High Throughput Workflow for Global Metabolomic Profiling of Biological Samples with RapidFire online SPE/MS system

Similar documents
Use of RapidFire/MS for Metabolomics. - from untargeted to targeted and Pathway driven analysis. RapidFire/MS. Moritz Wagner Agilent Technologies

Ultrafast Analysis of Benzodiazepines in Urine by the Agilent RapidFire High-Throughput Triple Quadrupole Mass Spectrometry System

LC/MS Method for Comprehensive Analysis of Plasma Lipids

Agilent 6470 Triple Quadrupole LC/MS System and EMR-Lipid. The Combination for Confident Pesticide Quantitation. Christoph Mueller

LC-Based Lipidomics Analysis on QTRAP Instruments

Impact of Chromatography on Lipid Profiling of Liver Tissue Extracts

Sunil Kulkarni Product Specialist Agilent Technologies

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Comprehensive Food Profiling Combining High Resolution LC/MS and GC/MS Analyses

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

MASS SPECTROMETRY BASED METABOLOMICS. Pavel Aronov. ABRF2010 Metabolomics Research Group March 21, 2010

Agilent Solutions for Lipidomics. Greater Insight into

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Challenges in Separation Technologies

Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results

Lipidomic Analysis by UPLC-QTOF MS

Metabolomic and Proteomics Solutions for Integrated Biology. Christine Miller Omics Market Manager ASMS 2015

Improving Coverage of the Plasma Lipidome Using Iterative MS/MS Data Acquisition Combined with Lipid Annotator Software and 6546 LC/Q-TOF

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

The Agilent MassHunter Software. One Software for all Agilent Mass Spec Systems

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

Quantitative Determination of Drugs of Abuse in Human Plasma and Serum by LC/MS/MS Using Agilent Captiva EMR Lipid Cleanup

Quenching and Metabolites Extraction from adherent cell lines and cell supernatant for metabolic profiling

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

In-Solution Digestion for proteomics

Ultra Columns. also available. ordering note

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Ultra Columns HPLC COLUMNS

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS

Investigating Antibiotic Mode of Action Using Targeted Metabolomics with Ion-pairing Reversed-phase LC/Q-TOF

LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

Sample Preparation is Key

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Determination of Unbound Urinary Amino Acids Incorporated with Creatinine Normalization by LC-MS/MS Method with CLAM-2000 Online Sample Pre-treatment

The Development of LC/MS Methods for Determination of Polar Drugs of Abuse in Biological Samples

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

Benefits and Characteristic Applications of High Resolution GC/MS and LC/MS. Frank David RIC and Ghent University

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

The Development of LC/MS Methods for Determination of MDMA (Ecstasy) and Metabolites in Biological Samples

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Modified QuEChERS for HILIC LC/MS/MS Analysis of Nicotine and Its Metabolites in Fish

Analyze Barbiturates in Urine with Agilent 6430 LC/MS/MS and Poroshell 120 EC-C18

Conflict of Interest Statement

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

Supporting Information

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Filtration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products

William Wikoff : UC Davis (Committee chair) Pavel Aronov: Stanford University. John Asara: Harvard University. Vladimir Shulaev: University of Texas

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Dienes Derivatization MaxSpec Kit

Modernizing the Forensic Lab with LC-MS/MS Technology

The Raptor HILIC-Si Column

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

AbsoluteIDQ p180 Kit. Targeted Metabolite Identifi cation and Quantifi cation

Determination of Multi-Residue Tetracyclines and their Metabolites in Milk by High Performance Liquid Chromatography - Tandem Mass Spectrometry

Metabolomics Core Lab School of Medicine University of Utah

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

Ion Exchange and Reversed Phase interactions in selective Bio-SPME extractions of designer drugs

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

Identification of Haemoglobinopathies by LC/MS

Phenomenex roq QuEChERS Kits. Overview. Spinach Facts

QIAsymphony DSP Circulating DNA Kit

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a

John Haselden 1, Gordon Dear 1, Jennifer H. Granger 2, and Robert S. Plumb 2. 1GlaxoSmithKline, Ware, UK; 2 Waters Corporation, Milford, MA, USA

The LC Column Playbook

Target and Non-target Analysis of Metabolites in Urine Using Scan/MRM and GC/MS/MS

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

Application Note. Abstract. Authors. Pharmaceutical

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology

Transcription:

High Throughput Workflow for Global Metabolomic Profiling of Biological Samples with RapidFire online SPE/MS system Michelle Romm, Ph.D. Applications Scientist, Agilent Technologies, Inc. 1

What is High Throughput? # of Samples RapidFire/MS LC/MS N=1 14 secs 30 mins N=100 N=1,000 23 mins 3.8 hrs 120X Faster 50 hrs 20.8 days N=10,000 38.8 hrs (1.6 days) 208.3 days 2

