Quantitative detection of inhaled formoterol in human urine and relevance to doping control analysis

Similar documents
Excretion studies with beta-2-agonists

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Application Note. Author. Abstract. Introduction. Food Safety

Screening by immunoassay and confirmation & quantitation by GC-MS of buprenorphine and norbuprenorphine in urine, whole blood and serum

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Determination of Amantadine Residues in Chicken by LCMS-8040

Sample Concentration and Analysis of Human Hormones in Drinking Water

SUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM

Determination of Amphetamine and Derivatives in Urine

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

Neosolaniol. [Methods listed in the Feed Analysis Standards]

Quantitative Analysis of Amphetamine-Type Drugs by Extractive Benzoylation and LC/MS/MS. Application. Introduction. Authors. Abstract.

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system

ARTIFACT FORMATION DUE TO ETHYL THIO-

Supporting information

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

LC-MS/MS Method for the Determination of Raloxifene and its Glucuronide Metabolites from Human Plasma Using SPE Micro Elution

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Determination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

Detection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent 6410 LC/MS Triple Quadrupole

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Robust and Fast Analysis of Tobacco-Specific Nitrosamines by LC-MS/MS

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

Determination of Chlorophenoxyacetic Acid and Other Acidic Herbicides Using a QuEChERS Sample Preparation Approach and LC-MS/MS Analysis

Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System

Available online at Scholars Research Library

Extraction of 11-nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE. SLE+ Prior to GC/MS Analysis

Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Improving Benzodiazepine Immunoassay Sensitivity by Rapid Glucuronide Hydrolysis Technology

Journal of Chemical and Pharmaceutical Research

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Determination of Clarithromycin in Human Plasma by LC-EI Tandem Mass Spectrometry: Application to Bioequivalence Study

Detection of Cotinine and 3- hydroxycotine in Smokers Urine

Detection and characterization of urinary metabolites of boldione. Part I: phase I

DEXAMETHASONE. First draft prepared by Bruno LE BIZEC, Nantes, France

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Determination of Glimepiride in Human Plasma by Liquid Chromatography Electrospray Ionization Tandem Mass Spectrometry

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

Supporting Information

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Pesticide Residue Analysis in Whole Milk by QuEChERS and LC-MS/MS

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

A unique tool for metabolite research Q Exactive GC coupled with IRMS (QE GC-IRMS)

LC/MS Method for Comprehensive Analysis of Plasma Lipids

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology

LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

All stocks and calibration levels were prepared in water: methanol (50:50) v/v to cover range of all steroid concentrations (refer Table 1).

Vitamin D3 and related compounds by ESI and APCI

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a

Fast determination of residual glycerol and glycerides in biodiesel by SFC/MS using the Agilent 1260 Infinity Analytical SFC System

Authors. Abstract. Introduction. Environmental

Application Note. Abstract. Authors. Pharmaceutical

Core E Analysis of Neutral Lipids from Human Plasma June 4, 2010 Thomas J. Leiker and Robert M. Barkley

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

LC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Measuring Lipid Composition LC-MS/MS

Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID

CHAPTER 2 SIMULTANEOUS DETRMINATION OF ANASTROZOLE AND TEMOZOLOMIDE TEMOZOLOMIDE CAPSULES 20 MG AND ANASTROZOLE TABLETS 1 MG

Fig. 1: Chemical structure of arachidonic acid COOH CH 3

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

Determination of red blood cell fatty acid profiles in clinical research

Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS

Dienes Derivatization MaxSpec Kit

Determination of Pharmaceutical Residues in Bovine Milk via LC MS/MS Following Solid Phase Extraction

ETHYL GLUCURONIDE DETERMINATION IN HAIR AS AN INDICATOR OF CHRONIC ALCOHOL ABUSE: A FULLY VALIDATED METHOD BY GC-EI-MS/MS

Determination of Benzodiazepines in Urine by CE-MS/MS

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE)

Determination of memantine in human plasma by liquid chromatography electrospray tandem mass spectrometry: Application to a bioequivalence study

Ultrafast Analysis of Benzodiazepines in Urine by the Agilent RapidFire High-Throughput Triple Quadrupole Mass Spectrometry System

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

Transcription:

