Making an implant level cast with the angled abutment and acrylic resin cap : A clinical report

Similar documents
Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

Indian Journal of Medical Research and Pharmaceutical Sciences August 2016;3(8) ISSN: ISSN: DOI: /zenodo Impact Factor: 3.

CASE REPORT ABSTRACT INTRODUCTION. AIMS AND OBJECTIVES Aims

B U J O D. Invited Review IMPLANT IMPRESSIONS SIMPLIFIED. Reddy et al. Vol. 2 Issue-3 Sept

Solid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir

Conus Concept: A Rewarding Complete Denture Treatment

SS Implant System 2013 PROSTHETIC PROCEDURE

A comparative analysis of splinted and non-splint in opentray impression techniques on different angled implants

Fabrication of a Hybrid Screw-Retained and Cement-Retained Implant Prosthesis: A Case Report

IMPRESSION PROCEDURES TRAINING MANUAL

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

US Implant System 2013 PROSTHETIC PROCEDURE

Implant Restorations: A Step-By-Step Guide

Locator retained mandibular complete prosthesis (isy Implant System)

Element-Z Screw-Retained Hybrid

Use of the Sicat Surgical Guide In Reconstruction of the Hemi-Mandilectomy Patient

Basic information on the. Straumann Pro Arch TL. Straumann Pro Arch TL

For the oral rehabilitation

INTRODUCTION. Why Choose Cortex Prosthetics?

Tooth preparation for posterior fi xed partial denture (FPD) Tooth preparation for anterior fi xed partial denture (FPD)

KAREN O. From Failure to Fantastic

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

Orthodontic-prosthetic implant anchorage in a partially edentulous patient

Soft Tissue Transfer Utilizing Digital Impressions of Anterior Implants

Screw retained implant crown restoration with digital workflow using scan body and surgical guide

INDIAN DENTAL JOURNAL

Laser Assembled and CAD/CAM Prosthetic Frameworks for the Debilitated Mandible. Robert Schneider, DDS, MS

Prosthodontic Rehabilitation with Overdenture Using Modified Impression Technique: A Case Report

SimpleLine II Surgical / Prosthesis Manual

TS Implant System 2013 PROSTHETIC PROCEDURE

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

Steps in construction of an interim dental implant-supported hybrid prosthesis:

ABSTRACT. The Effect of Impression Technique, Connection Type and Implant Angulation on Impression Accuracy Joanna Kempler, DDS

Fixed Partial Dentures /FPDs/, Implant Supported. in implant prosthodontics

Implant Esthetic Failure

A Clinician s Guide to Restoring Conus

Case Report Prosthodontic Rehabilitation of the Patient with Severely Worn Dentition: A Case Report

Lect. 14 Prosthodontics Dr. Osama

(Images are at the end of article)

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

IMMEDIATE LOADED IMPLANTS IN EDENTULOUS PATIENTS: CLINICAL AND TECHNICAL ASPECTS USING BIOTEC TRE AND KORUM SP IMPLANTS

Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study

Guided surgery as a way to simplify surgical implant treatment in complex cases

SCD Case Study. Implant-supported overdentures

CHECK-UP Determination of Impression type & Method after implant placement

A Simplified Technique for Implant-Abutment Level Impression After Soft Tissue Adaptation Around Provisional Restoration

Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS

SURVEYING OF REMOVABLE PARITAL DENTURES FEB, 11, 2015


DIGITAL DIAGNOSIS AND TREATMENT PLANNING FOR PLACEMENT AND RESTORATION OF SINGLE IMPLANTS IN THE POSTERIOR MAXILLA By Timothy Kosinski, DDS

A retrospective study on separate single-tooth implant restorations to replace two or more consecutive. maxillary posterior teeth up to 6 years.

