Utility of aortic cuffs in converting initially ineligible patients due to unfavorable neck anatomy into

Similar documents
Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

Technique and Tips for Complicated AAA Cases with Stent Graft

Abdominal and thoracic aneurysm repair

EVAR replaced standard repair in most cases. Why?

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

An Overview of Post-EVAR Endoleaks: Imaging Findings and Management. Ravi Shergill BSc Sean A. Kennedy MD Mark O. Baerlocher MD FRCPC

Endologix PowerWeb System EPW?

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

Nellix Endovascular System: Clinical Outcomes and Device Overview

Description. Section: Surgery Effective Date: April 15, Subsection: Surgery Original Policy Date: December 6, 2012 Subject:

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke

Case Report Early and Late Endograft Limb Proximal Migration with Resulting Type 1b Endoleak following an EVAR for Ruptured AAA

Treatment options for endoleaks: stents, embolizations and conversions

6. Endovascular aneurysm repair

My personal experience with INCRAFT in standard and challenging cases

Management of Endoleaks

Robert F. Cuff, MD FACS SHMG Vascular Surgery

3. Endoluminal Treatment of Infrarenal Abdominal Aortic Aneurysm

LOWERING THE PROFILE RAISING THE BAR

Experience of endovascular procedures on abdominal and thoracic aorta in CA region

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues

Length Measurements of the Aorta After Endovascular Abdominal Aortic Aneurysm Repair

Endovascular Aneurysm Sealing System for Treating Abdominal Aortic Aneurysms: Early Outcomes from a Single Center

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Talent Abdominal Stent Graft

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center

Morphological Study of Abdominal Aortic Aneurysm: Optimal Stent-graft Size for Japanese Patients

Hostile Proximal Neck: A New Conformable EVAR Device

Analysis of Type IIIb Endoleaks Encountered with Endologix Endografts

Abdominal Aortic Aneurysm (AAA)

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands

Anatomical challenges in EVAR

Educational Exhibit Authors:

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

symptomatic aneurysms or aneurysms that grow >1cm/yr

Endovascular surgery for abdominal aortic aneurysm

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Case Report Late Type 3b Endoleak with an Endurant Endograft

A New EVAR Device for Infrarenal AAAs

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

Management of Endoleaks. Michael Meuse, M.D Vascular and Interventional Radiology 12/14/09

Percutaneous Approaches to Aortic Disease in 2018

Multislice CT angiography in abdominal aortic aneurysm treated with endovascular stent grafts: evaluation of 2D and 3D visualisations

From 1996 to 1999, a total of 1,193 patients with

Aortic stents, types, selection, tricks in deployment.

Complications of EVAR

Considerations for a Durable Repair

Hostile Neck During EVAR, The Role Of Endoanchores

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

Mid-term results of 300+ patients treated by endovascular aortic sealing (EVAS)

TriVascular Ovation Prime Abdominal Stent Graft System

Clinical trial and real-world outcomes of an endovascular iliac aneurysm repair with the GORE Iliac Branch Endoprosthesis (IBE)

Reimbursement Guide Zenith Fenestrated AAA Endovascular Graft

Tips and techniques for optimal stent graft placement in angulated aneurysm necks

THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY

Volume 3 (2017) Issue 1 ISSN Abstract. Keywords fenestrated after open repair; Pararenal abdominal aortic aneurysm.

Access More Patients. Customize Each Seal.

CHALLENGING ILIAC ACCESSES AND THROMBOSIS PREVENTION

Clinical Efficacy of Endovascular Abdominal Aortic Aneurysm Repair

Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS

Midterm outcomes of the Zenith Renu AAA Ancillary Graft

Iliac fixation inhibits migration of both suprarenal and infrarenal aortic endografts

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs

Management of Endoleaks

12-year Experience with the Endologix Powerlink R Device in Endovascular Repair of Abdominal Aortic Aneurysms

EndoVascular Aneurysm Sealing (EVAS) with Nellix

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices?

Populations Interventions Comparators Outcomes Individuals: With abdominal aortic aneurysms eligible for open repair. are: Open repair.

