Radiation Dose To Pediatric Patients in Computed Tomography in Sudan

Similar documents
CT Dose Reduction in Pediatric Patients

An Assessment of Organ and Effective Dose of Patients who Undertake CT Examinations in two Teaching Hospitals of Mashhad&Isfahan

Survey of patients CT radiation dose in Jiangsu Province

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

Accounting for Imaging Dose

Radiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology

Assessment of effective dose in paediatric CT examinations

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

Managing Patient Dose in Computed Tomography (CT)

Radiation Dosimetry for CT Protocols

Radiation exposure of the Yazd population from medical conventional X-ray examinations

CT Dose Estimation. John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology. University of California Davis Medical Center

Ask EuroSafe Imaging Tips & Tricks. CT Working Group. On the use of Diagnostic Reference Levels in CT

Introduction and Background

Utilization of a Patient Dose Tracking and Monitoring System to Modify CT Protocols and Lower Patient Doses

Managing Radiation Risk in Pediatric CT Imaging

Debra Pennington, MD Director of Imaging Dell Children s Medical Center

Regional diagnostic reference levels and collective effective doses from CT scanners in India

Measurement of Kidneys Dose in Three Hospitals during Chest and Abdomen Radiographic Examinations

National Cancer Institute

Estimation of the Risk of Cancer Associated with Pediatric Cranial Computed Tomography

The activity. Suggested Answers

Doses from Cervical Spine Computed Tomography (CT) examinations in the UK. John Holroyd and Sue Edyvean

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

A multicentric study on patient dose in multislice CT

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell

8/18/2011. Acknowledgements. Managing Pediatric CT Patient Doses INTRODUCTION

Calculation of Effective Doses for Radiotherapy Cone-Beam CT and Nuclear Medicine Hawkeye CT Laura Sawyer

Impact of quality control on radiation doses received by patients undergoing abdomen X-ray examination in ten hospitals

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

Why is CT Dose of Interest?

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Madan M. Rehani, Pedro Ortiz López International Atomic Energy Agency Vienna, Austria

Quality Control and Patient Dosimetry on line for Computed Tomography

PATIENT ENTRANCE SKIN DOSES AT MINNA AND IBADAN FOR COMMON DIAGNOSTIC RADIOLOGICAL EXAMINATIONS

CT Radiation Risks and Dose Reduction

People Exposed to More Radiation from Medical Exams

organizations including the International Commission on Radiation Protection exposure dose management system to all the studies and

Entrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals

CT Quality Control Manual FAQs

Radiation Safety in the Modern Radiology Department: A Growing Concern

EXPOSURE FROM DIAGNOSTIC NUCLEAR MEDICINE PROCEDURES. 14 Victor Babes Street, RO-6600, Iasi, Romania

PEDIATRIC CT SCAN WHERE ARE WE, DO WE REALLY KNOW THE RISKS AND WHICH WAY TO FOLLOW?

Overview of Medical Diagnostic and Interventional Imaging: Usage Patterns

Estimating Risks from CT Scans - in the Context of CT Scan Benefits

Background Radiation in U.S. ~ msv/yr msv/yr ~0.02 ~0.02 msv msv/day /day (~2 m rem/day) mrem/day) NCRP 4

Assessment of Patient Dose from CT Examinations in Khorasan, Iran

Radiation Dose Risk and Diagnostic Benefit in Imaging Investigations

Understanding radiation-induced cancer risks at radiological doses

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

3/5/2015. Don t Electrocute Me!: Common Misconceptions in Imaging and Radiation Safety (and What to Do About Them)

DETERMINATION OF ENTRANCE SKIN DOSE FROM DIAGNOSTIC X-RAY OF HUMAN CHEST AT FEDERAL MEDICAL CENTRE KEFFI, NIGERIA

Diagnostic Reference Levels (DRLs)

Radiation dose optimization in CT planning of corrective scoliosis surgery. A phantom study.

Radiation Dose in Pediatric Imaging

Quality Assurance and Optimization of Radiation Protection of Patients in X-Ray Radiographic Examinations Using the Rejects Film Analysis

Dosimetry in Medical Exposures: Trends, Challenges and Next Steps

Dianna Cody, PhD, DABR, FAAPM Professor & Clinical Operations Director Imaging Physics U.T. M.D. Anderson Cancer Center Houston, TX

Tracking Doses in the Pediatric Population

Cancer Risks from CT Scans: Now We Have Data What Next?

