The first oximetry system to put regional oximetry, pulse oximetry and ease of use at your fingertips.

Similar documents
SenSmart Model X-100. The first oximetry system to put regional oximetry, pulse oximetry and ease of use at your fingertips.

SenSmart. Universal Oximeter System W: E: T: F:

Nonin Medical OEM Pulse Oximetry Solutions. Superior Performance for Challenging Patient Conditions

Chandra Ramamoorthy MBBS; FRCA (UK) Professor of Anesthesiology, Stanford University. Director of Pediatric Cardiac Anesthesiology

INVOS System Inservice Guide for Pediatric Use. INVOS System Inservice Guide for Pediatric Use

pulse oximetry sensors 2007

TruSignal SpO2 Sensors

GE Healthcare. Ohmeda TruSat For wherever your patients take you

Trust Nonin Oximeters, Even For Your Sickest Patients

Too Good to be True? Three Ways Cheap Pulse Oximeters Could be Short-changing Your Patients and Profits

Evaluation of the EQUANOX, FORE-SIGHT and INVOS Systems at St. Francis Hospital in Columbus, GA 1

NEONATAL MONITORING IN-SERVICE GUIDE

3880 PORTABLE MRI MONITORING SYSTEM

Choosing Mindray SpO2

Reliable versatility. Philips HD5 ultrasound system

TECHNOCARE MEDISYSTEMS

All motion is not created equal.

INTERCHANGEABLE HEAD SYSTEM. Easily and quickly change between caries diagnosis and intraoral imaging. T r i t o n H D

61% SvO 2. Clarity. Simplified.

Rediscover dreams. Key Content. DreamStation. Sleep therapy system

Cogent 2-in-1 Hemodynamic Monitoring System

Superior Performance. Lower Dose.* 1,2. World s first and only. 3D breast biopsy. Breast Biopsy Guidance System. Affirm

Versatile, affordable ultrasound. Philips HD6 ultrasound system. The print quality of this copy is not an accurate representation of the original.

Where experience connects with innovation

Oxygen Saturation Monitors & Pulse Oximetry. D. J. McMahon rev cewood

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

Sleep diagnostics systems

ultrasound your way Sharp images. Easy workflow. Fast support. SonixTablet Mountable ultrasound system with a 19 touch screen

Key Content. DreamStation. Sleep therapy system. Rediscover dreams

Rediscover dreams. Key Content. DreamStation. Sleep therapy system

X Series Extensive Capabilities

A Smart Investment in Surgical Versatility

Contour Your Body Quickly and Comfortably!

SURETEST Torque Calibration System

SUBJECT INFORMATION AND CONSENT FORM

InTouch Center Local Customer Teams InTouch Agreements Parts Support

Ultrasound. Sparq. A new way of. thinking. Philips Sparq emergency medicine ultrasound system

One intelligent solution

Ultrasound. Sparq. A new way of. thinking. Philips Sparq critical care ultrasound system

Monitoring Equipment. Blood Pressure Monitor Upper Arm Type: Image (Image not to scale)

SURETEST Torque Calibration System

CS 3600 / CS 3600 ACCESS A SMARTER WAY TO SCAN INTRAORAL SCANNING

61% SvO 2. Clarity. Simplified.

Rediscover dreams. Key Content. DreamStation. Sleep therapy system

Philips Respironics 1010 Murry Ridge Lane, Murrysville, PA USA. Broudy JS 10/12/15 MCI PN

CEREBRAL oximetry using near-infrared spectroscopy

The Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems

Measuring Heart Rate and Blood Oxygen Levels for Portable and Wearable Devices

GE Healthcare. LOGIQ Book XP. Innovation in compact ultrasound

Defibrillators TEC-8300K series. Improving quality of resuscitation

Soft tissue biopsy needles

Xperius Ultrasound System Responsive Advanced Simple NEW

Dräger Alcotest 6820 Alcohol Screening Device

Spirodoc. 3D Laboratory for respiratory analysis two functional modes: doctor and patient. Four devices in one. Spirometer with Touch Screen display

powerful versatile mobile

Vivid S6. Cardiovascular ultrasound system. GE Healthcare. Davis Medical

S Y N C H R O N Y R E S P I R A T O R Y T R A C K I N G S Y S T E M

siemens.com/nx3 Scan Smarter. ACUSON NX3 Series

Absolute Cerebral Oximeters for Cardiovascular Surgical Cases

Lumis Tx: the all-in-one hospital ventilation solution

Soft tissue biopsy needles

Automated Blood Pressure Monitor

Surgical Monitoring Mouse and Rat Made Easy

Cardiocap/5. GE Healthcare. The compact, all-in-one, critical care monitor. Features. Available options

