InfinityLab Purification Capillary Kits

Similar documents
Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Chiral Multicolumn Method Development on the Agilent 1260 Infinity II SFC System

Agilent 1260 Infinity Analytical SFC System

Agilent 1260 Infinity Analytical Hybrid SFC/UHPLC system

Chiral Screening for SFC and UHPLC with the Agilent 1260 Infinity II SFC/UHPLC Hybrid System

ICP-OES Organics Kit Installation Instructions

QuickSplitTM Flow Splitters

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Performance Characteristics of the Agilent 1290 Infinity II Multicolumn Thermostat

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Comparison of a UPLC Method across Multiple UHPLC Systems

2D-LC as an Automated Desalting Tool for MSD Analysis

More accurate results.

Performance characteristics of the Agilent 1100 Series preparative pump. Technical Note. Abstract

Agilent 1220 Infinity LC System Performance Specifications

Calibration Standards

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

PEEK SS Columns & Guard Columns

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF

Needle Gauge. Needle OD (mm) Needle ID (mm)

Thermo Finnigan. 6-2 LCQ Advantage Getting Started-

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Optimizing Chiral Separations and Purification of Enantiomers Through Selective Sample Slicing and Column Switching

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Lipidomic Analysis by UPLC-QTOF MS

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

QuickSplit TM Flow Splitters

Technical Data Sheet SONOFLOW CO.55 V1.0

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

HPLC to UHPLC Transfer of USP Method for Amlodipine Besylate Using the Agilent 1290 Infinity II LC

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2

Purification - Flash Chromatography

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

injections. Needle Tip 1 µl Cone 1BR

HPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Online 2D-LC Analysis of Complex N-Glycans in Biopharmaceuticals Using the Agilent 1290 Infinity 2D-LC Solution

autosamplers ASI-100 and ASI-100T Autosamplers

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Application Note. Preparative Isolation of Piperine from Black Pepper Extracts. Summary. Introduction. Fig. 1

Am I getting the very best value from my UHPLC analyses?

Analysis of Vitamins Using an SFC/UHPLC Hybrid System with a Triple Quadrupole LC/MS for Quantification

Analysis of bisphenol A leaching from baby feeding bottles

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

HPLC. Varian Dynamax Preparative HPLC Columns

Parts and Consumables. Sciclone ALH 3000 and Zephyr Liquid Handlers

Purification - Flash Chromatography

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Edgar Naegele. Abstract

Application Note. Authors. Abstract. Petrochemical

With extended functionality the sensors are also applicable for the detection of air bubbles.

Fig.1. Denatonium benzoate (DB) chemical structure

cataleg-inl-2007-def6.indd /01/ :27:30

By: Stephanie Bendtsen, Joseph Calderan, and Celeste Dupont Team 17 Client: Dr. Sun

Gas Chromatography Syringe Selection Guide

Extended Application Note

Hamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles

ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I

10 mg in 1.4 ml. XTerra MS C 18, 4.6 x 50 mm. Volume injected: Injector Column. Waste. Pump. Pump. Splitter

Doubling the throughput of long chromatographic methods by using a novel Dual LC workflow

Application Note. Purification of ω-3-fatty acids from fish oil using MCSGP. Summary. Countercurrent chromatography, multicolumn.

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC

Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides Isolated From Stevia rebaudiana Bertoni

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

SUN VALLEY STOVE COMPANY

SUPERCRITICAL FLUID EXTRACTION OF TETRAHYDROCANNABINOL FROM MARIHUANA. DETERMINATION OF TETRAHYDROCANNABINOL AND TETRAHYDROCANNABINOL ACID

Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

Agilent 7700x ICP-MS

Instrument Assembly Quick Guide

Designing an Extractables and Leachables Study

Forensic Analysis of Blood Alcohol Concentration

INSTALLATION INSTRUCTIONS

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Radnoti Langendorff Constant Pressure Non-Recirculating Pump Driven Isolated Heart System For Mouse EZ

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

In-Line Accessories. In-Line Pressure Gauges. Pressure Gauges. In-Line Accessories

VENTILATOR PRODUCT ACCESSORIES CATALOG

PROXIMAL TIBIAL PLATE

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

AUTOMATED LIQUID HANDLING

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

MICS & FEMORAL CANNULAE

GASTRO-INTESTINAL (ENTERAL)

Transcription:

