Usefulness of a Guiding Sheath for Fluoroscopic Colorectal Stent Placement

Similar documents
Afferent Loop Syndrome: Treatment by Means of the Placement of Dual Stents

Newly Designed Sheaths for Gastroduodenal Intervention: An Experimental Study in a Phantom and Dogs

The Role of Colonic Stents in Obstructive Metastatic Colorectal Cancers

The Efficacy of Metallic Stent Placement in the Treatment of Colorectal Obstruction

Stent Collapse as a Delayed Complication of Placement of a Covered Gastroduodenal Stent

Balloon Sheaths for Gastrointestinal Guidance and Access: A Preliminary Phantom Study

Colonic Metal Stents MAKING A DIFFERENCE TO HEALTH

Jung-Hoon Park 1 Ho-Young Song 1 Jin Hyoung Kim 1 Deok Ho Nam 2 Jae-Ik Bae 3 Min-Hee Ryu 4 Hwoon-Yong Jung 4

EGIS BILIARY STENT. 1. Features & Benefits 2. Ordering information 3. References

Gastric / EUS Metal Stents

Successful Self-Expandable Metallic Stent Placement for a Case of Distal Rectal Stenosis due to Gastric Cancer Metastasis

Fluoroscopically Guided Placement of Self-Expandable Metallic Stents and Stent-Grafts in the Treatment of Acute Malignant Colorectal Obstruction

Clinical application of self-expanding metallic stent in the management of acute left-sided colorectal malignant obstruction

A Novel Method of Punctured Miller-Abbott Tube Placement Using a Guidewire Under Fluoroscopic Guidance

Tumor Overgrowth After Expandable Metallic Stent Placement: Experience in 583 Patients With Malignant Gastroduodenal Obstruction

Early Symptomatic Strictures after Gastric Surgery: Palliation with Balloon Dilation and Stent Placement

Fluoroscopy-Guided Endoscopic Removal of Foreign Bodies

Effectiveness and safety of metallic stent for ileocecal obstructive colon cancer: a report of 4 cases

Fluoroscopically Guided Balloon Dilation for Benign Anastomotic Stricture in the Upper Gastrointestinal Tract

Biliary Metal Stents MAKING A DIFFERENCE TO HEALTH

Safety And Efficacy of Stenting In Large Bowel Obstruction - A Review Of Clinical Practice

Стенты «Ella-cs» Уважаемые коллеги! Высылаем очередной выпуск «Issue of ELLA Abstracts»

Colorectal stenting. Alessandro Repici, MD Digestive Endoscopy Unit IRCCS Istituto Clinico Humanitas Milano, Italy

Colonic stenting anno 2014

The first stents designed for use in the biliary tree and

Expandable stents in digestive pathology present use in an emergency hospital

EGIS ESOPHAGEAL STENT. 1. Features & Benefits 2. Ordering information 3. References & Clinical case

Incidence and Multiplicities of Adenomatous Polyps in TNM Stage I Colorectal Cancer in Korea

The CREST Trial. Funded by Cancer Research UK and developed by the National Cancer Research Institute

SMJ Singapore Medical Journal

Correspondence should be addressed to Roberto Di Mitri;

Airway stent placement for malignant tracheobronchial strictures in patients with an endotracheal tube

The Value of Urgent Barium Enema and Computed Tomography in Acute Malignant Colonic Obstruction: Is Urgent Barium Enema Still Necessary?