Versana Premier. Care with Confidence. gehealthcare.com

How Does Pulse Oximetry Work? SpO2 Sensors Absorption at the Sensor Site Oxyhemoglobin Dissociation Curve

Near Infrared Spectroscopy in Medical Diagnostics

Competitive Intelligence Report Technology & Patents

SETTING THE STANDARD

Clinically Available Optical Topography System

Introducing the future of DXA. Powerful images. Clear answers. Horizon DXA System

ZONARE Ultrasound for the Emergency Department. Living Technology

CS Introducing the CS 1600 Intraoral Camera Revolutionary technology. Superior workflow.

ELECTRONIC PIPETTE. The electronic pipette with guaranteed performance in both standard and repetitive pipetting. PRECISE EASY-TO-USE RELIABLE

VITA Easyshade Advance 4.0 Determine and verify tooth shades with digital precision.

Icon specifications. Handpiece compatibility

Edwards FloTrac Sensor & Performance Assessments of the FloTrac Sensor and Vigileo Monitor

DIGITAL AUTO-TRAK + Bi-FLEX + AUTO Bi-LEVEL THE POWER OF. Sometimes when three come together the results can be quite extraordinary. Unique even.

PageWriter. TC30 Cardiograph. In touch with you. The print quality of this copy is not an accurate representation of the original.

PINPOINTING RADIATION THERAPY WITH THE PRECISION OF MR.

Near-Infrared Monitoring of Brain and Tissue Oxygenation: Is the Monitor on the Right Person?

THE NEW HOME FOR C-FLEX IS BUILT ON THE IDEA THAT A BETTER NIGHT S SLEEP COMES FROM PRODUCTS THAT ARE EASY TO USE.

EXPERIENCE THE WORLD S FIRST TRULY SMART HEARING DEVICE

Radiation Oncology. The conf ident path to treatment Philips Radiation Oncology Solutions

Integra. Limit uncertainty by simplifying operation and maximizing performance with NXT Digital Architecture

Evaluation of Pediatric Near-Infrared Cerebral Oximeter for Cardiac Disease

Our Vision That no patient is harmed by undetected tissue hypoxia.

Confident and Conclusive Diagnosis with Flexible Solutions

CARESCAPE Patient Data Module

CEREBRAL OXIMETRY IN INFANTS WITH HIE DAPHNA YASOVA BARBEAU, MD FN3 MEETING 2018

SEAL OF EXCELLENCE Henry Schein. Thermometers Oral 416. Aural Touch free 461, THERMOMETERS ALL PRICES EXCLUDE VAT

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

ERS 2 CARDIAC REHABILITATION M O V I N G T O H E A L T H

Delivering Top Performance. Outstanding Value. Exceptional Reliability. ACUSON X150 Ultrasound System. Answers for life.

Rigel UNI-SiM Lite. The most cost-effective patient simulator on the market. Key Features n Compact and cost-effective

2017/8/23 1. SE-2003&SE-2012 Holter Analysis System

One intelligent solution

Defibrillators TEC-8300K series. It s all seamless

Carina. The compact wonder. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Relax, you re in safe hands EMBLETTA MPR

Transcription:

Model X-100 Universal Oximetry System for Pediatric Patients The first oximetry system to put regional oximetry, pulse oximetry and ease of use at your fingertips.

NIRS [near-infrared spectroscopy] has been shown in multiple prospective observational studies to identify circulatory inadequacy in specific organ systems, such as the brain, kidney, and gut. 1 Introducing the SenSmart Universal Oximetry System: Where advanced clinical utility meets unprecedented ease of use One test drive with the world s first universal oximetry system and you know the future is in your hands. With an innovative design that pairs simple with smart, Nonin Medical s SenSmart Model X-100 Universal Oximetry System is a new technology platform that, for the first time, delivers both pulse and regional oximetry measurements today, and is designed to accommodate many more parameters in the future. This is just one of many reasons to re-evaluate your options in regional tissue and pulse oximetry. More insight from multiple oxygen saturation data points. Now, one system provides a side-by-side view of regional oximetry (rso 2), pulse oximetry (SpO 2) and pulse rate values for real-time decision making. The SenSmart System lets you use any combination of Nonin SenSmart-compatible rso 2 sensors and/or SpO 2 sensors with any Nonin SenSmart signal processor to monitor up to six sites on a patient. What s more, SenSmart s universal signal processors are considerably smaller, lighter and less intrusive than anything you have used before. Plus, they automatically recognize and display all of your oximetry values on the SenSmart monitor. Today: Side-by-side view of rso 2 and SpO 2 You now have the opportunity to explore what a gradient between rso 2 and SpO 2 might tell you. rso 2 values allow management of patients at risk for compromised oxygen saturation of the brain or other tissues. SpO 2 and pulse rate values can help to proactively identify oxygen delivery issues for early intervention. EQUANOX Advance Model 8004CB-NA sensor shown 2 NONIN MEDICAL NONIN MEDICAL 3