InfinityLab Purification Capillary Kits Technical Note This note describes the capillary connections for Agilent preparative systems. Agilent Technologies

Contents Abbreviations 3 List of Modules 4 Overview 5 General Installation Notes 5 Installation Notes for 1260 Infinity II Column Organizer G9328A 6 Installation Notes for 1290 Infinity II Column Compartment G7163B 8 Configurations with 1260 Infinity II Column Organizer (G9328A) 10 Entry Level System Configurations (with Manual Injector) 10 Standard UV/LC System Configurations 16 Standard Mass-Based Systems Configuration 24 Configurations with 1290 Infinity II Preparative Column Compartment (G7163B) 28 Entry Level System Configurations (with Manual Injector) 28 Standard UV/LC System Configurations 34 Standard Mass-Based System Configurations 40 Accessories 44 UV Accessories 44 MS Accessories 44 2

Abbreviations Table 1 Abbreviations Modules VWD Variable wavelength detector Diode array detector MI Manual Injector DC Delay Coil Organizer RC Recovery collector FC Fraction collector PRV Pressure relieve valve BPR Back pressure regulator FM Flow modulator Fittings R fitting for flex capillaries: 5067-5966 for rigid capillaries: 5067-5403 S lock fitting Capillaries and tubings UV1...5 Capillaries to connect the s of the liquid chromatographic part of the system MS1...6 Capillaries to connect the s of the mass spectrometric part of the system 0.3f 0.3 ID flex capillary 0.5r 0.5 ID rigid capillary ESD Electrostatic discharge Material SST Stainless steel PTFE Polytetrafluorethylene PEEK Polyether ether ketone 3

List of Modules Table 2 G7161A G7161B G7114A G7115A G7165A G7159B G7166A G1364E G1328D G7157A G7170B G9324A List of s 1260 Infinity II Preparative Binary Pump 1290 Infinity II Preparative Binary Pump 1260 Infinity II Variable Wavelength Detector 1260 Infinity II Diode Array Detector WR 1260 Infinity II Multiple Wavelength Detector 1290 Infinity II Preparative Open-Bed Fraction Collecor 1260 Infinity II Preparative Valve-Based Fraction Collector 1260 Infinity II Preparative Fraction Collector 1260 Infinity II Manual Preparative Injector 1260 Infinity II Preparative Autosampler 1290 Infinity II MS Flow Modulator 1260 Infinity II Delay Coil Organizer 5067-6857 PREP Pressure Relief Valve Kit G7163B G9328A G7110A 1290 Infinity II Preparative Column Compartment 1260 Infinity II Column Organizer 1260 Infinity II Isocratic Pump 5188-8053 ERI Remote and Leak Module G6125B MSD 4

Overview General Installation Notes Capillaries and Fittings Capillary UV/LC kits (5067-6858, 5067-6859, 5067-6860, 5067-6809) are flow dependent. The proper kit needs to be selected based on the desired flow range. The MS Upgrade kit (5067-6861) is only one kit. It contains all capillaries for all flow ranges. Four capillaries (UV2A, 2B, 2C, 2D) are provided to connect sampler and column. All capillaries with an inner diameter (ID) of 0.3 and 0.5 are flexible. Only the MS1B capillary from column to flow modulator is always rigid. This capillary is guided between s and needs to remain in its fixed position. The bypass of the flow modulator is part of accessory kit G7170-68705. All capillaries going to the ports of the flow modulator need UHP-FF fittings. NOTE Do not use swagelock for the flow modulator, the ports can be damaged. The Multiple Wavelength Detector is not depicted in the drawings. The same principles as for the Diode Array Detector apply. Only removable fittings are used for columns. Either Quick Turn Fittings for flexible capillaries, or UHP-FF for rigid capillaries. General rules If the height of the stack configuration exceeds the safety limit (0.89 m), the solvent cabinet has to be placed next to the stack on the base plate. The base plate is needed in case the Solvent Cabinet is placed on a bench by itself, and has to be ordered separately (p/n G1328-44111). 5