폐쇄성대장암의수술전처치로써내시경적자가팽창스텐트삽입술의종양학적안정성

Colonic stenting: everything that a resident needs to know

Clinical Study Clinical Outcomes of Colonic Stent in a Tertiary Care Center

Palliative Treatment of Malignant Esophagopulmonary Fistulas With Covered Expandable Metallic Stents

A tale of two LAMS: a report of benign tissue ingrowth resulting in recurrent gastric outlet obstruction

Colorectal Stents: Current Status

A new variable stivness colonoscope makes colonoscopy easier: a randomised controlled trial

Endoscopic pancreatic necrosectomy in 2017

Regression of Advanced Gastric MALT Lymphoma after the Eradication of Helicobacter pylori

Case Report Thoracic Imaging. Eun Kyung Khil, MD 1, Heon Lee, MD, PhD 1, Keun Her, MD 2 INTRODUCTION CASE REPORT

CEA (CARCINOEMBRYONIC ANTIGEN)

OBJECTIVE. The purpose of this article is to compare the clinical effectiveness and complications. the treatment of benign urethral strictures.

UNDERSTANDING X-RAYS: ABDOMINAL IMAGING THE ABDOMEN

The focus of Chapter 9 is on anoscopy, proctosigmoidoscopy, flexible sigmoidoscopy, and colonoscopy procedures and all

IryPump S Rectal User Guide SWITCH ON TO IRRIGATION RECTAL IRRIGATION

DIAGMED HEALTHCARE. Disposable Injection Needles

Esophageal Dilatation (Bouginage)

Endoscopic stent placement throughout the gastrointestinal tract van den Berg, M.W.

Tracheal Stricture and Fistula: Management With a Barbed Silicone-Covered Retrievable Expandable Nitinol Stent

The Medline search yielded 43 hits, while the search in the CDSR yielded no additional Cochrane reviews.

Yong Fan 1,2 Ho-Young Song 1 Jin Hyoung Kim 1 Jung-Hoon Park 1 Jinoo Kim 1 Hwoon-Yong Jung 3 Sung-Bae Kim 3 Heuiran Lee 4

Carcinoembryonic Antigen

Early Infectious Complications of Percutaneous Metallic Stent Insertion for Malignant Biliary Obstruction

Covered stenting in patients with lifting of gastric and high esophago-tracheal fistula

Ulcerative Colitis. ulcerative colitis usually only affects the colon.

Owen Dickinson. Consultant in Endoscopy & Interventional Radiology. Upper GI Stenting. Rotherham Foundation Trust

Hirschsprung Disease and Contrast Enema: Diagnostic Value of Simplified Contrast Enema and Twenty-Four-Hour-Delayed Abdominal Radiographs

Radiographic Procedures III (RAD 228)

Versatility and Proven Safety

Placement of self-expanding metal stents is a safe and effective palliative

Endoscopic Treatment of Luminal Perforations and Leaks

Jun Yong Jeong 1,2 Joon Koo Han Ah Young Kim Kyoung Ho Lee Jae Young Lee Joon-Won Kang Tae Jung Kim Shang Hoon Shin Byung Ihn Choi

MICRO-TECH Europe. MICRO-TECH Colon and rectum stents. Colon and rectum stents

Hirschprung s. Meconium plug R/S >1 R/S <1

Correspondence should be addressed to Justin Cochrane;

Tissue Acquisition. Introducing our large range of single use accessories for the collection of histology and cytology in the GI tract.

-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE

Jennifer Hsieh 1, Amar Thosani 1, Matthew Grunwald 2, Satish Nagula 1, Juan Carlos Bucobo 1, Jonathan M. Buscaglia 1. Introduction

Catheters and Wires. Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon

creating stability a bess group company Stents for Gastroenterology

Tumor Localization for Laparoscopic Colorectal Surgery

Supplementary Appendix

LONG TERM OUTCOME OF ELECTIVE SURGERY

DIGESTIVE SYSTEM SURGICAL PROCEDURES December 22, 2015 (effective March 1, 2016) INTESTINES (EXCEPT RECTUM) Asst Surg Anae

Repeat Single Incision Laparoscopic Surgery after Primary Single Incision Laparoscopic Surgery for Colorectal Disease

Double-Stent System with Long Duodenal Extension for Palliative Treatment of Malignant Extrahepatic Biliary Obstructions: A Prospective Study

WallFlex Stents Technique Spotlights

3D-printed phantom study for investigating stent abutment during gastroduodenal stent placement for gastric outlet obstruction

Colon Cancer Detection by Rendezvous Colonoscopy : Successful Removal of Stuck Colon Capsule by Conventional Colonoscopy

Stenting of the Cystic Duct in Benign Disease: A Definitive Treatment for the Elderly and Unwell

Should the MUHC approve the use of colorectal stents?