Introducing Nonin Medical s Dynamic Compensation TM * The first cerebral oximetry algorithm to automatically account for developing neonatal/pediatric brain tissue Dual emitters. Dual detectors. A singular NIRS breakthrough in neonatal and pediatric cerebral/somatic oximetry The optical properties of brain tissue change significantly during the first few months of life. The SenSmart Universal Oximetry System, combined with EQUANOX regional sensor technology, effectively isolates targeted tissue and automatically takes into account the light attenuation changes caused by myelination variation and other developmental changes, providing you with data you can act on. Figure 1 Myelination development changes the optical properties of the pediatric brain and can vary from patient to patient. Node of Ranvier Compacted Myelin Myelin Sheath Axon Oligodendrocyte Peroxisomes To measure blood oxygen saturation levels, cerebral and somatic oximeters must separate the optical effects of blood from tissue. Traditional regional oximetry systems utilize differentsized sensors or manual entry of patient age and weight. No such steps are required with Nonin s Dynamic Compensation algorithm. Figure 2 Infants of the same age can be very different developmentally. Nonin s exclusive EQUANOX technology reduces inaccuracies caused by light scattering effects from non-targeted tissue. Dual emitters/detectors in the EQUANOX Advance sensor create pairs of reflected light paths through surface tissue and through the cerebral cortex, producing measurements that are minimally affected by intervening tissue or surface effects. Four-wavelength algorithms translate light information into accurate measurements. The light absorption information collected by the dual emitter/detector architecture is automatically incorporated into Nonin s Dynamic Compensation light processing algorithm, to provide real tissue oxygenation saturation values based on the patient s unique brain development characteristics. A real-time measurement. A real improvement over trending-only technology. The SenSmart signal processing data provides the actual percent of oxygenated hemoglobin in the target tissue for display on the monitor. The system s accuracy is not just tied to the amount of change from specific patient s baseline. This improved accuracy makes it possible to rely on the values, even when no baseline value is available. Figure 3 EQUANOX rso 2 Sensor Technology Light Emitter Light Detector Light Detector Only Nonin s sensors use two emitters and two detectors to provide cerebral cortex measurements that are minimally affected by intervening tissue or surface effects. 2 Figure 4 Competitors rso 2 Sensor Technology Light Detector Light Detector Light Emitter Light Emitter Other sensors use only one emitter and one or two detectors (examples include CASMED FORE-SIGHT and Covidien INVOS ) and have significantly greater signal contamination from shallow tissue. 2 *Patent-pending 4 NONIN MEDICAL NONIN MEDICAL 5

