Catheter-Induced Linear Lesions in the Left Atrium in Patients With Atrial Fibrillation An Electroanatomic Study

Similar documents
Since pulmonary veins (PVs) have

Topographic Distribution of Focal Left Atrial Tachycardias Defined by Electrocardiographic and Electrophysiological Data

The pulmonary veins have been demonstrated to often

480 April 2004 PACE, Vol. 27

Trigger Activity More Than Three Years After Left Atrial Linear Ablation Without Pulmonary Vein Isolation in Patients With Atrial Fibrillation

Mechanism of Immediate Recurrences of Atrial Fibrillation After Restoration of Sinus Rhythm

AF :RHYTHM CONTROL BY DR-MOHAMMED SALAH ASSISSTANT LECTURER CARDIOLOGY DEPARTMENT

Radiofrequency ablation for atrial fibrillation

Evidence for Longitudinal and Transverse Fiber Conduction in Human Pulmonary Veins

Atrial Fibrillation: Electrophysiological Mechanisms and the Results of Interventional Therapy

Pulmonary vein isolation (PVI) is

Electrical isolation of the pulmonary veins (PVs) to treat

Supplementary Online Content

Characteristics of Rapid Rhythms Recorded Within Pulmonary Veins During Atrial Fibrillation

Integration of CT and fluoroscopy images in the ablative treatment of atrial fibrillation

Ankara, Turkey 2 Department of Cardiology, Division of Arrhythmia and Electrophysiology, Yuksek Ihtisas

The Who, What, Why, and How-To Guide for Circumferential Pulmonary Vein Ablation

Case Report. Sumito Narita MD 1;3, Takeshi Tsuchiya MD, PhD 1, Hiroya Ushinohama MD, PhD 2, Shin-ichi Ando MD, PhD 3

Specific Linear Left Atrial Lesions in Atrial Fibrillation Intraoperative Radiofrequency Ablation Using Minimally Invasive Surgical Techniques

From the Division of Cardiology, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, Michigan

Radiofrequency Catheter Ablation for Atrial Fibrillation

Peri-Mitral Atrial Flutter with Partial Conduction Block between Left Atrium and Coronary Sinus

Hybrid Ablation of AF in the Operating Room: Is There a Need? MAZE III Procedure. Spectrum of Atrial Fibrillation

Journal of the American College of Cardiology Vol. 45, No. 6, by the American College of Cardiology Foundation ISSN /05/$30.

The impact of hypertension on the electromechanical properties and outcome of catheter ablation in atrial fibrillation patients

Long Standing Persistent AF ; CPVI is enough for it

Circumferential Pulmonary-Vein Ablation for Chronic Atrial Fibrillation

Arrhythmia/Electrophysiology

Noninducibility of Atrial Fibrillation as an End Point of Left Atrial Circumferential Ablation for Paroxysmal Atrial Fibrillation A Randomized Study

A New Approach for Catheter Ablation of Atrial Fibrillation: Mapping of the Electrophysiologic Substrate

AF ABLATION Concepts and Techniques

Electrical disconnection of pulmonary vein (PV) myocardium

Ablation of long-standing AF. Is it wise to pursue it?

Is cardioversion old hat? What is new in interventional treatment of AF symptoms?

Electrophysiologic Properties of Pulmonary Veins Assessed Using a Multielectrode Basket Catheter

AF Today: W. For the majority of patients with atrial. are the Options? Chris Case

1995 Our First AF Ablation. Atrial Tachycardias During and After Atrial Fibrillation Ablation. Left Atrial Flutter. 13 Hours Later 9/25/2009

Case Report Figure-8 Tachycardia Confined to the Anterior Wall of the Left Atrium

ESSA HEART AND VASCULAR INSTITUTE APR/MAY/JUNE 2009 CLINICAL LETTER

Storia dell ablazione della fibrillazione atriale: da dove siamo partiti, dove siamo, dove andremo. Prof. Fiorenzo Gaita

Case 1 Left Atrial Tachycardia

2017 HRS/EHRA/ECAS/APHRS/SOLAECE Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation

Case Report Pulmonary Vein Compression After Implantation of a Left Atrial Appendage Occluder: Presentation and Discussion of a Case

Catheter ablation of atrial macro re-entrant Tachycardia - How to use 3D entrainment mapping -

Catheter Ablation of Atrial Fibrillation

Modification of the Substrate for Maintenance of Idiopathic Human Atrial Fibrillation

How to Distinguish Focal Atrial Tachycardia from Small Circuits and Reentry

AF ablation Penn experience. Optimal approach to the ablation of PAF: Importance of identifying triggers 9/25/2009

Original Article Pulmonary vein isolation without left atrial mapping

Catheter ablation of atrial fibrillation: Indications and tools for improvement of the success rate of the method. Konstantinos P.