FDG-18 PET/CT - radiation dose and dose-reduction strategy

Skyscan 1076 in vivo scanning: X-ray dosimetry

Patient Doses in Chest CT Examinations: Comparison of Various CT Scanners

State of the art and future development for standardized estimation of organ doses in CT

Prediction of Organ and Effective dose with known mas and kvp for dose Optimisation Protocol and Recommendations in CT

Fetal Dose Calculations and Impact on Patient Care

IMAGE GENTLY HOW CAN YOU HELP?

Why radiation protection matters?

Conventional and spiral CT dose indices in Yazd general hospitals, Iran


JMSCR Vol 06 Issue 12 Page December 2018

Optimizing radiation dose by varying age at pediatric temporal bone CT

Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters

Seattle Children s Hospital Radiology Department. Statement regarding radiation exposure related to computed. tomography (CT) exams

A comparison of radiation doses from modern multi-slice Computed Tomography angiography and conventional diagnostic Angiography:

Medical Physics and Informatics Original Research

Re: PSM of the National Voluntary Consensus Standard for Patient Safety Measures, 2 nd Report

ABSTRACT. Objectives: To investigate the radiation dose received by patients undergoing routine plain x-ray

Radiation Units and Dosimetry 15 August Kalpana M. Kanal, Ph.D., DABR 1

A STUDY ON SOME PHYSICAL PARAMETERS RELATED TO IMAGE QUALITY AND RADIATION SAFETY IN DIAGNOSTIC RADIOLOGY

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre

created by high-voltage devices Examples include medical and dental x-rays, light, microwaves and nuclear energy

BrightSpeed Elite CT with ASiR: Comparing Dose & Image Quality Rule Out Pulmonary Embolism on Initial & Follow-Up Exam

Estimated cumulative radiation dose from PET/CT in children with malignancies: a 5-year retrospective review

Estimating the Radiation-Induced Cancer Risks in Pediatric Computed Tomography

Survey Effect of the Corrective Actions and Quality Control in Image Quality and Patient Dose in Radiography Examinations

Patient Radiation Doses from Adult and Pediatric CT

A Standardised Approach to Optimisation

Practice and Risk at Medical Facilities in Agency Operations

Estimated Radiation Dose Associated With Low-Dose Chest CT of Average-Size Participants in the National Lung Screening Trial

Implementation & optimization of a lung cancer screening CT program. Presented by Izabella Barreto at the 2016 Florida AAPM Chapter Meeting

Managing the imaging dose during Image-guided Radiotherapy. Martin J Murphy PhD Department of Radiation Oncology Virginia Commonwealth University

Doses from CT examinations to children suffering from hydrocephalus

Lung Cancer Screening

National collection of local diagnostic reference levels in Norway and their role in optimization of X-ray examinations

How to Develop CT Protocols for Children

Estimating Patient Radiation Dose from Computed Tomography

Patient dose assessment of CT perfusion scanning at the RSCH

Transcription:

Radiation Dose To Pediatric Patients in Computed Tomography in Sudan Omer Osman,Saeed Medical Physics Department, ALNeelain University, Sudan

Presentation outlines Introduction Objectives Materials and methods Results Discussion Conclusions

Introduction The largest contributor to the exposure of the population from artificial sources (95% 95%) only exceeded world-wide by natural background as a source of exposure. Million X-ray exams (> 300 million in children) annually worldwide..

Introduction Nowadays, computed tomography (CT) being the major source of patient exposure. It has been estimated that CT examinations make up approximately more than 10 % of the number of radiologic procedures. Radiation from CT delivers approximately 70% of the medically related radiation dose (Seeram,E. (2008)

Introduction Although, the individual risk from the radiation associated with a CT scan is quite small compared to the benefits that accurate diagnosis and treatment can provide. However, still, unnecessary radiation exposure during medical procedures should be avoided. Unnecessary radiation may be delivered when CT scanner parameters are not suitably adjusted for patient size.

Introduction In CT, there is no obvious evidence that the patient has been overexposed because the quality of the image may not be compromised. The (ICRP) (5), estimated that the risk coefficients for the average population are 5% and 1.3% sv-1, whereas for children they are 13% and 4% sv-1 for stochastic and hereditary effects, respectively

Introduction Absorbed dose in tissues from CT are among the highest observed from diagnostic radiology (i.e. 10-100 mgy). These doses can often approach or exceed levels known to increase the probability of cancer

Objectives The objectives of this study are to: (i) to measure the radiation dose and estimate the related risks to pediatric patients during CT for chest, abdomen and brain and (ii) propose a local diagnostic reference level for abdominal CT.

Materials and Methods In this study the data were collected from the following radiological departments: (i) The National Ribat University Hospital, and (ii) ) El Nilein Medical Diagnostic Centre - Khartoum. All quality control tests were performed to the machine prior any data collection. The tests were carried out by experts from Sudan Atomic Energy Commission (SAEC). All the data were with in acceptable range.