Installation Notes for 1260 Infinity II Column Organizer G9328A Columns and Column Holders To keep the capillary from column to detector as short as possible, the column needs to be mounted at the highest possible position, and in the front of the column organizer. Two capillaries (UV2A, UV2B) are provided to connect sampler and column: UV2A is used for columns shorter than 15 cm, UV2B is used for long columns of 15 cm and more. Fix columns with the following column holders: M size holders (5067-6849) for 9.4 /10, 21.2 and 30 columns, L size holders (G7163-60002) for 50 columns, L size holders have to be ordered separately. The 25 cm columns require two M size holders, shorter columns need only one holder. One M holder can be used for pre-column. Manual Injection Valve G1328D (MI) The MI must be installed in the first groove of the column organizer extrusion plate. The MI can be installed at any height. In combination with columns shorter than 25 cm, the MI can be positioned in the middle of the column organizer. In combination with columns 25 cm or longer, the MI needs to be installed at the lowest possible position. The MI requires a suitable waste container (bottle or beaker) for waste and siphoning capillaries. NOTE The kit does not contain a waste container. The waste container must be provided by the customer. The waste container has to be placed on the leak plate. 6

In the case that a 20 ml stainless steel loop is used, it has to be bent in the direction of the extrusion to leave enough space for the container on the leak plate. None of the other loops limit the space for the container. The waste and siphoning capillaries have to be bent. The end of the capillaries have to be at the same height as the position of the injection needle. Pressure Relieve Valve (PRV, 5067-6857) and Back Pressure Regulator (BPR, 5067-6840) PRV must be installed with every configuration. NOTE The PRV is required for safety reasons. The PRV and BPR come with the Preparative LC system. The PRV is installed at the outlet of the Delay Coil Organizer, if available. If the PRV is used as a single item, the following measures are required: The PRV has to be connected with system tubing from the detector. This connection requires union 10-32 to ¼-28. The PRV has to be fixed to the column organizer using S holders. The PRV has to be placed on the upper part of the extrusion. NOTE The length of the capillary from the detector to the PRV is intentionally limited. The PRV waste tubing is guided to the leak plate by S holders. The BPR needs to be installed ahead of the Recovery Collector. The use of BPR is recoended only for certain flow rates, check for operating instructions. The BPR can be fixed at any position on the extrusion using S holders. 7

Installation Notes for 1290 Infinity II Column Compartment G7163B General The Delay Coil Organizer must be installed at the highest valve position. The Flow Modulator must be installed in the second highest valve position. The Recovery Collector can be installed at any available free valve position. Columns and Column Holders The column should be mounted at the highest possible position of the Column Compartment. The capillaries UV2A, UV2B, UV2C and UV2D are used to connect the column with the sampler. Select the suitable capillary length depending on the position or length of the column. Fix columns with the following column holders: M size holders (5067-6849) for 9.4 /10, 21.2 and 30 columns, L size holders (G7163-60002) for 50 columns, The 25 cm columns require two M size holders, shorter columns need only one M size holder. One M size holder can be used for pre-column. Manual Injection Valve G1328D (MI) The MI should be installed on the bottom part of the small mounting plate of the Column Compartment in the first groove. The MI requires a suitable waste container (bottle or beaker) for waste and siphoning capillaries. NOTE The kit does not contain a waste container. The waste container must be provided by the customer. The waste container has to be placed on the plateau of the Column Compartment. Columns need to be installed such that they do not collide with MI, loop or siphoning capillaries, usually on the left part of the extrusion. 8

The waste and siphoning capillaries have to be bent. The end of the capillaries have to be at the same height as the position of injection needle and should point down to the waste container. Pressure Relieve Valve (PRV, 5067-6857) and Back Pressure Regulator (BPR, 5067-6840) PRV must be installed with every configuration. NOTE The PRV is required for safety reasons. The PRV and BPR come with the Preparative LC system. The PRV is installed at the outlet of the Delay Coil Organizer, if available. If the PRV is used as a single item, the following measures are required: The PRV has to be connected with system tubing from the detector. This connection requires union 10-32 to ¼-28. The PRV has to be fixed to the Column Compartment using S holders (5043-1356). The PRV has to be placed on the upper part of the extrusion. NOTE The length of the capillary from the detector to the PRV is intentionally limited. The PRV waste tubing is guided to the leak sensor by S holders. The use of BPR is recoended only for certain flow rates, check for operating instructions. The BPR can be fixed at any position on the extrusion using S holders. 9

