Effect of different exposure settings on the diagnosis of vertical root fractures on cone-beam computed tomography images

Similar documents
Mehran Taramsari 1, Zahra Dalili Kajan 2, *, Parinaz Bashirzadeh 3, Fatemeh Salamat 4. Introduction ABSTRACT

Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study

Comparison of conventional radiography with cone beam computed tomography for detection of vertical root fractures: an in vitro study

Journal of Dental School 2014; 32(1): 23-29

Accuracy of CBCT as modality to identify the presence of secondary mesiobuccal root canal in the maxillary first molar

A comparative study of cone-beam computed tomography and digital periapical radiography in detecting mandibular molars root perforations

The effect of metal artifacts on the identification of vertical root fractures using different fields of view in cone-beam computed tomography

Value of cone beam CT in detection of dental root fractures

Sang-Sun Han, 1 Kwang-Min Lee, 2 and Kee-Deog Kim Introduction

Staining Potential of Calcium Hydroxide and Monochlorophenol Following Removal of AH26 Root Canal Sealer

Accuracy of Conventional and Digital Radiography in Detecting External Root Resorption

Peking University School and Hospital of Stomatology. c Professor, Department of Cariology, Endodontology, and Operative

Detection of horizontal root fracture using four different protocols of cone-beam computed tomography

Periapical radiography and cone beam computed tomography for assessment of the periapical bone defect 1 week and 12 months after root-end resection

Evaluation of Cone Beam Computed Tomography in Diagnosis and Treatment Plan of Impacted Maxillary Canines

ENDODONTICS: Colleagues for Excellence. aae.org/colleagues. Spring Published for the Dental Professional Community by the

Diagnostic accuracy of conventional radiography and digital radiography in detecting of root fractures (invitro study)

Effect of Metal Artifacts on Detection of Vertical Root Fractures Using Two Cone-Beam Computed Tomography Systems

The Graduate School Yonsei University Department of Dentistry Myoungah Seo

Case Report Endodontic Treatment of Bilateral Maxillary First Premolars with Three Roots Using CBCT: A Case Report

Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption

Monday Morning Pearls of Practice by Bobby Baig

Original Research Article

Case Report Root Canal Treatment of Mandibular Second Premolar with Three Separate Roots and Canals Using Spiral Computed Tomographic

CBCT Specific Guidelines for South African Practice as Indicated by Current Literature:

International Journal of Basic and Clinical Studies (IJBCS) 2014;3(1): Uysal I and Oztekin F

Low Dose Excellent Image Quality Rapid Reconstruction

International Journal of Current Medical and Pharmaceutical Research

Diagnostic accuracy of conventional, digital and Cone Beam CT in vertical root fracture detection

Evaluation of a Digital Measurement Tool to Estimate Working Length in Endodontics

WaveOne Gold reciprocating instruments: clinical application in the private practice: Part 2

Diagnostic Accuracy of Cone-Beam Computed Tomography and Periapical Radiography in Internal Root Resorption

Effect of Developer Age and Film Speed on Diagnostic Accuracy of Endodontic File Length Measurement on Radiographs

Comparison of panoramic radiography with cone beam CT in predicting the relationship of the mandibular third molar roots to the alveolar canal

An unusual maxillary canine with two separated root canals

Reliability of Orthopantomography and Cone-beam Computed Tomography in Presurgical Implant Planning: A Clinical Study

Evidence-based decision-making in endodontics

Assessment of the relationship between the maxillary molars and adjacent structures using cone beam computed tomography

Head to new heights with your imaging SCANORA 3D

Comparative evaluation of pulpal vitality test accuracy in different groups of teeth

Vertical root fractures (VRFs) are difficult to diagnose by conventional periapical

Case Report Endodontic Management of Maxillary Second Molar with Two Palatal Roots: A Report of Two Cases

KING SAUD UNIVERSITY College of Dentistry. Department of Restorative Dental Sciences DIVISION OF ENDODONTICS COURSE OUTLINE 323 RDS

The Effect of X Ray Vertical Angulation on Radiographic Assessment of Alveolar Bone Loss

Limited To Endodontics Newsletter. Limited To Endodontics A Practice Of Endodontic Specialists June Volume 4

