Important Information about your 2.0 ml Animas Insulin Pump Cartridges

Similar documents
URGENT MEDICAL DEVICE CORRECTION. Important Information about Animas 2020, IR 1250 or IR 1200 Insulin Pumps

Urgent Patient Notification

Urgent Medical Device Correction

HumaPen LUXURA HD INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

Important information on the Accu-Chek Insight insulin pump system: Update of the handling instructions for changing an insulin cartridge

For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges.

For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges.

HumaPen SAVVIO INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

PLEASE READ THIS USER MANUAL BEFORE USE

Urgent field safety notice

Insulin Pump Therapy

Getting Started. Learning Guide. with Insulin Pump Therapy. PUMP Foundations. for the MiniMed 530G with Enlite

How to use your gonal-f pre-filled pen

Staying safe on an insulin pump

STEP-BY-STEP GUIDE TO SELF-INFUSION. Subcutaneous Administration of GAMMAGARD LIQUID

SymlinPen (SĬM-lĭnPen) 120 (pramlintide acetate) Pen-Injector

Autopen 24 is an easy to use insulin injection pen, designed for use with 3.0ml sanofi aventis insulin cartridges. Compatible with all pen needles*.

RELEASED. first steps. Icon Icon name What it means

DO NOT TRANSFER TO A SYRINGE SEVERE OVERDOSE CAN RESULT

RELEASED. Clearing your active insulin

Getting you up to speed Quick Reference Guide

Aviva Combo BLOOD GLUCOSE METER. Advanced Owner s Booklet for Self-Testing Only

NovoPen Echo User guide

MICAFUNGIN MIXING

DIABETES MEDICAL MANAGEMENT PLAN (DMMP) School Year: Student s Name: Date of Birth:

Technology for Diabetes: 101 Basic Rules of the Road. Karen Hamon RN, BSN, CDE Stephen Stone MD, FAAP Neil H. White, MD, CDE

Urgent field safety notice

Cap Clip Rubber Seal Plunger Pen Body Dose Window

Managing your Diabetes when you are Sick. Type 1 Diabetes Insulin Pump

HUMULIN 70/30 KwikPen

PLEASE READ THESE INSTRUCTIONS BEFORE USE

Insulin Pump An information session to help you decide if you are ready to use an insulin pump.

Flash Glucose Monitoring (Flash GM) Frequently asked questions (November 2018)

Instructions for Use. HUMALOG KwikPen. insulin lispro injection (rdna origin) 100 units/ml, 3 ml pen

How to use your Pergoveris pre-filled pen

Pump Basics for the School Nurse. Children's Endocrinology Center of Dallas

10:20 AM March 5, B 100% 235 u. 124 mg/dl 3 HRS INSULIN ON BOARD:

How to Set Up and Infuse Your TPN

Accu-Chek Insight. Travelling & Holiday Guide. 3583_HolidayGuideA5booklet_Final.indd 1

INSPIRED BY GIVE HIM MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.

THE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE

Best practice for screening of insulin pumps

INSPIRED BY GIVE HER MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.

Instructions for Use. BASAGLAR KwikPen. insulin glargine injection (100 units/ml, 3 ml pen)

Predicts and helps prevent lows with. zero fingersticks NOW FEATURING BASAL-IQ TECHNOLOGY

New York State Department of Health. Notice of Voluntary Recall of Influenza A (H1N1) 2009 Monovalent Vaccine

Urgent Notice September 16, 2014

Access Points: Frequently Asked Questions 15 June 2016

Drainage Frequency: PATIENT GUIDE. Dressing Frequency: Every Drainage Weekly Drainage. Physician Contact Information. Dr. Phone:

URGENT FIELD SAFETY NOTICE MEDICAL DEVICE FIELD CORRECTION Maquet/Datascope CARDIOSAVE Intra-Aortic Balloon Pump (IABP)