ABSTRACT INTRODUCTION

Postoperative pneumoperitoneum: guilty or not guilty?

Metallic Stent Placement for the Management of Tracheal Carina Strictures and Fistulas: Technical and Clinical Outcomes

Table S2 Study group sample sizes for CEA, CYFRA21-1 and CA125 determinations.

Role of Malabsorptive Endoscopic Procedures in Obesity Treatment

MIC-KEY * Introducer Kits THE EFFICIENT CLINICAL SOLUTION FOR ENTERAL FEEDING

Lumen-apposing covered self-expanding metal stent for management of benign gastrointestinal strictures

This is the portion of the intestine which lies between the small intestine and the outlet (Anus).

Information Technology Solutions

Preview from Notesale.co.uk Page 1 of 34

Association between Sacral Slanting and Adjacent Structures in Patients with Adolescent Idiopathic Scoliosis

Malignant Esophageal Tracheobronchial Strictures: Parallel Placement of Covered Retrievable Expandable Nitinol Stents

Billing Guideline. Subject: Colorectal Cancer Screening Exams (Invasive Procedures) Effective Date: 1/1/14 Last revision effective 4/16

Fig. 1. Ileal and jejunal metastases from adenocarcinoma of the lung in 62-year-old male with a clinical history of bloody stool. A.

WallFlex Biliary RX Partially Covered Stent System Prescriptive Information

Feasibility of Emergency Laparoscopic Reoperations for Complications after Laparoscopic Surgery for Colorectal Cancer

Transcription:

Original Article http://dx.doi.org/10.3348/kjr.2012.13.s1.s83 pissn 1229-6929 eissn 2005-8330 Korean J Radiol 2012;13(S1):S83-S88 Usefulness of a Guiding Sheath for Fluoroscopic Colorectal Stent Placement Ho-Young Song, MD 1, Deok Ho Nam, MD 2, Heuiran Lee, PhD 3 1 Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 138-736, Korea; 2 Department of Radiology, Kyung Hee University Hospital at Gangdong, School of Medicine, Kyung Hee University, Seoul 134-727, Korea; 3 Department of Microbiology, Bio-Medical Institute of Technology, University of Ulsan College of Medicine, Seoul 138-736, Korea Objective: To investigate the technical feasibility, clinical usefulness, and safety of a guiding sheath in fluoroscopic stent placement for patients with malignant colorectal obstructions. Materials and Methods: Between June 2007 and January 2011, fluoroscopic placement of a dual colorectal stent was attempted in a total of 97 patients with malignant colorectal obstructions. A polytetrafluoroethylene guiding sheath was used in patients in whom a stent delivery system failed to reach the obstruction. Usefulness of the sheath was evaluated depending on whether the sheath could successfully assist the stent delivery system reach its area of interest. Results: The guiding sheath was needed in 22 patients (15 men, 7 women; age range, 33-77 years; mean age, 59 years). The overall success rate for passing the sheath to the area of interest was 100%. There were no procedure-related deaths or major complications. The majority of the patients reported mild discomfort. In 2 of 22 patients with successful passing of the sheath to the area of interest, stent placement failed because of failure in the negotiation of a guide wire through the obstruction. Conclusion: Using a guiding sheath seems to be easy, safe and useful in fluoroscopic stent placement for patients with malignant colorectal obstructions. Index terms: Colon; Interventional procedure; Stenosis or obstructions; Stents and prostheses Received November 5, 2011; accepted after revision December 2, 2011. This study was supported by a grant of the Korean Health Technology R&D Project, Ministry for Health, Welfare & Family Affairs, Republic of Korea (A101819). Corresponding author: Ho-Young Song, MD, Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 138-736, Korea. Tel: (822) 3010-4370 Fax: (822) 476-0090 E-mail: hysong@amc.seoul.kr This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. INTRODUCTION Recently, fluoroscopic or endoscopic placement of expandable metallic stents has been increasingly used as a safe preoperative or palliative treatment of malignant colorectal obstructions (1-5). In colorectal stent placement, however, passage of a guide wire and stent delivery system through an area of obstruction poses a major challenge. The presence of a tortuous or redundant sigmoid colon or a splenic or hepatic flexure of the transverse colon poses difficulties in passage of the stent delivery system to the obstruction site as a result of multiple loop formations in the tortuous or redundant portion, which leads to loss S83