CUSTOM-MADE SCALLOPED THORACIC ENDOGRAFTS IN DIFFERENT HOSTILE AORTIC ANATOMIES

How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium

AAA: DEBATE THERE ARE NO LIMITS USING EVAR FOR AAA. 2 nd -3 rd June 2016.

The Management and Treatment of Ruptured Abdominal Aortic Aneurysm (RAAA)

The diagnostic and treatment challenge of type IIIb endoleaks

Case Report 1. CTA head. (c) Tele3D Advantage, LLC

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop

OHTAC Recommendation

Challenging anatomies demand versatility.

Improving Endograft Durability with EndoAnchors

The Auckland Experience with the Nellix EVAS System. Andrew Holden, MBChB, FRANZCR

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm

Intravascular Ultrasound in the Treatment of Complex Aortic Pathologies. Naixin Kang, M.D. Vascular Surgery Fellow April 26 th, 2018

Report of Regional Single Center Experience of Endovascular Abdominal Aortic Aneurysm Repair at King Hussein Medical Center

Endoleak Sealing after AAA Endovascular Repair. When and How?

Remodeling of proximal neck angulation after endovascular aneurysm repair

Degeneration of the Neck Post Implementation - a New Era of AAA Stent

In the United States, an estimated 46 million people

No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital

Endovascular Stent Grafts for Abdominal Aortic Aneurysms

Less Invasive EVAR Transitioning to a Fast-Track Protocol

Transcription:

Utility of aortic cuffs in converting initially ineligible patients due to unfavorable neck anatomy into successful candidates for endovascular aortic aneurysm repair: A Case Series. Omer Awan 1*, Mark Garcia 2, Yousaf Awan 3, Mandip Gakhal 2, Moonjohn Kim 4, Bogdan Iliescu 4, Eliot Siegel 4 1. University of Maryland Medical Center, Baltimore, MD, USA 2. Christiana Care Health System, Newark, DE, USA 3. George Washington University School of Medicine, Washington, DC, USA 4. University of Maryland School of Medicine, Baltimore, MD, USA * Correspondence: Omer Abdulrehman Awan MD., University of Maryland Medical Center, 22 South Greene Street, Baltimore, MD 21201, USA ( hafizohms@gmail.com) :: DOI: 10.3941/jrcr.v4i3.344 ABSTRACT Endovascular repair of the abdominal aortic aneurysm has been established as a successful alternative to open surgical repair, provided that the criteria necessary for such an approach are fulfilled. Anatomic criteria include suitable diameter, length, and angle of the aneurysm proximal neck. We present three cases in which patients were initially ineligible for endovascular repair because of unfavorable neck anatomy but in whom the use of aortic cuffs allowed for successful endograft placement and aneurysm exclusion. CASE SERIES INTRODUCTION Endovascular aneurysmal repair (EVAR) of the abdominal aorta was first described as an alternative to open surgical repair in 1991 by Parodi et al. (1) and Volodos et al. (2) as a means to successfully exclude infrarenal aortic aneurysms. This technique is now widely practiced, and more than 20,000 EVAR procedures are performed every year in the United States, a number that represents approximately 40% of all abdominal aortic aneurysm (AAA) repairs (3). In EVAR, access is gained through an incision in the femoral artery and insertion of a catheter. Anigography is used to insert a graft with an alloy exoskeleton in a collapsed state. The graft is then deployed and expanded to fit the aorta. EVAR represents an alternative to open surgical repair in patients who cannot undergo standard surgical procedures because of a number of reasons, including increased age as well as co-morbid conditions such as cardiac, pulmonary, and renal disease. Other advantages of EVAR are that it is less invasive and is less expensive than conventional open repair. Also, several large trials have demonstrated that elective endovascular aortic aneurysm repair is associated with lower perioperative morbidity and mortality rates than open surgical repair (1.2% 30-day postoperative mortality for EVAR, 1