Quantitative detection of inhaled formoterol in human urine and relevance to doping control analysis K. Deventer* 1, O.J. Pozo 2, F.T. Delbeke 1, P. Van Eenoo 1 Short title: Detection of formoterol in urine. 1. DoCoLab, UGent, Department of clinical chemistry, microbiology and immunology Technologiepark 30, B-9052 Gent, Belgium 2. Bioanalysis research group, IMIM-Hospital del Mar Doctor Aiguader 88, 08003, Barcelona, Spain. * Author to whom all correspondence should be addressed Address for correspondence Koen Deventer DoCoLab, UGent, Department of clinical chemistry, microbiology and immunology Technologiepark 30, B-9052 Zwijnaarde, Belgium Tel: +32 (0)9/3313295 Fax: +32 (0)9/3313299 e-mail: Koen.Deventer@UGent.be http://www.docolab.ugent.be Key Words: formoterol, doping, urine, detection, LC-MS 1

Abstract Formoterol is a frequently prescribed β 2 -agonist used for the treatment of asthma. Due to performance enhancing effects of some β 2 -agonists, formoterol appears on the prohibited list, published by the World Anti-doping Agency (WADA). Its therapeutic use is allowed but restricted to inhalation. Since the data on urinary concentrations originating from therapeutic use is limited, no discrimination can be made between use and misuse when a routine sample is found to contain formoterol. Therefore the urinary excretion of 6 volunteers after inhalation of 18 µg of formoterol was investigated. An LC-MS/MS method was developed and validated for the quantification of formoterol in urine samples. Sample preparation consists of an enzymatic hydrolysis of the urine samples, followed by a liquid-liquid extraction at ph 9.5 with diethyl ether/isopropanol (5/1, v/v ). Analysis was performed using selected reaction monitoring after electrospray ionisation. The method was linear in the range of 0.5-50 ng/ml. The limit of quantification (LOQ) was 0.5 ng/ml. The bias ranged between -1.0 and -6.8 %. Results for the urinary excretion show that formoterol could be detected for 72 hours. The maximum urinary concentration detected was 8.5 ng/ml without and 11.4 ng/ml after enzymatic hydrolysis. Cumulative data showed that maximum 11.5 % and 23 % of the administered dose is excreted as parent drug within the first 12 hours, respectively non-conjugated and conjugated. Analysis of 82 routine doping samples, declared positive for formoterol during routine analysis, did not exhibit concentrations which could be attributed to misuse. 2

Introduction Formoterol is a potent long-acting β 2 -adrenergic agonist and has a pronounced and very effective bronchodilating effect [1]. Consequently, it is amongst the most prescribed drugs for humans in the treatment of asthma. Besides the desired pharmacological action,some β 2 - agonists produce side-effects on protein synthesis and lipolysis resulting in anabolic action at higher doses [2]. Hence β 2 -agonists might be misused in sports for the stimulatory effects on the respiratory and central nervous system and for growth-promoting action. To control the use of β 2 -agonists, the World Anti Doping Agency (WADA) included them in the list of prohibited substances [3] and imposed a minimum required performance level (MRPL) of 100 ng/ml [4]. Before the introduction of liquid-chromatography mass spectrometry (LC-MS), the detection of β 2 -agonists in the field of doping analysis was performed by gas chromatography-mass spectrometry (GC-MS) [5]. For formoterol N-Methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) in combination with trimethylsilyl-imidazole (TMSIm) is the preferred choice to derivatize all groups including the nitrogen of the β-ethanolamine chain [6]. Monitoring formoterol in our laboratory by GC-MS after basic liquid-liquid extraction and derivatisation never resulted in an adverse analytical finding (AAF) for this substance. Liquid chromatography-mass spectrometry (LC-MS) has proven to be an effective tool in the urinary detection of β 2 -agonists related to doping control analysis [7-10]. Its application for β 2 - agonist-detection in our laboratory since 2007, resulted in numerous urine samples which were found to contain formoterol (non published results). Because of therapeutic importance, the use of formoterol is widespread and the current (2011) situation is that the athlete should have a therapeutic use exemption (TUE). Consequently, formoterol is frequently declared on doping control forms [11]. Because the information on urinary concentrations of formoterol after inhalation is limited to one paper describing an administration study with 2 volunteers [5], it is difficult to assign the detected concentrations in the routine samples to therapeutic use or to doping misuse. Therefore, the objective of this study was to investigate the urinary excretion of a therapeutic dose of formoterol after inhalation. Additionally, concentrations from the excretion study will be compared with those observed in routine samples. 3

