Elekta Ltd

Aims of this talk Medical Radiotherapy is already a large and profitable business Well established as the standard of care, for certain cancers. New technology needs to prove itself against the successful history of improving practice. Challenges remain, but physics needs to reach across disciplines in order to displace establish clinical practice.

The scale of medical accelerator business First systems date form the early 1950s Installed base of around ten thousand clinical accelerators. Roughly third of cancer patients treated with radiotherapy. Elekta treats around a third of these Elekta is a business with a turnover exceeding 1B. Both the need and the business case, require a global scale.

Why do will still have real technical demands? Accelerators require many disciplines Medical users, whilst knowledgeable, do not want exposure to the technical complexities Understanding both the domain and working across disciplines provides a constantly changing pallet of intellectual challenge Business success is clearly linked to innovation providing incentives to the owners to increase R&D funding

Key Requirements of Medical Linacs Small (i.e. fit though door) size Capable of producing X-rays between 4MV and 20MV Isocentric mounting Means of shaping the beam MLC Accurate Dosimetry On-board Image guidance 10-15 year service life Reliable >98% uptime Safe for use on humans

From Ising and Widerøe to an major business As physicists you all know the basis of particle accelerators E A t Although the physics has not changed the technology has been transformed

Reminder - Clinical basis of radiotherapy Radiotherapy is based on differential toxicity Further enhanced by the development of fractionated radiotherapy Typical of radiotherapy for cancer care Radiosurgery is based on the ablation of tissue. Beams of radiation create a locally high dose of radiation. Used as an alternative to surgery, not necessarily for cancer treatment. E.g. AVM in brain The latest clinical techniques based on some convergence in these two strands

Translating the clinical need into product Fractionated radiotherapy This requires a patient to attend daily for a few minutes of radiotherapy This is very cost effective, as the patient can attend as an out patient However 20 to 40 set ups place demands on workflow efficiency. Managing 30 to 80 patients a day requires good organisation. Software is key to managing this efficiently and safety. Hypo fractionated or single fraction radiosurgery. Depends on the accurate targeting of tumour Modern techniques have become ever more conformal The key enable has been the multi-leaf collimator As accuracy has increased so the for imaging to guide treatment has become vital. Key success factors are dose escalation and controlling toxicity.

Why does radiotherapy require MLCs Multi-leaf collimator originated to replace metal blocks With computer technology the MLC leaves can be moved dynamically This allows much better dose distributions However the technology to do this is complex

Inside an MLC

Technology Challenges 160 servo controlled motorised leaves Each servo motor drive need to fit on less than 8cm 2 of PCB Computer controlled, yet with safety critical software Developed with the rigor required for a medical device Radiation hard electronics Designed for manufacture more than 300 systems per year Or nearly 50000 individual servo systems.

Agility geometry Leaves 90 mm high, rounded leaves, offset focus Move in conjunction with dynamic leaf guides (DLGs) to achieve 15 cm overtravel. Interdigitation Maximum speed of 6.5 cm/s (leaves (3.5) + DLG (3)). Penumbra optimised for entire leaf travel

Optics based position control Using a single CCD camera it is possible to track all 160 leaves CCD sensitivity peaks at 1µm Reliable operation is achieved by illuminating the leave with UV light Small rubies on each leaf fluoresce in the infra-red and these show clearly on the CCD image. Design allows high contrast illumination without patient glare

Imaging As treatments become more conformal the need see the target becomes more important. Key enabling technologies have been amorphous silicon flat panel imaging devices and software to perform cone beam 3D reconstruction from multiple 2D images.

Perkin-Elmer 1640AL AMSI Detector copper metal plate 1mm Gadox Photo diode Glass substrate

AMSI Detector Electronics

AMSI Panel Structure

Imaging technology = IGRT of the last decade IGRT or image guided radiotherapy By taking images just before the radiotherapy can be directly guided by the patient s anatomy The has already delivered real benefits to radiotherapy patients.

VMAT video

Agility Video

Elekta technology is just a means not an end Every year Close to 1,000,000 patients receive treatment with radiation therapy and radiosurgery equipment from Elekta Elekta Oncology Elekta Software Yet Yet radiotherapy is still massively under provisioned except in developed countries. Every day 100,000 patients receive diagnosis, treatment or follow-up that require Elekta s equipment.