compared with 4.8% for open repair), particularly in patients with significant pre-existing co-morbidities (4,5). EVAR has also been associated with shorter hospital stays, decreased blood loss, and fewer transfusion requirements when compared with open surgical repair. Unfortunately, the ability to utilize the endovascular approach is limited by a multitude of stringent aortic and iliac anatomic criteria that must be met, depending on the type of endograft deployed. These criteria have been defined by the American College of Cardiology/American Heart Association (ACC/AHA) 2005 Practice Guidelines for the management of patients with peripheral arterial disease. Favorable anatomic characteristics include proximal neck angulation less than 60 degrees, proximal neck length greater than 15 mm, and infrarenal proximal neck diameter less than 28 mm (6). Proximal neck angulation is defined as the angle formed between the line that transects the normal aorta proximal to the aneurysm and the line that transects the long axis of the aneurysm. Proximal neck length can be defined as the length of normal aorta proximal to the aneurysm measured from the inferior portion of the renal artery to the most superior extent of the aneurysm. Proximal neck diameter is the length of normal aorta proximal to the aneurysm in the horizontal plane measured from the inferior portion of the renal artery to the most superior extent of the aneurysm (Figure 1,2). We present three patients who were initially ineligible for endovascular aortic aneurysm repair because of unfavorable neck anatomy (proximal neck angulation greater than 60 degrees, proximal neck length less than 15 mm, infrarenal proximal neck diameter greater than 28 mm) but who were successfully treated with a Powerlink endograft (Endologix; Irvine, CA) via the use of aortic cuffs. An aortic cuff is an extension device used to achieve complete seal at the proximal aortic neck in the event of suboptimal seal following initial endograft placement. Suboptimal seal may result when space is persistent between the upper end of the graft material and the aorta at the level of the proximal landing zone, with blood between the wall of the neck and the outside of the graft. This suboptimal seal is treated by insertion of an aortic cuff cranial to the endograft itself (Figure 3). The use of aortic cuffs is a valuable technique for dealing with problematic aortic aneurysm necks and expands the number of potential patients eligible for endovascular aortic aneurysm repair (7). the short aneurysm neck length and allow for placement of a Powerlink endograft. A Powerlink endograft was chosen because of operator familiarity and greater institutional experience with this device over other kinds of endografts. Under general anesthesia, bilateral femoral access was obtained by surgical femoral cutdown with subsequent placement of a 25-16-120 Powerlink endograft (25 represents the diameter of the proximal neck in mm, 16 represents the diameter of the iliac limb in mm, and 120 represents the length of the endograft in mm). Subsequently, an Endologix (Irvine, CA) 25-75 (25 represents the diameter of the aortic cuff in mm, and 75 represents the length of the cuff in mm) aortic cuff was placed, as planned to compensate for the short proximal neck length. Angiography demonstrated a type I endoleak (an endoleak is simply the persistence of blood flow around the endograft within the aneurysm sac, and a type I endoleak usually indicates an incomplete seal at either the proximal or distal attachment site); and consequently an overlapping Endologix (Irvine, CA) 25-55 aortic cuff extension was deployed to seal the endoleak (Figure 6). The completion angiogram showed no evidence of further endoleak. Follow-up angiogram (Figure 7) and CT scan (Figure 8,9) 1 year after the procedure demonstrated a patent endograft with no endoleak. Case 2: A 78-year-old man with a past medical history significant for carotid stenosis, prostate cancer, glaucoma, and macular degeneration was found on CT to have a 5-cm infrarenal abdominal aortic aneurysm after an asymptomatic pulsating abdominal mass was found on routine physical exam (Figure 10,11). The proximal aortic neck was angulated to 40 degrees, with a 29-mm proximal neck diameter, 10 mm below the renal artery level (Figure 12). The proximal aortic neck length measured 10 mm (Figure 12). A standard 28-16-140 Powerlink endograft was deployed, followed by a 36-73 Zenith aortic cuff to stabilize the short proximal aortic neck length and wide proximal aortic neck diameter. A Zenith aortic cuff was used because these generally have larger proximal cuff widths than other aortic cuffs and can better stabilize large proximal neck diameters (8). Repeat angiography following aortic cuff placement showed a persistent but mild proximal type I endoleak (Figure 13). Therefore, a P 5010 Palmaz stent (Cordis; Miami Lakes, FL) was placed at the proximal neck to better appose the endograft to the aortic wall. A completion angiogram showed no further endoleak. One-year follow-up CT also demonstrated no endoleak (Figure 14,15). CASE DESCRIPTIONS Case 1: An 81-year-old woman with medical comorbidities including coronary artery disease, hypertension, hypercholesterolemia, and chronic obstructive pulmonary disease was referred for endovascular management of an asymptomatic 5.1-cm infrarenal abdominal aortic aneurysm. The aneurysm was not seen on a computed tomography (CT) study performed three years earlier. The preoperative CT demonstrated a sharply angulated proximal neck of 70 degrees and a short proximal neck length of 10 mm (Figure 4,5), rendering the patient ineligible by standard criteria. An aortic cuff was utilized to compensate for Case 3: A 61-year-old woman with a past medical history of coronary artery disease, chronic obstructive pulmonary disease, diabetes mellitus II, hypertension, and hypercholesterolemia was referred for an infrarenal aortic aneurysm that had expanded 1.5 cm in a 1-year interval. A CT angiogram (CTA) demonstrated an infrarenal aneurysm measuring 5 cm in diameter (Figure 16) with a short, angulated (70 degrees), complex dumbbell-shaped proximal neck, measuring 31 mm in diameter and 10 mm in length (Figure 17,18). A 28-16-140 Powerlink endograft was initially placed followed by a Zenith 36-73 infrarenal aortic cuff. A Zenith aortic cuff was used for the same reason as in case two (i.e., to achieve optimal seal for a wide proximal aortic neck diameter). A completion angiogram (Figure 19) demonstrated no endoleak. 2