Why High Throughput Profiling? Is Faster better? When Method Development ph Solvents/Additives Chemistry Timings/Flows Large Population Studies N= 5 50 500 5000 Better Experiments! 3

RapidFire/MS System 4

RapidFire 365 Online SPE/MS System BenchBot plate handling robot 63 plate capacity (384 well plates = 24,192 samples) Off-deck reach capability Quaternary pumps Solvent switching capability Capable of running multiple disparate methods in one batch 12 position automated cartridge changer Automated method development Perform multiple injections of a single sample with different SPE cartridges and mobile phases C18, C8, C4, CN, Phenyl, HILIC, Graphitic Carbon Simply run multiple samples overnight and select your ideal conditions the next morning Aspirate Load/Wash Elute Re-equilibrate 600ms 3000ms 8000ms 1000ms For Research Use Only. Not for Use in Diagnostic Procedures. 5

Method Development: Refining the Experiments Cartridge chemistries Ionization mode Loading solvents/times Elution times/solvents One solution doesn t fit everyone, this system allows FLEXIBILITY! 6

Comparison of SPE Chemistries: HILIC vs. C18 SPE/MS for a Single Feature in Urine Sample Female Urine HILIC HILIC C18 C18 For Research Use only. Not for use in diagnostic procedures 7

Comparison of Chemistries: C18 vs. HILIC SPE/MS (+ESI) in Urine 526 metabolites annotated by C18 SPE/MS 270 metabolites annotated by HILIC SPE/MS 49 annotated metabolites common between HILIC and C18 SPE/MS 747 unique metabolites (100% reproducibility; CV<15%) C18 477 49 HILIC 221 Utilize multiple unique chemistries to increase the metabolite coverage 8

Comparison of ESI Mode: a Small Polar Library Red- NEG Blue- POS ~100 pure endogeneous human metabolite standards small organic acids, biogenic amines, nucleotides, amino acids Custom packed HILIC material Data obtained by Jeramie Watrous and Mohit Jain, University of California, San Diego 9

Comparison of Loading Solvents: HILIC Normal Phase Lactic Acid, -ESI Hexane:IPA (90:10) ACN:Water (95:5) Methanol Data obtained by Jeramie Watrous and Mohit Jain, University of California, San Diego 10

Comparison of Loading Times: Polar Analytes Lactic Acid, -ESI 1750ms HILIC 2250ms 3000ms Data obtained by Jeramie Watrous and Mohit Jain, University of California, San Diego 11

Comparison of Elution ph Lactic Acid, -ESI MeOH:IPA (50:50) + 10mM Ammonium Acetate ph 9.0 MeOH:IPA (50:50) + 0.1% Formic Acid Data obtained by Jeramie Watrous and Mohit Jain, University of California, San Diego 12

High Throughput Metabolomics Profiling Workflow High Throughput Acquisition Batch Data Processing Data Analysis Verification/ Confirmation/ Validation High Throughput Quantitation MassHunter Profinder (NEW) Mass Profiler Professional (MPP) Pooled Sample/ Random Samples LC/MS Acquisition FindbyFormula Verify Targets RapidFire 365.d data input Recursive MFE Statistics Database Search Pathway Analysis LC/MS/MS Acquisition Metlin Library/ SimLipid/ MSC Confirm Targets RapidFire 365 ifunnel 6550 Q-TOF Features.cef output Potential Targets Validate with Reference Standard ifunnel 6490 QQQ For Research Use only. Not for use in diagnostic procedures 13

High-throughput Profiling: What is the Workflow? Human urine Human serum lipidome Milk lipidome For Research Use only. Not for use in diagnostic procedures 14

Human Urine Metabolomics Profiling: Sample Prep Human urine, collected and pooled from healthy subjects (males and females), was purchased from Innovative Research Inc. (Novi, MI) Filter 400µL urine through a 0.22µm Ultrafree-MC centrifugal filter units (Millipore) by centrifugation @ 12,000xg for 20min @ 4 C Pipette 50µL of filtered urine (10 replicates) into the Amicon Ultra-0.5mL Centrifugal Filter (3kDa Cut-off Ultracel-3 membrane) from Millipore Dilute with 350µL of Milli-Q quality water containing 0.2% Acetic acid, 1mM Ammonium acetate, and centrifuge @ 12000xg, 4 C for 30min to concentrate The flow-through represents the metabolomics sample Inject 10µL of flow-through for SPE/MS as well as LC/MS/MS analysis Human urine equivalent to 1.25µL was used for the metabolomics profiling studies For Research Use only. Not for use in diagnostic procedures 15

TIC for 10 Human Urine Samples (C18 SPE/MS) For Research Use only. Not for use in diagnostic procedures 16

EIC of a Single Injection of Urine Sample on C18 RapidFire SPE/MS Male Urine +ESI For Research Use only. Not for use in diagnostic procedures 17

EIC Overlay of a Single Feature in Urine on C18 RapidFire SPE/MS EIC (C18, Pos ESI) Male Urine Male Urine For Research Use only. Not for use in diagnostic procedures 18