EVALUATION OF ROOT ANATOMY AND MORPHOLOGY OF MANDIBULAR PREMOLARS WITH CBCT IN IRANIAN POPULATION ABSTRACT

ANALYSIS OF FRACTURED TEETH UTILIZING DIGITAL MICROSCOPY: A PILOT STUDY

Journal of Craniomaxillofacial Research. Vol. 3, No. 4 Autumn 2016

Comparison of Periapical Radiography and Limited Cone-Beam Tomography in Posterior Maxillary Teeth Referred for Apical Surgery

Interpretation Basics of Cone Beam Computed Tomography COPYRIGHTED MATERIAL

Technical quality of root canal treatment performed by undergraduate dental students

Detection accuracy of root fractures in cone-beam computed tomography images: a systematic review and meta-analysis

Endodontic Treatment of a Mandibular First Premolar With Three Root Canals: A Case Report

Dimensional stability in composite cone beam computed tomography

Evaluation of enamel pearls by cone-beam computed tomography (CBCT)

Large periapical lesion: Healing without knife and incision

Comparison of intraoral radiography and limited cone beam computed tomography for the assessment of root-fractured permanent teeth

Radiographic Evaluation of Bone Formation and Density Changes after Mandibular Third Molar Extraction: A 6 Month Follow up

Cone Beam Computed Tomography in Endodontics: An Overview.

SEDENTEXCT: Guidelines and evidence-based use of CBCT

CBCT Evaluation Of Glidepath Preparation By Different Rotary Nickel Titanium Glide Path...

UNDERSTANDING DIGITAL DENTISTRY: CBCT AND INTRA-ORAL 30 SCANNING

ENDODONTIC MANAGEMENT OF C-SHAPED CANAL IN MANDIBULAR SECOND MOLAR: A CASE REPORT

3D Accuitomo XYZ Slice View Tomograph. Super High-Resolution Images of Region of Interest

Horizontal root fracture (HRF) implies a severe injury to cementum, dentin, and pulp

Accuracy of chemically created periapical lesion measurements using limited cone beam computed tomography

MAXILLARY FIRST MOLAR : AN ENIGMA FOR ENDODONTISTS

Case Report Endodontic Management of a Maxillary First Molar with Two Palatal Canals and a Single Buccal Canal: A Case Report

The outcome of root-canal treatments assessed by cone-beam computed tomography Liang, Y.H.

Effect of Amperage and Field of View on Detection of Vertical Root Fracture in Teeth with Intracanal Posts

Three-dimensional analysis of impacted maxillary third molars: A cone-beam computed tomographic study of the position and depth of impaction

Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries

Assessment of Response of Dental Clinicians and Patients towards Different Imaging Modalities Used In Diagnostic Evaluation of Dental Implant Therapy.

Diagnosis and treatment of teeth with primary endodontic lesions mimicking periodontal disease: three cases with long-term follow ups

Application of augmented reality for inferior alveolar nerve block anesthesia: A technical note

ENDODONTOLOGY ABSTRACT INTRODUCTION

Limited cone-beam CT and intraoral radiography for the diagnosis of periapical pathology

Efficacy of the Edge Enhancement Filter of Digital Radiography in the Detection of Proximal Enamel Caries in Premolars

Common Intra Oral Radiographic Errors Made by Dental Students

Comparison of treatment planning decisions when combining CBCT and digital radiography verses digital radiography alone

Assessment of bifid and trifid mandibular canals using cone-beam computed tomography

Investigating the Sizes of Anatomical Landmarks of Coronal Pulp in the First Permanent Human Molars on Bite Wing Radiography

Endodontic management of radix entomolaris: Case reports

Cone-Beam Computed Tomography as a Tool in Endodontic Detection and Diagnosis

Non-surgical endodontic treatment f invaginatus type III using cone bea Title tomography and dental operating mic report.