Case Report Epicardial Ablation: Prevention of Phrenic Nerve Damage by Pericardial Injection of Saline and the Use of a Steerable Sheath

Role of LAA isolation in AF cure

T he excess mortality associated with atrial fibrillation

Atrial fibrillation (AF) is the most common sustained

Case Report Successful Multi-chamber Catheter Ablation of Persistent Atrial Fibrillation in Cor Triatriatum Sinister

Original Article Short- and long-term experience in pulmonary vein segmental ostial ablation for paroxysmal atrial fibrillation*

How to ablate typical atrial flutter

Atrial fibrillation (AF) is the most common arrhythmia in

Clinical Value of Noninducibility by High-Dose Isoproterenol Versus Rapid Atrial Pacing After Catheter Ablation of Paroxysmal Atrial Fibrillation

Catheter Ablation of Atrial Fibrillation in Patients with Prosthetic Mitral Valve

Case Report Catheter ablation of ventricular tachycardia related to a septo-apical left ventricular aneurysm

Complications During Cardiovascular Interventions: Management and Prevention

Noncontact mapping to idiopathic VT from LCC

Understanding Atrial Fibrillation

Κατάλυση παροξυσμικής κολπικής μαρμαρυγής Ποια τεχνολογία και σε ποιους ασθενείς; Χάρης Κοσσυβάκης Καρδιολογικό Τμήμα Γ.Ν.Α. «Γ.

Peri-mitral atrial flutter in patients with atrial fibrillation ablation

Case Report Electroanatomical Mapping and Ablation of Upper Loop Reentry Atrial Flutter

Ablation of persistent AF Is it different than paroxysmal?

A Narrow QRS Complex Tachycardia With An Apparently Concentric Retrograde Atrial Activation Sequence

Raphael Rosso MD, Yuval Levi Med. Eng., Sami Viskin MD Tel Aviv Sourasky Medical Center

Combined catheter ablation and left atrial appendage closure as a. treatment of atrial fibrillation

Reentry in a Pulmonary Vein as a Possible Mechanism of Focal Atrial Fibrillation

Mapping techniques in AFib. Helmut Pürerfellner, MD Public Hospital Elisabethinen Academic Teaching Hospital Linz, Austria

Linear Ablation Should Not Be a Standard Part of Ablation in Persistent AF. Disclosures. LA Ablation vs. Segmental Ostial Ablation With PVI for PAF

Electrophysiological Characteristics of Atrial Tachycardia After Pulmonary Vein Isolation of Atrial Fibrillation


Catheter Ablation of Atypical Atrial Flutter after Cardiac Surgery Using a 3-D Mapping System

Evaluation of the Recurrence of Atrial Fibrillation After Pulmonary Venous Ablation

Time to recurrence of atrial fibrillation influences outcome following catheter ablation

Long-Term Outcome and Risks of Catheter Ablation for Atrial Fibrillation

Case Report Hemostasis of Left Atrial Appendage Bleed With Lariat Device

Επιπλοκές κατάλυσης πνευµονικών φλεβών

Kadlec Regional Medical Center Cardiac Electrophysiology

Catheter Ablation: Atrial fibrillation (AF) is the most common. Another Option for AF FAQ. Who performs ablation for treatment of AF?

Catheter Ablation of Atrial Tachycardia Originating from the Tip of Right Atrial Appendage

EHRA Accreditation Exam - Sample MCQs Invasive cardiac electrophysiology

This overview was prepared in October 2011, and updated in March 2012.

Atrial fibrillation ablation

Atrial Fibrillation Procedures Data Summary. Participant STS Period Ending 12/31/2016

Invasive and Medical Treatments for Atrial Fibrillation. Thomas J Dresing, MD Section of Electrophysiology and Pacing Cleveland Clinic

Atrial Fibrillation Ablation Using a Robotic Catheter Remote Control System

University of Groningen. Ablation of atrial fibrillation de Maat, Gijs Eduard

Atrial ectopic beats within the pulmonary veins (PVs) are

Atrial Fibrillation Ablation: in Whom and How

Characteristics of systolic and diastolic potentials recorded in the left interventricular septum in verapamil-sensitive left ventricular tachycardia

Ventricular Arrhythmias

Catheter Ablation of Supraventricular Arrhythmias: State of the Art

Catheter Ablation of a Complex Atrial Tachycardia after Surgical Repair of Tetralogy of Fallot Guided by Combined Noncontact and Contact Mapping

What s new in my specialty?

Transcription:

Journal of the American College of Cardiology Vol. 42, No. 7, 2003 2003 by the American College of Cardiology Foundation ISSN 0735-1097/03/$30.00 Published by Elsevier Inc. doi:10.1016/s0735-1097(03)00940-9 Catheter-Induced Linear Lesions in the Left Atrium in Patients With Atrial Fibrillation An Electroanatomic Study Sabine Ernst, MD, Feifan Ouyang, MD, Felix Löber, Matthias Antz, MD, Karl-Heinz Kuck, MD Hamburg, Germany OBJECTIVES BACKGROUND METHODS In this study using radiofrequency current and the electroanatomic mapping system CARTO, four line designs were tested in 84 patients suffering from drug-refractory atrial fibrillation (AFib). Prevention of AFib by trigger elimination within the pulmonary veins (PVs) has been recently reported, but the success may be lesser in patients with chronic AFib or large atria requiring linear lesion deployment. Type A encircled the ostia of all four PVs with a connection to the mitral annulus (MA). In type B, three lines connected anatomic barriers. Type C encircled both septal and lateral PVs with connections between PVs and to the MA. Type D encircled PVs only. In the initial 12 patients (type D/1), line validation was performed without, and in 23 patients (type D/2) with, an additional catheter inside the encircled PVs. RESULTS The ability to achieve completeness of all intended lines was 5% in type A, 21% in type B, 29% in C, 66% in type D/1, and 61% in type D/2. This resulted in stable sinus rhythm in 19% (4/21 patients) in type A, 32% (6/19 patients) in type B, 50% (7/14 patients) in type C, 58% (7/12 patients) in type D/1, and 65% (15/23 patients) in type D/2, respectively, over a mean follow-up of 620 376 days. Besides thromboembolic events (one stroke and one transient ischemic attack), total occlusion of a PV was a major complication in one patient, and acute tamponade in two patients. CONCLUSIONS Complete lesions in the left atrium were difficult to achieve using conventional radiofrequency current technology, but were associated with sinus rhythm in 74% of patients during long-term follow-up, whereas incomplete lesions led mostly to recurrences of AFib or gap-related atrial tachycardia. (J Am Coll Cardiol 2003;42:1271 82) 2003 by the American College of Cardiology Foundation Catheter ablation of atrial fibrillation (AFib) has been attempted by either elimination of the initiating trigger or by modifying the substrate for maintenance of the arrhythmia. Prevention of AFib by trigger elimination within the pulmonary veins (PVs) can be successful in up to 71% of patients (1 3). The success rate may be lower in patients with chronic AFib or large atria mostly due to extra-pv See page 1283 triggers that cannot be ablated during electrophysiological study. Therefore, substrate modification may be mandatory either as primary or as additional treatment after successful isolation of the PVs. We have recently shown that multiple linear lesions may be successfully deployed within the right atrium (RA), but do not prevent AFib episodes in the vast majority of patients (4). Compartmentalization of the left atrium (LA) by surgically deployed linear lesions has prevented AFib episodes (5,6). Application of linear lesions within the LA by catheter techniques has been reported with variable success From the II. Med. Abteilung, Allgemeines Krankenhaus St. Georg, Hamburg, Germany. Drs. Ernst, Ouyang, Antz, and Kuck are trainers of the European Teaching Course of the CARTO system (Biosense Webster, Europe). Manuscript received January 6, 2003; revised manuscript received April 9, 2003, accepted April 17, 2003. (7,8). In those reports, completeness of lines was not validated in detail. Thus, it was unclear whether AFib recurrences were due to incomplete lines or an inadequate line design. Furthermore, incomplete linear lesions predispose to gap-related tachycardia (AT) (9). This paper presents four different line designs within the LA aiming at modification of the myocardial substrate for AFib and/or isolation of PVs in humans. METHODS Patient population. Between June 1997 and August 2000, a total of 84 patients (66 male; mean age, 58.3 8.7 years) underwent primary catheter ablation for AFib in the LA. All patients suffered from either intermittent or chronic symptomatic (n 15) AFib for a mean duration of 10 8 years and were refractory to a median number of four antiarrhythmic agents (including amiodarone in 64 patients). A total of 46 patients had undergone previous ablation procedures that failed to change their arrhythmia: 34 patients an RA linear lesion ablation for AFib, three patients a PV isolation attempt using ultrasound energy, nine patients a bidirectional isthmus blockade for atrial flutter. All patients suffered from symptomatic AFib presenting with symptoms such as palpitations, dizziness, or presyncope despite antiarrhythmic treatment. The ethical committee in Freiburg, Germany, had approved the study