Configurations with 1260 Infinity II Column Organizer (G9328A) Entry Level System Configurations (with Manual Injector) Entry Level System Configurations Table 3 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV 5067-6858 5067-6859 5067-6860 5067-6809 1 kit for each flow rate Flow range 4 8mL/min 15 80 ml/min 80 From To Length /cm Fittings UV1 Pump Sampler 65 0.3f 5500-1308 1309 1318 1390 UV2A Sampler Column 50 0.3f 5500-1316 1317 1320 1391 UV2B Sampler Column 65 0.3f 5500- UV3 Column VWD/ 65 0.3f 5500- - UV4 VWD/ DC Box/ PRV 55 0.3f 5500-1408 1386 0.7r 5500-1389 1395 UV5 VWD/ PRV 65 0.3f 5500-1308 1309 1318 1390 10

Table 4 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G9321-60953) Tubing Kit 50 (G9321-60952) Tubing Kit 150 (G9321-60954) Tubing Kit 200 (G9321-60951) Suitable for the flow up to 1 8 ml/min 15 50 ml/min 50 150 ml/min 150 Table 5 Preparative Fraction Collector tubing kits (G1364E) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Fraction Collector tubing kit G1364-68603 G1364-68604 G1364-68605 Coent 4 8 ml/min 15 100 ml/min 11

12

Entry Level System Configurations with Delay Coil Organizer (G9324A) Table 6 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV 5067-6858 5067-6859 5067-6860 5067-6809 1 kit for each flow rate Flow range 4 8mL/min 15 80 ml/min 80 From To Length /cm Fittings UV1 Pump Sampler 65 0.3f 5500-1308 1309 1318 1390 UV2A Sampler Column 50 0.3f 5500-1316 1317 1320 1391 UV2B Sampler Column 65 0.3f 5500- UV3 Column VWD/ 65 0.3f 5500- - UV4 VWD/ DC Box/ PRV 55 0.3f 5500-1408 1386 0.7r 5500-1389 1395 UV5 VWD/ PRV 65 0.3f 5500-1308 1309 1318 1390 Table 7 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G9321-60953) Tubing Kit 50 (G9321-60952) Tubing Kit 150 (G9321-60954) Tubing Kit 200 (G9321-60951) Suitable for the flow up to 1 8 ml/min 15 50 ml/min 50 150 ml/min 150 13

Table 8 Preparative Fraction Collector tubing kits (G1364E) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Fraction Collector tubing kit G1364-68603 G1364-68604 G1364-68605 Coent 4 8 ml/min 15 100 ml/min 14

15

Standard UV/LC System Configurations Configuration with Preparative Open-Bed Fraction Collector Table 9 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV 5067-6858 5067-6859 5067-6860 5067-6809 1 kit for each flow rate Flow range 4 8mL/min 15 80 ml/min 80 From To Length /cm Fittings UV1 Pump Sampler 65 0.3f 5500-1308 1309 1318 1390 UV2A Sampler Column 50 0.3f 5500-1316 1317 1320 1391 UV2B Sampler Column 65 0.3f 5500- UV3 Column VWD/ 65 0.3f 5500- - UV4 VWD/ DC Box/ PRV 55 0.3f 5500-1408 1386 0.7r 5500-1389 1395 UV5 VWD/ PRV 65 0.3f 5500-1308 1309 1318 1390 Table 10 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G9321-60953) Tubing Kit 50 (G9321-60952) Tubing Kit 150 (G9321-60954) Tubing Kit 200 (G9321-60951) Suitable for the flow up to 1 8 ml/min 15 50 ml/min 50 150 ml/min 150 16

17

Configuration with Preparative Open-Bed Fraction Collector and Delay Coil Organizer (G9324) Table 11 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV 5067-6858 5067-6859 5067-6860 5067-6809 1 kit for each flow rate Flow range 4 8mL/min 15 80 ml/min 80 From To Length /cm Fittings UV1 Pump Sampler 65 0.3f 5500-1308 1309 1318 1390 UV2A Sampler Column 50 0.3f 5500-1316 1317 1320 1391 UV2B Sampler Column 65 0.3f 5500- UV3 Column VWD/ 65 0.3f 5500- - UV4 VWD/ DC Box/ PRV 55 0.3f 5500-1408 1386 0.7r 5500-1389 1395 UV5 VWD/ PRV 65 0.3f 5500-1308 1309 1318 1390 Table 12 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G9321-60953) Tubing Kit 50 (G9321-60952) Tubing Kit 150 (G9321-60954) Tubing Kit 200 (G9321-60951) Suitable for the flow up to 1 8 ml/min 15 50 ml/min 50 150 ml/min 150 18