Song et al. of forward movement secondary to buckling of the stent delivery system on its way to the area of obstruction (6, 7). To overcome the problem, we developed a guiding sheath that we used in selected patients in whom passage of a stent delivery system to the obstruction failed during fluoroscopic stent placement in patients with malignant colorectal obstructions. The aim of this study was to prospectively investigate the technical feasibility, clinical usefulness, and safety of a guiding sheath in fluoroscopic stent placement for patients with malignant colorectal obstructions. MATERIALS AND METHODS Patients Informed consent for placement of an expandable metallic stent with use of a guiding sheath was obtained for each patient, and our institutional review board approved this prospective study. Between June 2007 and January 2011, fluoroscopic placement of a dual colorectal stent (S&G Biotech, Seongnam, Korea) was performed in a total of 97 consecutive patients with malignant colorectal Table 1. Characteristics of 97 Patients in Study Population No. % Patients 97 100 Mean age (year, range) 59 (22-88) Sex (male, female ratio) 59 : 38 61 : 39 Stricture length (cm, range) 5.8 (2-15) < 5 cm 33 34 5 cm to < 10 cm 52 54 10 cm to < 15 cm 12 12 Location of obstruction Ascending colon 3 3 Transverse colon 21 22 Descending colon 9 9 Sigmoid colon or rectum 64 66 Source of malignancy Colon cancer 70 72 Stomach cancer 17 18 Pancreatic cancer 6 6 Ovarian cancer 2 2 Cholangiocarcinoma 2 2 Indication Palliation 64 66 Pre operation 33 34 obstructions (Table 1). The sites of obstruction were at the ascending colon in 3 patients, at the transverse colon in 21 patients, at the descending colon in 9 patients, and at the sigmoid colon or rectum in 64 patients. Inclusion criteria for dual stent placement were as follows: 1) documented malignancy; 2) colorectal obstruction as defined by symptoms that resulted in defecation difficulty. Exclusion criteria were 1) nonsymptomatic patients with malignant colorectal obstruction, 2) clinical evidence of perforation or peritonitis combined with multiple small bowel obstructions, 3) extension of rectal cancer to the anal sphincter. The guiding sheath was used in patients in whom passing a stent delivery system to the area of interest failed under fluoroscopic guidance because of buckling of the stent delivery system in a tortuous or redundant portion of the colon. Guiding Sheath Construction The guiding sheath was made of a straight polytetrafluoroethylene tube (Sang-A Flontec Co. LTD., Incheon, Korea). The tube was 5.5 and 6.8 mm in its inner and outer diameters, respectively. The distal part of the sheath was bent using a heat-gun, thus creating J-shaped curved tips. A tungsten wire was attached to the distal tip of the sheaths for radio-opacity with 12% polyurethane covering for surface smoothness. The distal 3 cm section of the sheath was positioned at an angle approximately 80 degrees to the axis (Fig. 1). The sheaths for obstructions from the rectum to the descending colon, from the splenic A B C Fig. 1. Photographs of guiding sheath and stent delivery system. Photograph shows guiding sheath (A), distal end (B) of stent delivery system (arrows) loaded in sheath (curved arrows), and proximal end (C) of stent delivery system (arrows) loaded in sheath (curved arrows). S84

