3D printing lunate prosthesis for stage IIIc Kienböck s disease: a case report

Similar documents
The Kienböck disease and scaphoid fractures. Mariusz Bonczar

Carpal rows injuries!

Wrist Arthritis & Partial Wrist Fusion

Vascular Pedicle Pisiform Bone Grafting for Kienbocks Disease : A Case Report

SCAHPO-LUNATE DISSOCIATION

Mayo Clinic Disorders of the Wrist

Arthroplasty for advanced Kienböck s disease using a radial bone flap with a vascularised wrapping of pronator quadratus

Proximal row carpectomy : a motion-preserving procedure in the treatment of advanced Kienbock s disease


TRIQUETRUM FRACTURE. The triquetrum bone is one of the small bones that make up the carpus.

Arhtroscopy of the wrist joint: Setup, instrumentation, anatomy & indications

Scaphoid Fractures. Mohammed Alasmari. Orthopaedic Surgery Demonstrator Majmaah University

Union rate: Union: Stable 94% All fracture 90% Union after surgery for nonunion with surgery 80% OA in healed scaphoid: 9%

Poll the Audience 5/29/2015. Wrist Arthroplasty Where are we now?

Interesting Case Series. Ulnolunate Impaction Syndrome

Introduction. The wrist contains eight small carpal bones, which as a group act as a flexible spacer between the forearm and hand.

COMMON CARPAL INJURIES IN ATHLETES Nicholas A. Bontempo, MD Orthopedic Associates of Hartford I HAVE NO CONFLICTS OR DISCLOSURES TO REPORT OUTLINE

Characterizing scaphoid nonunion deformity using 2-D and 3-D imaging techniques ten Berg, P.W.L.

Watson Classification. Proximal Row Carpectomy SLAC Wrist. Disclosure 11/13/2017. No Shiney Metal Objects Utilized NONE

Surgical Technique. DISCLOSURE: This device is not approved for sale in the U.S.A. Customer Service:

Ascension. Silicone MCP surgical technique. surgical technique Ascension Silicone MCP

Kienboeckdisease. Treatment options. F. Hahn

NE Nebraska Trauma Conference Tristan Hartzell, MD November 8, 2017

ANATOMIC TOTAL SHOULDER REPLACEMENT:

Isolated dislocation of the carpal scaphoid without the

2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

3. Ulno lunate, Ulno triquetral ligament. Poirier: Between RSC &LRL. 5. Dorsal intercarpal ligament

Integra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE

Hand Surgery Department Poznan University of Medical Sciences. Piotr Czarnecki

8 Recovering From HAND FRACTURE SURGERY

SPORTS INJURIES IN HAND

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)

Interesting Case Series. Perilunate Dislocation

This presentation is the intellectual property of the author. Contact them for permission to reprint and/or distribute.

MR IMAGING OF THE WRIST

Sean Walsh Orthopaedic Surgeon Dorset County Hospital

CLINICAL PRESENTATION AND RADIOLOGY QUIZ QUESTION

Proximal row carpectomy : A volar approach

Hand and wrist emergencies

Integra. PyroCarbon Lunate SUTURE ANCHOR SURGICAL TECHNIQUE

Chpter 2 Nonoperative Management of Non-displaced Acute Scaphoid Fracture

University of Groningen. Fracture of the distal radius Oskam, Jacob

Rehabilitation after Total Elbow Arthroplasty

Neglected trans-scaphoid trans-styloid volar dislocation of the lunate

SYMPOSIUM ON ADVANCES IN THE MANAGEMENT OF SCAPHOID PROBLEMS Scaphoid malunion

A Lane In Headingley Leeds John Atkinson Grimshaw, oil on board 1881

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

journal ORIGINAL RESEARCH

CARPAL ANATOMY. 2 carpal rows:

WristMotion Wrist Hemiarthroplasty System Instructions for Use

Bipolar Radial Head System

Wrist & Hand Assessment and General View

Mayo Clinic Disorders of the Wrist

Treatment Approach To Cases Of Nonunion Intercondylar Fracture Humerus

Nearly all of these fractures are displaced, given the paucity of soft tissue attachments.