DISCUSSION Endovascular techniques for repair of infrarenal abdominal aortic aneurysms have rapidly evolved since the early 1990s (1,2) and are now relatively common worldwide. The various eligibility criteria, limitations of endovascular aneurysm repair, as well as the devices used, have been extensively published (8,9,10,11). However, much less has been written specifically about the use of aortic cuffs and EVAR in patients who do not meet standard criteria dictated by the 2005 ACC/AHA practice guidelines. Our experience suggests that aortic cuffs can be successfully used in conjunction with standard endografts in treating patients who are initially ineligible by standard criteria. Other institutions have also successfully treated patients with difficult infrarenal aortic aneurysm neck anatomy with aortic cuffs in conjunction with standard endografts (12,13,14,15). Specifically, Qu et al. described experience with the Endologix Powerlink endograft in EVAR with patients who had short and angulated proximal aortic necks. In that study, 54 patients had proximal aortic neck lengths measuring between 11 and 15 mm, 26 patients had proximal aortic neck lengths measuring <10 mm, and 37 patients had proximal aortic angulations >60 degrees. All 117 of these patients were treated with an Endologix Powerlink endograft as well as an aortic cuff. The technical success rate was reported as 97.4% (114/117 patients), with a 30-day mortality of 1.7 % (2/117 patients). Qu et al. concluded that the use of the Endologix Powerlink endograft device along with an aortic cuff proved safe and effective in treating patients with short and angulated proximal aortic necks for EVAR (13). Aburahma et al. reported in July 2009 on correlation of aortic neck length to early and late outcomes in EVAR patients (14). Patients were assigned to three categories: those who had aortic neck lengths greater than or equal to 15 mm (group 1), those with neck lengths between 10 and 15 mm (group 2), and those with neck lengths less than 10 mm (group 3). In that study, proximal type I endoleaks occurred in 12% of patients in group 1, 42% of patients in group 2, and 53% of patients in group 3 (P <.001). Furthermore, proximal aortic cuffs were needed to seal these type I endoleaks in 10% of patients in group 1, 38% of patients in group 2, and 47% of patients in group 3 (P <.0001). Aburahma et al. concluded that EVAR could be used for patients with short aortic necks; however, it was associated with a significantly higher rate of early type I endoleaks, resulting in an increased use of proximal aortic cuffs for sealing the endoleaks (14). Both the Aburahma et al. and Qu et al. studies, as well as our case series, demonstrate the utility of aortic cuffs in successfully treating patients who do not meet standard criteria set forth by ACC/AHA guidelines based on unfavorable proximal neck anatomy. In our case series, we also demonstrated that cuff use is not limited to a single aortic cuff, because other devices and various combinations may be necessary and can serve the equivalent purpose to a standard aortic cuff, depending on the scenario. In Case 1, two overlapping Endologix aortic cuffs were necessary because of a proximal type I endoleak after deployment of the first cuff. In Case 2, a Zenith aortic cuff was initially placed, but because of a Type I endoleak it was followed by reinforcement at the same level with a P 5010 Palmaz stent that has great radial strength in order to achieve an optimal aneurysm neck seal. In Case 3, a single Zenith aortic cuff proved to be sufficient. Our case series of three patients also highlights the fact that EVAR in patients with unfavorable proximal neck anatomy is not without risk. In two of our three cases, placement of an initial aortic cuff was complicated by the development of a type I endoleak, indicating incomplete exclusion or incomplete seal of the aneurysm. Aburahma et al. also demonstrated that the group of patients with aortic neck length of less than 10 mm had the greatest frequency of type I endoleaks, whereas the group of patients with aortic neck length greater than or equal to 15 mm had the least frequency of type I endoleaks. The risk of endoleak in initially ineligible patients by standard criteria undergoing EVAR should not be overlooked as a limitation to the procedure. Aside from type I endoleaks, three other types of endoleaks may occur during EVAR, in addition to the potential for endotension. A type II endoleak, the most common type of endoleak complicating EVAR, refers to retrograde flow from collateral vessels, particularly from the lumbar arteries or inferior mesenteric artery (16). A type III endoleak arises from a defect in the graft, which can result from a disjunction between components of the graft or even a hole in the fabric of the graft. A type IV endoleak refers to flow through the graft presumed to be associated with graft wall porosity and is usually self limited and resolves spontaneously within 1 month (16). Endotension, which is not considered a type of endoleak, is simply persistent or recurrent pressure on the endograft (16). CONCLUSION In conclusion, the use of aortic cuffs represents a useful approach for endovascular repair of abdominal aortic aneurysms with complex, large-diameter, short-length, or excessively angulated aneurysm necks. The availability of an increased variety of aortic cuffs, which in our cases included an Endologix aortic cuff, Zenith aortic cuff, and Palmaz P 5010 stent, may allow more patients to benefit from the endovascular method of aneurysm repair, particularly those who are otherwise not candidates for open surgical repair. The presence of endoleak in initially ineligible patients by standard criteria undergoing EVAR should not be overlooked as a limitation to the procedure. Much more data on long term outcomes are needed before aortic cuffs can be used as a standard procedure in patients initially ineligible for EVAR. 3