Guiding Sheath for Fluoroscopic Colorectal Stent Placement flexure to the middle portion of the transverse colon, and from the middle portion of the transverse colon to the cecum were 90 cm, 120 cm, and 150 cm long, respectively. Techniques for Stent Placement and Usage of the Guiding Sheath The dual stent with its placement technique has previously been described in detail (5, 8, 9). Briefly, the dual stent (S&G Biotech, Seongnam, Korea) consisted of an outer stent and an inner bare nitinol stent. The stent introducer system (S&G Biotech) consisted of a Teflon sheath 4.5 mm in outer diameter, a pusher coil catheter, and a guiding olive tip. The outer and inner stents were loaded in their own Teflon sheaths. Drugs for anesthesia or sedation were not used. With the patient in the left lateral decubitus position, a stiff-angled, 260-cm-long, 0.035-inch exchange guide wire (Radifocus M; Terumo, Tokyo, Japan) was inserted under fluoroscopic guidance through the anus across the obstruction with the help of a sizing coil catheter (S&G Biotech). The exchange guide wire was replaced with a super-stiff 260-cm-long guide wire (Medi-tech/Boston Scientific, Watertown, MA, USA), and the sizing coil catheter was removed with the super-stiff guide wire left in place. Under fluoroscopic guidance, a stent delivery system loading the outer stent was passed over the super-stiff guide wire through the A B C D E Fig. 2. Radiographs obtained before and during stent placement in patient with recurrent gastric cancer involving middle portion of transverse colon. A. Barium study before stent placement shows near complete obstruction (arrow). B. Radiograph obtained during negotiation of coil catheter (arrowheads) with guide wire (arrow) shows tortuous sigmoid colon (curved arrows). C. Straightening of sigmoid colon using guiding sheath with stiff guide wire (arrows). D. Radiograph obtained just prior to passage of stent delivery system for coaxial placement of inner bare stent into outer stent (arrowheads). Note radiopaque tip (arrow) of sheath located in descending colon. E. Water soluble contrast media study immediately after placement of stent shows good flow of contrast medium through stent (arrowheads). Note radiopaque tip (arrow) of sheath located in descending colon. S85