19

Configuration with Preparative Fraction Collector Table 13 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV 5067-6858 5067-6859 5067-6860 5067-6809 1 kit for each flow rate Flow range 4 8mL/min 15 80 ml/min 80 From To Length /cm Fittings UV1 Pump Sampler 65 0.3f 5500-1308 1309 1318 1390 UV2A Sampler Column 50 0.3f 5500-1316 1317 1320 1391 UV2B Sampler Column 65 0.3f 5500- UV3 Column VWD/ 65 0.3f 5500- - UV4 VWD/ DC Box/ PRV 55 0.3f 5500-1408 1386 0.7r 5500-1389 1395 UV5 VWD/ PRV 65 0.3f 5500-1308 1309 1318 1390 Table 14 Preparative Fraction Collector tubing kits (G1364E) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Fraction Collector tubing kit G1364-68603 G1364-68604 G1364-68605 Coent 4 8 ml/min 15 100 ml/min 20

21

Configuration with Preparative Fraction Collector and Delay Coil Organizer (G9324) Table 15 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV 5067-6858 5067-6859 5067-6860 5067-6809 1 kit for each flow rate Flow range 4 8mL/min 15 80 ml/min 80 From To Length /cm Fittings UV1 Pump Sampler 65 0.3f 5500-1308 1309 1318 1390 UV2A Sampler Column 50 0.3f 5500-1316 1317 1320 1391 UV2B Sampler Column 65 0.3f 5500- UV3 Column VWD/ 65 0.3f 5500- - UV4 VWD/ DC Box/ PRV 55 0.3f 5500-1408 1386 0.7r 5500-1389 1395 UV5 VWD/ PRV 65 0.3f 5500-1308 1309 1318 1390 Table 16 Preparative Fraction Collector tubing kits (G1364E) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Fraction Collector tubing kit G1364-68603 G1364-68604 G1364-68605 Coent 4 8 ml/min 15 100 ml/min 22

23

Standard Mass-Based Systems Configuration Table 17 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV 5067-6858 5067-6859 5067-6860 5067-6809 1 kit for each flow rate Flow range 4 8mL/min 15 80 ml/min 80 From To Length /cm Fittings UV1 Pump Sampler 65 0.3f 5500-1308 1309 1318 1390 UV2A Sampler Column 50 0.3f 5500-1316 1317 1320 1391 UV2B Sampler Column 65 0.3f 5500- UV3 Column VWD/ 65 0.3f 5500- - UV4 VWD/ DC Box/ PRV 55 0.3f 5500-1408 1386 0.7r 5500-1389 1395 UV5 VWD/ PRV 65 0.3f 5500-1308 1309 1318 1390 24

Table 18 Upgrade Capillary kit MS-Based Prep LC Upgrade Capillary kit MS-Based Prep LC No. 5067-6861 1 kit 4 8mL/min 15 80 ml/min 80 1 kit only From To Length /cm ID / No. ID / No. ID / No. ID / No. Fittings MS1B Column Flow modul. 90 0.3r 5500-1321 0.5r 5500-1322 1323 1403 - MS2 Flow modul. VWD/ 55 0.3f 5500-1397 1400 1402 1405 - MS3 Make up Flow modul. 120 0.12 5500-1398 FLOW INDEPENDENT CAPILLARIES MS4 Flow modul. MS 120 0.12 5500-1398 MS5 MS restriction capillary 7 0.12 5500-1329 MS6 MS waste capillary 70 0.25 5500-1330 NON Table 19 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G9321-60953) Tubing Kit 50 (G9321-60952) Tubing Kit 150 (G9321-60954) Tubing Kit 200 (G9321-60951) Suitable for the flow up to 1 8 ml/min 15 50 ml/min 50 150 ml/min 150 25

Table 20 Preparative Fraction Collector tubing kits (G1364E) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Fraction Collector tubing kit G1364-68603 G1364-68604 G1364-68605 Coent 4 8 ml/min 15 100 ml/min Length/cm No. Fittings FM1 8 0.25 5067-6820 - FM2 10 0.12 5067-6821 26