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Experimental Products and reagents Formoterol was obtained from Novartis ( Ringaskiddy, Ireland) and formoterol-d 6 (internal standard) (IS) from Medical-Isotopes (Pelham, USA). The preparation Oxis (formoterol fumarate) was from Astra Zeneca (Brussels). Acetic acid (HOAc) p.a., sodium acetate (NaOAc) p.a., isopropanol, diethyl ether, dipotassium carbonate (K 2 CO 3 ), sodium hydrogen carbonate (NaHCO 3 ) and sodium hydroxide (NaOH) were of analytical grade and were purchased from Merck (Darmstadt, Germany). Methanol (MeOH), ammonium acetate (NH 4 OAc) and HPLC grade water were from Biosolve (Valkenswaard, The Netherlands). Beta-glucuronidase containing 145700 units/ml glucuronidase and 714 units/ml aryl-sulphatas from Helix Pomatia was from Sigma-Aldrich (Bornem, Belgium). The buffer (ph 5.2) was obtained by dissolving 136 g NaOAc into 800 ml of aqua bidest. The ph was adjusted, if necessary, to 5.2 by adding HOAc. Then the final volume was made to 1L. Buffer (ph 9.5) was prepared by dissolving 45 g K 2 CO 3 and 37 g NaHCO 3 in 300 ml of H 2 O. 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Instrumentation The HPLC system consisted of a Surveyor MS-pump and Surveyor autosampler with a 50 µl sample loop (Thermo, San Jose, CA, USA). Twenty microliter of sample was injected. Separation was performed on a Zorbax RX C8-column (150x2mm, 5 µm) from Agilent (Diegem, Belgium). The column was maintained at 35ºC. The mobile phase consisted of water (A) and MeOH (B), both containing 1 mm NH 4 OAc and 0,1% HOAc. Gradient elution at a flow rate of 0.4 ml/min was performed as follows: 65% A for 0.5 min decreased to 20% A in 11.5 min and an increase to the initial condition of 65% A in 0.1 min followed by an equilibration step of 2.4 min before the next injection. Total analysis time per sample was 14.5 min. The LC effluent was pumped to a Quantum Discovery mass spectrometer (Thermo) equipped with an ESI source, operated in the positive ionisation mode. The capillary temperature was 350 ºC. The sheath gas flow rate was set to 50 units. No auxiliary gas was used. The mass spectrometer was operated in selected reaction monitoring (SRM) mode and transitions are presented in table 1. The precursor ions were selected in the first quadrupole with a peak width at half maximum (FWHM) of 0.7. 4

32 33 The scan speed and scan width were maintained at 100 ms and 0.01 amu, respectively. The collision gas pressure was 1.5 mtorr. 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 Sample preparation The internal standard (IS)-solution (50 µl, 100 ng/ml of formoterol-d 6 in MeOH) was added to 1 ml of urine, followed by the addition of 1 ml of acetate buffer (ph 5.2) and 50 µl of the enzyme solution. After 2.5h of incubation at 56 C, 1 ml of carbonate buffer (ph 9.5) was added. Liquid-liquid extraction was performed by rolling for 5 min with 5 ml diethyl ether/ isopropanol (5/1). After centrifugation at 1.5 G the organic layer was transferred into a new tube and evaporated until dry at 40 C under oxygen free nitrogen (OFN). The residue was dissolved in 200 µl of the initial mobile phase composition. For the analysis without hydrolysis the addition of the acetate buffer, and the enzyme solution as well as the incubation were omitted. Method validation A six-point calibration curve was generated by spiking blank urine with methanolic formoterol solutions in triplicate at 0.5, 1, 5, 10, 25 and 50 ng/ml. The ratio s of target compound product ion area to IS product ion were plotted versus concentration to obtain calibration curves. Precision and bias were tested at the lowest, middle and highest calibrator. Precision was assessed as the percentage relative standard deviation (%RSD) of both repeatability (within-day) (n=6) and reproducibility (between-day and different analysts) (n=18) for a selected level. Maximum allowed tolerances for precision can be calculated from the Horwitz-equation RSD max = 2 (1-0.5logC) (C = concentration (µg/ml) x 10-6 ). Maximum allowed tolerances for repeatability and reproducibility were 2/3 RSD max and RSD max, respectively [12]. Bias was defined as the difference between the calculated mean amount and the specified amount as a percentage [13]. The limit of quantification (LOQ) of the method was defined as the lowest concentration where precision and bias were within the above mentioned criteria. Selectivity was tested by analysing several structurally related and other routinely screened doping agents, including corticosteroids, anabolic steroids, diuretics, stimulants, narcotics and beta-blocking agents. Specificity was tested 5

