Pacing Lead Implant Testing. Document Identifier

Similar documents
Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

Figure 2. Normal ECG tracing. Table 1.

Timing cycles. Objectives Upon completion of this program the participant will be able to:

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

Presented By: Barbara Furry, RN-BC, MS, CCRN, FAHA Director The Center of Excellence in Education Director of HERO

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

Sinus rhythm with premature atrial beats 2 and 6 (see Lead II).

RN-BC, MS, CCRN, FAHA

Intermittent episodes of paced tachycardia: what is the cause?

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Title and contents page 1 Who should read this document 2 Scope of the Guideline 2 Background 2 What is new in this version 2

Pacing troubleshooting. NASPE training Lancashire & South Cumbria Cardiac Network

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

Supplemental Material

Temporary pacemaker 삼성서울병원 심장혈관센터심장검사실 박정왜 RN, CCDS

Single-Lead DDD System: A Comparative Evaluation of Unipolar, Bipolar and Overlapping Biphasic Stimulation

Advanced ICD Concepts

SARASOTA MEMORIAL HOSPITAL

Pacing and Device Jargon Made Simple. Dr Jonathan Timperley MB ChB MD FRCP Consultant Cardiologist Northampton General Hospital


PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

DEFIBRILLATORS ATRIAL AND VENTRICULAR FIBRILLATION

Pediatric pacemakers & ICDs:

Programming of Bradycardic Parameters. C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany

Clinical Data Summary: Avoid FFS Study

Project Title Temporary Pacemaker Training Simulator

ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ

The Electrocardiogram

Chapter 80 Implantable Cardiac Devices

CORONARY ARTERIES HEART

ICD: Basics, Programming and Trouble-shooting

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev

A Rare Type of Pacemaker Mediated Tachycardia

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

Chapter 3 Biological measurement 3.1 Nerve conduction

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

Friedman, Rott, Wokhlu, Asirvatham, Hayes 201. Figure 65.7 Shortening of the AV interval during pacing.

FINELINE II STEROX EZ Models 4469/4470/4471/4472/4473/4474 Guidant Implantable Pacing Lead

The Nuts and Bolts of ICD Therapy

Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms

You have a what, inside you?

You have a what, inside you?

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Electrocardiography for Healthcare Professionals

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing

Practice Questions.

Solara CRT-P MRI SureScan W1TR06

Physician s Manual. ENDOTAK RELIANCE TM Models 0147/0148/0149. ENDOTAK RELIANCE TM S Models 0127/0128/0129

Pacemakers, Defibrillators, and Electrophysiology in 2012

PROCEDURAL ASSESSMENT CHECKLIST PACEMAKER IMPLANT PROCEDURE. Fellow: Supervising Physician: Date of Observation:

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

Reviewed Date: Supersedes (Policy #/description & date): Prepared by: Jacque Callis, RN Approved by: D.R. Johnson, MD

Is This Thing Working?

UnitedHealthcare Medicare Advantage Cardiology Prior Authorization Program

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART II

Contents. Example: Pacemaker in DDD Mode. I. Introduction II. Website and Relevant Documents III. Background Information IV.

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

Implantable Cardioverter-Defibril. Defibrillators. Ratko Magjarević

Transvenous Pacemaker Procedures

Finally, a pacemaker may be either permanent or temporary, which will also factor into your code selections.

