Innovation by design. Technology that sets a new standard

Similar documents
RECOMMENDED INSTRUCTIONS FOR USE

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

PTCA Dilatation Catheter. Instructions for Use

PTCA Dilatation Catheter. Instructions for Use

Excimer Laser for Coronary Intervention: Case Study RADIAL APPROACH: CORONARY LASER ATHERECTOMY FOR CTO OF THE LAD FOLLOWED BY PTCA NO STENTING

Advanced Innovation for Exceptional Performance

DURABLE. CONSISTENT. SAFE. IN.PACT Admiral Drug-Coated Balloon

Assurant Cobalt Iliac BALLOON EXPANDABLE STENT SYSTEM

Peripheral Intravascular Lithotripsy (IVL) Catheter Instructions for Use (IFU)

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service

PTA Balloon Dilatation Catheter

1 Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis. N Engl J Med 352;13, March 31, 2005

PTA Balloon Dilatation Catheter

NC EMERGE TM PTCA Dilatation Catheter

Instructions for Use Cordis PRECISE PRO Rx Nitinol Stent System

Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System

MICHAEL R. JAFF, DO MASSACHUSETTS, UNITED STATES. Medtronic Further. Together

Balloon in Balloon (BIB )

Rationale and algorithm for below-the-knee acute gain optimization

Emerge. PTCA Dilatation Catheter ONLY. monorail. over-the-wire

REBEL. Platinum Chromium Coronary Stent System. Patient Information Guide

INSTRUCTIONS FOR USE

ER REBOA Catheter. Instructions for Use

AXS Catalyst Distal Access Catheter

BTK Case Studies Joseph Cardenas, MD AZ Heart & Vascular, Yuma, AZ

Combine the best of both worlds

Z-MED II BALLOON AORTIC AND PULMONIC VALVULOPLASTY CATHETER. Instructions for Use

System.

ULTRA ICE PLUS ULTRASOUND IMAGING CATHETER. Know where you are. See what you want to avoid.

NIRxcell CoCr Coronary Stent System

Turbo-Power. Laser atherectomy catheter. The standard. for ISR

Wolverine Coronary Cutting Balloon

Talent Abdominal Stent Graft

Quick Reference Guide

The Art of. Flow Restoration. Ikazuchi Zero. Semi-Compliant PTCA Balloon OVERVIEW CROSSABILITY LOW PROFILE CASE STUDY CODES

DISRUPT CAD. Todd J. Brinton, MD Clinical Associate Professor of Medicine Adjunct Professor of Bioengineering Stanford University

Chronic Total Occlusion (CTO) Technologies

Ruby Coil. Large Volume Detachable Coils

DEB experience in Gachon Universtiy Gil Hospital (in ISR) Soon Yong Suh MD., PhD. Heart Center Gachon University Gil Hospital Seoul, Korea.

JETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW

Coronary angiography and PCI

Effectiveness of IVUS in Complex Cases

INSTRUCTIONS FOR USE FOR:

Balloon in Balloon (BIB )

Lutonix AV Clinical Trial

ROTABLATORTM. Peripheral. Rotational Atherectomy System. Quick Reference Cards

Finally, the Control You Need to Deliver Accurate Treatment

Guide Wires design and selection Abbott Vascular. All rights reserved.

Coronary Artery Perforation Angioplasty Summit Seoul April 30, 2005

Intravascular Ultrasound for Complex Cases

For Personal Use. Copyright HMP 2013

Index. Note: Page numbers of article titles are in boldface type.

Complex PCI. Your partner in complex PCI: In-stent restenosis (ISR)

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

Chronic Total Occlusion (CTO) Technologies. Re-open vital channels

Instructions for Use 1

DISRUPT PAD. (( Data Summary )) DISRUPT PAD Data Summary SPL Rev. B 2016 Shockwave Medical Inc. All rights reserved.

STENTYS for Le, Main Sten2ng. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy

Single Pass MCA Revascularization with Trevo

FROM THE EVERYDAY TO THE EXTRAORDINARY

INTRODUCING. Cordis POWERFLEX Pro PTA Dilatation Catheter

LM stenting - Cypher

Sustained Release. Superior Results.

XIENCE Sierra INTRODUCING

Complex ilio-caval revascularization in chronic venous obstruction with the Venovo Stent. Michael K. W. Lichtenberg MD, FESC

TOBA II 12-Month Results Tack Optimized Balloon Angioplasty

CP STENT. Large Diameter, Balloon Expandable Stent

CAROTID ARTERY ANGIOPLASTY

PERFORMANCE YOU CAN TRUST. EverFlex Self-expanding Peripheral Stent with Entrust Delivery System

Vascular V12. Covered Stent. The New Standard of Care

CLARIVEIN INFUSION CATHETER

Christian Wissgott MD, PhD Assistant Director, Radiology Westküstenkliniken Heide

EXPERIENCE MAGIC IN ITS TOUCH

TYSHAK DILATATION CATHETER. Instructions for Use CAUTION: Federal (USA) Law restricts this device to sale by or on the order of a physician.

