Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Similar documents
Bone Bangalore

1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe

Understanding Hip Implant Options

8.3 Tips and Tricks: Fracture of a Ceramic Insert

Systematic Review of Clinical Outcome using Titanium Fiber Mesh Porous Ingrowth Surfaces

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

Case Report Recurrent Catastrophic Ceramic Femoral Head Failure in Total Hip Arthroplasty

CERAMIC-ON-METAL. References: Cat No: version 2

CeramTec Medical Products. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

Optimum implant geometry

TOTAL HIP REPLACEMENT:

Peggers Super Summaries: THR and Revision Concepts

Featuring. Technology. Product Rationale

Optimizing function Maximizing survivorship Accelerating recovery

Principles of acetabular fixation in primary and revision hip arthroplasty Piotr Wojciechowski, Damian Kusz, Anna WAGNER

Arcos Modular Femoral Revision System

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

BIOTRIBOLOGICAL AND MECHANICAL ANALYSIS OF TOTAL HIP ARTHROPLASTIY FAILURE: How to break the code

Medical Products Division. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX

Session 3: Controversies for Bearing Surfaces in THR

RECOVERY. P r o t r u s i o

Product Information. *smith&nephew POLARCUP Dual Mobility System

Optimum implant geometry

Informed Consent for HRA

The Treatment of Pelvic Discontinuity During Acetabular Revision

G7 ACETABULAR SYSTEM. beautifully. efficient.

The Leader in Orthopaedic Innovation

RM Philosophy Innovation based on clinical evidence.

Ceramic Femoral Heads and Acetabular Cup Liners

Impingement in THA. Georgi I. Wassilew. Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C.

Fracture of an Acetabular Component Inserted without Cement: A Case Report

Case Report Anterior Subluxation after Total Hip Replacement Confirmed by Radiographs: Report of Two Cases

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

What Are Hip and Knee Replacement Implants Made Of?

BIOLOX delta Option Ceramic Femoral Head System. Product Features and Instructions for Use

Optimum implant geometry

National Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement

Stability without compromise. Epsilon Durasul Constrained Insert

Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, OH, US.

TITLE: Metal on Metal Total Hip Replacements or Hip Resurfacing for Adults: A Review of Clinical Effectiveness and Cost Effectiveness

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

ARTICLE IN PRESS. Surface Oxidized Zirconium Total Hip Arthroplasty Head Damage Due to Closed Reduction. Effects on Polyethylene Wear

Revision hip arthroplasty with S-ROM prosthesis: a study of clinical outcomes and implant stability

TaperFit. Cemented Total Hip Replacement Surgical technique

*smith&nephew. BIRMINGHAM HIP Resurfacing (BHR ) System Patient Information Revision 0

BIOLOX delta Option Ceramic Femoral Head System

PINNACLE REVISION CUP SYSTEM

Zimmer Longevity Highly Cross-linked Polyethylene. Clinical Value Dossier - APAC

Move Ahead with Confidence. Hip Replacement Solutions from DePuy Orthopaedics

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

Surface Roughness of Femoral Head Prostheses After Dislocation

Painful Metal-on-Metal Total Hip Arthroplasty

ReCap Product Rationale

Orthopedic Surgery (Adult Hip Service) (Seoul National University Hospital)

Repeated Ceramic Head Fracture after Ceramic-on-ceramic Total Hip Arthroplasty

CASE 56 Hip Pain. ? Diagnosis

Dual Mobility Cups. Kris Govaers, MD, PhD Dendermonde Belgium

Clinical and radiological results of the stemmed Mc Minn cup in hip revision surgery

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Document No Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE

CAUTION Federal law (USA) restricts this device to sale, by or on the order of a physician.

28 Surgical Technique

Bi-Polar 22.2mm & 28mm System - Operative technique

Technique Guide Hip Resurfacing System

The information contained in this document is intended for healthcare professionals only.