1272 Ernst et al. JACC Vol. 42, No. 7, 2003 Catheter-Induced Linear Lesions in the Left Atrium October 1, 2003:1271 82 Abbreviations and Acronyms AFib atrial fibrillation AT atrial tachycardia CS coronary sinus LA left atrium/atrial LAA left atrial appendage MA mitral annulus PV pulmonary vein RA right atrium/atrial RFC radiofrequency current SR sinus rhythm protocol, and all patients gave their written consent. After exclusion of intracardiac thrombi by transesophageal echocardiography, patients were studied in a fasting state under continuous sedation. Electrophysiologic study. Two standard catheters were positioned: a His bundle recording catheter (Parahis, Biosense Webster, Waterloo, Belgium) advanced via femoral vein access, as well as a multipolar catheter (A 20, Biosense Webster) advanced in the distal coronary sinus (CS) via the left subclavian vein. Subsequently, trans-septal access using a modified Brockenbrough technique was performed and either a single standard 8F sheath (SL1, DAIG, St. Jude Medical, Minnetonka, Minnesota) or a custom-made 11F double sheath system (Cordis Roden, Roden, the Netherlands) was advanced. Using this double-sheath technique (in nine patients of group A and B), the inner preformed sheath guides the catheter tip so that it is in parallel and not tangential orientation to the atrial wall and can be gently dragged along the intended line (10). In type D/2 ablation procedures, a double trans-septal puncture with two 8F sheaths was performed. After trans-septal puncture, activated clotting time was adjusted to 250 to 300 s by repeat intravenous. Heparin bolus throughout the procedure. In addition, a continuous infusion with heparinized saline was connected to the trans-septal sheaths (flow rate 15 ml/h) to avoid thrombus formation or air embolism. Three-dimensional mapping. The electroanatomic mapping system (CARTO) was used to reconstruct the LA, which has been previously described in detail (11). In brief, a 4-mm tip mapping and ablation catheter (NAVI-Star, Biosense Webster) was advanced to the LA via the transseptal sheath. Mapping was performed during stable pacing conditions from the CS or from the RA septum. In case of AFib, sinus rhythm (SR) was restored by external cardioversion. If DC shock failed, intravenous flecainide (up to 1.5 mg/kg body weight, n 12 patients) was administered and cardioversion repeated. After completion of the mapping, all endocardial potentials were manually annotated. Ablation design. Type A consisted of two lines: a circular lesion, which incorporated all PV ostia and a connection from the encircling line (close to the inferior lateral PV) to the mitral annulus (MA) (Fig. 1A). This concept copies the core line of the surgical Maze procedure and interrupts by the lateral connection to the MA the potential macroreentry around the annulus. Type B consisted of three lines: the first connecting the superior septal to the superior lateral PV (roof line), the second connecting the middle of the roof line to the anterior MA, and the third connecting the roof line towards the posterior MA leaving an intentional gap of 2 to 3 cm to allow activation of the LA appendage (Fig. 1B). This design investigates a pure substrate modification attempt without any trigger elimination by PV isolation. Type C consisted of two encircling lines around the septal superior and inferior PV ostia as well as the lateral superior and inferior PV ostia, respectively. In addition, linear connections along the posterior wall between the two encircling lines and towards the lateral MA were deployed (Fig. 1C). This design combines both the PV isolation with the substrate modification attempt to interrupt potential reentry circuits between the PV segments and around the MA. Type D, as type C without the connections between the PV encircling lines (Fig. 1D). After the experience of incomplete lesion deployment in type C, the connections were omitted to avoid iatronegic gap-related tachycardia. Ablation. The linear lesions were applied by moving the ablation catheter along the previously designed lines in temperature-controlled mode (maximum temperature 55 C, maximum duration of 180 s, maximum 50 W). End point for radiofrequency current (RFC) delivery was either the total elimination of the local potential or a maximum of 180 s. In case of an impedance drop by 10, RFC energy was immediately stopped to prevent carbonization at the catheter tip. Line validation. Validation was performed by conventional mapping criteria followed by a repeat threedimensional reconstruction while pacing either from CS or RA septum. In type A, complete lines lead to an isolation of the encircled area, as previously described (10). The electroanatomic activation map showed a sudden change from early to late activation along the ablation line and/or no potentials at all within the isolated area. Conduction gaps were identified by sites with single potentials and by local early activation (Fig. 2A). In type B, completion of the anterior line was characterized by an abrupt change of the activation sequence recorded from the multipolar catheter placed distally in the CS while pacing from the RA septum (Fig. 2B). Furthermore, double potentials could be found along the lines when pacing from sites opposite to the ablation line: from RA septum for the anterior and posterior line and from the CS for the LA roof line. Accordingly, the electroanatomic map showed a sudden change of the local activation times. In type C, isolation of the PV segments was defined by a decrease of local voltage amplitude of 70% within the isolated areas using the amplitude voltage feature of the

JACC Vol. 42, No. 7, 2003 October 1, 2003:1271 82 Ernst et al. Catheter-Induced Linear Lesions in the Left Atrium 1273 Figure 1. Intended line designs: anterior posterior projections of a mesh graph of the electroanatomic mapping system CARTO of an LA with the pulmonary veins (PV) and the trans-septal sheath depicted as colored tubes. Ablation lines are depicted by multiple red dots. (A) A long encircling line around all four PV ostia (roof line) and a connection to the lateral mitral annulus (MA). (B) Roof line between the right and left superior PV ostium. The anterior line connects the middle of the roof line to the superior MA; the posterior line aims at the inferior MA with an intentional gap of approximately 3 cm. (C) Two encircling lines around the ostia of the superior and inferior PVs on both the septal and lateral sides. Additional connections between the PV segments (posterior line), the lateral PV segment, and the MA. (D) Encircling lines around the PVs on both sides without additional connection lines. CARTO system and a cut-off limit of 0.1 mv (12). Completion of the connecting lesions in type C was determined by pacing maneuvers from the proximal and distal CS while recording double potentials along the ablation lines (Fig. 2C). In type D, two different approaches were used: in the initial 12 patients (type D/1), successful encircling of the PV segments was defined as in type C (Fig 2D). In the remaining 23 patients (type D/2), an additional catheter (ParaHis, Biosense Webster, Diamond Bar, California) was placed inside the respective PV before lesion deployment to demonstrate a PV spike potential on one or more bipolar

Figure 2. Line validation (A) pulmonary artery (PA) projection of an activation map of the electroanatomic mapping system in the patient with a single persisting gap in the lateral aspect of the posterior line as depicted by the gradual change of colors at the site of the conduction gap. Complete lesions demonstrate double potential while constantly pacing from the coronary sinus (CS). Continued on next page. 1274 Ernst et al. JACC Vol. 42, No. 7, 2003 Catheter-Induced Linear Lesions in the Left Atrium October 1, 2003:1271 82

JACC Vol. 42, No. 7, 2003 October 1, 2003:1271 82 Ernst et al. Catheter-Induced Linear Lesions in the Left Atrium 1275 Figure 2 Continued. (B) Comparison of the pre- and post-ablation activation map in a left anterior oblique projection for type B. The right-hand panel demonstrates the activation sequence along a multipolar catheter advanced in the distal CS while constantly pacing from the RA septal site. Please note the prolongation of the activation time after complete anterior line deployment in the distal CS electrodes. Continued on next page.

