Human Immunodeficiency Virus type 1 (HIV-1) p24 / Capsid Protein p24 ELISA Pair Set

Similar documents
HIV-1 p24 ELISA Pair Set Cat#: orb54951 (ELISA Manual)

Human Immunodeficiency Virus type 1 (HIV-1) gp120 / Glycoprotein 120 ELISA Pair Set

Influenza A H7N9 (A/Anhui/1/2013) Hemagglutinin / HA ELISA Pair Set

Human LDL Receptor / LDLR ELISA Pair Set

Influenza B Hemagglutinin / HA ELISA Pair Set

Influenza A H1N1 (Swine Flu 2009) Hemagglutinin / HA ELISA Pair Set

Influenza A H1N1 HA ELISA Pair Set

Human Urokinase / PLAU / UPA ELISA Pair Set

2009 H1N1 Influenza ( Swine Flu ) Hemagglutinin ELISA kit

H5N1 ( Avian Flu ) Hemagglutinin ELISA Pair Set

human Total Cathepsin B Catalog Number: DY2176

Human TSH ELISA Kit. User Manual

Human Thyroid-Peroxidase Antibody, TPO-Ab ELISA Kit

Rat cholesterol ELISA Kit

Canine Thyroid Stimulating Hormone, TSH ELISA Kit

Insulin (Porcine/Canine) ELISA

HbA1c (Human) ELISA Kit

Human HIV (1+2) antigen&antibody ELISA Kit

SIV p27 Antigen ELISA Catalog Number:

Procine sphingomyelin ELISA Kit

Fish follicle-stimulating hormone, FSH ELISA Kit

Human Apolipoprotein A1 EIA Kit

STAT1 (ps727) (Human/Mouse) ELISA Kit

Mouse C-Peptide ELISA Kit

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum

EliKine Free Thyroxine (ft4) ELISA Kit

HIV-1 p24 Antigen ELISA Catalog Number:

RayBio Human Granzyme B ELISA Kit

Mouse C-peptide ELISA

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Rat Proinsulin ELISA

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

Rat Mullerian Inhibiting Substance/Anti-Mullerian hormone, MIS/AMH ELISA kit

Mouse Ultrasensitive Insulin ELISA

Mouse C-peptide ELISA

Cotinine (Mouse/Rat) ELISA Kit

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures.

Page 1 of 2. Standard curve of Human IFN gamma ELISA Ready- SET-Go! Product Information Contents: Human IFN gamma ELISA Ready- SET-Go!

Morinaga Mouse C-peptide ELISA Kit

Ultra-sensitive Human TSH ELISA Kit. MyBioSource.com

STAT3 (py705)/ Pan STAT3 (Human/Mouse/Rat) ELISA Kit

Porcine/Canine Insulin ELISA

Bovine Insulin ELISA

Serum Amyloid A ELISA

APOB (Human) ELISA Kit

Human cholesterol, CH ELISA Kit

Prothrombin (Human) ELISA Kit

EGFR (py1045)/ Pan EGFR (Human) ELISA Kit

STAT3 (py705) (Human/Mouse/Rat) ELISA Kit

TECHNICAL BULLETIN. Catalog Number RAB0447 Storage Temperature 20 C

Human Mullerian Inhibiting Substance/Anti-Mullerian hormone, MIS/AMH ELISA Kit

Nori Rabbit IL-2 ELISA Kit DataSheet

Rabbit Glycated hemoglobin A1c (GHbA1c) ELISA Kit

Rat IL-2 ELISA Kit. Instructions for use. For research use only. Fast Track Your Research.

LDL (Human) ELISA Kit

Mouse Cathepsin B ELISA Kit

EXOTESTTM. ELISA assay for exosome capture, quantification and characterization from cell culture supernatants and biological fluids

TECHNICAL BULLETIN. Phospho-Akt (pser 473 ) ELISA Kit for detection of human, mouse, or rat phospho-akt (pser 473 ) in cell and tissue lysates

RayBio Human Phospho-DDR1 (Tyr792) ELISA Kit

Apolipoprotein A-1 ELISA

GSI Canine IL-5 ELISA Kit-2 Plates DataSheet

RayBio Human Phosphotyrosine BTK ELISA Kit

RayBio Human Phospho-DDR1 (Tyr792) and Total DDR1 ELISA Kit

SIV p27 ANTIGEN CAPTURE ASSAY

Human LDL ELISA Kit. Innovative Research, Inc.