GuidedService. The ultimate guide for precise implantations

Benefits of CBCT in Implant Planning

The solution for the edentulous patients. Prosthetics compatibillity 3i Multi-unit Abutment Regular Abutment (MegaGen)

Continuing Education. Implant Prosthetics for the General Practice. Samuel M. Strong, DDS

In 1977, Lew1 developed a passive

CHAPTER. 1. Uncontrolled systemic disease 2. Retrognathic jaw relationship

Simplified Method for fabrication of O- Ring Implant Supported Overdenture- Case Report

The success of implant reconstruction depends

Smarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants

"Designing a fixed partial denture without a pontic"- Case report

ACRYLIC REMOVABLE PARTIAL DENTURE(RPD)

Creating emergence profiles in immediate implant dentistry

Multi-Unit Abutment Guide

Legacy Prosthetic Catalog

cement-retained single crowns using cementable abutments

Multi-unit abutment hybrid or fixed-detachable screw-retained restoration

From planning to surgery: a totally digital working flow for Leone implants placement

ident CT Guide Protocol

Complex Rehabilitation of Advanced Periodontitis Subject with a Staged Approach; Implant Supported Fixed Detachable Prosthesis

Osseointegrated implant-supported

Surveying. 3rd year / College of Dentistry/University of Baghdad ( ) Page 1

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

BUILDING A. Achieving total reconstruction in a single operation. 70 OCTOBER 2016 // dentaltown.com

PROSTHETIC PROCEDURE for TS & GS Implant System

Oral Rehabilitation with CAMLOG implants after loss of dentition due to an accident

Removable Partial Dentures

Z5mlc (Locator *) Implants

UNDERSTANDING DIGITAL DENTISTRY: CBCT AND INTRA-ORAL 30 SCANNING

Implant-based fixed rehabilitation of

Chapter 12. Prosthodontics

Multi-unit abutment bar overdenture

3Shape TRIOS Implant Scanning

The predictability of successful

Rehabilitation of Resorbed Mandibular Ridge with Implant Supported Overdenture- A Clinical Report

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Construction of Removable Partial Denture

Double-casting method for fixed prosthodontics with functionally generated path

DIAGNOSTIC/PREVENTIVE SERVICES

Anterior Restoration Splinting Implant with Natural Tooth: A Clinical Report

Then and Now. Implant Therapy:

Restoring Straumann implants. with Locator abutments.

Prosthetic V. Removable dentures I.

Jordan University of Science and Technology Faculty of Applied Medical Sciences Department of Applied Dental Sciences Second Semester Course syllabus

SCD Case Study. Attachments in Prosthodontics

Preserving the Integrity of Facial Structures with Implant-Retained Overdentures

Prosthodontic Management of Combination Syndrome Case with Metal Reinforced Maxillary Complete Denture and Mandibular Teeth supported Overdenture

verification jig fabrication

Transcription:

Medical Communication Biosci. Biotech. Res. Comm. 10(2): 319-323 (2017) Making an implant level cast with the angled abutment and acrylic resin cap : A clinical report Hamid Neshandar Asli 1 and Bardia Vadiati Saberi 2 1 Associate Professor, Dental Sciences Research Center, Department of Prosthodontics, Faculty of Dentistry, Guilan University of Medical Sciences, Rasht, Iran 2 Assistant Professor, Dental Sciences Research Center, Department of periodontology, Faculty of dentistry, Guilan University of Medical sciences, Rasht, Iran ABSTRACT Accurate casting to achieve a passive prosthesis is very important. Also, fabrication of a restoration because of the proximity implants remains a challenge. In this case report, one approach to this problem is discussed. Also, the goal of this study is analyzing fabrication an implant level cast with the help of angled abutment and acrylic resin cap. The advantage of the mentioned method is that first putting abutments provide the possibility of casting from a transferable component. Second, increase accuracy of casting by correction of path of improper implants through angled abutment. KEY WORDS: IMPLANT LEVEL CAST, ANGLED ABUTMENT, ACRYLIC RESIN INTRODUCTION Preferably, installation of implant fixtures are important in that should be parallel to each other and to adjacent teeth and be aligned vertically with axial forces. But, when fixtures are improperly positioned and soft-tissue defects are visible, conventional abutments cannot be used; therefore the use of custom angled abutments is helpful (Gualini and Berglundh, 2003). However, there is controversy about using of angled abutment. Because, some studies recommend that angled abutments result in increased stress on supporting implants, adjacent bone, and the prosthesis (Lin et al. 2008). Also, there is a challenge in fabrication of restoration on implants which have proximity together (Chaimattayompol et al. 2003, Baig et al. 2014; Papaspyridakos et al. 2015). Proximity of implant scan cause problems, however there are a number of methods to facilitate these problems (Assif et al. 1996; Selecman et al. 2009). One of the methods is using altered metal impression coping. But, sometimes this shape change is not possible because severe proximity of the implants (Chaimattayompol ARTICLE INFORMATION: *Corresponding Author: dr.bardia_vad@yahoo.com Received 1 st March, 2017 Accepted after revision 19 th June, 2017 BBRC Print ISSN: 0974-6455 Online ISSN: 2321-4007 CODEN: USA BBRCBA Thomson Reuters ISI ESC and Crossref Indexed Journal NAAS Journal Score 2017: 4.31 Cosmos IF : 4.006 A Society of Science and Nature Publication, 2017. All rights reserved. Online Contents Available at: http//www.bbrc.in/ 319

