Complications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago

Similar documents
5/9/2017. Distal Radius Fractures: What s New? What s New? Or Maybe New to you. Single Pak Sterile distal radius kits

Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach

Volar fixed-angle plating for distal radius fractures 刀圭会協立病院 津村敬

Common. Common Hand Problems in Elite Athletes

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

DVR Crosslock Distal Radius Plating System. Product Brochure

Common Limb Fractures. Mr Sheraz Malik MB BS MRCS Instructor Mr Paul Ofori-Atta Mb ChB FRCS President Motc Life UK April 2009

A Patient s Guide to Adult Olecranon (Elbow) Fractures

Distal radius fractures

Operative Indications

Emile N. Brown, MD, and Scott D. Lifchez, MD

A Patient s Guide to Adult Distal Radius (Wrist) Fractures

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)

A Patient s Guide to Adult Radial Head (Elbow) Fractures

Wrist Fixation System

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Mark VanDer Kaag 1, Ajmal Ikram 2. Hand Unit, Tygerberg Hospital University of Stellenbosch

Carpal rows injuries!

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Disclosure. 85% Dorsal. 15% Volar. Distal Radius Fractures- Volar Plating for All. Skeletal Dynamics- Consultant

Radiographic Evaluation and Classification of Distal Radius Fractures

Wrist and Hand Complaints

Disclosures. Epidemiology 10/12/2015. Distal Radius Fractures: Staying Out of Trouble

6/5/2018. DISCLOSURES Hassan R. Mir, MD, MBA, FACS. Evolution of Distal Radius Fracture Treatment [Chung Hand Clinics 2012]

MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.

Index. Springer International Publishing Switzerland 2016 J.N. Lawton (ed.), Distal Radius Fractures, DOI /

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

Instrument and Implant for wrist fracture

SCAHPO-LUNATE DISSOCIATION

Client centered approach to distal radius fracture management. Jared Rasmussen OTR

COMPARATIVE STUDY OF FUNCTIONAL OUTCOME OF EXTERNAL AND INTERNAL FIXATION IN TREATMENT OF COMMINUTED DISTAL RADIUS FRACTURES

Surgical Technique Guide

A Patient s Guide to Adult Finger Fractures

Hand and wrist emergencies

IC 30: Tips and Tricks for Management of Hand Fractures-Simple to Complex

Hand Fractures: When is closed treatment OK? Epidemiology in USA: Metacarpal fractures: Page 1

Scaphoid Fractures. Mohammed Alasmari. Orthopaedic Surgery Demonstrator Majmaah University

ORIGINAL ARTICLE TREATMENT DISTAL RADIUS FRACTURE WITH VOLAR BUTTRESS TECHNIQUE- A CLINICAL STUDY

Fractures and dislocations around elbow in adult

Incidence 643,000 per year United States 15% of all fractures, peak occurrence age 60 70, Classification - AO/OTA (Murray 2013)

University of Groningen. Fracture of the distal radius Oskam, Jacob

Treatment of unstable distal radius fractures with the volar locking plate

Essential Radiographic Evaluation for Distal Radius Fractures

A Patient s Guide to Adult Forearm Fractures

Cover Page. The handle holds various files of this Leiden University dissertation.

Common Elbow Problems

epak Single-Use Delivery System

Factors Predicting Late Collapse of Distal Radius Fractures

Distal radius fractures are

journal ORIGINAL RESEARCH

Fractures of the Hand in Children Which are simple? And Which have pitfalls??

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Degrees Of Volar Angulation In Distal Radius Fracture Effects Distal Radioulnar Joint Stability:a Biomechanical Study

8 Recovering From HAND FRACTURE SURGERY

Comparative Study between Bridging External Fixation vs Volar Plating (Ellis-T Plate) for Comminuted Fracture of the Distal End Radius

Finger Mobility Deficits Fracture of metacarpal Fracture of phalanx of phalanges

D-RAD SMART PACK Plating System. A series of case studies

AcUMEDr. FoREARM ROD SYSTEM

Kousuke Iba 1*, Yasuhiro Ozasa 1, Takuro Wada 1, Tomoaki Kamiya 1, Toshihiko Yamashita 1, Mitsuhiro Aoki 2. Abstract

Rehabilitation after Total Elbow Arthroplasty

Hand Anatomy A Patient's Guide to Hand Anatomy

Radiographic Evaluation of Dorsal Screw Penetration After Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric Study