Mid Mesial Canal in Mandibular Molars: Two Case Report and A Review of Literature

Nestor Cohenca Professor Department of Endodontics Department of Pediatric Dentistry Diplomate, ABE

Endodontic management of a mandibular second molar with radix entomolaris: a case report

Efficacy of Pseudocolor Tool of Digital System in the Detection of Proximal Caries

Clinical details: Details of scan: CONE BEAM CT REPORT: Name: H. B. Gender: Reason for referral: Referred by:

Unusual transmigration of canines report of two cases in a family

NOVEL METHODS FOR THE ASSESSMENT OF CRACK PROPAGATION IN ENDODONTICALLY TREATED TEETH

Cone Beam 3D Imaging

The cracked tooth Diagnosis and evaluation

Pulp volume estimation using CBCT- an in vitro pilot study on extracted monoradicular teeth

Two- and Three-dimensional Orthodontic Imaging Using Limited Cone Beam Computed Tomography

Digital Imaging from a new perspective

Evaluation of technical quality and periapical

Veraviewepocs 3D R100 & F40

In vitro evaluation of root canal preparation with plastic endodontic rotary finishing file - A SEM study

Transcription:

Medical Communication Biosci. Biotech. Res. Comm. 11(1): 117-121 (2018) Effect of different exposure settings on the diagnosis of vertical root fractures on cone-beam computed tomography images Sandra Mehralizadeh*, Zohreh Khalilak and Sepideh Entezari ABSTRACT By considering the importance of vertical root fractures (VRF) and the known complications of incorrect diagnoses, the present study aimed to evaluate the effect of different kilovoltage peak (kvp) and milliampere (ma) settings in conebeam computed tomography (CBCT) on the diagnosis of VRFs in endodontically treated single-canal premolars. Eighty intact human premolars were endodontically treated and coded. The roots of half of the samples were fractured, and were taken by using four different combinations of maximum (max) and minimum (min) kvp (60-86) and ma (6-10) settings under the same conditions. The images were randomly observed twice by an experienced oral and maxillofacial radiologist over a two-week interval. The results were analyzed by Chi-square test. In the kvp max/ma max group, none of the images were diagnostic. In the kvp max/ma min group, 62 images (77.5%) were nondiagnostic. The results of these two groups showed significant statistical differences with the other two groups (P<0.001). Incorrect diagnoses were equal to 22.5% in the kvp min/ma min group, and 16.2% in the kvp min/ma max group with no significant statistical differences (P<0.4). It seems that the best view for identifying VRFs on in axial sections can be obtained with kvp min/ma max setting. It can be concluded that kvp min/ma max and kvp min/ma min settings are suitable for the diagnosis of VRFs. Also, a lower kvp renders a lower patient radiation dose. KEY WORDS: CONE-BEAM COMPUTED TOMOGRAPHY, TOOTH FRACTURES, DIAGNOSTIC IMAGING ARTICLE INFORMATION: *Corresponding Author: Sandramehr@yahoo.com Received 2 nd Jan, 2018 Accepted after revision 21 st March, 2018 BBRC Print ISSN: 0974-6455 Online ISSN: 2321-4007 Thomson Reuters ISI ESC / Clarivate Analytics USA and Crossref Indexed Journal NAAS Journal Score 2017: 4.38 SJIF 2017: 4.196 A Society of Science and Nature Publication, Bhopal India 2018. All rights reserved. Online Contents Available at: http//www.bbrc.in/ DOI: 10.21786/bbrc/11.1/16 117