63 64 65 66 67 68 69 70 71 72 73 74 75 76 by analysing 6 blank urine samples as described above to evaluate the presence of endogenous interferences. Evaluation of the ion suppression was achieved by extracting 6 blank urines following the aforementioned procedure without the addition of formoterol and IS-solution. After evaporating the organic solvent, the 6 tubes, containing the extracted matrix and an additional tube (=reference) were spiked with formoterol at 10 ng/ml and with 50 µl of the internal standard solution. After evaporating the methanolic solutions, the remaining residues were dissolved in 200 µl of the initial mobile phase and analysed. Then, the ion suppression was determined by comparing the peak areas for formoterol in the extracted urine samples with the peak area for formoterol in the reference sample. To evaluate the corrective effect of the IS on the ion suppression, area ratio s of formoterol and the IS were compared with the area ratio of formoterol and the IS in the reference sample. Excretion study 77 78 79 80 81 82 83 84 85 86 87 88 89 The study was performed with 6 healthy male volunteers aged 23, 28, 29, 31, 34 and 39. The study protocol was reviewed and approved by the ethical committee of the Ghent University Hospital (UZGent, Project B67020072141). Each volunteer signed a statement of informed consent and inhaled 18 µg formoterol (2 puffs of 9 µg ) using an Oxis Turbohaler. Urine samples were collected before (0 h) and quantitatively at 1, 2, 3, 6, 9, 12 hours after intake. Additional samples were collected after 24, 36, 48 and 72h. All urine samples were stored at -20 C awaiting analysis. Volume and ph were measured and all samples were analysed in duplicate. Collection of routine samples During a one year period doping control samples in which formoterol was detected during routine doping analysis were collected and stored at -20 C awaiting analysis. 90 91 92 93 6

94 95 Results and discussion Method development 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 As already stated in the introduction LC-MS is the preferred detection technique for β 2 agonists. The excellent LC-MS sensitivity of formoterol can be attributed to the presence of the basic nitrogen which is easily protonable during the electrospray ionisation, resulting in abundant precursor ions. MS/MS fragmentation of formoterol results in specific product ions which were explained by Thevis et al. [7]. Due to the amphoteric character of β 2 -agonists (phenolic hydroxyls and amine function) the optimal extraction ph can differ for this class of compounds [2]. Henze et al. investigated the extraction behaviour of β 2 -agonists thoroughly [14]. Formoterol showed a quasi constant extraction behaviour between ph 5 and 11. Because extraction buffers between ph 9-10 are routinely used in doping control laboratories and have proven to result in clean extracts for the determination of β 2 -agonists [5], a buffer at ph 9.5 was preferred. According to the literature, β 2 -agonists can be both excreted free, glucuronidated and sulphated [2,15]. Therefore β-glucuronidase containing also aryl-sulphatase activity was selected to hydrolyse the samples. Nevertheless, formoterol is predominantly excreted in urine conjugated as glucuronides [16-18]. According to Rosenborg et al. [17] only 4.8% of an administered dose of formoterol and deformylated formoterol are excreted in urine as 4 OH-sulphate metabolites. Method validation 114 115 116 117 118 119 120 121 122 123 124 Using a least square fit, good linearity (r 2 0.98) was observed. The calibration curve was not forced through the origin and for the regression calculation a weighing factor of 1/x was used for all data points. The results for precision and bias are summarised in Table 2 and did not exceed 2/3 RSD max or RSD max neither for repeatability nor reproducibility. Deviation of the mean measured concentration from the theoretical concentration (bias) was below the acceptable threshold of 15% and 20 % for all levels in the range of the calibration curve [13]. The limit of quantification (LOQ) of the method was 0.5 ng/ml. Regarding the selectivity, interferences from other monitored doping agents could not be found. In addition analysis of 10 different blank control urine samples did not result in the detection of 7