Case Presentation: Comminuted Radial Head Fracture

INTERNAL FIXATION OF THE METACARPALS AND PHALANGES P. BURGE

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016

Carpal and Finger Fractures. Donald S. Bae, MD Children s Hospital Boston

Distal radius fractures raises considerable interest and

QUICK REFERENCE GUIDE. The Pennig Dynamic Wrist Fixator. Part A: Trans-articular application

Trauma Films for Upper Body. LCDR. Naruebade Rungrattanawilai RTN M.D., LL.B. FRCOST, DMOC

Fractures of the distal radius have occupied a storied history

Sean Walsh Orthopaedic Surgeon Dorset County Hospital

BASIC PRINCIPLES OF HAND TRAUMA: ARE CHILDREN DIFFERENT? SUSAN THOMPSON, MD, FRCSC

Upper limb fractures. Mithun Nambiar Orthopaedic Resident Royal Melbourne Hospital

Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw

Physical therapy of the wrist and hand

Hand Trauma Update: Outline. Hand Surgeon s Area of Expertise. Orthopaedic Update 2015

University of Groningen. Fracture of the distal radius Oskam, Jacob

A N D R E W I R W I N, F R C S E D ( O R T H ) C O N S U L T A N T O R T H O P A E D I C S U R G E O N W E S T H E R T S N H S T R U S T, U K

Acute Wrist Injuries OUCH!

JMSCR Vol 05 Issue 06 Page June 2017

Ultrasound-guided reduction of distal radius fractures

Acu-Loc Wrist Plating System. Surgical Technique

A novel method of treating isolated unicondylar fracture of the head of the proximal phalanx: A case report

Treatment of Distal Radial Fractures

Fractures of distal end of Radius: A study on fracture reduction and stable fixation

Forearm Fracture Solutions. Product Overview

Exam of the Injured Hand and Wrist. Christina M. Ward, MD Regions Hospital TRIA Woodbury

The Elbow and Radioulnar Joints Kinesiology. Dr Cüneyt Mirzanli Istanbul Gelisim University

Outcome following distally locked volar plating for distal radius fractures with metadiaphyseal involvement

Dieter Marquardt Medizintechnik GmbH 10 Hand System

Fractures of the distal end of the radius should be

Introduction. The wrist contains eight small carpal bones, which as a group act as a flexible spacer between the forearm and hand.

Hand injuries. The metacarpal bones may fracture through the base, shaft or the neck.

JMSCR Vol 05 Issue 04 Page April 2017

Ulnar Shortening Osteotomy for Ulnar Impaction Syndrome

Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate

Acu-Loc 2 Wrist Plating System

Other Upper Extremity Trauma. Inje University Sanggye Paik Hospital Yong-Woon Shin

SCAPHOID FRACTURE. Relevant antomy

Transcription:

Complications of Distal Radius Fractures Michael S. Bednar, M.D. Loyola University Chicago How to Treat a Distal Radius Fx Need to restore motion, begin with uninvolved parts Need to reduce an unreduced fracture Need to maintain the reduction Need to place fixation appropriately KL 46 yo RHD woman left distal radius fracture on 9/17/15 from a fall Closed reduced and placed into a cast 1

9/25/15 Anatomy Palmar Ridge Dorsal Ridge Articular Facets Scaphoid Fossa Lunate Fossa Sigmoid Notch Doug Hanel MD Harborview Medical Center UW Anatomy: Radiology Radial Length Doug Hanel MD Harborview Medical Center UW 2

Anatomy: Radiology Radial Length Doug Hanel MD Harborview Medical Center UW Anatomy: Radiology Radial Length Doug Hanel MD Harborview Medical Center UW Anatomy: Radiology Radial Length Doug Hanel MD Harborview Medical Center UW 3

Anatomy: Radiology Ulnar Variance.32mm (+3 to 4) Doug Hanel MD Harborview Medical Center UW Anatomy: Radiology Ulnar (Radial) Inclination 20 Doug Hanel MD Harborview Medical Center UW Anatomy: Radiology Dorsal v Palmar Sigmoid Notch 7 Degrees Doug Hanel MD Harborview Medical Center UW 4

Anatomy: Radiology Palmar Tilt (Sagittal Tilt) 10 degrees (0 28) Unstable Fracture Lafontaine (repeated what Frykman said) Lafontaine, M.; Hardy, D.; and Delince, P.: Stability assessment of distal radius fractures. Injury, 20(4): 208-10, 1989. Dorsal angulation > 20 degrees Dorsal Comminution > 1/3 Width on Lat. X ray Intra articular Fx Ulnar fx > 60 y/o Pre reduction X ray Significant dorsal comminution is indicative of likely postreduction displacement 5