Human Cathepsin V ELISA Kit

Human Cathepsin D ELISA Kit

RayBio Human Phospho-DDR2 (Tyr740) and Total DDR2 ELISA Kit

Insulin ELISA. For the quantitative determination of insulin in serum and plasma.

Thyroid Stimulating Hormone (S-TSH) Thyroid Stimulating

TECHNICAL BULLETIN. GLP-1 EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0201 Storage Temperature 20 C

HBeAg and HBeAg Ab ELISA Kit

RayBio Human, Mouse and Rat Phospho-NF-kB P65 (Ser536) and Total NF-kB P65 ELISA Kit

Mouse HBsAg(Hepatitis B Virus Surface Antigen) ELISA Kit

Mouse Adiponectin Immunoassay Kit

MANUAL IL-1alpha (mouse) ELISA Kit Cat. No. AG-45B-0003-KI01 [Interleukin-1 alpha (mouse) ELISA Kit]

RayBio Human ENA-78 ELISA Kit

Vedolizumab Drug Level ELISA

Hepatitis A virus IgM ELISA Kit

Influenza A IgG ELISA

RayBio Human Thyroglobulin ELISA Kit

Mouse Leptin ELISA Kit Instructions

Mouse TrkB ELISA Kit

AssayMax Human Aldose Reductase ELISA Kit

Human Obestatin ELISA

CoQ10(Coenzyme Q10) ELISA Kit

Human IL-2 ELISA Antibody Pair

ab Cathepsin D Human ELISA Kit

Insulin ELISA. For the quantitative determination of insulin in serum and plasma

Human IL-2. Pre-Coated ELISA Kit

HIV-1 p24 ELISA Kit. Catalog Number KA assays Version: 06. Intended for research use only.

Human coagulation factor Xa, FXa ELISA Kit

DRG International, Inc., USA Fax: (908)

HIV-1 p24 ANTIGEN CAPTURE ASSAY

Human Cathepsin V ELISA Kit

Mouse Myeloperoxidase/MPO ELISA Kit

AFLATOXIN M1 CAT. NO. 961AFLMO1M

Mouse Leptin ELISA Kit (mleptin-elisa)

Transcription:

Human Immunodeficiency Virus type 1 (HIV-1) p24 / Capsid Protein p24 ELISA Pair Set Catalog Number : SEK11695 To achieve the best assay results, this manual must be read carefully before using this product and the assay is run as summarized in the General ELISA protocol. 1

BACKGROUND Human Immunodeficiency Virus ( HIV ) can be divided into two major types, HIV type 1 (HIV-1) and HIV type 2 (HIV-2). HIV-1 is related to viruses found in chimpanzees and gorillas living in western Africa. HIV- 2 is related to viruses found in sooty mangabeys. HIV-1 viruses may be further divided into groups. The HIV-1 group M viruses predominate and are responsible for the AIDS pandemic. Some of the HIV-1 group M subtypes are known to be more virulent or are resistant to different medications. HIV-2 viruses are thought to be less virulent and transmissible than HIV-1 M group viruses. Gag protein from HIV-1 is a polyprotein, which, during viral maturation, is cleaved to release matrix p17, core p24 and nucleocapsid proteins. Capsid protein p24 forms the conical core that encapsulates the genomic RNA-nucleocapsid complex in the virion. Most core are conical, with only 7% tubular. The core is constituted by capsid protein hexamer subunits. The core is dissassembled soon after virion entry. The p24 antigen contains epitopes that prime helper CD4 T-cells, which have been demonstrated to be protective and it can elicit lymphocyte proliferation. p24 is likely to be an integral part of any multicomponent HIV vaccine. 2

PRINCIPLE OF THE TEST The Sino Biological ELISA Pair Set is a solid phase sandwich ELISA (Enzyme-Linked Immunosorbent Assay). It utilizes a monoclonal antibody specific for Human Immunodeficiency Virus type 1 (HIV-1) p24 / Capsid Protein p24 coated on a 96-well plate. Standards and samples are added to the wells, and any Human Immunodeficiency Virus type 1 (HIV-1) p24 / Capsid Protein p24 present binds to the immobilized antibody. The wells are washed and a horseradish peroxidase conjugated mouse anti-human Immunodeficiency Virus type 1 (HIV-1) p24 / Capsid Protein p24 monoclonal antibody is then added, producing an antibody-antigen-antibody "sandwich". The wells are again washed and TMB substrate solution is loaded, which produces color in proportion to the amount of Human Immunodeficiency Virus type 1 (HIV-1) p24 / Capsid Protein p24 present in the sample. To end the enzyme reaction, the stop solution is added and absorbances of the microwell are read at 450 nm. INTENDED USE The Human Immunodeficiency Virus type 1 (HIV-1) p24 / Capsid Protein p24 ELISA Pair Set is for the quantitative determination of Human Immunodeficiency Virus type 1 (HIV-1) p24 / Capsid Protein p24. This ELISA Pair Set contains the basic components required for the development of sandwich ELISAs. ASSAY PROCEDURE SUMMARY This Pair Set has been configured for research use only and is not to be used in diagnostic procedures. 3