Song et al. obstruction. After placement of the outer stent, the stent delivery system was removed with the super-stiff J-tip guide wire left in place. A stent delivery system loading the inner bare stent was then advanced over the guide wire to place the inner bare stent coaxially into the outer stent. The guiding sheath was used for cases where a stent delivery system failed to reach the site of obstruction due to a tortuous or redundant sigmoid colon or a hepatic or splenic flexure of the transverse colon. The stent delivery system was introduced into the sheath until its tip passed through the sheath. The sheath loading the stent delivery system was then passed over the guide wire until the tip of the sheath passed through the redundant colonic portion (Fig. 2). Analysis of Results We determined the success rate of passing the sheath to the area of interest, assessed the patient s tolerance of the procedure, and recorded complications associated with the procedure. The success of sheath passing was defined as successful passage of the sheath through the redundant sigmoid colon or hepatic or splenic flexure of the transverse colon to the area of interest under fluoroscopic guidance. We used Fisher s exact test to determine the number of patients who needed a guiding sheath varied according to the site of the lesion. RESULTS The guiding sheath was needed in 22 of 97 patients (15 men, 7 women; age range, 33-77 years; mean age, 59 years). The obstruction was complete in 5 patients and incomplete in the remaining 17 patients. As for the site of colonic obstruction, all three patients (100%) with obstruction at the ascending colon, 12 of 21 patients (57%) with obstruction at the transverse colon, 4 of 9 patients Table 2. Usage of Sheath with regard to Location of Obstruction Location of Obstruction No. of Patients *No. of Sheaths (%) P-value Ascending colon 3 3 (100%) Transverse colon 21 12 (57%) Descending colon 9 4 (44%) Sigmoid colon or rectum 64 3 (5%) Total number 97 22 Note. *No. of patients who needed sheath. < 0.001 (44%) with obstruction at the descending colon, and 3 of 64 patients (3%) with obstruction at the sigmoid colon or rectum required use of the sheath (Table 2). The number of patients who needed the sheath was significantly different between the sites of obstructions (p < 0.001). Underlying causes of etiology include cholangiocarcinoma (n = 1) and colon (n = 9), gastric (n = 8), and pancreatic (n = 4) cancers. The average length of the stricture was 64 mm (range, 42 mm to 140 mm). The overall success rate for passing the sheath to the area of interest was 100%. There were no procedure-related deaths or major complications. The majority of the patients reported mild discomfort during insertion of the sheath to the area of interest. In 2 of 22 patients with successful passing of the sheath to the area of interest, stent placement failed because of failure in the negotiation of a guide wire through the obstruction. DISCUSSION Technical difficulties in colorectal stent placement are generally more frequent with proximal obstructions than with distal ones, which accounts for the fact that there are fewer reports of right-sided colonic stent placement (10-12). In cases with a redundant sigmoid colon or a splenic or hepatic flexure of the transverse colon, advancement of a stent delivery system to the obstruction is difficult due to the colonic redundancy and tortuosity (6, 7). In these situations, stabilization of the stent delivery system can be achieved using an endoscope (13). Stent delivery systems for covered stents, however, are too large to be placed through the working channel of the therapeutic endoscope (5, 9, 14). In our study, the sheath proved instrumental in providing the necessary support for successful passage of the stent delivery systems through the tortuous or redundant portion of the colon to the obstruction under fluoroscopic guidance. The sheath as a stiffening device was needed in 22 of 97 patients (22.7%), and the overall success rate for passing the sheath through the tortuous or redundant sigmoid colon or the hepatic or splenic flexures of the transverse colon to the area of interest was 100%. With regard to dual stent placement, a stent delivery system loading the outer stent should be first passed over the guide wire through the obstruction. After placement of the outer stent, its stent delivery system should be removed with the guide wire left in place. A stent delivery system loading the inner bare stent is then advanced over S86