Kadlec Regional Medical Center Cardiac Electrophysiology

Advisa MRI and Ensura MRI SureScan pacing systems

Influence of Postural Position, Respiratory Maneuvers and Exercise on Atrial Electrograms

Temporary Pacemakers

Size (mm) (H W D) Mass (g) Volume (cc)

How to Approach the Patient with CRT and Recurrent Heart Failure

Long Term Monitoring of the Intrinsic Ventricular Monophasic Action Potential with an Implantable DDD Pacemaker

(51) Int Cl.: A61N 1/37 ( )

Ventricular Capture Control and the Increase of Pacemaker Lifetime

There are different types of ICDs:

Electrocardiography Biomedical Engineering Kaj-Åge Henneberg

INTERNAL CARDIOVERSION. Lancashire & South Cumbria Cardiac Network

Lab #3: Electrocardiogram (ECG / EKG)

Outline. Electrical Activity of the Human Heart. What is the Heart? The Heart as a Pump. Anatomy of the Heart. The Hard Work

Principles and Applications of Electrical Circuits and Signal Theories in EP

TIP CARD. Model Temporary External Pacemaker

6to. Congreso Virtual de Cardiología - 6th. Virtual Congress of Cardiology

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER

GDT1000 SENSING ACUTE STUDY

Implantable cardioverter defibrillator, Inappropriate shock, Lead failure

Positive Results with a New Screw-in Electrode with Isolated Screw and Fractal Coating of the Ring: the RETROX Electrode in the Atrial Position

Physician s Manual FLEXTEND. Steroid-Eluting Extendable/Retractable Helix Pace/Sense Leads MODELS: 4086/4087/4088

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

M Series with Rectilinear Biphasic Waveform Defibrillator Option Indications for Use

Chapter 16: Arrhythmias and Conduction Disturbances

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

EASYTRAK 2 Coronary Venous Steroid-Eluting Bipolar Pace/Sense Lead

Diagnostic capabilities of the implantable therapeutic systems

Cardiac Resynchronisation Therapy Patient Information

Supplementary Online Content

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers

Leadless Pacing. Osama Diab Assistant Prof. of Cardiology Ain Shams University Egypt

OLBI Stimulation in Biatrial Pacing? A Comparison of Acute Pacing and Sensing Conditions for Split Bipolar and Dual Cathodal Unipolar Configurations

ICD Implantation Patient Information

SUPPLEMENTAL MATERIAL

3/26/15 HTEC 91. EKG Sign-in Book. The Cardiac Cycle. Parts of the ECG. Waves. Waves. Review of protocol Review of placement of chest leads (V1, V2)

EKG Competency for Agency

DEFIBRILLATORS. Prof. Yasser Mostafa Kadah

Transcription:

Pacing Lead Implant Testing 1

Objectives Upon completion of this presentation, the participant should be able to: Name the two primary surgical options for implanting pacing leads Describe three significant PSA measurements that should be taken during lead implantation Explain how lead measurements are used to determine device parameters in conjunction with specific patient needs 2 2

Implant Equipment and Room Set-Up The EP lab/surgical suite equipment consists of: Fluoroscopic imaging Patient hemodynamic monitors (EKG, blood pressure, pulse oximeter ) External defibrillator- external pacemaker Sterile table and instruments 3 3

Draping 4 4

Sterile Table Pacemaker tray Surgical instruments Drapes Cautery equipment Sterile basins 5 5

Pre-implant Preparation ECG and blood pressure monitoring equipment is attached to the patient Gentle restraints may be applied Skin is shaved and prepped Surgical area is cordoned off with sterile towels Patient s entire body is draped 6 6

Administration of Local Anesthetic The skin is numbed with Xylocaine A sedative is usually given prior to the procedure to help relieve anxiety 7 7

Permanent Pacemaker Insertion Introducer Kit Introducer kit Introducer sheath Guide wire Needle with syringe 8 8

Venous Access Sites 9 9

Venous Access: Surgical Methods Subclavian or Cephalic Cutdown The cephalic vein travels from the arm, through the deltopectoral groove, and joins the subclavian vein. 10 10

Venous Access: Subclavian Stick Percutaneous Subclavian Approach 11 11

12

Implant Measurements Sensing Threshold Pacing Impedance Stimulation Threshold Slew Rate Retrograde Conduction Time Diaphragmatic / Phrenic Nerve Stimulation Note: Implant measurements via the PSA are documented in the Guidant implant form(s) and patient file. Confirm with your region. 13 13