Clinically proven accuracy, consistency and reliability Instant, absolute rso 2 accuracy from EQUANOX technology Davie SN, Grocott HP 2 The EQUANOX contains two light emitters which may provide further accuracy by allowing this device to account for extracranial tissue variation and contamination throughout the entire curvilinear path... The INVOS demonstrates a relatively short distance between its near and far field detectors this appears to be insufficient to appropriately distinguish extracranial from cerebral tissue. 2 Study Results/Conclusions The primary objective of this study was to determine which NIRS-derived cerebral oxygen saturation technology best eliminates signal contamination from extracranial tissue. 35% 30% 25% 20% 15% 10% 5% 0 Percent change from baseline after occlusion for 5 minutes (%) 11.8 ± 5.3 p = 0.0487 p = 0.025 p = 0.0019 16.6 ± 9.6 6.8 ± 6.0 FORE-SIGHT INVOS EQUANOX This study showed in a statistically significant manner that of the three cerebral oximeters, EQUANOX technology had the least interference from extracranial tissue. Figure 5 Percent change from the baseline regional cerebral oxygen saturation measurement of FORE-SIGHT, INVOS 5100-PB, and EQUANOX Classic 7600, after occlusion of the head cuff for 5 minutes. 2 Kreeger R, et al 3 Accuracy is improved by using more wavelengths, more source-detector separations... dual-emitter/dual-detector sensor and dynamic compensatory algorithms more effectively eliminate scalp and skull contamination to focus on brain tissue and automatically adjust for variations in tissue optical properties to improve accuracy over a wide range of age and physiologic condition. 3 Study Results/Conclusions This is the largest published multicenter study to date calibrating and validating an advanced technology NIRS cerebral oximeter for use in children with congenital heart disease. This cerebral oximeter accurately measured the absolute value of cerebral saturation in children over a wide range of oxygenation and subject characteristics, offering advantages in assessment of cerebral hypoxia-ischemia in congenital heart disease. The accuracy was consistent, even in low saturation, and the researchers did not detect any impact of skin color, age or gender. NIRS Cerebral Oxygenation rso2 (%) 40 60 80 100 20 EQUANOX 8004CB Sensor Series rso 2 Reading vs. Invasive Estimated SavO 2 20 40 60 80 100 Invasive SavO 2 (%) Figure 6 Eighty-six congenital cardiac patients were evaluated, from neonate through pediatrics, with varying skin color and a wide range of SavO 2 representative of typical patient physiology. Simultaneous arterial and jugular bulb samples were analyzed by CO-oximetry. Cerebral oxygen values were taken at the same time with the EQUANOX 8004CB sensor series. 3 Accurate, dependable SpO 2 readings from PureSAT technology SpO 2 Accuracy 6 NONIN MEDICAL Nonin Pulse Oximetry System with PureSAT technology had excellent accuracy Study Results/Conclusions Twelve healthy subjects underwent a standard breathdown protocol to achieve arterial oxygen saturation between 70% and 100%. SpO 2 values were compared to the gold-standard, which is CO-oximetry analysis of arterial blood samples. throughout all saturation levels. Accuracy a combined measure of error and variability was excellent with the Nonin oximeter and sensor in all subjects throughout the most challenging environments. Figure 7 Differences between the Nonin PureSAT SpO 2 technology and CO-oximeter values. Nonin PureSAT SpO 2 technology demonstrated consistent accuracy even at low saturations. 4 NONIN MEDICAL 7

Accuracy you can act on in regional oximetry Accuracy you can act on in pulse oximetry Nonin s EQUANOX Advance Model 8004CB sensor represents a major step forward in pediatric patient monitoring because it provides a single-sensor solution designed specifically for pediatric patients. Until now, most pediatric cerebral/somatic oximetry sensors have essentially been trimmed versions of adult sensors. Nonin s clinically proven PureSAT pulse oximetry technology utilizes intelligent pulse-by-pulse filtering to provide precise oximetry measurements when combined with Nonin s reusable soft SpO2 sensors. Result: Fast, accurate and reliable readings even in patients with low perfusion or in the presence of motion. The sensor features adhesive and non-adhesive versions, a small footprint for spacesaving placement, and light path spacing for pediatric-appropriate tissue depth readings. Nonin s patent-pending Dynamic Compensation algorithm automatically calculates accurate, patient-specific values. And, because the EQUANOX 8004CB provides a single-sensor solution for all patients less than 40 kg, it simplifies protocols and inventory requirements, saving time and money. In addition, there is no need to input patient age and weight. The SenSmart System s EQUANOX Advance rso2 sensors are spatially resolved to calculate accurate, patient-specific values. The rso2 display refreshes every 1.5 seconds, so if tissue saturation is changing, you will see it when it happens. SenSmart EQUANOX rso2 Sensors EQUANOX Advance Model 8004CA (adhesive), 4-wavelength sensor. For patients >40 kg Depth of measurement ~20 mm 20 mm 20 mm SenSmart Soft SpO2 Sensors 8100SL Large Soft Sensor Digit thickness: 12.5 to 25.5 mm (0.5 to 1 in) SENSORS SHOWN ACTUAL SIZE 40 mm 40 mm EQUANOX Advance Model 8004CB (adhesive), and EQUANOX Advance Model 8004CB-NA (non-adhesive), 4-wavelength sensors. For patients <40 kg Depth of measurement ~12.5 mm Somatic placement options for clinical flexibility 12.5 mm Digit thickness: 10 to 19 mm (0.4 to 0.75 in) 12.5 mm 25 mm 25 mm 8 8100SM Medium Soft Sensor 8100SS Small Soft Sensor Digit thickness: 7.5 to 12.5 mm (0.3 to 0.5 in) Note: A 3-wavelength trending sensor for patients >40 kg is also available upon request: EQUANOX Classic Plus Model 8003CA NONIN MEDICAL NONIN MEDICAL 9