125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 interfering substances, proving the specificity of the method. Determining the ion suppression showed an average value of 30 % with an RSD of 19 % across the six urine samples. This high average value can be explained by the relatively large amount of matrix extracted by the diethyl ether/isopropanol mixture. The RSD of 19 % indicates a high variation of the ion suppression depending on the individual samples. This observation requires the correction by an adequate internal standard in order to obtain correct quantification. After correcting the areas of formoterol with the areas of the deuterated IS, the effect of the ion suppression was reduced to -3.4 % with an RSD of 3.5 %. Application to excretion urine samples For all volunteers formoterol could be detected already 1 hour after intake (Figure 1). The maximum urinary concentration was reached between 1 and 3 hours. The peak concentrations ranged between 1 ng/ml and 8.3 ng/ml without hydrolysis (Figure 2) and between 2.3 and 11.4 ng/ml with hydrolysis (Figure 3). The observed concentrations in this study are in agreement with the concentrations observed by Ventura et al. [5] which describe maximum urinary concentrations of 8.5 and 17.5 ng/ml for two volunteers, respectively, after inhalation of 24 µg formoterol. With hydrolysis, detection times reached up to 72 hours for some volunteers whereas without hydrolysis step the detection time was limited to 36 hours for all volunteers. The cumulative excretion profiles are presented in figures 3 and 4. The total amount of unchanged drug excreted during the first 12 hours varied between 1.1 and 2.0 µg without hydrolysis (Figure 4) and 2.5 and 4.3 µg with hydrolysis (Figure 5) corresponding to 6.3 to 11.5 % and 14 to 23 % of the administered dose, respectively. These results are in agreement with a previous paper describing that 8 % of an inhaled dose is recovered in urine as free formoterol [19] and 35% for the total fraction (both free and glucuronides)[17]. Also the difference observed in the amounts excreted free and conjugated is in accordance with previous work, which describe that formoterol is predominantly excreted conjugated more specific as glucuronides [16-18]. Large individual differences were found in the urinary concentrations as well as the excreted amounts. This variation can be assigned partially to the urinary ph and the urinary flow, which can influence the excretion of basic compounds [20]. 8

156 157 However, it can not be excluded that the variations are also caused by a poor use of the inhalation device [21]. 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 Application to routine samples During a one year period routine samples, in which formoterol was detected, were collected to determine the urinary concentrations and compare these with the ones obtained from the excretion study. A total of 7045 samples were screened and 82 samples were found to contain formoterol (1.1 %). Nearly twice as many samples containing formoterol were detected compared to a previous study where salmeterol was monitored [8]. Indeed, formoterol is the most popular β 2 -agonist used for the treatment of exercise induced asthma. The histogram showing the distribution of the detected concentrations is presented in figure 5. The highest detected concentration was 20.8 ng/ml whereas in the excretion study the maximum observed concentration was 11.4 ng/ml (Figure 6). The concentrations obtained in our study are obtained after a normal day dose of 2 inhalations. Taking into account that the dose can be increased to 6 inhalations (= total daydose of 54 µg per day) in severe cases of asthma [22], the sample in which 20.8 ng/ml was detected can be the result of such a situation. Besides, if misuse of formoterol would be widespread or higher therapeutic doses would be used much more routine samples would show concentrations higher than those obtained during the excretion study. Conclusion 180 181 182 183 184 185 186 A sensitive LC-ESI/MS/MS method for the quantification of formoterol in urine was developed and validated. The method was successfully applied to urine samples from an administration study and to urine samples collected during routine analysis. The results of the excretion study show that after inhalation of 18 µg formoterol, the parent substance could be detected up to 72 hours. The peak concentrations in urine were between 2.3 and 11.4 ng/ml. Excreted amounts show that inhaled formoterol is predominantly excreted conjugated. Taking into account the in 9