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

Access More Patients. Customize Each Seal.

PCI for Ostial Lesion

Selection and Use of Basic Equipment : Guiding Catheters, Wires and Balloons

Introduction 3. What is Peripheral Vascular Disease? 5. What Are Some of the Symptoms of Peripheral Vascular Disease? 6

Introduction What Causes Peripheral Vascular Disease? How Do Doctors Treat Peripheral Vascular Disease?... 9

Le# main treatment with Stentys stent. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy

Directions For Use. All directions should be read before use

Radiation Safety Abbott Vascular. All rights reserved.

Protection of side branch is essential in treating bifurcation lesions: overview

Balloon Expandable Covered Stents. Suddenly a Crowded Space

Intravascular Imaging Insights into the Mechanism of Action of Focal Force Balloon Angioplasty

Understanding aneurysms and flow diversion treatment

COIL SYSTEM ORDERING INFORMATION

TAXUS Paclitaxel-Eluting Coronary Stent System

Complex Coronary Interventions: Bifurcations. John M. Lasala MD PhD Professor of Medicine Washington University St Louis, Missouri

Welcome to the 8 th European Bifurcation Club October Barcelona

Off-Label Use Expansion: The CTO Example

LUTONIX DCB in BTK Update on the BTK clinical program & single center experience

Stellarex Drug-coated 0.035" Angioplasty Balloon. Featuring EnduraCoat Technology. The Clear DCB Choice

COMPLEX CASES: LEFT MAIN

Effect of Intravascular Ultrasound- Guided vs. Angiography-Guided Everolimus-Eluting Stent Implantation: the IVUS-XPL Randomized Clinical Trial

MULTIVESSEL PCI. IN DRUG-ELUTING STENT RESTENOSIS DUE TO STENT FRACTURE, TREATED WITH REPEAT DES IMPLANTATION

Indications of Coronary Angiography Dr. Shaheer K. George, M.D Faculty of Medicine, Mansoura University 2014

Transcription:

Innovation by design Technology that sets a new standard Flexible nitinol scoring element with three rectangular spiral struts works in tandem with a semi-compliant balloon to score the target lesion Balloon inflation focuses uniform radial forces along the edges of the nitinol element, scoring the plaque and resulting in a more precise and predictable outcome Low crossing profile (~2.7F), 0.014 RX system compatible with 6F guiding catheters Semi-compliant balloon material allows the physician to tailor the device size to the vessel Two radiopaque markers indicate the working ends of the scoring balloon Nitinol-enhanced balloon deflation for excellent rewrap and recross capabilities Electropolished struts provide a margin of safety, resulting in zero perforations and no slippage.