TEACHING POINT For patients who are not good candidates for open surgical repair of an AAA, EVAR represents a less invasive and less expensive alternative. In addition, for those patients who would benefit from an EVAR but do not meet the stringent practice guidelines described by the 2005 ACC/AHA, aortic cuffs can be a useful adjunct that can help seal off leaks. 8. Tan JWC, Yeo KK, Laird JR. Food and Drug Administration-approved endovascular repair devices for abdominal aortic aneurysms: a review. J Vasc Intervent Radiol 2008;19(suppl):S9-S17. 9. Hansen CJ, Aziz I, Kim BB, Donayre CE, White RA. Results from the Endologix Powerlink multicenter trial. Semin Vasc Surg 2003; 16:166-170. 10. Carpenter JP. Multicenter trial of the Powerlink bifurcated system for endovascular system for endovascular aortic aneurysm repair. J Vasc Surg 2002; 36:1129-1137. REFERENCES 1. Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991; 5:491-499. 2. Volodos NL, Karpovich IP, Troyan VI, et al. Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction. Vasa Suppl 1991; 33:93-95. 3. Schermerhorn ML, O'Malley AJ, Jhaveri A, et al. Endovascular vs. open repair of abdominal aortic aneurysms in the Medicare population. NEJM. 2008; 358: 464-474. 4. Greenhalgh, RM, Brown, LC, Kwong, GP, et al. Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: randomized control trial. Lancet 2004; 364:843. 5. Prinssen, M, Verhoeven, EL, Buth, J, et al. A randomized trial comparing conventional and endovascular repair of abdominal aortic aneurysms. N Eng J Med 2004; 351:1607. 6. Hirsch AT, Haskal ZJ, Hertzer NR, et al. ACC/AHA 2005 Practice Guidelines for the management of patients with peripheral arterial disease (lower extremity, renal, mesenteric, and abdominal aortic): a collaborative report from the American Association for Vascular Surgery/Society for Vascular Surgery, Society for Cardiovascular Angiography and Interventions, Society for Vascular Medicine and Biology, Society of Interventional Radiology, and the ACC/AHA Task Force on Practice Guidelines (Writing Committee to Develop Guidelines for the Management of Patients With Peripheral Arterial Disease): endorsed by the American Association of Cardiovascular and Pulmonary Rehabilitation; National Heart, Lung, and Blood Institute; Society for Vascular Nursing; TransAtlantic Inter-Society Consensus; and Vascular Disease Foundation. Circulation 2006; 113:e463-e654. 11. Greenberg RK, Chuter TA, Sternbergh WC III, Fearnot NE. Zenith AAA endovascular graft: intermediate-term results of the US multicenter trial. J Vasc Surg 2004; 39:1209-1218. 12. Hobo R, Laheij RJ, Buth J. The influence of aortic cuffs and iliac limb extensions on the outcome of endovascular abdominal aortic aneurysm repair. J Vasc Surg 2007; 45:79-85. 13. Qu L, Raithel D. Experience with the Endologix Powerlink endograft in endovascular repair of abdominal aortic aneurysms with short and angulated necks. Perspect Vasc Surg Endovasc Ther 2008; 20:158-166. 14. Aburahma AF, Campbell J, Stone PA, et al. The correlation of aortic neck length to early and late outcomes in endovascular aneurysm repair patients. J Vasc Surg. 2009 Jul 10. 15. Deaton DH, Mehta M, Kasirajan K, et al. The phase I multicenter trial (STAPLE-1) of the Aptus endovascular repair system: results at 6 months and 1 year. J Vasc Surg. 2009; 49: 851-857; discussion 857-8. 16. Veith FJ, Baum RA, Ohki T, et al. Nature and significance of endoleaks and endotension: Summary of options expressed at an international conference. J Vasc Surg 2002; 35:1029-1035. 7. Azizzadeh A, Sanchez LA, Rubin BG, Parodi JC, Godshall CJ, Geraghty PJ, et al. Aortic neck attachment failure and the AneuRx graft: incidence, treatment options, and early results. Ann Vasc Surg 2005; 19:516-521. 4