INTRODUCTION Vertical and horizontal root fractures (VRF/HRF) have always been regarded as diagnostic predicaments since they are difficult to detect on intraoral radiographs. Conventional and digital intraoral radiographic techniques are the most common methods for detecting root fractures. These fractures can also be assessed by routine dental examinations (Özer, 2011; Edlund et al. 2011). Endodontic therapy is one of the major causes of root fractures (Taramsari et al. 2013; Uzun et al. 2015). VRFs are more prevalent in the patients over the age of 40 years and in maxillary and mandibular premolars and in the mesial roots of mandibular molars. In molars, VRFs usually occur in a buccolingual direction in separate roots, while mesiodistal fractures are less common. In anterior teeth, the fracture usually extends in a buccolingual direction (Li et al. 2002). The most common radiographic findings in root fractures include an increased thickness of the periodontal ligament (PDL), a deep local or vertical bone loss, and peri-radicular bone loss (Shi et al. 2009). Root fractures have become diagnosable since 1896 when twodimensional (2D) radiography was introduced to dentistry (Li et al. 2002). However, if the angle of the projection is not perpendicular to the fracture line, these fractures may remain undiagnosed (Salineiro et al. 2015). For a more accurate diagnosis, the conventional 2D radiography can be completed with a third dimension. Cone-beam computed tomography (CBCT) was introduced in 1998 for dento alveolar imaging (da Silveira et al. 2013). Many studies have proven the efficacy of this system in the detection and diagnosis of root fractures (Taramsari et al. 2013). The old techniques used for the diagnosis of VRFs are unreliable due to the presence of nonspecific signs and symptoms which lead to unnecessary tooth extractions. Moreover, VRFs may extend from the internal part of the root in buccal, lingual, apical, or cervical directions. In these cases, the induced inflammation will lead to bone loss and may create a radiographic view similar to that of periodontal diseases. Therefore, an accurate diagnosis of VRFs prevents the erroneous extraction of treatable teeth (Taramsari et al. 2013; Chang et al. 2016). The X-rays projected from CBCT units are influenced by different factors such as the voxel size, field of view (FOV), degree of rotation, condition of the tube, and voltage, which can change the image quality, and therefore, should be selected carefully in different diagnostic cases (Jones et al. 2015; Neves et al. 2014; Kamburoğlu et al. 2013). In 2015, Jones et al assessed the range of eleven different CBCT parameters in the diagnosis of HRFs. The effect of these factors on the diagnosis of VRFs is still a matter of debate as the studies on the diagnosis of VRFs with the use of CBCT have focused on the effect of root filling materials (Taramsari et al. 2013; Neves et al. 2014), different image modes such as resolution, zoom, speed, or different voxel sizes (Taramsari et al. 2013; Neves et al. 2014, Uzun et al. 2015; Chang et al. 2016). Therefore, an information gap is observed among these studies. The present study was performed to assess the effect of different kilovoltage peak (kvp) and milliampere (ma) settings of a CBCT unit on the detection of VRFs in endodontically treated single-canal premolars at the dental branch of Islamic Azad University, Tehran, Iran during 2015-16. The null hypothesis was that the changes in the kvp and ma of CBCT units have no effect on the detection of VRFs. MATERIAL AND METHODS In this in-vitro diagnostic study, 80 extracted singlecanal human premolars without any cracks or fractures were selected by using target-based sampling method. The surfaces of the teeth were cleaned of debris and tissue remnants. Root canal treatments: Access cavities were prepared in all the teeth. A #20 K-file (Dentsply Maillefer, Ballaigues, Switzerland) was selected as the initial file. A #35 K-file (Dentsply Maillefer, Ballaigues, Switzerland) was selected as the master apical file (MAF). The root canals were widened to the #60 K-file (Dentsply Maillefer, Ballaigues, Switzerland) via step back technique. All the root canals were obturated by using #35 gutta-percha points (Dia- Dent, Burnaby, BC, Canada) and AH26 endodontic sealer (Dentsply DeTrey, Konstanz, Germany). Formation of VRFs in the dental roots: In the roots of half of the teeth, a VRF was created by exerting a mechanical force by using a dental plugger, while the other half were left intact. For ensuring the presence of fractures, the teeth were stained with methylene blue dye, and then, they were coded. Also, the fracture site was covered with red wax. Afterwards, the teeth were kept in physiologic serum until the experiment. Placing the teeth in dental sockets: The coded teeth were covered with a layer of red wax to compensate for the thickness of the PDL, and then, they were placed in the dental sockets of a dried human mandible. The longitudinal axes of the teeth were positioned perpendicular to the horizon. CBCT imaging: were taken of all the teeth by the use of the Rotograph Evo 3D Machine (Villa Sistemi Medicali, Milan, Italy) with four different combinations of maximum (max) and minimum (min) kvp (60-86) and ma (6-10) settings under similar conditions in terms of the distance, resolution, etc. 118 EFFECT OF DIFFERENT EXPOSURE SETTINGS ON THE DIAGNOSIS OF VERTICAL ROOT FRACTURES BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS

First group: kvp min(60)/ma min(6) Second group: kvp max(86)/ma min(6) Third group: kvp min(60)/ma max(10) Fourth group: kvp max(86)/ma max(10) Image observation: The were saved and assessed by using the OnDemand3D software program (version 1.0, Cybermed Inc., Seoul, Korea). All the images (a total of 320 images in the four groups) were randomly put in the Viewer file such that the observer was unaware of the order and distribution of the images. The observer was an oral and maxillofacial radiologist experienced in interpreting. A dental root was considered vertically fractured when a vertical radiolucent line was detected on both axial and coronal views. The results were entered in a data sheet. After two weeks, the observer reevaluated the images, and the results were registered in separate data sheets. Statistical analysis: The cases of correct diagnoses (true positive (TP) + true negative (TN)), incorrect diagnoses (false positive (FP) + false negative (FN)), and nondiagnostic cases were determined. The data were entered into SPSS version 21 software program (IBM Co., Chicago, IL, USA) and were analyzed according to Chi-square test. RESULTS AND DISCUSSION This study was performed on 80 endodontically treated, single-canal mandibular premolars divided into two groups (40 teeth with and 40 teeth without VRFs), and the images were obtained by using four different combinations of ma min, ma max, kvp min, and kvp max exposure settings.the distribution of the dental specimens according to ma=6 are presented in Table 1 categorized in two columns of the real fractures and the fractures observed on. The images of 62 dental samples (38.7%) which had been exposed with ma=6 did not have the required quality for observation and detection of fractures and were excluded from the study. This table shows that the numbers of the correct diagnoses including the positive and negative cases were equal to 72 cases (73.4%), while the numbers of the Table 1. Distribution of the evaluated teeth according to the real fractures and the fractures observed on (ma=6) No 46 22 58 Yes 4 26 30 Total 50 48 98 Table 2. Distribution of the evaluated teeth according to the real fractures and the fractures observed on (ma=10) No 38 11 49 Yes 2 29 31 Total 40 40 80 incorrect diagnoses including the positive and negative cases were equal to 26 cases (26%). to ma=10 are presented in Table 2 categorized in two on. Images of 80 dental specimens (50%) which had been exposed with ma=10 were nondiagnostic and were excluded. This table shows that the numbers of the correct diagnoses including the positive and negative cases were equal to 67 cases (83.5%), while the numbers of the incorrect diagnoses were equal to 13 cases (16%). to kvp=86 are presented in Table 3 categorized in two on. Images of 142 dental samples (88.7%) which had been exposed with kvp=86 did not have a suitable quality for the detection of fractures and were excluded. This table shows that the numbers of the correct diagnoses including the positive and negative cases were equal to 18 cases (100%) with no incorrect diagnoses. to kvp=60 are presented in Table 4 categorized in two on. Images of 160 dental specimens (100%) which had been exposed with kvp=60 were nondiagnostic and were excluded. This table shows that the numbers of the correct diagnoses including the positive and negative cases were equal to 129 cases (80.6%), while the numbers of the incorrect diagnoses were equal to 31 cases (19%). Table 3. Distribution of the evaluated teeth according to the real fractures and the fractures observed on (kvp=86) No 10-10 Yes - 8 8 Total 10 8 18 BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS EFFECT OF DIFFERENT EXPOSURE SETTINGS ON THE DIAGNOSIS OF VERTICAL ROOT FRACTURES 119