Guiding Sheath for Fluoroscopic Colorectal Stent Placement the guide wire to place the inner bare stent coaxially into the outer stent. The sizing coil catheter is also used twice for measurement of the obstruction length prior to stent placement and during the water soluble contrast media study immediately after stent placement. Multiple passages of the stent delivery system and the sizing coil catheter over the guide wire through the obstruction can be difficult and time-consuming, particularly in patients with redundant sigmoid colon or flexures of the transverse colon. We found that the sheath in such cases was useful in replacing the stent delivery system and the coil catheter due to the simplicity and ease of use of the replacement technique. Sebastian et al. (15) carried out a systematic review of 54 publications on colorectal stent placement published between January 1990 and May 2003. The 54 publications included a total of 1198 patients with malignant obstructions. The stent was placed under endoscopic guidance in 1%, combined endoscopic and fluoroscopic guidance in 69%, and under fluoroscopic guidance in 30%. The overall technical success rates in individual series varied from 64% to 100% (median 94%). The technical failure rates were 5.8% at the rectosigmoid area, 14.5% at the descending colon, and 15.4% at the transverse and ascending colon. Baron et al. (13, 16) concluded that stents may be safely placed into the right colon using endoscopic techniques and that stent placement under fluoroscopic guidance should be limited to the left colon; whereas, Mainar et al. (1) argued that the endoscopic approach is associated with greater patient discomfort and risks for complications. In our experience, straightening of the redundant colon and stabilization of the stent delivery system were achieved using the guiding sheath. We believe that fluoroscopic stent placement can be applied to the left colon obstruction given the superior patient tolerability of the fluoroscopic technique with its use of a delivery system with a small bore. With regard to the site of colonic obstruction, we found that more proximal lesions were associated with a greater need for the sheath (Table 1). For example, all three patients (100%) with obstruction at the ascending colon, 57% of the patients (n = 21) with obstruction at the transverse colon, 44% of the patients (n = 9) with obstruction at the descending colon, and 3% of the patients (n = 64) with obstruction at the sigmoid colon or rectum required use of the sheath. The sheath appears to substantially facilitate fluoroscopic placement in the right colon, and its use warrants further investigation. In conclusion, using the guiding sheath seems to be easy, safe and useful in fluoroscopic stent placement for patients with malignant colorectal obstructions. REFERENCES 1. Mainar A, De Gregorio Ariza MA, Tejero E, Tobío R, Alfonso E, Pinto I, et al. Acute colorectal obstruction: treatment with self-expandable metallic stents before scheduled surgery-- results of a multicenter study. Radiology 1999;210:65-69 2. Camúñez F, Echenagusia A, Simó G, Turégano F, Vázquez J, Barreiro-Meiro I. Malignant colorectal obstruction treated by means of self-expanding metallic stents: effectiveness before surgery and in palliation. Radiology 2000;216:492-497 3. Baron TH. Expandable metal stents for the treatment of cancerous obstruction of the gastrointestinal tract. N Engl J Med 2001;344:1681-1687 4. Khot UP, Lang AW, Murali K, Parker MC. Systematic review of the efficacy and safety of colorectal stents. Br J Surg 2002;89:1096-1102 5. Song HY, Kim JH, Shin JH, Kim HC, Yu CS, Kim JC, et al. A dual-design expandable colorectal stent for malignant colorectal obstruction: results of a multicenter study. Endoscopy 2007;39:448-454 6. Aviv RI, Shyamalan G, Watkinson A, Tibballs J, Ogunbaye G. Radiological palliation of malignant colonic obstruction. Clin Radiol 2002;57:347-351 7. Mosca S. How can we improve the implementation of new endoscopic techniques? Concerning colonic stenting. Endoscopy 2003;35:709-710; author reply 711-712 8. Song HY, Kim JH, Kim KR, Shin JH, Kim HC, Yu CS, et al. Malignant rectal obstruction within 5 cm of the anal verge: is there a role for expandable metallic stent placement? Gastrointest Endosc 2008;68:713-720 9. Kim JH, Song HY, Li YD, Shin JH, Park JH, Yu CS, et al. Dualdesign expandable colorectal stent for malignant colorectal obstruction: comparison of flared ends and bent ends. AJR Am J Roentgenol 2009;193:248-254 10. Keymling M. Colorectal stenting. Endoscopy 2003;35:234-238 11. Syn WK, Patel M, Ahmed MM. Metallic stents in large bowel obstruction: experience in a District General Hospital. Colorectal Dis 2005;7:22-26 12. Carne PW, Frye JN, Robertson GM, Frizelle FA. Stents or open operation for palliation of colorectal cancer: a retrospective, cohort study of perioperative outcome and long-term survival. Dis Colon Rectum 2004;47:1455-1461 13. Baron TH, Kozarek RA. Endoscopic stenting of colonic tumours. Best Pract Res Clin Gastroenterol 2004;18:209-229 14. Xinopoulos D, Dimitroulopoulos D, Theodosopoulos T, Tsamakidis K, Bitsakou G, Plataniotis G, et al. Stenting or stoma creation for patients with inoperable malignant colonic obstructions? Results of a study and cost-effectiveness analysis. Surg Endosc 2004;18:421-426 15. Sebastian S, Johnston S, Geoghegan T, Torreggiani W, Buckley S87

Song et al. M. Pooled analysis of the efficacy and safety of self-expanding metal stenting in malignant colorectal obstruction. Am J Gastroenterol 2004;99:2051-2057 16. Baron TH, Rey JF, Spinelli P. Expandable metal stent placement for malignant colorectal obstruction. Endoscopy 2002;34:823-830 S88