DIABETIC MANAGEMENT PLAN

Medtronic MiniMed Insulin Infusion Pumps

SARASOTA MEMORIAL HOSPITAL

HOW TO USE YOUR LANTUS SOLOSTAR PEN

Caregiver Guide WITH THE OMNIPOD. MyOmniPod.com RYAN OMNIPOD WEARER

contact you the phone in

Lilly. Disposable Insulin Delivery Device User Manual

Diabetes Medical Management Plan

INTRAVENOUS IRON THERAPY

EVOGAM. Information for patients Evogam 2014 NZ Patient Brochure Update v11

OneTouch Reveal Web Application. User Manual for Patients Instructions for Use

Instructions For Use. SOLUTION FOR INJECTION IN PRE-FILLED PEN 250 micrograms

IMPORTANT: PLEASE READ

ALTERNATE CAREGIVER SESSION SPECIALLY FOR CHILDREN DIABETES EDUCATORS

INSTRUCTIONS FOR USE TYMLOS (tim lows ) (abaloparatide) injection, for subcutaneous use

UNDERSTANDING THE BASIC FEATURES AND MANAGEMENT IN THE SCHOOL SETTING CHRISTINE HERTLER RN BSN CDE & MARY MCCARTHY RN CDE

Working well with Deaf people in Social Care

CareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes

Date of Diabetes diagnosis Type I Type II. School Nurse Phone. Mother/Guardian. Address. Home phone Work Cell. Father/Guardian.

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

URGENT MEDICINE RECALL

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

DISCOVER THE POWER OF CONNECTION MINIMED 640G

GET TO KNOW YOUR PEN. Needle cap. Rubber seal. Insulin scale. Pen cap. Cartridge holder Plunger. Insulin name. Dose window Dose. pointer.

EVOGAM. Information for patients Evogam NZ Patient Brochure Update FA3

PEN USER MANUAL Byetta 5 micrograms solution for injection in pre-filled pen (exenatide)

User Guide. Insulin Pump. More freedom. More confidence. With mylife.

FAQs for HCP segment New Instructions for Dexcom G5 Mobile Continuous Glucose Monitoring (CGM) System Non-Adjunctive Indication

[Insert School Logo] School Grade Teacher Physician Phone Fax Diabetes Educator Phone 504 Plan on file Yes No

Company Overview February 26, 2019

USER GUIDE BEST LIFE Insulin Pump

INSULIN INJECTION KNOW-HOW

Education for self administration of intravenous therapy HOME IV THERAPY. 30 minute - Baxter Pump Tobramycin

MINIMED 640G SYSTEM^ Getting Started WITH CONTINUOUS GLUCOSE MONITORING

Report Reference Guide

Continuous Subcutaneous Insulin Infusion (CSII) pump therapy

Product Information Packet. Product Name: Pendulum Vertical Chest Press Product Part Number:

URGENT FIELD SAFETY NOTICE/ DEVICE RECALL

Urgent Medical Device Recall

Policy for the safe administration of Insulin

Suprapubic and Mitrofanoff Catheter Care

CIMZIA (certolizumab pegol)

First steps for success.

SCIG INFUSIONS A PRACTICAL GUIDE FOR PATIENTS

Urgent Field Safety Notice

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

Regulatory Operations. Insert size: ,5x dev Current 2.0. Colour: PMS 280C + PMS 648C + PMS 151C + PMS Green C + CMYK

Continuous Glucose Monitoring

medicines_management/correspondence/pathway-for-the-managed- Access-of-FreeStyle-Libre.