D Degenerative joint disease, rotator cuff deficiency with, 149 Deltopectoral approach component removal with, 128

Ankle Replacement Surgery

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

A Patient s Guide to Adult Distal Radius (Wrist) Fractures

Limited intercarpal fusion as a salvage procedure for advanced Kienbock disease

Wrist movements, apart from the distal radioulnar joint, take place in two planes:

Wrist Joint Reconstruction With a Vascularized Fibula Free Flap Following Giant Cell Tumor Excision in the Distal Radius

Reliability of Lichtman s classification for Kienböck s disease in 99 subjects

Recurrent subluxation or dislocation after surgical

Elbow Fractures ORIF VS Arthroplasty

A Patient s Guide to Elbow Dislocation

TABLE OF CONTENTS. Limited intercarpal joint arthrodesis (including isolated capitolunate, two-column and four-corner fusions)

Interesting Case Series. Simultaneous Avascular Necrosis of the Lunate and Scaphoid

The Forearm, Wrist, Hand and Fingers. Contusion Injuries to the Forearm. Forearm Fractures 12/11/2017. Oak Ridge High School Conroe, Texas

MANAGEMENT OF INTRAARTICULAR FRACTURES OF ELBOW JOINT. By Dr B. Anudeep M. S. orthopaedics Final yr pg

Integra. Thumb Joint Replacement PATIENT INFORMATION. with PyroCarbon implants

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation

Index. B Backslap technique depth assessment, 82, 83 diaphysis distal trocar, 82 83

Ascension. MCP surgical technique. surgical technique Ascension MCP PyroCarbon Total Joint

Distraction Arthroplasty of the Trapeziometacarpal Joint Without Trapeziectomy

Arthroscopy: today the gold-standard in wrist joint surgery. Ivan Tami. Swiss Medical Network. Musculoskeletal Conference, Bern.

Integra. Titan Modular Shoulder System, 2.5

Posterolateral elbow dislocation with entrapment of the medial epicondyle in children: a case report Juan Rodríguez Martín* and Juan Pretell Mazzini

Link to related CJSM article: ts Frequency_and.5.

SPEED TM Hand & Wrist System. Procedure Manual

Acute Wrist Injuries OUCH!

7/23/2018 DESCRIBING THE FRACTURE. Pattern Open vs closed Location BASIC PRINCIPLES OF FRACTURE MANAGEMENT. Anjan R. Shah MD July 21, 2018.

Comparison between Distractor Application on Both Radial & Ulnar Side and Radial Side Only for Fracture Distal Radius with Ulnar Styloid Fracture

New classification of lunate fossa fractures of the distal radius

Common. Common Hand Problems in Elite Athletes

Chapter 13. Arthroscopic Lunotriquetral Arthrodesis and Head of the Hamate Resection. Introduction. Operative Technique (Fontes) Midcarpal Exploration

Lunate and Perilunate Dislocations: Our Experience

Int J Clin Exp Med 2018;11(2): /ISSN: /IJCEM Yi Yang, Hao Liu, Yueming Song, Tao Li

Cover Page. The handle holds various files of this Leiden University dissertation.

Scaphoid Non-Union Current Treatment Options

A Dynalllic Splint for U se After Total Wrist Arthroplasty

Nursing Management: Musculoskeletal Trauma and Orthopedic Surgery. By: Aun Lauriz E. Macuja SAC_SN4

Staged reduction of neglected transscaphoid perilunate fracture dislocation: A report of 16 cases

Total Ankle Arthroplasty. Joseph P. McCormick, M.D. Affinity Orthopedics & Sports Medicine the original 2014

Osteosynthesis involving a joint Thomas P Rüedi

Management of Acute Trans Scaphoid Peri-Lunate Fracture Dislocation by Closed Reduction and Percutaneous Fixation

Concurrent scaphoid fracture with scapholunate ligament rupture

)451( COPYRIGHT 2017 BY THE ARCHIVES OF BONE AND JOINT SURGERY. Evaluation of Normal Ranges of Wrist Radiologic Indexes in Mashhad Population