The AngioSculpt Scoring Balloon Catheter SAFETY SUMMARY Nominal Pressure Rated Burst Pressure Pressure (atm) Catalog Number COMPLIANCE CHARACTERISTICS Balloon Diameter (mm) ORDERING INFORMATION Balloon Length (mm) Balloon Diameter (mm) 2.0 2.5 3.0 3.5 2 1.88 2.28 2.73 3.19 4 1.91 2.35 2.79 3.26 6 1.95 2.40 2.88 3.37 8 2.01 2.49 3.01 3.51 10 2.08 2.59 3.16 3.65 12 2.15 2.69 3.27 3.73 14 2.22 2.77 3.36 3.81 16 2.28 2.85 3.43 3.86 18 2.32 2.89 3.50 3.91 20 2.37 2.95 3.57 3.97 22 2.39 2.99 3.63 Guidewire Compatibility Guide Catheter Compatibility Catheter Length (cm) 2001-2010 2.0 10 0.014 6F 137 2001-2015 2.0 15 0.014 6F 137 2001-2020 2.0 20 0.014 6F 137 2001-2510 2.5 10 0.014 6F 137 2001-2515 2.5 15 0.014 6F 137 2001-2520 2.5 20 0.014 6F 137 2001-3010 3.0 10 0.014 6F 137 2001-3015 3.0 15 0.014 6F 137 2001-3020 3.0 20 0.014 6F 137 2001-3510 3.5 10 0.014 6F 137 2001-3515 3.5 15 0.014 6F 137 2001-3520 3.5 20 0.014 6F 137 To learn more about the clinical advantages of the AngioSculpt Scoring Balloon Catheter, please contact your AngioScore distributor today. The AngioScore PTCA Scoring Balloon Catheter Rapid Exchange (RX) design is not commercially available in the USA. CE Mark Granted for Coronary and Peripheral Applications CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician. 2008 AngioScore, Inc. All Rights Reserved. INDICATIONS The AngioSculpt Scoring Balloon Catheter is indicated for the treatment of a hemodynamically significant coronary artery stenosis, including in-stent restenosis, for the purpose of improving myocardial perfusion. CONTRAINDICATIONS The AngioSculpt catheter should not be used for the following: - Coronary artery lesions unsuitable for treatment by percutaneous revascularization. - Coronary artery spasm in the absence of a significant stenosis. WARNINGS This device is intended for single (one) use only. Do not resterilize and/or reuse, as this can potentially result in compromised device performance and increased risk of inappropriate resterilization and cross contamination. To reduce the potential for vessel damage, the inflated diameter of the balloon should approximate the diameter of the vessel just proximal and distal to the stenosis. PTCA in patients who are not acceptable candidates for coronary artery bypass graft surgery require careful consideration, including possible hemodynamic support during PTCA, as treatment of this patient population carries special risk. When the catheter is exposed to the vascular system, it should be manipulated while under high quality fluoroscopic observation. Do not advance or retract the catheter unless the balloon is fully deflated under vacuum. If resistance is met during manipulation, determine the cause of the resistance before proceeding. Balloon pressure should not exceed the rated burst pressure (RBP). [The RBP is based on results of invitro testing. At least 99.9% of the balloons (with a 95% confidence) will not burst at or below their RBP. Use of a pressure monitoring device is recommended to prevent over-pressurization.] PTCA with the AngioSculpt device should only be performed at hospitals where emergency coronary artery bypass graft surgery can be quickly performed on site (or at a nearby facility) in the event of a potentially injurious or life-threatening complication. Use only the recommended balloon inflation medium. Never use air or any gaseous medium to inflate the balloon. Proceed cautiously when using the AngioSculpt catheter in a freshly deployed bare metal or drug eluting stent. The AngioSculpt catheter has not been tested for post-dilation of stents or in lesions distal to freshly deployed stents in clinical studies. Bench testing has shown no additional risk when inserting or withdrawing the AngioSculpt catheter through stents (no interference with stent struts, no retention of or damage to AngioSculpt catheter). Use the catheter prior to the Use Before (expiration) date specified on the package. PRECAUTIONS Prior to angioplasty, the catheter should be examined to verify functionality, device integrity and to ensure that its size and length are suitable for the specific procedure for which it is to be used. Only physicians trained in the performance of percutaneous transluminal coronary angioplasty should use the catheter system. During and after the procedure, appropriate antiplatelet, anticoagulant and coronary vasodilator therapy consistent with institutional practice or coronary stent procedures should be provided to the patient. Do not rotate the catheter shaft in excess of 180 degrees when the tip is constrained. Do not rotate the catheter luer hub in excess of five (5) turns during use. Do not advance or retract the AngioSculpt catheter over the floppy portion of the guide wire. Catheter manipulation, including advancement and retraction, should be performed by grasping the hypotube shaft. If unusual resistance is felt when the catheter is being manipulated or if it is suspected that the guide wire has become kinked, carefully remove the entire catheter system (AngioSculpt catheter and steerable guide wire) as a unit. If fluoroscopic guidance indicates that the AngioSculpt catheter has advanced beyond the end of the guide wire, withdraw the catheter and reload the wire before advancing again. COMPLICATIONS Possible complications include, but are not limited to, those listed below: Death; Heart Attack (Acute myocardial infarction);total occlusion of the treated coronary artery;coronary artery dissection, perforation, rupture, or injury; Pericardial tamponade No / slow reflow of treated vessel; Emergency coronary artery bypass (CABG); Emergency percutaneous coronary intervention; CVA/stroke; Pseudo-aneurysm; Re-stenosis of the dilated vessel ; Unstable chest pain (angina); Thrombo-embolism or retained device components; Irregular heart rhythm (arrhythmias, including life-threatening ventricular fibrillation); Severe low (hypotension) / high (hypertension) blood pressure;coronary artery spasm; Hemorrhage or hematoma; Need for blood transfusion; Surgical repair of vascular access site; Creation of a pathway for blood flow between the artery and the vein in the groin (Arteriovenous fistula); Drug reactions, allergic reactions to x-ray dye (contrast medium); Infection. REFERENCES: 1. Costa JR, Leon MB, Mintz GS, et al. Impact of different pre-dilatation strategies on stent expansion: an intravascular ultrasound study. Circulation. 2006;114(suppl II):732. 2. Mooney M, Teirstein P, Moses J, et al. Final results from the U.S. multi-center trial of the Angio- Sculpt Scoring Balloon Catheter for the treatment of complex coronary artery lesions. Am J Cardiol. 2006;98(8 suppl):121m. 3. Holmes DR Jr, Mathew V, eds. Atlas of Interventional Cardiology. 2nd ed. Philadelphia, Pa: Current Medicine Group; 2003. 4. AngioSculpt Study Report: Angio- Sculpt efficacy and safety study in a porcine model of coronary artery in-stent restenosis (ISR). March 23, 2003. 5. Vlietstra RE, Holmes DR Jr, eds. Coronary Balloon Angioplasty. Boston, Mass: Blackwell Scientific Publications; 1994:399-451. 6. Sonoda S, Morino Y, Ako J, et al. Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the SIRIUS trial. J Am Coll Cardiol. 2004;43:1959-1963. AngioScore, Inc. 5055 Brandin Court, Fremont, CA 94538 Tel: 510-933-7900 Fax: 510-933-7901 Toll Free: 877-264-4692 info@angioscore.com www.angioscore.com Rev. A 02/08 ML-1050-0001