1276 Ernst et al. JACC Vol. 42, No. 7, 2003 Catheter-Induced Linear Lesions in the Left Atrium October 1, 2003:1271 82 Figure 2 Continued. (C) Post-ablation activation map after pulmonary vein (PV) isolation during pacing from the CS catheter shown in a PA projection. Double potentials are marked with blue dots. Continued on next page. electrograms. Validation of the completeness of the encircling PV isolation line was demonstrated by loss or dissociation of the PV spikes (Fig. 2E). Definitions. Lines were classified as being either complete, having a single or multiple conduction gaps. Upon completion of the post-ablation maps, a manual contrast injection in the ostia of all PVs was performed after type C and D line deployment to exclude acute PV stenosis. Follow-up. All patients were initially followed on their previous antiarrhythmic medication that was continued throughout the ablation procedure. Anticoagulation was advised with warfarin (international normalized ratio 2 to 3), or with aspirin (300 mg per day) if the patient refused to take warfarin. One day after the procedure, a 12-lead electrocardiogram (ECG), transthoracic echocardiography, and a 24-h Holter recording were performed. These were repeated after one, three, and six months by the referring physicians or by the ablation center (where all data was collected and reviewed). In case of stable SR after three months, antiarrhythmic medication was discontinued. Pa-

Figure 2 Continued. (D) Comparison of voltage in the pre- and post-ablation maps in a posterior-anterior projection of the LA. The voltage is depicted according to the color spectrum shown in the right upper corner, ranging from low ( 0.1 mv, red) to high-voltage ( 1.5 mv, purple). Continued on next page. JACC Vol. 42, No. 7, 2003 Ernst et al. October 1, 2003:1271 82 Catheter-Induced Linear Lesions in the Left Atrium 1277

1278 Ernst et al. JACC Vol. 42, No. 7, 2003 Catheter-Induced Linear Lesions in the Left Atrium October 1, 2003:1271 82 Figure 2 Continued. (E) Left-hand panel depicts the multipolar catheter in the right upper PV (RUPV) during contrast injection through the second trans-septal sheath. The right panel demonstrates the loss of the PV spike potential (arrow) during radiofrequency current application. Surface lead II, as well as a bipolar electrogram from the 4-mm ablation catheter (Mp), four bipolar electrograms of the PV catheter (from distal to proximal), and from the proximal CS are shown. MA mitral annulus. tients were advised to obtain a 12-lead ECG in case of recurrent palpitations. After completion of the six-month follow-up, patients were contacted and interviewed via telephone at regular intervals. Patients were offered a reattempt at catheter ablation if AFib persisted. Study end points. The primary end point was the complete deployment of the intended ablation lines. Secondary end points were either recurrences of symptomatic or documented AFib, stable SR, and new-onset ATs. Statistical analysis. Continuous variables are expressed as mean 1 SD. RESULTS Procedural data. The 84 patients underwent a total of 107 procedures. The average procedure time was 8.4 1.7 h from sheath insertion to sheath extraction. A mean duration of 33.3 30.5 min of fluoroscopy was used, ranging from up to 145 min (Patient 8) in the first 10 procedures to as low as 7.1 min with increasing experience of the investigators. A mean number of 43.2 15.3 radiofrequency applications were deployed (Table 1). Validation of line completeness and results of follow-up. In type A, a mean number of 49.2 15.7 RFC applications were delivered over a mean total line length of 202 32 mm (185 28 mm for the PV isolation segment) (Table 2, Fig. 3). Complete lines were achieved in a single patient (during the second ablation session). This resulted in the creation of a silent area in the posterior part of the LA (10). In a second patient, a single gap persisted despite multiple radiofrequency applications at the inferior lateral part of the LA (Fig. 2A). In the remaining patients, multiple conduction gaps persisted in the roof (12 patients) and septal (10 patients) lines. During a mean follow-up of 974 408 days, the patient with complete lines remained in SR without antiarrhythmic medication. The patient with the single gap was in SR with frequent atrial extrasystoles on antiarrhythmic medication. Of the 18 patients with incomplete lines, only two were in Table 1. Overview of Patient Demographics and Procedural Data for Each Line Design Type A Type B Type C Type D/1 Type D/2 Total # of patients treated 21 20 (19 ablated) 14 12 23 84 # of procedures 27 20 16 14 30 107 Mean age (yrs) 60 6 56 10 62.1 6.4 54.2 9.6 62.1 6.4 58.3 8.7 Gender (M/F) 19/2 15/4 10/4 7/5 20/3 66/18 AFib duration 11.3 9 8.2 5.9 11.7 10 9.8 6.4 8.7 7.5 9.9 8.2 # of chronic AFib 3 4 4 0 5 15 # of intermittent AFib 18 16 10 12 18 69 Mean number of episodes/months 12 8 16 11 16 11 17 14 16 11 Mean duration of episodes (h) 21 23 20 19 21 20 20 16 26 23 Procedure duration (h) 8.7 1.6 8.8 2 9.4 0.8 7.3 1.5 7.7 1.8 8.4 1.7 Fluoroscopy (min) 63 44.1 29 11.8 19.3 8.4 15.7 6.2 23.2 9.9 33.3 30.5 # of RFC application 49.2 15.7 46.7 15.7 46.4 14.7 33.9 9.0 34.1 16.1 43.2 15.3 Total length of ablation line (mm) 202 32 177 23 309 96 188 36 215 39 Length of PV isolation line(s) (mm) 185 28 septal: 109 28 septal: 101 16 septal: 114 16 lateral: 120 40 lateral: 96 20 lateral: 110 24 Numbers are given as mean SD. AFib Atrial fibrillation; PV pulmonary vein; RFC radiofrequency current.