Fractures and dislocations around elbow in adult

A Patient s Guide to Elbow Dislocation

Transcription:

https://doi.org/10.1007/s00402-017-2854-0 ORTHOPAEDIC SURGERY 3D printing lunate prosthesis for stage IIIc Kienböck s disease: a case report Mei ming Xie 1 Kang lai Tang 1 Chen song Yuan 1 Received: 9 July 2017 / Published online: 12 December 2017 The Author(s) 2017. This article is an open access publication Abstract Stage IIIc Kienböck s disease is a clinical challenge to treat collapse of the lunate bone. A new reconstructive surgery was described in one patient using 3D printing lunate prosthesis. The prosthesis shape was designed by tomographic image processing and segmentation using technology compared with the intact side matched by mirror symmetry and 3D postprocessing technologies. The patient recovered nearly full range of motion of the wrist after 12 months. The visual analog scale scores and Cooney scores were 2 points and 91 points. We demonstrated that an anatomical reconstruction to Kienböck s Disease is possible using 3D printing lunate prosthesis. Keywords 3D printing technology Kienböck s disease Wrist Avascular necrosis Introduction The Kienböck s disease is caused by avascular necrosis of the lunate bone [1]. According to the modified Lichtman radiologic classification, the disease is divided into four stages. Stage IIIc Kienböck s disease is a clinical challenge to treat collapse of the lunate bone. It is a complete coronal plane split regardless of the lunate and wrist morphology [2, 3]. Various methods have been reported to stage IIIc, including transplant of pedicled pisiform bone, radial resection, radioscapholunate arthrodesis, scapho-trapezio-trapezoid arthrodesis and lunate bone replacement, etc [4 8]. Spies et al. and Unglaub et al. [9, 10] adopted proximal carpal row carpectomy and partial fusion of the wrist to obtain excellent clinical results. Bone transplantation cannot originally repair lunate shape and location. Arthrodesis can decrease the load and increase bone fusion, however, prevent the movement of the lunate between the distal rows of the carpal bone. So * Kang lai Tang tangkanglai@hotmail.com Mei ming Xie 93319521@qq.com Chen song Yuan 530270472@qq.com 1 Third Military Medical University Southwest Hospital, Chongqing, China the restoration of anatomical structure and activity of lunate is a clinical problem. With the development of three-dimensional (3D) printing, the technology was used to design and create complex replacement for bone structures [11 13]. If the cartilage of the radius and capitate were intact, by the way, in IIIc after Lichtman, it is untypical, so the prosthesis replacement surgery is an alternative option. The experimental case is the first report of 3D printing prosthesis which applied to stage IIIc Kienböck s disease. The purpose was to present the new treatment method and clinical outcome. Case presentation A 41-year-old visited to our hospital because of wrist pain for more than 2 years after an accidental fall. The patient felt wrist swelling, chronic pain, fatigue, limited activity in immoderate activity, unable to adhere to heavy manual jobs. The region of the lunate has a tenderness when palpated. Wrist was limited in each direction, especially in wrist dorsal extension. Plain radiographs and MRI showed that the lunate density was uneven and the height and width of lunate were collapsed when compared with the intact wrist (Fig. 4a d). This study was approved by the Ethics Committee of the Southwest Hospital Affiliated with the Third Military Medical University. Informed consent was obtained from the patient. Preoperative MRI and X-rays showed that Vol.:(0123456789)

448 Archives of Orthopaedic and Trauma Surgery (2018) 138:447 451 the lunate density was uneven and the height and width of lunate were collapsed. The 3D printing technology applied to design and product lunate prosthesis. The complete data of the affected lunate were acquired by tomographic image processing and segmentation using 3D CT post-processing technology, and the intact 3D data of the affected side were obtained by reconstruction and matching based on mirror technology and data registration technology. The serious data defects of the necrotic lunate were repaired using reverse repairing technology to provide the non-defect data for lunate reconstruction (Fig. 1). The new surgical technique was performed in a supine position under combined spinal epidural analgesia. First, the necrotic lunate was exposed with the dorsal skin incision and the lunate bone was resected. The cartilages of capitate and radius were smooth without the signs of osteoarthritis. The necrotic or inflammatory tissues were removed (Fig. 2a, b). The polyethylene prosthesis tested good matching performance of the 3D printing model. The 3D printing prosthesis was placed in the original anatomic position of the lunate (Fig. 2c, d). The prosthesis was check to be not dislocated during dorsal extension, palmar flexion, radial deviation and ulnar deviation of the wrist (Fig. 3). The dorsal articular capsule was sutured. The wrist was fixed with a plaster in the functional position for 4 weeks, and functional exercises of dorsiflexion and flexion to improve the range of wrist motion. The patient was able to use her wrist with mild pain during sport activities after 12 months. Weakness and numbness of the wrist were not observed. Nearly full range of motion and grasp force of the wrist was obtained (Table 1). Degenerative arthritis and prosthetic dislocation on plain radiographs were not showed. The 3D printing lunate prosthesis Fig. 1 The necrotic lunate were reconstructed using reverse repairing technology to provide the non-defect data Fig. 2 The necrotic lunate was resected (a, b); the 3D printing prosthesis was placed in the original anatomic position of the lunate (c, d)