Target Values with Pacing System Analyzer Acute (PSA) Chronic Sensing Threshold Atrial > 1 mv > 1 mv Ventricular > 10 mv > 10 mv Impedance 300 1500 ohms* * Different tip electrode and/or lead design characteristics may result in lead impedances normally falling outside this range and/or being consistently at one end of the range, i.e., high-impedance leads DSP/ENDURANCE EZ = 300 1000 ohms ENDURANCE RX/RELIANCE = 500 1500 ohms Shocking Electrode (Dual coil) = 20 80 ohms Stimulation Threshold Voltage (at 0.5 ms) Atrial < 1.0 V < 1.5 V Ventricular ENDOTAK < 1.0 V < 1.0 V < 1.5 V < 1.5V Current (at 0.5 ms) Atrial < 1.5 ma < 6 ma Ventricular < 1.5 ma < 6 ma Slew Rate Atrial > 0.3 V/sec (mv/ms) > 0.3 V/sec Ventricle > 1.0 V/sec > 0.5 V/sec Retrograde Conduction Time (RCT) VDD/DDD 100 400 ms (stable value if present) For 14 Guidant field personnel education use only. Not to be duplicated 14

Implant Measurements Sensing Threshold (P & R-Wave Amplitudes) The minimum intrinsic electrical signal (P-wave and/or R-wave), expressed in millivolts (mv), required for consistent sensing by a pacemaker s sensing amplifier(s) Intrinsic measurement No pacing during test Reference: Guidant PGs measure baseline-to-peak and the Biotronik PSA measures peak-to-peak Peak-to-peak (Biotronik) Baseline-to-peak (Guidant) 15 15

Implant Measurements Sensing Threshold Purpose: To assure that intrinsic signal is of adequate amplitude to be detected by the pulse generator and inhibit pacing To assure proper lead placement To assure pacing system integrity Lead integrity Lead-to-tissue interface Sensing Threshold Pacing Impedance Stimulation Threshold Slew Rate Retrograde Conduction Time Diaphragmatic / Phrenic Nerve Stimulation 16 16

Implant Measurements Sensing Threshold (P & R Wave Amplitudes) Proper sensing depends on: Signal amplitude (mv) Frequency (Hz) Slew rate (V/sec) Bandpass Filter The PG Bandpass Filter attenuates signals which are not typical of P and R-wave frequency, so they will not be sensed. Conversely, it amplifies signals which are of an appropriate frequency, to increase the likelihood of sensing. 17 17

Implant Measurements Sensing Threshold (P & R Wave Amplitudes) Figure A: an electrogram taken at time of implantation with a marked ST elevation due to localized myocardial damage Figure B: an electrogram taken approximately 3 months after implantation with no S-T elevation and a somewhat lower amplitude 18 18

Implant Measurements Programming Guidelines for Sensitivity Acute Typically at nominal sensitivity setting or lower Minimum: At least twice as sensitive as the measured intrinsic signal amplitude Setting at ½ or less than the mv measurement of the signal (i.e., 5 mv R-wave requires setting of 2.5 mv or less, 2 mv P-wave requires setting of 1 mv or less) Chronic (6 weeks to 3 months post implant) At least twice as sensitive as the measured intrinsic signal amplitude 19 19

Impedance Implant Measurements Total opposition to flow of electrical current through the lead conductor(s), electrodes, electrode/ myocardial tissue interface and body fluids/ tissues Requires delivery of pacing pulse Measured in ohms ( ) May also be known as Resistance 20 20

Impedance Purpose: Implant Measurements To verify lead integrity Insulation compromised = lowered impedance Conductor compromised = higher impedance Sensing Threshold Pacing Impedance Stimulation Threshold Slew Rate Retrograde Conduction Time Diaphragmatic / Phrenic Nerve Stimulation 21 To verify stable lead-to-tissue interface Stable interface = stable impedance Unstable interface = fluctuating impedance 21