ProFinder for High Throughput Batch Analysis of Samples 19

Mass Profiler Professional (MPP) Filter by all 10 reps, abundance >2, CV < 15% Cluster Analysis C18-PosESI 20

Annotation of Creatinine in Urine Samples by C18 RapidFire SPE/MS For Research Use only. Not for use in diagnostic procedures 21

Select High Abundant Metabolites in Human Urine Annotated by SPE/MS Compound RF-C18 Male Hippuric acid 5158031 Pirimicarb 3255466 Enprofylline 496924 Lys Asn Asp 420101 3-Hydroxyhippuric acid 410564 Pinacidil 359491 Nadolol 357228 4-(1-Hydroxy-2-(methylamino)ethyl)phenol 299538 Leu Gln Lys 287646 Triciribine 285932 3-Amino-2-naphthoic acid 277964 L-4-Hydroxy-3-methoxy-a-methylphenylalanine 266033 1-Methylxanthine 262927 AFMK 229545 Creatinine 225274 4-Chloroacetophenone 217597 Jasmolone glucoside 209979 Istamycin C1 192524 N-Acryloylglycine 183487 N2,N2-Dimethylguanosine 175089 N(alpha)-t-Butoxycarbonyl-L-leucine 171812 beta-snyderol 135177 2-Methylguanosine 126988 For Research Use only. Not for use in diagnostic procedures 22

Metlin Library Check for Isomers/Isobars 23

LC/MS/MS Confirmation of Hippuric acid CID@10 CID@20 CID@40 RapidFire C18 SPE/MS +ESI Male Urine Hippuric acid MS/MS @ 40 Metlin Spectral Library MFG for MS/MS Spectral Peaks Hippuric acid 24

Glucose Homeostasis Pathway (WP661_45308) 25

Human Serum Lipidomics Profiling: Sample Prep Human serum, collected and pooled from healthy subjects (males and females), was purchased from Innovative Research Inc. (Novi, MI) Filter 400µL serum through a 0.22µm Ultrafree-MC centrifugal filter units (Millipore) by centrifugation @ 12,000xg for 20min @ 4 C Pipette 100µL filtered serum into a Protein LoBind Eppendorf tube Add 700µL ice-cold Methanol:Isopropanol, 1%Acetic Acid, vortex 30sec Equilibrate for 10min at room temp and Centrifuge at ~12000xg, 20min, 4 C The organic supernatant represents the lipidomics sample Inject 10µL for SPE/MS as well as LC/MS/MS analysis Human serum equivalent to 1.25µL was used for the lipidomics studies For Research Use only. Not for use in diagnostic procedures 26

EIC of a Single Injection of Serum Sample on C18 RapidFire SPE/MS Female Serum -ESI 27

Lipidomics Profiling of Human Serum by C18 SPE/MS 169 lipids annotated in +ESI mode 275 lipids annotated in ESI mode 29 annotated lipids common between +ESI and ESI modes -ESI 246 29 +ESI 140 415 unique lipids For Research Use only. Not for use in diagnostic procedures 28

Milk Lipidomics Profiling: Sample Prep Pipette 150µL of milk into a Protein LoBind Eppendorf tube Add 1200mL ice-cold Methanol:Isopropanol 1%Acetic Acid, vortex 30sec Equilibrate for 10min at room temp and Centrifuge at ~12000xg, 10min, 4 C Transfer the organic supernatant into a separate Protein LoBind Eppendorf tube. Store at -80 C Inject 10mL of sample for SPE/MS Milk equivalent to 1 µl was used for the lipidomics studies 29

Smell Whole Milk C4 SPE/MS (+ESI) Time Course 10 8 6 4 2 0 0 5 10 15 Day 30

Whole Milk C4 SPE/MS (+ESI) Days 1 to 7 31

Mass Profiler Professional (MPP) 1056 features (all 9 reps, CV < 15%) 894 features (un-paired t-test, p < 0.05) C4-PosESI Cluster Analysis (534 features) 534 features (Fold-change > 2) 32

Summary Performed high throughput profiling of biological samples with RapidFire SPE/MS RapidFire data were fully integrated and compatible with Agilent software solutions (MassHunter, ProFinder, MPP, Metlin) Demonstrated reproducibility and fidelity of the current high throughput workflow for data processing and analysis Confirmed select metabolites/lipids by MS/MS analysis For Research Use only. Not for use in diagnostic procedures 33

Take Home Message Fast Less than 15 secs per sample Facilitates quick hypothesis verification Flexible Ability to change method parameters quickly Multiple binding chemistries available Reproducible Replicates had less than a CV <15% Extracted peaks were superimposable High fidelity of data Annotations were confirmed by LC/MS/MS 34

Acknowledgements I would like to thank Jeramie Watrous and Mohit Jain from University of California, San Diego. 35