449 Fig. 3 The prosthesis was check to be not dislocated during dorsal extension, palmar flexion, radial deviation and ulnar deviation of the wrist (a d) Table 1 Comparison of wrist ROM and grasp force was placed in the original anatomic position (Fig. 4e, f).the visual analog scale scores and Cooney scores were 2 points and 91 points. Discussion The affected wrist Before surgery At the last visit Dorsal extension 30.7 54.2 56.3 Palmar flexion 28.5 50.5 51.8 Ulnar deviation 10.2 23.8 25.0 Radial deviation 8.6 16.4 18.0 Grasp force (kg) 20.4 36.2 39.6 The intact wrist Stage IIIc Kienböck s disease is a clinical challenge to anatomical reconstruction [14].The common treatment measure is carpal bone arthrodesis because of decreasing the load on the lunate bone, however, it might reduce wrist mobility [15]. If the cartilage of the radius and capitate were intact in stage IIIc and the surgeon maximum reserve articular cartilage and joint activity, the matched prosthesis was designed to apply in the reconstruction.so we attempt to reconstruct the original model of lunate prosthetic through 3D printing technology. Actually, most of medical applications of 3D printing technology has been prosthesis [16]. 3D printing technology offers a new option to fabricate complex shape and structure of lunate [17, 18]. The accurate lunate imaging data were segmented and 3D reconstruct on the basis of CT and MRI. The intact lunate model was matched by a comparison of the healthy and affected sides using mirror symmetry and multidimensional computer reconstruction technology. It simulated the virtual surgical procedure to certify the operability of lunate prosthesis implantation. The 3D printing technology has allowed orthopedists to design and manufacture anatomically matched implants used in surgeries [19]. In the surgery, the 3D printing lunate returned to its original shape and location. It achieves a tight 3D match between the three carpal bones, respectively. Fixation stability was certified by rotating the wrist. The lunate implant position was checked using C-arm fluoroscopy. The prosthetic interface was smooth. It showed that the prosthesis provided a support to carpus after excision of the lunate bone and avoided adjacent osteoarthritis. There are some reports for lunate replacement, including vitallium, acrylic materials or pyrocarbon lunate arthroplasty [20 22]. However, lunate replacement have not been popular

450 Archives of Orthopaedic and Trauma Surgery (2018) 138:447 451 Fig. 4 Preoperative MRI and X-rays showed that the lunate density was uneven and the height and width of lunate were collapsed (a c); the intact wrist X-ray (d); the 3D printing lunate prosthesis was placed in the original anatomic position (e, f) because of the congruity and inherent instability [2]. The SL and LT ligaments were cut off and did not repaired after the prosthesis implantation. The stability of lunate prosthesis was primarily maintained by the surrounding bony structures. To prevent the dislocation and prolapse, the articular capsule was closely repaired and sutured. The plaster was fixed in the wrist to strength the repair of the articular capsule and the soft tissues and the wrist moved after 4 weeks to prevent the prosthesis dislocation. Compared with previous reports about lunate implantation, the 3D printing prosthesis shows the preservation of adjacent congruity. We believe 3D printing lunate prosthesis provides a reliable option to stage IIIc Kienböck s disease by preserving lunate anatomy and the mobility of the wrist. The individualized 3D-printing lunate prosthesis might be designed according to the variation of lunate functional anatomy and the Wolf Law by composite computer information technologies in the future. The interesting result is that an anatomical reconstruction to Kienböck s disease is possible using 3D printing lunate prosthesis. Compliance with ethical standards Conflict of interest All authors declared that they have no conflict of interest. Funding The 3D printing prosthesis was provided by the funding a funding source from the National Key Research and Development of China (2016YFC1100500). Ethical approval This article does not contain any studies with human participants or animals performed by any of the authors. Informed consent Informed consent was obtained from all individual participants included in the study. Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. References 1. Wagner JP, Chung KC (2005) A historical report on Robert Kienbock (1871 1953) and Kienbock s disease. J Hand Surg Am 30:1117 1121 2. Bain GI, Yeo CJ, Morse LP (2015) Kienbock disease: recent advances in the basic science, assessment and treatment. Hand Surg 20:352 365