FIGURES Figure 1: Schematic diagram representing an infrarenal abdominal aortic aneurysm. Here, b represents the proximal neck diameter or the length of normal aorta proximal to the aneurysm in the horizontal plane measured from the inferior portion of the renal artery to the most superior extent of the aneurysm. Figure 3: Schematic diagram of an infrarenal aortic aneurysm with successful placement of an endograft (b) and an aortic cuff (a). The aortic cuff is deployed cranial or proximal to the endograft itself to achieve complete seal at the proximal aortic neck in the event of suboptimal seal following initial endograft placement. Figure 2 (left): Schematic diagram of an infrarenal abdominal aortic aneurysm. Here, a represents proximal neck length or the length of normal aorta proximal to the aneurysm measured from the inferior portion of the renal artery to the most superior extent of the aneurysm. Proximal neck angulation, depicted as α, is the angle formed between the line that transects the normal aorta proximal to the aneurysm and the line that transects the long axis of the aneurysm. 5

Figure 4: Eighty-one-year-old woman with infrarenal aortic aneurysm. Axial CT in arterial phase (CTA) with the use of 100 ml of Omnipaque 350 intravenous contrast injected at a rate of 4 ml/s shows a 5.1-cm infrarenal aortic aneurysm (arrowheads). Figure 6: Eighty-one-year-old woman with infrarenal aortic aneurysm. Intraoperative angiogram with use of 150 ml of Omnipaque 300 intravenous contrast demonstrates a type I endoleak (arrow) with contrast filling the aneurysm sac proximally. Figure 5: Eighty-one-year-old woman with infrarenal aortic aneurysm. Volume-rendered 3D image from pre-repair CT study demonstrates infrarenal abdominal aortic aneurysm with proximal neck angulation of 70 degrees and 10-mm proximal neck length (arrow). Figure 7: Eighty-one-year-old woman with infrarenal aortic aneurysm. Intraoperative angiogram with use of 150 ml of Omnipaque 300 intravenous contrast demonstrates successful endograft placement with exclusion of the abdominal aortic aneurysm (arrow). 6