187 188 189 190 191 192 193 194 195 196 197 198 this study observed maximum concentration, the current WADA MRPL of 100 ng/ml is too high to detect inhaled formoterol after therapeutical application. Comparison of the urinary concentrations obtained during the excretion studies with the concentrations in routine doping samples did not allow to conclude that formoterol is misused by athletes for its performance enhancing effects. Acknowledgements The authors wish to thank WADA for financial support. Postdoctoral grants by the Flemish Ministry of Culture, Youth, Sports and Brussels (PVE and KD). We would also like to thank dr. Helen Van Hoecke for the assistance in the excretion studies. The technical assistance of Ruben Vandenberghe, Pascal Van Hese and Fiona Hooge is greatly appreciated. 199 200 References 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 1. D. Faulds, L.M. Hollingshead, K.L. Goa. Formoterol - a Review of Its Pharmacological Properties and Therapeutic Potential in Reversible Obstructive Airways Disease. Drugs 1991; 42, 115. 2. A. Polettini. Bioanalysis of beta 2-agonists by hyphenated chromatographic and mass spectrometric techniques. J. Chromatogr. B. 1996; 687, 27. 3. The 2011 Prohibited List, International Standard (2011). World Anti-Doping Agency (WADA). http://www.wada-ama.org/documents/world_anti-doping_program/wadp-prohibitedlist/to_be_effective/wada_prohibited_list_2011_en.pdf. Accessed 01.09.2011. 4. Technical Document: Minimum Required Performance Limits for Detection of Prohibited Substances: TD2010MRPL (2010). World Anti-Doping Agency (WADA). http://www.wadaama.org/documents/world_anti-doping_program/wadp-is- Laboratories/WADA_TD2010MRPLv1.0_Minimum%20Required%20Performance%20Levels_Sept%2001 %202010_EN.pdf. Accessed 13.01.2011. 5. R. Ventura, L. Damasceno, M. Farre, J. Cardoso, J. Segura. Analytical methodology for the detection of beta(2)-agonists in urine by gas chromatography-mass spectrometry for application in doping control. Anal. Chim. Acta. 2000; 418, 79. 6. L. Damasceno, R. Ventura, J. Ortuno, J. Segura. Derivatization procedures for the detection of beta(2)- agonists by gas chromatographic/mass spectrometric analysis. J. Mass Spectrom. 2000; 35, 1285. 7. M. Thevis, G. Opfermann, W. Schanzer. Liquid chromatography/electrospray ionization tandem mass spectrometric screening and confirmation methods for beta(2)-agonists in human or equine urine. J. Mass Spectrom. 2003; 38, 1197. 10

229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 15. D.J. Morgan. Clinical Pharmacokinetics of Beta-Agonists. Clin. Pharmacokinet. 1990; 18, 16. M. Zhang, J.P. Fawcett, J.P. Shaw. Stereoselective urinary excretion of formoterol and its glucuronide conjugate in human. Br. J. Clin. Pharmacol. 2002; 54, 246. 17. J. Rosenborg, P. Larsson, K. Tegner, G. Hallstrom. Mass balance and metabolism of [H-3]formoterol in healthy men after combined IV and oral administration-mimicking inhalation. Drug Metab. Dispos. 1999; 27, 1104. 18. H. Kamimura, H. Sasaki, S. Higuchi, Y. Shiobara. Quantitative-Determination of the Beta-Adrenoceptor Stimulant Formoterol in Urine by Gas-Chromatography Mass-Spectrometry. J. Chrom. 1982; 229, 337. 19. J.B. Lecaillon, G. Kaiser, M. Palmisano, J. Morgan, G. Della Cioppa, A. Piriano. Pharmacokinetics and tolerability of formoterol in healthy volunteers after a single high dose of foradil dry powder inhalation via Aerolizer (TM). Eur. J. Clin. Pharmacol. 1999; 55, 131. 20. G.R. Wilkinso, A.H. Beckett. Absorption Metabolism and Excretion of Ephedrines in Man.I. Influence of Urinary Ph and Urine Volume Output. J. Pharmacol. Exp. Ther. 1968; 162, 139. 21. A. Ryrfeldt, P. Andersson, S. Edsbacker, M. Tonnesson, D. Davies, R. Pauwels. Pharmacokinetics and Metabolism of Budesonide, a Selective Glucocorticoid. Eur. J. Resp. Dis. 1982; 63, 86. 8. K. Deventer, O.J. Pozo, F.T. Delbeke, P. Van Eenoo. Quantitative Detection of Inhaled Salmeterol in Human Urine and Relevance to Doping Control Analysis. Ther. Drug Monit. 2011; 33, 627. 9. R. Ventura, R. Ramirez, N. Monfort, J. Segura. Ultraperformance liquid chromatography tandem mass spectrometric method for direct quantification of salbutamol in urine samples in doping control. J. Pharm. Biomed. Anal. 2009; 50, 886. 10. M.J. Kang, Y.H. Hwang, W. Lee, D.H. Kim. Validation and application of a screening method for beta 2- agonists, anti-estrogenic substances and mesocarb in human urine using liquid chromatography/tandem mass spectrometry. Rapid Commun. Mass Spectrom. 2007; 21, 252. 11. W. Van Thuyne, F.T. Delbeke. Declared use of medication in sports. Clin. J. Sport Med. 2008; 18, 143. 12. W. Verwaal, M. van Bavel, A. Boot, J. Bravenboer, F. de Goei, C. Maas, A. van der Putten. Valideren van (fysisch-) chemische en (fysisch-) mechanische methoden op het niveau van de wettelijke eis. De ware(n)- chemicus 1996; 26, 1. 13. F. Bressolle, M. BrometPetit, M. Audran. Validation of liquid chromatographic and gas chromatographic methods - Applications to pharmacokinetics. J. Chromatogr. B. 1996; 686, 3. 14. M.K. Henze, G. Opfermann, W. Schänzer. liquid-liquid extraction ph-profiles of selected beta-2- sympathomimetic agonists. In: W. Schänzer, H. Geyer, A. Gotzmann, U. Mareck-Engelke eds, Recent Advances in Doping Analysis (7), Proceedings of the 17th Cologne Workshop on dope analysis. Cologne, Germany: Sport & Buch Strauss; 1999:335. 22. Patient Information Leaflet Oxis Turbohaler (July 2004) (2004). Astra Zeneca. http://www.astrazeneca.com.au/_mshost383378/content/legacy-sitecontent/resources/media/396789/oxis_110208_cmi. Accessed 04.10. 2011. 11