Report Reference Guide. THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1

Transcription:

URGENT: INSULIN PUMP 2.0 ml CARTRIDGE RECALL February 24, 2011 Dear Animas Pumper: Important Information about your 2.0 ml Animas Insulin Pump Cartridges Animas Corporation is dedicated to supporting pumpers with quality customer service and products. As part of that commitment, we contact our pumpers whenever we have urgent information about our products. We are sending you this letter because we have learned that some of the 2.0 ml insulin cartridges shipped between Nov. 30, 2010 and Jan. 4, 2011, can leak insulin, resulting in the delivery of less insulin than intended. In addition, if the cartridge has a leak, the pump may not alarm if there is an occlusion in the infusion set. Please note that under-delivery of insulin can cause high blood sugar and/or diabetic ketoacidosis. These are serious conditions that can cause severe health impact, including death. Symptoms of diabetic ketoacidosis may include nausea, vomiting, shortness of breath and excess thirst/urination. Contact your healthcare professional immediately if you are experiencing any of these symptoms. It is important that you check your cartridge supply and stop using these cartridges immediately. Cartridge lot numbers affected by this recall are: B201575 B201576 B201581 B201582 B201583 You can find the lot number on the side panel of the cartridge box and on the packaging of each individual cartridge as illustrated below: A full list of questions and answers are provided to you below. Animas has notified the FDA of this issue, and we have also sent a letter to healthcare providers to inform them of this issue. Again, Animas is dedicated to providing our pumpers with quality customer service and products. We know that you had a choice when choosing the pump that would work best for your lifestyle and we

appreciate that you trust us. We assure you that we are doing everything we can to address this issue quickly to avoid any further concerns. Sincerely, Animas Corporation Frequently Asked Questions What is the issue potentially affecting my pump s insulin cartridge? We have learned of several cases where a leak has occurred at the plunger side of the cartridge resulting in under-delivery of insulin during basal or bolus of insulin. What is Animas doing to address the issue? We are contacting EVERY Animas pumper that potentially received affected cartridges to notify them of the issue and what they should do to avoid any problems. We are also replacing any product that is still in the patient s possession free of charge. It is important to note that, this is a contained incident and this issue relates solely to the cartridges contained in the lots we identified. Once the cartridges are replaced, the pump will function as intended. There is not a problem with the pump. How do I know if my cartridges are affected? The following lot numbers have been identified as containing potentially affected cartridges. These lots were all shipped in the US: The lot label appears as the following: Cartridge Lot B201575 B201576 B201581 B201582 B201583 What if I am currently using a cartridge with one of these lot numbers in my pump? Change your cartridge immediately using the following instructions. See your Owners Booklet or User Guide for more detailed instructions. 1. Disconnect the infusion set from your body (failure to follow these important safety instructions can lead to unintended delivery of insulin). 2. Unscrew the cartridge cap, leaving the tubing connected to the cartridge.

3. With the tubing connected to the cartridge, pull the cartridge straight out of your pump. 4. Disconnect tubing from cartridge, set the cartridge aside to return to Animas. 5. Fill a new cartridge from an unaffected lot not listed above, and attach infusion set tubing 6. While still disconnected, rewind, load the cartridge and prime. 7. Connect tubing to site once prime is complete. 8. Fill cannula only if you have inserted a new infusion set. What are the risks of using these affected cartridges? If the affected cartridge is leaking insulin, your pump may not be delivering the proper amount of basal or bolus insulin. Under-delivery of insulin can cause high blood sugar and/or diabetic ketoacidosis. These are serious conditions that can cause severe health impact, including death. Symptoms of diabetic ketoacidosis may include nausea, vomiting, shortness of breath and excess thirst/urination. Contact your healthcare professional immediately if you are experiencing any of these symptoms. Should I adjust my basal or bolus rates to correct the under-delivery of insulin? No. If you have an affected cartridge, you must stop using the cartridge immediately and replace it with a cartridge from a lot that has not been affected. If you do not have any additional cartridges on hand, please go to your backup insulin administration plan while you await a free replacement supply, or contact your healthcare professional for additional guidance with regards to insulin dosing. Has my doctor been notified? Yes, if you are a pumper who was affected by this issue, your health care provider has also been notified. How do I get more insulin cartridges? If you are a pumper who was affected by the recall, you should have received a new supply of new 2.0 ml insulin cartridges to replace your existing supply by March 2, 2011. All replacement cartridges should have been sent to you free of charge. The replacements are clearly affixed with a green dot for ease of identification and to ensure they are not confused with the affected cartridges that must be returned. How long will it take for me to get my replacements? Replacements were shipped by the Animas Cartridge Fulfillment Center to the address we have on file for each patient. The package was scheduled to be delivered the week of February 22nd, or by the beginning of the week of February 28th, at the latest. If you have affected cartridges and do not receive a replacement supply by March 1, please contact Animas Cartridge Fulfillment Center at 1-877-280-2339. What should I do if I did not receive a letter from Animas about the faulty cartridges? We are contacting EVERY Animas pumper that potentially received affected cartridges to notify them of the issue and what they should do to avoid any problems. If you did not receive notification from Animas, then you more than likely are not impacted by this recall. We suggest to still check your lot numbers. I did not purchase my Animas cartridges directly from the company; I purchased them from a distributor. When will I be contacted about this issue? All affected distribution partners have also been contacted and instructed to identify any patients who may have received the affected cartridges. If you have any affected supply, you will be contacted directly