27

Configurations with 1290 Infinity II Preparative Column Compartment (G7163B) Entry Level System Configurations (with Manual Injector) Entry Level System Configuration Table 21 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV 5067-6858 5067-6859 5067-6860 5067-6809 1 kit for each flow rate Flow range 4 8mL/min 15 80 ml/min 80 From To Length /cm Fittings UV1 Pump Sampler 65 0.3f 5500-1308 1309 1318 1390 UV2A Sampler Column 50 0.3f 5500-1316 1317 1320 1391 UV2B Sampler Column 65 0.3f 5500- UV2C Sampler Column 80 0.3f 5500-1406 1384 1387 1392 UV2D Sampler Column 100 0.3f 5500-1407 1385 1388 1394 UV3 Column VWD/ 65 0.3f 5500- - UV4 VWD/ DC Box/ PRV 55 0.3f 5500-1408 1386 0.7r 5500-1389 1395 28

Table 22 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G9321-60953) Tubing Kit 50 (G9321-60952) Tubing Kit 150 (G9321-60954) Tubing Kit 200 (G9321-60951) Suitable for the flow up to 1 8 ml/min 15 50 ml/min 50 150 ml/min 150 Table 23 Preparative Fraction Collector tubing kits (G1364E) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Fraction Collector tubing kit G1364-68603 G1364-68604 G1364-68605 Coent 4 8 ml/min 15 100 ml/min 29

30

Entry Level System Configuration with Delay Coil Organizer (G9324A) Table 24 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV 5067-6858 5067-6859 5067-6860 5067-6809 1 kit for each flow rate Flow range 4 8mL/min 15 80 ml/min 80 From To Length /cm Fittings UV1 Pump Sampler 65 0.3f 5500-1308 1309 1318 1390 UV2A Sampler Column 50 0.3f 5500-1316 1317 1320 1391 UV2B Sampler Column 65 0.3f 5500- UV2C Sampler Column 80 0.3f 5500-1406 1384 1387 1392 UV2D Sampler Column 100 0.3f 5500-1407 1385 1388 1394 UV3 Column VWD/ 65 0.3f 5500- - UV4 VWD/ DC Box/ PRV 55 0.3f 5500-1408 1386 0.7r 5500-1389 1395 Table 25 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G9321-60953) Tubing Kit 50 (G9321-60952) Tubing Kit 150 (G9321-60954) Tubing Kit 200 (G9321-60951) Suitable for the flow up to 1 8 ml/min 15 50 ml/min 50 150 ml/min 150 31

Table 26 Preparative Fraction Collector tubing kits (G1364E) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Fraction Collector tubing kit G1364-68603 G1364-68604 G1364-68605 Coent 4 8 ml/min 15 100 ml/min 32

33

Standard UV/LC System Configurations Standard UV/LC System Configurations Table 27 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV 5067-6858 5067-6859 5067-6860 5067-6809 1 kit for each flow rate Flow range 4 8mL/min 15 80 ml/min 80 From To Length /cm Fittings UV1 Pump Sampler 65 0.3f 5500-1308 1309 1318 1390 UV2A Sampler Column 50 0.3f 5500-1316 1317 1320 1391 UV2B Sampler Column 65 0.3f 5500- UV2C Sampler Column 80 0.3f 5500-1406 1384 1387 1392 UV2D Sampler Column 100 0.3f 5500-1407 1385 1388 1394 UV3 Column VWD/ 65 0.3f 5500- - UV4 VWD/ DC Box/ PRV 55 0.3f 5500-1408 1386 0.7r 5500-1389 1395 34

Table 28 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G9321-60953) Tubing Kit 50 (G9321-60952) Tubing Kit 150 (G9321-60954) Tubing Kit 200 (G9321-60951) Suitable for the flow up to 1 8 ml/min 15 50 ml/min 50 150 ml/min 150 Table 29 Preparative Fraction Collector tubing kits (G1364E) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Fraction Collector tubing kit G1364-68603 G1364-68604 G1364-68605 Coent 4 8 ml/min 15 100 ml/min 35

36

Standard UV/LC System Configurations with Delay Coil Organizer (G9328A) Table 30 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV 5067-6858 5067-6859 5067-6860 5067-6809 1 kit for each flow rate Flow range 4 8mL/min 15 80 ml/min 80 From To Length /cm Fittings UV1 Pump Sampler 65 0.3f 5500-1308 1309 1318 1390 UV2A Sampler Column 50 0.3f 5500-1316 1317 1320 1391 UV2B Sampler Column 65 0.3f 5500- UV2C Sampler Column 80 0.3f 5500-1406 1384 1387 1392 UV2D Sampler Column 100 0.3f 5500-1407 1385 1388 1394 UV3 Column VWD/ 65 0.3f 5500- - UV4 VWD/ DC Box/ PRV 55 0.3f 5500-1408 1386 0.7r 5500-1389 1395 Table 31 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G9321-60953) Tubing Kit 50 (G9321-60952) Tubing Kit 150 (G9321-60954) Tubing Kit 200 (G9321-60951) Suitable for the flow up to 1 8 ml/min 15 50 ml/min 50 150 ml/min 150 37