Changing the landscape of balloon angioplasty for coronary artery disease Rapid Exchange Delivery System

The AngioSculpt Scoring Balloon Catheter: A new dimension in patient outcomes The AngioSculpt Scoring Balloon Catheter transforms the landscape of treating coronary artery disease. It is an essential tool in the treatment of hemodynamically significant coronary artery stenosis, including in-stent restenosis (ISR), for the purpose of improving myocardial perfusion. When used for pre-dilatation prior to stenting, AngioSculpt has been proven to yield a 33%-50% greater luminal gain than either direct stenting or pre-dilatation with a conventional angioplasty balloon catheter. 1 The innovative nitinol scoring element scores the plaque circumferentially, providing a precise and predictable solution to even the most difficult lesion challenges. As demonstrated in clinical studies, AngioSculpt was used successfully in treating fibro-calcific, bifurcation and ostial lesions. AngioSculpt provides the versatility and effectiveness required of a new technology together with the simplicity and deliverability of a high performance balloon catheter. Reduced dissection rates and elastic recoil A NEW MEASURE OF SUCCESS Procedural success rate of 98.5%, with 76% of lesions being types B2/C 2 Freedom from major adverse cardiac events 97.5% 2 Severe dissection post-poba of human coronary artery 3 Post-AngioSculpt scoring of porcine ISR 4 Proven effective in complex calcified (35%), bifurcation (29%) and ostial (13%) lesions 2 Significantly low dissection rate of 13.6% 2 versus ~30% for POBA 5 No device slippage (even in ISR) for more accurate placement and no geographic miss 2 Zero perforations as confirmed by an independent core laboratory 2 Rapid Exchange Delivery System

A new dimension in lesion preparation BETTER FINAL POST-STENT DIMENSIONS Clinical studies show that final stent luminal dimensions are an important predictor of better long-term results 6 Pre-dilatation with AngioSculpt yields a 33% 50% greater luminal gain than direct stenting or pre-dilatation with a conventional angioplasty balloon catheter (p<0.001) 1 Pre-dilatation with AngioSculpt resulted in a post-stent luminal area 5.0 mm 2 89% of the time, compared to only 74% with direct stenting or pre-dilatation with a conventional angioplasty balloon catheter (p<0.001) 1 Acute Gain (mm) 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 100 more luminal gain (p<0.001) 1 0.8 0.4 + 50% gain Pre-dilatation with semi-compliant balloon 0.9 0.2 + Direct stent 33% gain 1.2 0.4 + Note: There was no statistically significant difference between the results for pre-dilatation with a conventional angioplasty balloon and direct stenting. better FINAL luminal dimensions (p<0.001) 1 89 % AngioSculpt achieved larger post-stent luminal dimensions than direct stenting or pre-dilatation with a conventional balloon regardless of the type of lesion plaque morphology (i.e., soft, fibrotic, calcific or Final Stent Area 5.0 mm 2 (%) 80 60 40 20 74.4 % 73.8 % mixed plaque) 1 0 Pre-dilatation with semi-compliant balloon Direct stent Note: There was no statistically significant difference between the results for pre-dilatation with a conventional angioplasty balloon and direct stenting.

A versatile tool for treating bifurcation lesions Pre-treatment: AngioSculpt placed at side branch in bifurcation lesion Post-treatment: AngioSculpt used as stand-alone treatment in side branch and pre-dilatation tool in main branch The clinical challenges common in bifurcation lesions dissection, slippage and plaque shifting can make a lengthy procedure even longer. AngioSculpt offers physicians an effective, time-saving tool for treating the unique challenges of bifurcation lesions. No device slippage 2 for precise and predictable treatment of the target lesion Uniform, radial, scoring forces beneficial for treating elastin-rich ostial lesions Low dissection rates 2 may lead to reduced need for bail-out stenting Electropolished nitinol edges provide a margin of safety in complex anatomy Better final luminal dimensions in the main branch post-stenting 1 Rapid Exchange Delivery System