by the distributor regarding replacement cartridges and with further instructions to collect your affected cartridges. What do I do with the faulty cartridges? We ask that you please return all of the unused affected cartridges using the box you received with your replacement supply. The box is affixed with a pre-paid US Postal Service label. The shipment must be returned using the United States Postal Service. I received the box to return the faulty cartridges, but I lost my return label, what should I do? Contact the Animas Cartridge Fulfillment Center at 1-877-280-2339. What happens to the faulty cartridges once returned? All returned faulty cartridges will be destroyed. What if I have already used all my affected cartridges? If you do not have any product to return, please notify us that you have used all of the affected lot by logging on to the following website: www.animasnotification.com or calling the Call Center at 1-877- 280-2339 What should I do if I don t have any unaffected cartridges left and my replacement supply has not arrived? Contact us at the number above if it is past March 2, 2011 to report that you have not received your replacement supply. Until you receive your replacement and moving forward, continue to order cartridges as you normally do, as supplies are needed. If you do not have any additional cartridges on hand, please go to your backup insulin administration plan or contact your healthcare professional for additional guidance, with regards to insulin dosing. Is there anything wrong with my pump? No, there is not a problem with the pump. Any leaking of the insulin from the cartridge will not damage your pump. Could this cause any other problems with my pump if insulin leaks into the compartment? The cartridge compartment is sealed so that insulin is unable to get into the pump s critical components. If you suspect that insulin is present in your cartridge compartment, invert your pump s cartridge compartment over a paper towel and allow any liquid to drain out. Do not clean the cartridge compartment or insert anything other than a cartridge into the cartridge compartment. Do not use household cleaners, chemicals, solvents, bleach, scouring pads or sharp instruments to clean your pump. Never put your pump in the dishwasher or use very hot water to clean it. What if I have other questions? If you have technical questions or concerns, please call Animas Customer Support at 1-855-254-5668 or you can call the toll-free number on the back of your pump at 1-877-937-7867. Will the pump still recognize occlusions and alarm properly with this issue? Cartridges which are affected by this issue may not allow the pump to recognize occlusions and therefore may not alarm properly. It is important that you check your cartridge supply and stop using the cartridges immediately if they match the LOT numbers identified.

My BG s have been running higher than normal, but I haven t seen any leaks. Do you think this is the cause? Please contact our Customer Support team immediately at (877) YES-PUMP (877-937-7867) and choose Option 1 to determine if the issue is product related. Otherwise, contact your health care professional immediately. How will Animas address this in the future to avoid a similar problem? Animas has put controls in place to detect the leak condition for the cartridge. In addition, there is ongoing inspection during the cartridge molding process to make sure the condition is eliminated. Animas is dedicated to providing our pumpers with quality customer service and products. We know that you had a choice when choosing the pump that would work best for your lifestyle and we appreciate that you trust us. We assure you that we are doing everything we can to address this issue quickly to avoid any further concerns.