Figure 8: 81-year-old woman with infrarenal aortic aneurysm. Follow-up postrepair intravenous contrast (100 ml of Omnipaque 350 injected at a rate of 4 ml/s) enhanced CT study in arterial phase (CTA) demonstrates successful aneurysm exclusion by the endograft (arrow). Figure 11: Seventy-eight-year-old man with infrarenal aortic aneurysm. Volume-rendered 3D image from pre-repair CT study demonstrates infrarenal abdominal aortic aneurysm (arrow) with a short 10-mm proximal aortic aneurysm neck with angulation of 40 degrees and diameter of 29 mm. Figure 9: Eighty-one-year-old woman with infrarenal aortic aneurysm. Endograft (arrow) as it appears on a volumerendered 3D image on a 1-y follow-up CTA examination. Arrowhead points to components of the aortic cuffs. Figure 10 (right): Seventy-eight-year-old man with infrarenal aortic aneurysm. Axial CT in arterial phase (CTA) with the use of 100 ml of Omnipaque 350 intravenous contrast injected at a rate of 4 ml/s shows a 5-cm infrarenal aortic aneurysm (arrow). 7

Figure 14: Seventy-eight-year-old man with infrarenal aortic aneurysm. Intravenous contrast-enhanced CTA with use of 100 ml of Omnipaque 350 injected at a rate of 4 ml/s obtained 1- y later reveals isolation of aortic aneurysm sac by the endograft (arrows) with no endoleak. Figure 12: Seventy-eight-year-old man with infrarenal aortic aneurysm. Intraoperative angiogram with the use of 150 ml of Omnipaque 300 intravenous contrast demonstrates a short, 10- mm proximal aortic aneurysm neck with angulation of 40 degrees and diameter of 29 mm (arrows). Figure 13: Seventy-eight-year-old man with infrarenal aortic aneurysm. Intraoperative angiogram with use of 150 ml of Omnipaque 300 intravenous contrast demonstrates a mild type I endoleak with contrast filling the aneurysm sac (between the 3 arrows). Figure 15: 78-year-old man with infrarenal aortic aneurysm. Endograft as it appears on a volume-rendered 3D image on a 1-year follow-up CTA examination (white arrow). Arrowhead shows the aortic cuff, and green arrow points to the Palmaz stent. 8

Figure 17 (bottom left): Sixty-one-year-old woman with infrarenal aortic aneurysm. Volume-rendered 3D images from preprocedure CTA demonstrates complex, short, angulated, and dumbbell-shaped proximal neck (arrow). (Proximal neck angulation of 70 degrees, proximal neck length of 10 mm, and proximal neck diameter of 31 mm). Figure 16: Sixty-one-year-old woman with infrarenal aortic aneurysm. Axial CT in arterial phase (CTA) with use of 100 ml of Omnipaque 350 intravenous contrast injected at a rate of 4 ml/s shows a 5-cm infrarenal aortic aneurysm (arrow). Figure 18 (bottom right): Sixty-one-year-old woman with infrarenal aortic aneurysm. Volume-rendered 3D images from preprocedure CTA demonstrates complex, short, angulated, and dumbbell-shaped proximal neck (arrow). (Proximal neck angulation of 70 degrees, proximal neck length of 10 mm, and proximal neck diameter of 31 mm.) 9

ABBREVIATIONS EVAR = Endovascular aneurysmal repair AAA = Abdominal aortic aneurysm ACC/AHA = American College of Cardiology/American Heart Association mm = millimeters CT = computed tomography CTA = computed tomographic angiogram ml/s= milliliters/second KEYWORDS Endovascular aortic aneurysm repair; Aneurysm proximal neck anatomy; Aortic cuff Online access This publication is online available at: www.radiologycases.com/index.php/radiologycases/article/view/344 Figure 19: Sixty-one-year-old woman with infrarenal aortic aneurysm. Intraoperative angiogram with the use of 150 ml of Omnipaque 300 intravenous contrast demonstrates successful endograft placement (arrows). Arrowhead points to the aortic cuff. Interactivity This publication is available as an interactive article with scroll, window/level, magnify and more features. Available online at Published by EduRad www.edurad.org 10