What is Unstable/Displaced? Lafontaine (repeated what frykman said) Lafontaine, M.; Hardy, D.; and Delince, P.: Stability assessment of distal radius fractures. Injury, 20(4): 208-10, 1989. Admission Reduction Union Colles Fracture Problems Goal of Treatment I. Restoration of bony anatomy Articular congruency Volar tilt Radial length 6

Goal of Treatment II. Repair Soft tissue injuries Intrinsic ligament injuries Radioulnar stability Capsular injuries and potential for scarring Neurologic injuries Joint widening Subluxation Goal of Treatment III. Restoration of motion First Begin before surgery Digital Shoulder Second Wrist Forearm 9/25/15 Reduced? 7

KL Closed reduction not successful Brought to OR for operative intervention External Fixation and Percutaneous Pinning Percutaneous Pinning 8

Percutaneous Pinning 10/5/15 10/19/15 9

KL Pins in for 8 weeks Cast maintained 2 weeks due to concerns for fracture healing When cast removed, begins OT 11/16/2015 KL 12/15/17 First visit with me Problems Pain Swelling Difficulty with ROM of fingers, wrist, and forearm 10

KL 12/15/17 PE ROM Sup/Pron 0/60 Wrist Ext/Flex 0/20 Finger MP 0/40 PIP 40/80 Negative Tinel s sign over wrist (CPRS Type 2) 5 mm 2 point 12/15/16 30 KL 12/15/17 Problems Stiffness of fingers Malunion of distal radius Plan OT to restore ROM of digits 11

KL 1/14/16 TAM of each digit improved 40 60 degrees Pain and swelling have decreased OR for osteotomy ISSUES: Palmar or dorsal approach? Autograft or allograft? 12/15/16 1/25/16 12

3/4/2016 KL 3/4/16 Problems after surgery Wrist ROM 0/60, pain with motion past 15 degrees of extension Sup/Pron 20/70 Tightness of the digits Cast wrist in maximum extension OT for ROM of digits 13

Finger MP motion Index 0 90 Middle 0/90 Ring 0/70 Small 0/70 Wrist 0/40 Remove plate KL 7/14/16 9/12/16 How to Treat a Distal Radius Fx Need to restore motion, begin with uninvolved parts Need to reduce an unreduced fracture Palmarly displaced fracture is a Fracture of Necessity Need to maintain the reduction Need to place fixation appropriately 14

8/11/16 Problems Aching sensation of wrist Loss of supination 1/26/17 15

16

Distally angled pegs neutralize dorsal forces Joint Reaction Force Volar buttress neutralizes volar forces Complications Incomplete Reduction of Fracture Persistently dorsally displaced or angulated Leads to prominence of distal plate at watershed line Complications Incomplete Reduction of Fracture Persistently dorsally displaced or angulated Leads to prominence of distal plate at watershed line 17

Complications by the Steps of the Procedure Intra operative Plate too distal Flexor tendon irritation/rupture Correct Placement of Hardware Plate Too Proximal This material is intended for the sole use and benefit of surgeons attending the Elite Surgeon Education event. It is not to be distributed, duplicated or disclosed without the written consent of Biomet. 9/6/2013 Rev. 2 Correct Placement of Hardware 32 yo female massage therapist S/p ORIF of distal radius 3 months ago Restricted, painful supination Placed in dyamic forearm brace 18

Intra Articular Screw Placement Complications Screws Too Long Irritation of extensor tendons EPL most commonly ruptured Causes, Benson (CORR 2006) Postreduction bone spurs Dorsal gapping Prominent screw tips 19

Complications Screws Too Long Difficult to determine screw length intraoperatively, Greenberg (J Hand Surg Am 2009) Fluoroscopy sensitivity in detecting cortical penetration 82% sensitive in the radial most position 77% sensitive in the central position 57% sensitive in the ulnar position Complications Screws Too Long Treatment High index of suspicion Undersize locking/screw peg Remove hardware if irritation occurs Complications Screws Too Short Poor support with subchondral bone Locking screws/pegs need to be in contact with dorsal subchondral bone Locking screws/pegs need to be at least 75% of the AP diameter of the subchondral surface 20

LB How to Treat a Distal Radius Fx Need to restore motion, begin with uninvolved parts Need to reduce an unreduced fracture Need to maintain the reduction Need to place fixation appropriately THANK YOU 21