- October 2013 English

Duraloc CONSTRAINED LINER

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Trabecular Metal Acetabular Revision System Buttress and Shim Augments Surgical Technique

Management Of Acetabular Deficiency In Total Hip Arthroplasty: A Series Of 15 Cases

ACETABULAR CUP SURGICAL TECHNIQUE

FDA Safety Communication: Metal-on- Metal Hip Implants

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

POLARCUP Dual Mobility System. General Safety Instructions. Instructions for Use. Duty to inform the patient. Implant passport

DIRECT ANTERIOR APPROACH

Case Report Inflammatory Pseudotumor Complicated by Recurrent Dislocations after Revision Total Hip Arthroplasty

Effect of Component Design in Retrieved Bipolar Hip Hemiarthroplasty Systems

Revision Total Hip Arthroplasty Using Tantalum Augment in Patients with Paprosky III or IV Acetabular Bone Defects: A Minimum 2-year Follow Up Study

*smith&nephew POLARCUP Dual Mobility System. Product Information

Tri-Lock Bone Preservation Stem

Formosan Journal of Musculoskeletal Disorders

R3think your options. For US distribution only.

Metal-on-metal articulations generate approximately to particles PSEUDOTUMORS FACTORS PATHOGENESIS

Comparative Study of Peripheral Rim Fixation Using Jumbo Cup in Revisional Hip Arthroplasty

The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series

Prevention of dislocation after hip replacement in elderly patients. Piotr WOJCIECHOWSKI, Damian KUSZ, Mariusz NOWAK, Konrad KOPEĆ

Cementless Acetabular Fixation With and Without Screws

WHAT IS THE BEST BONE FIXATION TYPE? 2/11/2011

Manza Cup HA SURGICAL TECHNIQUE.

Presented by : Frank Filice (PT) London Health Sciences Centre

R3 delta Ceramic Acetabular System PATIENT INFORMATION. Table of Contents

Revision Total Hip Replacement

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

Lesson Learned From Retrieval Analysis Of A Dislocating, Large Diameter MoM Revision THA A Case Report

Hip Resurfacing vs. Standard Total Hip Replacement

Hip Resurfacing System

The Spatial Location of Impingement in Total Hip Arthroplasty

Transcription:

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Diagnosis: Ceramic head fracture In the 1970 s, Boutin implemented ceramic in modern total hip arthroplasty (THA). Although initial fracture rates of 13.4 % for ceramic heads were described before the 1990 s, the inferior rate of wear and friction when compared to metallic heads, and optimized tribology was very promising in THA. Gradual improvements in processing of the ceramic material led to a significant reduction of the fracture rate to below 0.1 % [Willman]. Thus, alumina ceramic heads have currently become the standard material in THA with ceramic bearing surfaces. Nevertheless, multiple case reports have been published and the causes of fractures are diverse and vary from traumatic events, to impingement between the neck and the liner rim. Spontaneous fractures without any history of trauma have also been described [Holmer] The advantages of all-alumina bearings are superb wear resistance, stability, and inertness demonstrated over 3 decades. The disadvantage is a small risk for brittle fracture, as described in this paper. Surveying the latest ceramic hip series reported in recent journal articles or presented at the 6th World Biomaterials Congress, there were 11 studies representing more than 35,000 cases followed for 3 to 25 years. There were 24 reported fractures. A unique survey of hip complications in the 1990s found a

fracture risk of approximately 1.4 per 1000 ceramic balls used in the United States. A company database holding more than 2.5 million records described the overall fracture risk as 1 per 10,000 cases. Initial use of ceramic cup inserts indicated a 2% to 3% incidence of chipping during surgery. Beginning in 1997, the number of ceramic-metal cup-locking cases entered into a US Food and Drug Administration ceramics database was more than 2400, with no fractures reported by the FDA in July 2003.[ Clarke Am J Orthop (Belle Mead NJ). 2008 Feb;37(2):E26] In this report, we present a 46-year old patient who underwent primary THA and was a victim of low-energy trauma [fall in the shower] four years later. Initial radiographs showed nonconcentric relation of the neck of the femoral stem to metal liner and the ceramic fragment appeared to have been overriding the superior part of the neck. Operation Operation: Posterior approach