Implant Measurements Stimulation Threshold The minimum amount of electrical stimulation that consistently produces cardiac depolarization (captures) Also called Pacing Threshold or Capture Threshold Typically measured as voltage (V) at a given pulse width (usually 0.5 ms) May also be measured as current (10-3 or ma) Threshold value is the minimum voltage that regains consistent capture after losing capture when decrementing the voltage 22 22

Purpose: Implant Measurements Stimulation Threshold To assure adequate safety margin between the stimulation threshold and the programmed output of the pulse generator To assure proper lead placement To assure pacing system integrity Lead integrity Lead-to-tissue interface Sensing Threshold Pacing Impedance Stimulation Threshold Slew Rate Retrograde Conduction Time Diaphragmatic / Phrenic Nerve Stimulation 23 23

Implant Measurements Stimulation Threshold: Acute to Chronic Transition Presence of electrode next to endocardial surface causes an inflammatory reaction which heals within the first few months, leaving behind a small fibrotic capsule around the electrode Figure A: Acute threshold at implant Figure B: Peak threshold approx. 1-4 weeks post implant Figure C: Stable chronic threshold approx. 6-12 weeks post implant 24 24

VOLTAGE THRESHOLD Implant Measurements Stimulation Threshold Affected by: Lead maturation Lead technology Lead placement Medications Electrolyte imbalance Peak NON-STEROID STEROID Acute Phase Chronic Phase 1-6 weeks 6-12 weeks Implant Time 25 25

Acute Implant Measurements Programming Guidelines for Pacing Outputs Typically at nominal amplitude (voltage) and pulse width settings or higher Minimum amplitude: 2x stimulation threshold Chronic 2x stimulation threshold or 3x pulse width threshold Ventricular channel may be programmed higher in pacemaker dependent patients 26 26

Slew Rate Implant Measurements The maximal change in amplitude (voltage) in the electrogram over time Intrinsic measurement Slope of the signal Measured in volts per second (V/sec) or millivolts per milliseconds (mv/ms) Amplitude (mv) 27 Time (ms) 27

Slew Rate Purpose: Implant Measurements To help ensure appropriate sensing Generally the higher the slew rate, the higher the frequency content of the signal and the more likely it is to be sensed May be used as an adjunct measurement if signal amplitude is borderline acceptable or unacceptable Sensing Threshold Pacing Impedance Stimulation Threshold Slew Rate Retrograde Conduction Time Diaphragmatic / Phrenic Nerve Stimulation 28 28

Slew Rate Implant Measurements Slew rate, or the length of time for an R-wave to reach peak amplitude, has an effect on sensing because of its frequency and amplitude characteristics. When the slew rate is low (V = <.5 V/sec. A = <.3V/sec.), the frequency is also low, and therefore a larger amplitude is needed before an R-wave can be sensed. Signals with low slew rates can potentially result in undersensing Leads designed to minimize fibrotic capsule thickness can overcome sensing difficulties resulting from low slew rates 29 29

Implant Measurements Retrograde Conduction Time Period of time it takes an electrical impulse originating in the ventricles to travel through the conduction system to the atria where it causes atrial depolarization (retrograde P-wave) Ventriculoatrial (VA) conduction may result if AV synchrony is dissociated by any event, i.e., PVC PVC Retrograde P-wave Retrograde conduction time 30 30

Implant Measurements Retrograde Conduction Time (VA Conduction) Retrograde conduction may result in Pacemaker-Mediated Tachycardia (PMT) or Endless-loop Tachycardia in an atrial-tracking pacing mode if retrograde P-wave is sensed by the atrial sensing circuit, it begins an AV delay PMT is ventricular pacing at the Maximum Tracking Rate (MTR) Testing may be deferred until post-implant follow-up using EGMs and/or event markers from device and programmer 31 31