Unprecedented ease of use The beauty of working smarter rather than harder Monitor Color-coded display automatically recognizes and Easy-to-read, configurable trend lines (rso 2 ) From a portable monitor to smaller signal processors to interchangeable rso 2 and SpO 2 sensors, the SenSmart System brings new possibilities that support your decision-making process today, and provides a platform for adding more parameters in the future. Signal Processors Smaller (33 cc) and less bulky (40 g/1.4 oz) signal processors are easy to work around, easy to move around and will not get in your way. Ideal for use in a variety of settings including neonatal incubators and minimum space-on-bed situations. Fast start-up and fast signal acquisition deliver readings within seconds. Turn the system on and start monitoring. rso 2 Sensors Flexible sensors conform easily to patient anatomy. Adhesive and non-adhesive options for neonate/ infant/pediatric patients. Center orientation of the rso 2 sensor cables allows for directing cables over the patient s forehead, preventing sideways torquing on the sensor cable or pressure against skin surfaces with sideways movement of the head. Immune to the effects of ambient light; no need to cover the exposed sensor and surrounding skin with a light-shielding drape. Skin color or pigmentation has not been shown to affect the accuracy of the readings. Easy to use, the color-coded and numbered universal signal processors connect to any of the six hub ports. Channels will display properly without any need to connect to the hub in any certain order. Sensor-lock eliminates disconnections. Hub rso 2 Sensors Signal Processors SpO 2 Sensor Monitor SpO 2 Sensors High-intensity pure light spectrum eliminates variations in readings from patient-to-patient and sensor-to-sensor. Fast, accurate SpO 2 readings. Reusable with a durable design and comfortable fit for continuous monitoring. displays signal processor channel number, oximetry type (rso 2 and/or SpO 2 ), and lets you select or customize display of sensor site per channel. In multi-sensor situations you can quickly identify which sensor is which channel, so you can focus on the patient, not the monitoring system. Intuitive, easy-to-operate user interface includes optional patient I.D. capability, as well as the ability to scroll back in the case and/or instantly retrieve a table of event values recorded. Weight advantage: 900 g (2 lbs) versus the 6.85 kg (14 lbs) of other regional oximetry systems currently on the market. Up to 10 customizable presets allow quick start, even when departments or individual clinicians have unique preferences. A major advancement for clinicians dissatisfied with one-configuration-fits-all. Cables 4-meter hub cables allow flexibility in system placement; plus 1- or 2-meter signal processor extension cables increase range when needed. Thin, durable sensor cables shielded from ambient electronic signals; ideal for use in a variety of settings including OR, ICU, Electrophysiology and NICU. and plethysmography displays (SpO 2 ) for a quick visual reference. Data transport to electronic medical record (EMR) systems via the hospital s interface engines. Long battery life (three hours when operating with two channels) makes it suitable for easy transport in and outside of the hospital. Up to 840 hours of data memory and SenSmart Download Software for case analysis, record keeping or research. State-of-the-art Bluetooth wireless connectivity allows you to download cases without a connecting cable. Designed to work with the Philips IntelliBridge interface and Philips IntelliVue patient monitors to provide parameter and trend line display. Display can operate in eight different languages. Portable, Pole-Mountable Monitor THIS PART OF PAGE WILL BE CUT AWAY Form fitted to decrease ambient 10 NONIN MEDICAL light interference. Available in three patient sizes. NONIN MEDICAL 12