Table 4. Distribution of the evaluated teeth according to the real fractures and the fractures observed on (kvp=60) No 74 25 99 Yes 6 55 61 Total 80 80 160 The distribution of the samples according to the correct and incorrect diagnoses categorized by the exposure settings is presented in Table 5 which shows that when the kvp max/ma max setting was used, none of the images were diagnostic, and when the kvp max/ma min setting was used, 62 images (77.5%) were nondiagnostic. In terms of the diagnostic ability, these two exposure settings showed significant statistical differences with the other two settings (P<0.001). When the kvp min/ma min setting was used, incorrect diagnoses (FP + FN) were made with regard to 18 images (22.5%), while when the kvp min/ma max setting was used, incorrect diagnoses (FP + FN) were made on 13 images (16.2%); Chi-square test showed no significant differences between these two exposure settings (P<0.4). The present study showed that in the ma min(6)/ kvp min(60) group, the observer was able to make correct diagnoses in 62 cases (77.5%), while in 18 cases (22.5%), the diagnoses were incorrect. In the ma min(6)/ kvp max(86) group, the observer was able to make correct diagnoses in 18 cases (22.5%), while no incorrect diagnoses were made in this group, and also, 62 images (77.5%) were nondiagnostic. In the ma max(10)/kvp min(60) group, the observer made correct diagnoses in 67 cases (83.7%), while the diagnoses were incorrect in 13 cases (16.2%). In the ma max(10)/kvp max(86) group, the observer was unable to make a diagnosis with regard to any of the cases, and all the 80 images were nondiagnostic. Therefore, the kvp max/ma max and ma min/kvp max showed significant differences with the other two exposure settings (P<0.001), while the ma max/kvp min and ma min/kvp min exposure settings showed no significant statistical differences according to Chi-square test (P<0.4). Therefore, it seems that in the diagnosis of VRFs in endodontically treated teeth on, the changes in the kvp are more effective than the changes in the ma since the diagnoses have been more realistic with the kvp min/ma max exposure setting. In 2015, Jones et al evaluated the effect of different exposure parameters of CBCT units on the detection of simulated HRFs. The kvp was set at 90 kv, while the size of the FOV and scan speed were constant, focusing only on the ma changes. Also, two different exposure times were used. The results showed that the highest levels of sensitivity and specificity were calculated when ma max was used. Also, the highest level of positive predictive value (PPV) and negative predictive value (NPV) was achieved in the cited study at ma max with an acceptable significance level. The results of the present study are similar to those of the cited study with regards to the effect of the ma and maintaining the ma max to achieve the best image quality, although, in the abovementioned study (Jones et al. 2015), the kvp remained fixed. The present study showed that keeping the kvp at the minimum possible level with a fixed ma results in the best image quality. Pauwels et al (2015) evaluated the improvement in the quality of after reducing the ma. The results demonstrated that at low levels of ma and at ma min, the image quality degrades due to increased radiographic noise and the consequent increase in the contrast-to-noise ratio (CNR). Therefore, the cited study is in line with ours in terms of confirming a better image quality when using higher ma settings. In a study by Palomo et al, a reduced kvp and a fixed ma were used to decrease the patient dose. They demonstrated that by Table 5. Distribution of the evaluated samples according to the correct and incorrect diagnoses categorized by the studied groups Definite diagnosis TP+TN (%) FP+FN (%) Nondiagnostic (%) Total (%) ma min/kvp min 62(77.5) 18 (22.5) 0(0) 80(100) ma min/kvp max 18(22.5) 0 (0) 62(77.5) 80(100) ma max/kvp min 67(83.7) 13(16.2) 0(0) 80(100) ma max/kvp max 0(0) 0(0) 80(100) 80(100) TP+TN=true positive + true negative, FP+FN=false positive + false negative 120 EFFECT OF DIFFERENT EXPOSURE SETTINGS ON THE DIAGNOSIS OF VERTICAL ROOT FRACTURES BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS

a decrease in the kvp and changing the other exposure parameters, high-quality images can be obtained at a reduced patient dose. Therefore, the results of the mentioned study are in agreement with ours in terms of the use of kvp min settings to reduce the patient dose. Kim et al (2010) compared different exposure settings of different CBCT units and concluded that to achieve the best image quality, the ma can be increased up to 10 times with a constant kvp. It seems that the overall results of the cited study are in agreement with ours. The results of the study by Neves et al in 2014 on the evaluation of the effect of different CBCT imaging parameters on the diagnosis of HRFs with different obturation materials showed that parameters such as the resolution and obturation materials in endodontic therapy are more important; however, they limitedly investigated the effect of the ma and kvp. Therefore, although their results are not directly comparable to ours, they are indicative of the importance of factors such as the resolution. In our study, the changes in the ma and kvp directly influenced the image resolution. Although in the diagnosis of root fractures, which is among the most difficult diagnoses in dental imaging, CBCT can be used with the minimum patient radiation dose in comparison with other imaging modalities such as medical CT, by considering the as low as reasonably achievable (ALARA) principle, even in such cases, it is attempted to deliver a minimum radiation dose to the patient. In the present study, we adhered to the ALARA principle by minimizing the kvp and maximizing the ma to achieve high-quality images with the best resolution and the minimum patient radiation dose. The in-vitro design of the present study was a limitation since due to the presence of the PDL around natural teeth in vivo, they may show a different behavior than those under laboratory conditions. The positive points of the present study included its novelty, the simultaneous analysis of two exposure parameters, and a large sample size. Since the X-rays projected from CBCT units are influenced by factors such as the voxel size, FOV, degree of rotation, and tube status, which can influence image quality, future studies to assess the effect of these parameters on the detection of VRFs are recommended for the accurate and definite diagnosis of this type of root fracture. CONCLUSION The results of the present study showed that the best views for the detection of simulated VRFs on CBCT images in axial views are achieved with the ma max/ kvp min exposure setting. Also, the patient radiation dose can be reduced by minimizing the kvp. REFERENCES Chang E, Lam E, Shah P, Azarpazhooh A. (2016): Cone-beam computed tomography for detecting vertical root fractures in endodontically treated teeth: a systematic review. J Endod. 42:177-85 Da Silveira PF, Vizzotto MB, Liedke GS, da Silveira HL, Montagner F, da Silveira HE. (2013): Detection of vertical root fractures by conventional radiographic examination and cone beam computed tomography - an in vitro analysis. Dent Traumatol. 29:41-6. Edlund M, Nair MK, Nair UP. (2011): Detection of vertical root fractures by using cone-beam computed tomography: a clinical study. J Endod. 37:768-72. Jones D, Mannocci F, Andiappan M, Brown J, Patel S. (2015): The effect of alteration of the exposure parameters of a conebeam computed tomographic scan on the diagnosis of simulated horizontal root fractures. J Endod. 41:520-5. Li G, Yoshiura K, Welander U, Shi XQ, McDavid WD. (2002): Detection of approximal caries in digital radiographs before and after correction for attenuation and visual response. An in vitro study. Dentomaxillofac Radiol. 31:113-6. Kim S, Yoo S, Yin FF, Samei E, Yoshizumi T. (2010): Kilovoltage cone beam CT: comparative dose and image quality evaluations in partial and full angle scan protocols. Med Phys. 37:3648-59. Neves FS, Freitas DQ, Campos PS, Ekestubbe A, Lofthag-Hansen S. (2014): Evaluation of cone-beam computed tomography in the diagnosis of vertical root fractures: the influence of imaging modes and root canal materials. J Endod. 40:1530-6. Özer SY. (2011): Detection of vertical root fractures by using cone beam computed tomography with variable voxel sizes in an in vitro model. J Endod. 37:75-9. Palomo JM, Rao PS, Hans MG. (2008): Influence of CBCT exposure conditions on radiation dose. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 105:773-82. Pauwels R, Seynaeve L, Henriques JC, de Oliveira-Santos C, Souza PC, Westphalen FH, et al. (2015): Optimization of dental CBCT exposures through mas reduction. Dentomaxillofac Radiol. 44:20150108. Salineiro FC, Pinheiro LR, dos Santos Júnior O, Cavalcanti MG. (2015): Detection of horizontal root fracture using four different protocols of cone-beam computed tomography. Braz Oral Res. 29. pii: S1806-83242015000100264 Shi XQ, Li G. (2009): Detection accuracy of approximal caries by black-and-white and color-coded digital radiographs. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 107:433-6. Taramsari M, Kajan ZD, Bashirzadeh P, Salamat F. (2013): Comparison of high-resolution and standard zoom imaging modes in cone beam computed tomography for detection of longitudinal root fracture: An in vitro study. Imaging Sci Dent. 43:171-7. Uzun I, Gunduz K, Celenk P, Avsever H, Orhan K, Canitezer G, et al. (2015): Comparing the effect of different voxel resolutions for assessment of vertical root fracture of permanent teeth. Iran J Radiol. 12:e18290. BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS EFFECT OF DIFFERENT EXPOSURE SETTINGS ON THE DIAGNOSIS OF VERTICAL ROOT FRACTURES 121