Materials and Methods: CT equipment CT scanners that participated in this study are helical CT scanners in two hospitals. The two scanners were displayed volume Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP). Table 1 CT scanners data ALnilin Manufa cture Model Siemens Somatom Emotion Duo Installation date 2006 2 slice Detector type Alribat Siemens Sensation 16 2004 16 slice

Materials and Methods: patient data A total of 80 patients were evaluated. The age of all children who were admitted in this study between 1 10 years. for each patient the following data were recorded patient demographic data, exposure factors, and scan parameters were recorded.

Estimation of Organ and effective doses The organ dose conversion factor f (organ, z) was obtained from the NRPB datasets (NRPB- SR250) based on the Monte Carlo simulations. The CTDOSE software supplied by the ImPACT group was used. CTDIair normalized to 100 mas (nctdiair), 12

RESULTS Patients age were ranged between 1 to 10 years, hight 30-130 cm, weight ranged between 2-30 Kg and Body mass index (BMI) were ranged between 9.05-43.9. Table 2 The mean values and standard division of the scan parameters Exam EL-Nilein Hospital AL-Ribat Hospital kvp mas kvp mas Brain 119.3±10 147.9±40 118.9±6.6 126.2±85 Abdomen 115.4±8.8 33.3±27 120.0±0 43.0±12. Chest - - 120.0±0 35.2±30.

Results Table Value 2 which Min shows Median variation Meanin dose 3 between rd Max quar the two centers. tile Table 3 Statistical summary of radiation doses values for brain in the tow hospitals DLP (mgy.cm) EL-Nilein 113.0 280 300±117.9 397.5 492 AL-Ribat 72.0 290 328.8±225. 9 323 995 CTDIvol (mgy) EL-Nilein 16.1 23.41 28.6±9.4 29.7 59.1 AL-Ribat 3.5 19.3 23.6±16.5 21.6 69.1 Effective dose (msv) EL-Nilein 0.5 1.5 1.7±0.9 1.8 3.6 AL-Ribat 0.3 1.8 2.5±1.7 1.1 8.2

Discussion There may be justifiable reasons for some variability in practice, of which the most important are the difficult to control the patient position and the difference in clinical indication. These reasons are greater if operators and practitioners are insufficiently educated in newly emerging technology.

Discussion The data showed that the dose in AL-Ribat is higher than EL-Nileinm. This could be attributed to the technologist in AL- Ribat radiology department for pediatric patients uses the sequential technique (slice by slice) to avoid wrong patient position. The using of the sequential technique indicate to use high mas (high mas high dose) and long scan time. And sometimes pediatric patients scanning with adult protocol (scanner design, patient age >5years or weight >20Kg is adult).

Discussion The mean radiation cancer risk was estimated to be 2.16x10-6. The radiation risks in general is lower than previous studies in the literature for abdomen and chest, while the risks for brain is higher than the previous reported studies. This can be attributed to the different technique, operator and department protocol.

Conclusions The assessment of radiation dose to pediatric patient undergoing CT brain, abdomen and chest investigated. In general, the mean values of doses are higher for CT brain and lower for abdomen and chest compare to other studies.

Conclusions Both departments use Adults CT protocol for pediatric patients. Some Scan were repeated due to referring doctor lack of knowledge ( with or without contrast, or even region of interst).

Conclusions The main contributor for this high dose was the use of different techniques and use for adult protocol, which justify the important of use child protocol. In addition the study has shown a great need referring criteria, continuous training of staff in radiation protection concepts especially for pediatric.

Thank you for your attention

References Seeram,E. (2008), Computed Tomography: Physical Principles, Clinical Applications, and Quality Control., 3rd. Edition, W.B. Saunders Co.USA. IAEA (2001): Radiology Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy, (Proceedings of an International Conference hold in Malaga, Spain, 26-30 march 2001. Amis ES, Jr., Butler PF, Applegate KE, et al(2007). American College of Radiology white paper on radiation dose in medicine. J.A. C. Radiol. 4:272-284. Arch ME, Frush DP (2008). Pediatric body MDCT: A 5-year follow-up survey of scanning parameters used by pediatric radiologists. Am. J. Roentgenol 191;611-617. International Commission on Radiological Protection. (2007). The 2007 Recommendations of the International Commission on Radiological Protection, Ann. ICRP 37(2-4), Pergamon, Oxford, UK. Rehani MM, Bongartz G, Ralender W, et al (2000). Managing x-ray dose in computer tomography : ICRP special Task force report. Ann ICPR 2000, 30:7-45.