JACC Vol. 42, No. 7, 2003 October 1, 2003:1271 82 Ernst et al. Catheter-Induced Linear Lesions in the Left Atrium 1279 Table 2. Follow-Up of Treated Patients With Regard to the Respective Ablation Type: Patients Are Categorized With Respect to Results of Line Validation After the Final Ablation Session Type A Type B Type C Type D/1 Type D/2 # of patients treated 21 20 (19 ablated) 14 12 23 # of procedures 27 20 16 14 30 Mean follow-up duration 974 408 827 330 511 142 400 126 324 140 Complete lines (n) with 1/20 4/19 4/14 8/12 14/23 rhythm outcome 1 pt SR 3 pts SR AES 3 pts SR 4 pts SR 12 pts SR 1 pt i.afib 1 pt AFib 4 pts AFib 2 pts AFib Incomplete lines (n) with 19/20 15/19 10/14 4/12 9/23 rhythm outcome 3 pts SR (single gap: 1 pt SR 2 pts SR 3 pts SR 3 pts SR SR AES) 14 pts AFib 12 pts AFib 6 pts AFib 1 pt AFib 6 pts AFib 2 pts AT 2 pts AT 2 pts AT AA-TX antiarrhythmic medication; AES atrial extrasystoles; AFib atrial fibrillation; AT atrial tachycardia; i.afib intermittent atrial fibrillation; pt patient; SR sinus rhythm. SR, but 14 patients experienced recurrences of AFib (one patient underwent a second ablation attempt with design C). Two patients (with multiple gaps) presented with incessant atrial macroreentrant tachycardia around the MA and underwent subsequent successful ablation. In type B (Fig. 3B), a mean number of 46.7 15.7 RFC applications were given over a mean total line length of 177 23 mm. All three lines could be successfully deployed in four patients (in all these patients the custom-made double sheaths were used). Despite multiple RFC applications, conduction gaps persisted in 15/19 patients, at the roof line in 11 patients and the anterior line in eight patients. During follow-up (827 330 days), complete lines resulted in SR with occasional atrial extrasystoles in three patients, whereas the remaining patient changed from chronic to intermittent AFib on antiarrhythmic medication. Only one patient with incomplete lesions remained in SR; all other patients had recurrences of AFib on their medication. Two patients suffered from incessant LA macroreentrant tachycardia due to persisting gaps in either the roof or anterior line and underwent subsequent successful ablation. In type C (Fig. 3C), a mean number of 46.4 14.7 RFC applications were delivered over a mean line length of 308 96 mm (109 28 mm and 120 40 mm for the septal and lateral PV isolation segment, respectively). Complete encircling of the septal PV ostia was achieved in all 14 patients. The lateral encircling line was incomplete in nine patients, with conduction gaps located close to the base of the left atrial appendage (LAA). The connections between the PV segments towards the mitral annulus were incomplete in seven patients. Overall, lines were complete in only four patients, whereas, in the remaining 10 patients, multiple conduction gaps persisted despite repeat RFC applications. During a follow-up of 511 142 days, three of the four patients with complete lines remained in SR without antiarrhythmic medication. Of the remaining patients, only two were in SR, whereas six patients had recurrences of AFib. Two patients with incomplete connections towards the MA had incessant AT and underwent subsequent catheter ablation. In type D/1 (Fig. 3D), a mean number of 33.7 9.0 RFC applications were delivered over a mean total line length of 188 36 mm (101 16 mm and 96 20 mm for the septal and lateral PV isolation segment, respectively). Complete encircling was achieved around the septal PVs in all patients, around the lateral PVs in 7/12 patients. After two repeat procedures, this segment was completed in one more patient. During a follow-up of 400 126 days, four of the eight patients with complete linear lesions were in stable SR without antiarrhythmic medication, whereas four patients had persistent AFib episodes despite continued antiarrhythmic medication. Three of the four patients with an incomplete lateral PV segment remained in SR. In type D/2 (Fig. 3E), a mean number of 34.1 16.1 RFC applications were given over a mean total line length of 215 39 mm (114 16 mm and 110 24 mm for the septal and lateral PV segment, respectively). Complete PV encircling was achieved in all but one patient for the septal segment, but remained incomplete in 10/23 patients for the lateral segment after the initial ablation procedure. In repeat procedures this linear lesion was completed in four additional patients. During a mean follow-up of 324 140 days, 12/14 patients with complete lines remained in stable SR, whereas only 3/9 patients with incomplete lines remained arrhythmia-free. Complications. In two patients (type A and B) transseptal puncture resulted in acute tamponade, requiring immediate pericardiocentesis. One patient (type A) underwent the same procedure four weeks later; the other shifted to type C six months later. Although no impedance rise had been evident during the ablation session, one patient (type A) suffered a stroke, leading to vision disturbances within 48 h after the procedure, and one patient (type D/2) suffered a transient ischemic attack (without morphologic changes in sequential computed tomography scans). The symptoms resolved gradually during follow-up. In one patient of group