FIGURE 1. The LT. premolar region is visible in the panoramic view. et al. 2003). Another method is using of plastic impression copings to make implant level casts (Choi et al. 2006) but not all implant systems do not have this feature. Also, deformation of these plastic impression copings can affect the accuracy and strength, and reduce involvement them in impression. This case report reviews other method to make an implant level cast by an angled abutment and acrylic resin cap. MATERIAL AND METHODS Case presentation. Patient F.Z, aged 35 years with a noncontributory medical history, came to the dental office with two implant fixtures in region of LT. Mandibular premolar teeth (teeth # 20, 21). At clinical and radiographic examination, we found significant proximity between them (Fig. 1, 2). Also, Radiographic and clinical examination suggested that osseous integration and healing were within normal limits. Clinical & laboratory procedures. Design and fabrication method of the fixed prosthesis determine the impression technique, especially when implants are 2 or more (Kupeyan et al. 1995). The first, each of SICmax implants Ø 3.7 mm/9.5 mm(sic invent AG) with a stock try and use of C-Silicone Impression Material putty and Light Body Wash (speedex-coltene/whaledent) were under the impression. After the impression, gingival mask to reconstruct soft tissue height and gingival reproduction (Gingifast Elastic Zhermack Spa) was used. (Type IV dental stone (Elite Master; Zermack SpA) was used for pouring the mold. Then according to implant position, angulation, soft tissue height, and inter-occlusal space suitable abutment was selected (Giglio et al. 1999). One of them is angled abutment to correct significant proximity of the implant (Fig. 3). The screw opening hole of abutment was filled with cork and wax. Acrylic cap on the abutment also are made and then connected to cap of transfer coping with auto-polymerizing acrylic resin (DuraLay Reliance Dental MFG Company) (Fig. 4). Finally, the connected pieces were under impression with a closed-tray technique and also the use of monophase additional silicone impression material (Monopren transfer; Kettenbach). Sitting of the implant analogue which has abutment analogue controlledon the impression with rotating of them to the right &left. In addition before sitting of those components, the connected caps is set on the final impression. The final cast will be sent to a lab to firing of the porcelain. DISCUSSION The placement of multiple implant requires careful diagnosis and treatment planning. When faced with a significant proximity between them, use of an angled abutment together with a straight abutment is a suitable idea. In the past decade, impression techniques have made significant progress. During the prosthetic phase of implant treatment, there are various treatment options facing clinicians in relation to various impression techniques and available materials for making impression. The passive placement of prosthesis on implant and the correct location of implant placement are very important. The mentioned method in this study, especially for making the final cast in implants that have been inserted improperly, is suitable. In some implant systems such as ANKYLOSE, straight and angled abutments possess snap connection for impression. So, if there is proximity of implants, we can use of them. While, in the mentioned method of this study, the acrylic cap and transfer cap can be splint easily with acrylic resin and become conveniently pick up. Also, inserting the abutment and analogue set into the impression is done easily. On the other hand, the precision of this method of impression must be 320 MAKING AN IMPLANT LEVEL CAST WITH THE ANGLED ABUTMENT AND ACRYLIC RESIN CAP BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS

FIGURE 2. A) Intra-oral view of implant fixtures. B) Impression coping to show degree of proximity of implant fixtures. compared with other techniques when the implants are very close (McCartney et al. 1994; Schneider et al. 2001). The first advantage of the method in this study is the possibility of impression from a transferable component due to putting the abutments. Second, reducing differences between improper axes of the implants to less than 8 degrees by angled abutments, will increase precision of impression (Lundqvist et al. 1983; Spector et al. 1990). Based on a recent systematic review accuracy of the splint technique compared with non-splint FIGURE 3. The suitable angled & straight abutment were chosen. BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS MAKING AN IMPLANT LEVEL CAST WITH THE ANGLED ABUTMENT AND ACRYLIC RESIN CAP 321