Table 32 Preparative Fraction Collector tubing kits (G1364E) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Fraction Collector tubing kit G1364-68603 G1364-68604 G1364-68605 Coent 4 8 ml/min 15 100 ml/min 38

39

Standard Mass-Based System Configurations Table 33 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV 5067-6858 5067-6859 5067-6860 5067-6809 1 kit for each flow rate Flow range 4 8mL/min 15 80 ml/min 80 From To Length /cm Fittings UV1 Pump Sampler 65 0.3f 5500-1308 1309 1318 1390 UV2A Sampler Column 50 0.3f 5500-1316 1317 1320 1391 UV2B Sampler Column 65 0.3f 5500- UV2C Sampler Column 80 0.3f 5500-1406 1384 1387 1392 UV2D Sampler Column 100 0.3f 5500-1407 1385 1388 1394 UV3 Column VWD/ 65 0.3f 5500- - UV4 VWD/ DC Box/ PRV 55 0.3f 5500-1408 1386 0.7r 5500-1389 1395 40

Table 34 Upgrade Capillary kit MS-Based Prep LC Upgrade Capillary kit MS-Based Prep LC No. 5067-6861 1 kit 4 8mL/min 15 80 ml/min 80 1 kit only From To Length /cm ID / No. ID / No. ID / No. ID / No. Fittings MS1A Column Flow modul. 50 0.3f 5500-1396 1399 1401 1404 - MS2 Flow modul. VWD/ 55 0.3f 5500-1397 1400 1402 1405 - MS3 Make up Flow modul. 120 0.12 5500-1398 FLOW INDEPENDENT CAPILLARIES MS4 Flow modul. MS 120 0.12 5500-1398 MS5 MS restriction capillary 7 0.12 5500-1329 MS6 MS waste capillary 70 0.25 5500-1330 NON Table 35 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G9321-60953) Tubing Kit 50 (G9321-60952) Tubing Kit 150 (G9321-60954) Tubing Kit 200 (G9321-60951) Suitable for the flow up to 1 8 ml/min 15 50 ml/min 50 150 ml/min 150 41

Table 36 Preparative Fraction Collector tubing kits (G1364E) P/N 5067-6858 5067-6859 5067-6860 5067-6809 Preparative Fraction Collector tubing kit G1364-68603 G1364-68604 G1364-68605 Coent 4 8 ml/min 15 100 ml/min Length/cm No. Fittings FM1 8 0.25 5067-6820 - FM2 10 0.12 5067-6821 42

43

Accessories UV Accessories Table 37 Accessories for kits 5067-6858, 5067-6859, 5067-6860, 5067-6809 A-Line Quick Turn LC Fitting for Column 2 pcs for kits 5067-6858 and 5067-6859 5067-5966 UHP-FF FITTING for Column 2 pcs for kits 5067-6860 and 5067-6809 5067-5403 3m Tube ESD PTFE OD2.5 ID1.6 5023-3086 ESD-Fitting OD-2.5 5023-2871 Union Flat-Bottom 1/4-28 ESD 5023-2508 Plastic and PEEK tubing cutter 8710-1930 Fitting-Handle 5043-1471 Sealtight-Handle 5043-0915 MS Accessories Table 38 Accessories 3 m Tube ESD PTFE OD 2.5 ID 1.6 5023-3086 ESD-Fitting OD-2.5 5023-2871 Fitting adapter 10-32 to 1-4-28 SST 5023-2875 TEE-LOW DEAD VOLUME 0100-1818 Fitting-Handle 5043-1471 Sealtight-Handle 5043-0915 NOTE The flow modulator bypass is part of the G7170-68705 Flow Modulator Accessory Kit. *G7161-90201* *G7161-90201* G7161-90201 Number: G7161-90201 Edition: 11/2017 Printed in Germany Agilent Technologies, Inc 2017 Agilent Technologies, Inc Hewlett-Packard-Strasse 8 76337 Waldbronn, Germany