Implant Measurements Retrograde Conduction Time (VA conduction) Purpose: To prevent retrograde-induced pacemaker mediated tachycardia by optimally programming Post- Ventricular Atrial Refractory Period (PVARP) Sensing Threshold Pacing Impedance Stimulation Threshold Slew Rate Retrograde Conduction Time Diaphragmatic / Phrenic Nerve Stimulation 32 32

Implant Measurements Programming Recommendations Program PVARP at least 25 ms longer than measured retrograde conduction time. Retrograde conduction times may vary with rate (100 400 ms). Program on other special features designed to prevent/terminate PMT, i.e. PVARP After PVC, PMT Termination feature, etc. Program other parameters to help ensure AV synchrony maintained, i.e. appropriate AV Delay 67% of patients with sinus node dysfunction and 14% of patients with fixed complete heart block have retrograde conduction 33 Seymour Furman, MD. A practice of Cardiac Pacing, 1989 33

Implant Measurements Diaphragmatic/Phrenic Nerve Stimulation Test by providing temporary high output (10 V) pacing through each implanted lead to assess for phrenic nerve stimulation with atrial lead and diaphragmatic stimulation with ventricular lead. May observe ( hiccoughing) or pectoral muscle stimulation ( pocket twitching ) from pacer output If nerve/muscle stimulation observed: Determine minimum output it occurs May need to reposition lead(s) 34 34

Implant Measurements Diaphragmatic/Phrenic Nerve Stimulation Purpose: To prevent nerve or muscle stimulation from pacer output Sensing Threshold Pacing Impedance Stimulation Threshold Slew Rate Retrograde Conduction Time Diaphragmatic / Phrenic Nerve Stimulation 35 35

Device Implanted Evaluation of pacing lead measurements are repeated and final device programming is done prior to patient leaving the O.R. Sensing Threshold Pacing Impedance Stimulation Threshold ZOOM Design Philosophy Make it easy Save the clinician time Deliver a quality ECG 36 36

Implant Measurements Sample Implant Data Form Purpose: To document measurements taken during the procedure Patient Name: Pacemaker Model: Ventricular Lead: Atrial Lead: Date: S/N: S/N: S/N: Atrial Lead Ventricular Lead Lead Impedance: Lead Impedance: Threshold: Threshold: P-Waves: R-Waves: Check @ 10V: Check @ 10 V: Slew Rate: Retrograde Conduction Test: Programmed Parameters: Mode: A V Lower Rate Limit: Amplitude MTR/MSR Pulse Width AV Delay Sensitivity Other parameters: GUIDANT Representative: 37 37

Final Steps Complete Guidant implant forms and return to Guidant Medical Records Ensure lead measurements and final device programming information is documented in patient chart according to hospital-specific protocol 38 38

Summary Name the two primary surgical options for implanting pacing leads: Subclavian Stick and Cephalic Cutdown Describe the three significant PSA measurements that should be taken during lead implantation: Sensing Threshold, Impedance, Stimulation Threshold; (Others: Slew Rate, Retrograde Conduction, and Diaphragmatic/Phrenic Nerve Stimulation) Explain how lead measurements are used to determine device parameters in conjunction with patient needs: Amplitude, Sensitivity, PVARP, etc. 39 39

Target Values with Pacing System Analyzer (PSA) References Ellenbogen K. Cardiac Pacing Second Edition, Blackwell Science, Inc. 1996 Furman S, et al. A Practice of Cardiac Pacing Third Edition, Futura Publishing Company, Inc. 1993 Hayes D, et al. Cardiac Pacing and Defibrillation: A Clinical Approach Futura Publishing Company, Inc. 2000 Moses H, et al. A Practical Guide to Cardiac Pacing Fourth Edition, Little, Brown and Company. 1995 AICD System Guide (PRIZM) Guidant 2000 Physician s Manual (ENDURANCE) Guidant 1998 Physician s Manual (RELIANCE) Guidant 2000 40 40