Compare oximetry systems Feature for feature Nonin Medical SenSmart Model X-100 Universal Oximetry System Covidien INVOS rso 2 System CASMED FORE-SIGHT rso 2 Oximeter System THIS PART OF PAGE WILL BE CUT AWAY Monitor System Weight 900 g / 2 lbs 6.85 kg / 14 lbs 6.85 kg / 14 lbs Maximum channels 6 4 2 Battery life 3 hours (when operating with 2 channels) 20 minutes 1.5 hours Battery design Lithium ion Lead-acid Lead-acid Battery re-charge time 2.5 hours 24 hours 16.5 hours Instant reading Yes No* No Signal processor/pre-amp size (Approx.) 33 cc 318 cc 121 cc Operational Parameters Display range of rso 2 0 100% 15 95% 0 99% Display range of SpO 2 0 100% n/a n/a Refresh rate 1.5 seconds 5 6 seconds 2 seconds Data entry required for rso 2 pediatric use No No Yes rso 2 Sensor Cerebral indications Trending, Absolute Trending only Absolute only Somatic indications Yes Yes Yes Wavelengths 4 2 4 Tolerant of ambient light Yes No No Number of light emitters 2 1 1 Number of light paths 4 2 1 2 SpO 2 Sensor SpO 2 accuracy 70-100% ±2 digits n/a n/a SpO 2 low perfusion accuracy 70-100% ±2 digits n/a n/a Pulse rate accuracy 18-300 BPM ±3 digits n/a n/a Pulse rate low perfusion accuracy 40-240 BPM ±3 digits n/a n/a Warranty Comparison Monitor warranty 36 months 12 months 12 months * Requires signal strength detection Requires setup before sensor reading See Instruction for Use (IFU) for more information on product specifications and testing Specifications subject to change without notice. NONIN MEDICAL 13

Nonin Medical: Leaders in Noninvasive Medical Monitoring Nonin Medical is a technology-driven company and a leader in developing high performing, low cost, easy-to-use noninvasive medical monitoring solutions. Nonin took NIRS-based oximetry to a new level of clinical utility when it invented the fingertip pulse oximeter, so the move to provide clinicians with an accurate, versatile, portable regional oximeter was a natural one. Today, Nonin s new SenSmart Universal Oximetry System takes clinical utility and convenience to the n th degree, utilizing the same innovative sensing and signal processing technologies that already give millions of clinicians the confidence that the numbers they see reflect their patients true physiology. Nonin Medical NIRS-based oximetry advancements include: 1990 Introduced world s first portable hand-held pulse oximeter 1995 Introduced world s first fingertip pulse oximeter the Onyx 9500 2004 Introduced world s first pulse oximeter with Bluetooth wireless technology 2009 Introduced EQUANOX regional oximetry system 2011 Introduced industry-leading accuracy* in the EQUANOX Advance adult absolute regional oximetry sensor for cerebral and somatic applications 2011 Released world s first regional oximetry OEM Solution 2012 Introduced Nonin s Dynamic Compensation algorithm which automatically accounts for pediatric brain tissue development variation when measuring oxygen saturation levels 2013 Introduced world s first rso 2 /SpO 2 universal oximetry system For more information, visit sensmart.com. * EQUANOX 8004CA sensor References 1. Tweddell J, Ghanayem N, Hoffman G. Pro: NIRS is standard care for postoperative management. Semin Thoracic Cardiovasc Surg Pediatric Card Surg Annu. 2010; 13(1):44 50. 2. Davie SN, Grocott HP. Impact of Extracranial Contamination on Regional Cerebral Oxygen Saturation: A Comparison of Three Cerebral Oximetry Technologies. Anesthesiology. 2012; 116(4):834 40. 3. Kreeger R, Ramamoorthy C, Nicolson S, et al. Evaluation of a Pediatric Near-Infrared Cerebral Oximeter for Cardiac Disease. The Annals of Thoracic Surgery. 2012; 94:1527-33. 4. Nonin Medical, Inc. Data on file. Nonin Medical, Inc. 13700 1st Avenue North Plymouth, MN 55441-5443 USA Tel: +1.763.553.9968 +1.800.356.8874 Fax: +1.763.577.5521 E-mail: info@nonin.com Nonin Medical B.V. Prins Hendriklaan 26 1075 BD Amsterdam Netherlands Tel: +31 (0)13-79 99 040 Fax: +31 (0)13-79 99 042 E-mail: infointl@nonin.com 2013 Nonin Medical, Inc. All trademarks are the property of Nonin Medical, Inc. unless otherwise noted. INVOS System is a registered trademark of Covidien. FORE-SIGHT is a registered trademark of CAS Medical Systems, Inc. PHILIPS, IntelliBridge and IntelliVue are registered trademarks of Koninklijke Philips Electronics N.V.; Bluetooth and the Bluetooth Logo are registered trademarks of Bluetooth SIG, Inc. sensmart.com nonin.com M-11113