1280 Ernst et al. JACC Vol. 42, No. 7, 2003 Catheter-Induced Linear Lesions in the Left Atrium October 1, 2003:1271 82 Figure 3. (A to E) (alternative to Table 2) Follow-up of treated patients using the respective ablation type. Patients are categorized with respect to results of line validation after the final ablation session. AA-TX antiarrhythmic medication; AES atrial extrasystoles; AFib atrial fibrillation; AT atrial tachycardia; i. AFib intermittent atrial fibrillation; SR sinus rhythm. D/2, a 40% stenosis of the right upper PV was demonstrated at the end of the ablation session but remained asymptomatic during follow-up. One patient of group D/1 developed shortness of breath (initially only on exertion) after an uneventful follow-up period of six months. Because of increasing hemoptysis, the patient underwent repeat bronchoscopies and finally an explorative mediastinoscopy for suspicion of bronchial neoplasm. After transfer to the ablation center, transesophageal echocardiography did not demonstrate any flow in the right upper PV. Direct angiography depicted a totally occluded right upper PV, which was subsequently recanalized and dilated. However, despite

JACC Vol. 42, No. 7, 2003 October 1, 2003:1271 82 Ernst et al. Catheter-Induced Linear Lesions in the Left Atrium 1281 antiplatelet and anticoagulation therapy, re-stenosis occurred, necessitating repeat balloon dilation and, finally, stent implantation. DISCUSSION We have recently shown that linear lesions within the RA can be successfully deployed and validated using the electroanatomic mapping system (4). In contrast with previously reported data (8,13), RA linear lesions did not prevent AFib recurrences, even when these lesions were complete. Therefore, this study focused on the efficacy of linear lesions within the LA. As in the RA study, the electroanatomic mapping system was used for lesion deployment. Special care was taken on line validation by conventional electrophysiologic criteria and the use of the electroanatomic mapping system, which might explain the difference in procedure time and RFC delivery in other studies (8,12). The first line design (type A) was intended to compartmentalize a large part of the LA including all four PVs, and, thereby, copy the core line of the maze operation. This long single ablation line could only be completed in one of 18 patients, who stayed in SR. All other patients were left with incomplete lines. All except two had recurrences of AFib or AT. The second line design (type B) was aiming solely at the interruption of possible macro re-entries around anatomic barriers such as PV ostia or the MA. However, the only line that could be completed in 15/19 patients (79%) was the anterior line. In contrast, the roof line turned out to be very difficult, which was mostly due to catheter instability. Catheter stability was enhanced by the use of the double sheath technique allowing a parallel rather than tangential catheter tip orientation at the roof line. As before, complete lines were associated with freedom from AFib recurrences. In type C, encircling of PV segments may also eliminate triggers from within the PVs. Each ablation segment had a shorter lesion length (approximately 11 cm) and, thereby, was easier to achieve. Inability to encircle the lateral PVs can be explained by the anatomic location of the intended line between the ostium of the lateral PVs and the base of the LAA (14). The connections were intended to prevent possible macro re-entry around the newly preformed barriers and the MA. These connections were extremely difficult to achieve and remained incomplete in a large proportion of patients (50%), causing iatrogenic gaprelated tachycardia during follow-up. Therefore, in type D, the additional connections between the PVs were omitted. During follow-up in type D/1, the validation criterion of the reduced signal amplitude ( 70% reduction as compared with the pre-ablation map and a cut-off value of 0.1 mv) proved not to be discriminative because only 4/8 patients with complete PV lesions remained in SR, whereas 3/4 patients with incomplete lesions were also in SR. In type D/2, loss of the PV spike potential as the ablation end point demonstrated an improved discriminative power: 12/14 patients with complete linear lesions stayed in SR, compared with only 3/9 patients with incomplete lesions. In contrast, when the end point was only amplitude reduction, no correlation was found between completeness of lines and maintenance of SR. These findings are not in agreement with previously published data (12). Although there might be a small difference in the ablation design (separate isolation of each PV as compared with an encircling line around both upper and lower PVs), RFC delivery is extremely short (15 to 30 s) and might not even result in a transmural lesion or have an effect on epicardially located autonomic nervous endings. The high incidence of incomplete ablation lines using a solid 4-mm tip electrode demands further technological improvement. The use of custom-made sheaths improved the catheter-tissue contact, especially at the roof line. Other techniques, such as irrigated tip catheters, were not available at the time of study, but may improve lesion deployment significantly and lower the risk of thromboembolic complications, which was 2.4% in this study. Although the ablation lines were designed to be at the atrial side, PV occlusion occurred in one patient. Even using the enhanced mapping and navigation tools of the electroanatomic mapping system, assessment of the complex threedimensional anatomy of the PV-LA junction is difficult, and intrapulmonary ablation cannot be ruled out because distinctive markers for the PV ostia are missing. Even more disturbing, PV occlusion developed slowly. The symptoms such as hemoptysis and shortness of breath were, in our patient, not related to the ablation procedure by the initially involved physicians and led to numerous procedures before the diagnosis of PV occlusion was made. Study limitations. The evidence of complete linear lesions at the end of the ablation session may only be a transient phenomenon, and re-conduction may occur during followup, which may account for recurrences, although complete lines were acutely demonstrated. On the other hand, RFCinduced lesions may mature after the ablation session, accounting for the effective treatment of patients defined as incomplete. Finally, the growing experience of the investigators in deploying linear lesions in the LA using sequential RFC applications have to be taken into account when judging the effectiveness of the line designs. Conclusions. Complete lesions in the LA were difficult to achieve using conventional RFC technology, but were associated with SR in 74% of patients during long-term follow-up, whereas incomplete lesions led mostly to recurrences of AFib or gap-related AT. Further technological improvement (catheter design, ablation energy, specifically designed trans-septal sheaths) is necessary to improve line completeness and to facilitate line deployment. Reprint requests and correspondence: Dr. Karl-Heinz Kuck, AK St. Georg, 2. Med. Abteilung (Kardiologie), Lohmühlenstr. 5, 20099 Hamburg Germany. E-mail: sernst1708@aol.com.