281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 Legends to figures: Figure 1: Extracted ion chromatograms for a blank sample before inhalation (b), urine sample 1h after inhalation of 18 ùg formoterol (c). transitions 345=> 121 and 149 are for formoterol, transition 351 => 155 are for formoterol-d 6. Figure 2: Concentration profiles of excreted formoterol analysed without hydrolysis Figure 3: Concentration profiles of excreted formoterol analysed with hydrolysis Figure 4: Cumulative excretion curves of formoterol (0-12h) analysed without hydrolysis Figure 5: Cumulative excretion curves of formoterol (0-12h) analysed with hydrolysis Figure 6: Histogram showing distribution of detected formoterol concentrations in 82 routine samples. 12

Table 1: MS/MS detection settings for formoterol and formoterol-d 6 [M+H] + CE DI TLV 35 93 123 54 106 123 345 34 121 123 36 134 123 19 149* 123 351 19 155 123 CE: collision energy, DI: diagnostic ion, TLV : Tube Lens Voltage, *quantifier ion Table 2: Bias, repeatability, reproducibility and tolerance limits of the LC-MS/MS method including the lowest and highest point of the calibration curves. Conc (ng/ml) Repeatability Bias (%) Reproducability Bias (%) Repeatability RSD (%) Reproducibility RSD (%) RSDmax (%) 2/3RSDmax (%) 0.5-1.0-6.8 17.1 13.3 48 32 10-0.8-2.9 1.8 2.0 32 21 50-0.05-0.3 1.6 1.0 25 16 1

345 => 121 345 => 149 351 => 155 (a) 345 => 121 345 => 149 351 => 155 (b)

9 Concentration (ng/ml) 8 7 6 5 4 3 2 Volunteer 1 Volunteer 2 Volunteer 3 Volunteer 4 Volunteer 5 1 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Time (h)

12 Concentration (ng/ml) 10 8 6 4 Volunteer 1 Volunteer 2 Volunteer 3 Volunteer 4 Volunteer 5 2 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Time (h)

Amount (ng) 4500 4000 3500 3000 2500 2000 1500 1000 500 0 Volunteer 1 Volunteer 2 Volunteer 3 Volunteer 4 Volunteer 5 0 1 2 3 6 9 12 Time (h)

Amount (ng) 4500 4000 3500 3000 2500 2000 1500 1000 500 0 Volunteer 1 Volunteer 2 Volunteer 3 Volunteer 4 Volunteer 5 0 1 2 3 6 9 12 Time (h)

40 Count C O U N T 30 20 10 0 0,00 5,00 10,00 15,00 20,00 concform C formoterol (ng/ml)