FIGURE 4. A) Abutments with acrylic resin joined to each other. B) The final radiographic view. is far high. When the number of implants was 3 or less significant differences between the two methods, pick up and transfer, has not been observed. However, for more than 4 implants, the most studies have reported higher accuracy for pick up method (Lee et al. 2008). In addition, the polyether and vinyl poly siloxane (VPS) are recommended as the most widely used impression materials. However, there is no significant difference between these two. Also, there is no consensus about most accurate technique for casting of implants (splint or non-splint and transfer or pick up) (Baig et al. 2014; Papaspyridakos et al. 2015). Little research on other possible factors affecting the implant casting precision is available. Need to be more clinical studies to support the laboratory results. CONCLUSION In this study, a practical method for making the final implant level cast in implants that have been inserted improperly has been proposed. The advantage of the mentioned method in this study is that first putting abutments provide the possibility of casting from a transferable component. Second, increase accuracy of casting by correction of path of improper implants through angled abutment. REFERENCES Assif D., Marshak B., Schmidt A., Accuracy of implant impression techniques. International Journal of Oral & Maxillofacial Implants, 11, (1996), 216-22. 322 MAKING AN IMPLANT LEVEL CAST WITH THE ANGLED ABUTMENT AND ACRYLIC RESIN CAP BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS

Chaima ttayompol N., Arbree N.S., Wong S.X., A simple method of making an implant-level impression when presented with limited space, unfavorable implant positions, or problematic implant angulations. The Journal of prosthetic dentistry, 87, (2002), 684-7. Choi J.H., Lim Y.J., Yim S.H., Kim C.W., Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models. The International journal of oral & maxillofacial implants, 22, (2007), 761-8. Giglio G.D., Abutment selection in implant-supported fixed prosthodontics. International Journal of Periodontics & Restorative Dentistry, 19, (1999), 233-41. Gualin i F., Berglundh T., Immunohistochemical characteristics of inflammatory lesions at implants. Journal of clinical periodontology, 30, (2003), 14-8. Kupeya n H.K., Lang B.R., The role of the implant impression in abutment selection: a technical note. International Journal of Oral & Maxillofacial Implants, 10, (1995), 429-33. Lee H., So J.S., Hochstedler J., Ercoli C., The accuracy of implant impressions: a systematic review. The Journal of prosthetic dentistry, 100, (2008), 285-91. Lin C. L., Wang J.C., Ramp L.C., Liu P.R., Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading. International Journal of Oral & Maxillofacial Implants, 23, (2008), 57-64. Lundqv ist S., Carlsson G.E., Maxillary fixed prostheses on osseointegrated dental implants. The Journal of prosthetic dentistry, 50, (1983), 262-70. McCart ney J.W., Pearson R., Segmental framework matrix: master cast verification, corrected cast guide, and analog transfer template for implant-supported prostheses. The Journal of prosthetic dentistry, 71, (1994), 197-200. Schnei der A., Kurtzman G., Silverstein L., Improving implant framework passive fit and accuracy through the use of verification stents and casts. Journal of dental technology: the peerreviewed publication of the National Association of Dental Laboratories, 18, (2001), 23-5. Selecm an A.M., Wicks R.A., Making an implant-level impression using solid plastic, press-fit, closed-tray impression copings: A clinical report. The Journal of prosthetic dentistry, 101, (2009), 158-9. Specto r M.R., Donovan T.E., Nicholls J.I., An evaluation of impression techniques for osseointegrated implants. The Journal of prosthetic dentistry, 63, (1990), 444-7. M.R. B aig, Accuracy of impressions of multiple implants in the edentulous arch: A systematic review. The International journal of oral & maxillofacial implants, 29, (2014), 869-80. P. Pap aspyridakos, H. Hirayama, C.J. Chen, C.H. Ho, V. Chronopoulos, H.P. Weber, Full arch implant fixed prostheses: a comparative study on the effect of connection type and impression technique on accuracy of fit. Clinical oral implants Research, 27, (2015), 1099-105. BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS MAKING AN IMPLANT LEVEL CAST WITH THE ANGLED ABUTMENT AND ACRYLIC RESIN CAP 323