1282 Ernst et al. JACC Vol. 42, No. 7, 2003 Catheter-Induced Linear Lesions in the Left Atrium October 1, 2003:1271 82 REFERENCES 1. Oral H, Knight BP, Tada H, et al. Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation. Circulation 2002;105: 1077 81. 2. Shah DC, Haïssaguerre M, Jais P, et al. Curative catheter ablation of paroxysmal atrial fibrillation in 200 patients: strategy for presentations ranging from sustained atrial fibrillation to no arrhythmias. Pacing Clin Electrophysiol 2001;24:1541 58. 3. Chen SA, Hsieh MH, Tai CT, et al. Initiation of atrial fibrillation by ectopic beats originating from the PVs: electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation. Circulation 1999;100:1879 86. 4. Ernst S, Schlüter M, Ouyang F, et al. Modification of the substrate for maintenance of idiopathic human atrial fibrillation. Circulation 1999; 100:2085 92. 5. Cox JL, Boineau JP, Schuessler RB, et al. Five-year experience with the maze procedure for atrial fibrillation. Ann Thorac Surg 1993;56: 814 23. 6. Kottkamp H, Hindricks G, Hammel D, et al. Intraoperative radiofrequency ablation of chronic atrial fibrillation: a left atrial curative approach by elimination of anatomic anchor reentrant circuits. J Cardiovasc Electrophysiol 1999;10:772 80. 7. Haïssaguerre M, Jais P, Shah D, et al. Right and left atrial radiofrequency catheter therapy of paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol 1996;12:1132 44. 8. Pappone C, Oreto G, Lamberti F, et al. Catheter ablation of paroxysmal atrial fibrillation using a 3D mapping system. Circulation 1999;100:1203 8. 9. Duru F, Hindricks G, Kottkamp H. Atypical left atrial flutter after intraoperative radiofrequency ablation of chronic atrial fibrillation: successful ablation using three-dimensional electroanatomic mapping. J Cardiovasc Electrophysiol 2001;12:602 5. 10. Ernst S, Ouyang F, Schneider B, Kuck KH. Prevention of atrial fibrillation by complete compartmentalization of the LA using a catheter technique. J Cardiovasc Electropysiol 2000;11:686 90. 11. Shpun S, Gepstein L, Hayam G, Ben-Haim SA. Guidance of radiofrequency endocardial ablation with real-time three-dimensional magnetic navigation system. Circulation 1997;96:2016 21. 12. Pappone C, Oreto G, Rosanio S, et al. Atrial electroanatomic remodeling after circumferential radiofrequency pulmonary vein ablation: efficacy of an anatomic approach in a large cohort of patients with atrial fibrillation. Circulation 2001;104:2539 44. 13. Gaita F, Riccardi R, Calo L, et al. Atrial mapping and radiofrequency catheter ablation in patients with idiopathic atrial fibrillation: electrophysiological findings and ablation results. Circulation 1998;97:2136 45. 14. Ho SY, Sanchez-Quintana D, Cabrera JA, Anderson RH. Anatomy of the LA: implications for radiofrequency ablation of atrial fibrillation. J Cardiovasc Electrophysiol 1999;10:1525 33.