Required extensive debridement of all synovial tissue Extensive lavage Convert to plastic on metal head; Or newer ceramic on ceramic Revision surgery [Hwang] Evaluation and investigation in a patient with ceramic implants presenting with sudden onset groin pain or hip injury. Early diagnosis is important. Look for asymmetry of the femoral head component is one early radiological sign which may indicate failure. Early cases: As a new cup could have been cemented into the acetabular shell. There may also have been limited damage to the stem taper at that stage, allowing replacement of the failed ceramic head with a metal one without the need for stem revision. Late cases Erosion of the stem taper through both the polyethylene insert and its metal shell meant that a simple exchange of the polyethylene insert was not an option. It also made intraoperative dislocation of the hip and subsequent retrieval of the acetabular component more difficult. The stem taper had eroded into pelvic bone, and its subsequent movement created a small defect superiorly. During its migration through the acetabulum, the femoral stem taper had become damaged and eroded, necessitating revision of the whole femoral component as opposed to replacement of the modular head alone. Furthermore, bone ingrowth around the acetabular shell metal acetabular component complicated its removal, resulting in a much larger pelvic defect, which required bone grafting and use of a GAP ring implant. Removal of uncemented acetabular components often results in large pelvic defects, as in this case, due to osteointegration of bone at its interface with the implant. Specialized techniques have now been developed, which reduce the amount of bone loss at the bone implant interface. These include use of the Explant device (Zimmer, Warsaw, Ind), which uses short followed by long blades to break the bone implant interface with minimal resection of surrounding bone.

Revision total hip arthroplasty after fracture of a ceramic femoral head is a challenging procedure. Retrieval of all ceramic particles is crucial to the survivorship of the revision, as any retained fragments may cause subsequent abrasive wear and lead to osteolysis and loosening. A study looking at the outcome of revision procedures following ceramic femoral head fracture gave a survival rate of 63% at 5 years [Kempe]. The most frequent cause of failure necessitating rerevision was implant loosening. Factors identified as contributing to longer survival rates included exchange of any components, which may contain embedded ceramic particles, and extensive synovectomy, to remove as much ceramic debris as possible. DISCUSSION The cracking sound incident after trauma, as described by the patient, was probably due to the complete fracture of the ceramic head. It is not uncommon to misdiagnose this fracture unless a careful assessment performed on the initial X ray. When diagnosis is missed and management is delayed, a major destruction of the ceramic head and extensive synovitis with metallosis could cause failure of implant fixation [Aghaie]. This raises the question of the need of a possible guideline or recommendation for patients suffering acute trauma of the lower limb with a total hip arthroplasty, especially those with ceramic bearing surfaces. The patient s ability to walk without any pain originating from the hip does not rule out fracture of humeral head and a careful radiological assessment is essential. It presents a challenge for the assisting physician to obtain a correct diagnosis. It has been suggest a close follow-up including repeat conventional radiographs several weeks after trauma. It is required to increase awareness among physicians and training staff who treat trauma patients who underwent previous ceramic total joint replacements, in order to pedite

the diagnosis of possible posttraumatic implant failures. The most common cause of long-term failure of total hip arthroplasty is osteolysis and aseptic loosening secondary to wear debris. Combinations of hard materials such as ceramic-on-ceramic generate smaller volumes of particulate wear debris than traditional combinations such as metal-on-polyethylene. Periarticular tissue in both cases contained titanium wear debris due to impingement of the neck of the titanium femoral component against the rim of the titanium shell and ceramic debris from edge loading wear (stripe wear) of the ceramic. It is not clear whether the titanium debris, the ceramic debris, or both caused the osteolysis. These cases illustrate that the risk of osteolysis persists, even with third-generation alumina ceramics [Bonar]. References 1.Willmann G. Ceramic femoral head retrieval data. Clin Orthop Relat Res 2000; 379: 22-8. 2. Holmer J Arthroplasty 1993; 8(6): 567-71. 3. Clarke Am J Orthop (Belle Mead NJ). 2008 Feb;37(2):E26 4. Aghaie, The Open Orthopaedics Journal, 2012, 6, 362-365 5. Bonar. J Arthroplasty. 2008 Dec;23(8):1240.e13-9. 6. Hwang. The Journal of Arthroplasty, Volume 22, Issue 3, April 2007, Pages 468-471 7.Kempf Arch Orthop Trauma Surg 1990;109:284.