3. Lichtman DM, Lesley NE, Simmons SP (2010) The classification and treatment of Kienbock s disease: the state of the art and a look at the future. J Hand Surg Eur Vol 35:549 554 4. Bain GI, Ondimu P, Hallam P et al (2009) Radioscapholunate arthrodesis a prospective study. Hand Surg 14:73 82 5. Tatebe M, Koh S, Hirata H (2016) Long-term outcomes of radial osteotomy for the treatment of Kienbock disease. J Wrist Surg 5:92 97 6. Salt O, Sayhan MB (2016) Avascular necrosis of lunate bone: Kienbock disease. Am J Emerg Med 34:1185 (e1185 1186) 7. Iorio ML, Kennedy CD, Huang JI (2015) Limited intercarpal fusion as a salvage procedure for advanced Kienbock disease. Hand (N Y) 10:472 476 8. Kolovich GP, Kalu CM, Ruff ME (2016) Current trends in treatment of Kienbock disease: a survey of hand surgeons. Hand (N Y) 11:113 118 9. Spies CK, Hohendorff B, Müller LP et al (2016) Proximal carpal row carpectomy. Oper Orthop Traumatol 28:204 217 10. Unglaub F, Langer MF, Unglaub JM et al (2017) (Partial) fusion of the wrist: indications and surgical procedures. Oper Orthop Traumatol 28:204 217. (Unfallchirurg 120:513 526) 11. Trombetta R, Inzana JA, Schwarz EM et al (2017) 3D printing of calcium phosphate ceramics for bone tissue engineering and drug delivery. Ann Biomed Eng 45:23 44 12. He HY, Zhang JY, Mi X et al (2015) Rapid prototyping for tissueengineered bone scaffold by 3D printing and biocompatibility study. Int J Clin Exp Med 8:11777 11785 451 13. Jeong HS, Park KJ, Kil KM et al (2014) Minimally invasive plate osteosynthesis using 3D printing for shaft fractures of clavicles: technical note. Arch Orthop Trauma Surg 134:1551 1555 14. Xu Y, Li C, Zhu Y (2015) A novel nickel-titanium memory alloy arthrodesis concentrator for the treatment of stage IIIIc aseptic lunate necrosis (Kienbock s disease). J Hand Surg Eur Vol 42:90 103 15. Lutsky K, Beredjiklian PK (2012) Kienbock disease. J Hand Surg Am 37:1942 1952 16. Kuehn BM (2016) Clinicians embrace 3D printers to solve unique clinical challenges. JAMA 315:333 335 17. MacDonald E, Wicker R (2016) Multiprocess 3D printing for increasing component functionality. Science 353:2093 18. Savage N (2016) Technology: the promise of printing. Nature 540:S56 S57 19. Lee N (2016) The Lancet Technology: 3D printing for instruments, models, and organs? Lancet 388:1368 20. Swanson AB, de Groot Swanson G (1993) Implant resection arthroplasty in the treatment of Kienbock s disease. Hand Clin 9:483 491 21. Lippman EM, Mc DL (1949) Vitallium replacement of lunate in Kienbock s disease. Mil Surg 105:482 484 22. Bellemere P, Maes-Clavier C, Loubersac T et al (2012) Pyrocarbon interposition wrist arthroplasty in the treatment of failed wrist procedures. J Wrist Surg 1:31 38