MATERIALS PROVIDED Bring all reagents to room temperature before use. Capture Antibody 0.5 mg/ml of mouse anti-human Immunodeficiency Virus type 1 (HIV-1) p24 / Capsid Protein p24 monoclonal antibody (in PBS, ph 7.4). Dilute to a working concentration of 2 μg/ml in PBS before coating. (Catalog: # 11695-MM08) Detection Antibody 0.2 mg/ml of mouse anti-human Immunodeficiency Virus type 1 (HIV-1) p24 / Capsid Protein p24 monoclonal antibody conjugated to horseradish-peroxidase (HRP) (in PBS, 50 % HRP-Protector, ph 7.4, store at 4 ). Dilute to working concentration of 0.08 μg/ml in detection antibody dilution buffer before use. (Catalog: # 11695-MM15) Standard Each vial contains 30 ng of recombinant Human Immunodeficiency Virus type 1 (HIV-1) p24 / Capsid Protein p24. Reconstitute with 1 ml detection antibody dilution buffer. After reconstitution, store at -20 to -80 in a manual defrost freezer. A seven-point standard curve using 2-fold serial dilutions in sample dilution buffer, and a high standard of 1000 pg/ml is recommended. SOLUTIONS REQUIRED PBS - 136.9 mm NaCl, 10.1 mm Na 2 HPO 4, 2.7 mm KCl, 1.8 mm KH 2 PO 4, ph 7.4, 0.2 μm filtered TBS - 20 mm Tris, 150 mm NaCl, ph 7.4 Wash Buffer - 0.05% Tween20 in TBS, ph 7.2-7.4 Blocking Buffer - 2% BSA in Wash Buffer Sample dilution buffer - 0.1% BSA in wash buffer, ph 7.2-7.4, 0.2 μm filtered Detection antibody dilution buffer - 0.5% BSA in wash buffer, ph 7.2-7.4, 0.2 μm filtered Substrate Solution : To achieve best assay results, fresh substrate solution is recommended Substrate stock solution - 10mg / ml TMB ( Tetramethylbenzidine ) in DMSO Substrate dilution buffer - 0.05M Na 2 HPO 4 and 0.025M citric acid ; adjust ph to 5.5 Substrate working solution - For each plate dilute 250 μl substrate stock solution in 25ml substrate dilution buffer and then add 80 μl 0.75% H 2 O 2, mix it well Stop Solution - 2 N H 2 SO 4 PRECAUTION The Stop Solution suggested for use with this Pair Set is an acid solution. Wear eye, hand, face, and clothing protection when using this material. 4

STORAGE Capture Antibody: Aliquot and store at -20 to -80 for up to 6 months from date of receipt. Avoid repeated freeze-thaw cycles. Detection Antibody: Store at 4 and protect it from prolonged exposure to light for up to 6 months from date of receipt. DO NOT FREEZE! Standard: Store lyophilized standard at -20 to -80 for up to 6 months from date of receipt. Aliquot and store the reconstituted standard at -80 for up to 1 month. Avoid repeated freezethaw cycles. 5

GENERAL ELISA PROTOCOL Plate Preparation 1.Dilute the capture antibody to the working concentration in PBS. Immediately coat a 96-well microplate with 100μL per well of the diluted capture antibody. Seal the plate and incubate overnight at 4. 2.Aspirate each well and wash with at least 300μl wash buffer, repeating the process two times for a total of three washes. Complete removal of liquid at each step is essential for good performance. After the last wash, remove any remaining wash buffer by inverting the plate and blotting it against clean paper towels. 3.Block plates by adding 300 μl of blocking buffer to each well. Incubate at room temperature for a minimum of 1 hour. 4.Repeat the aspiration/wash as in step 2. The plates are now ready for sample addition. Assay Procedure 1.Add 100 μl of sample or standards in sample dilution buffer per well. Seal the plate and incubate 2 hours at room temperature. 2.Repeat the aspiration/wash as in step 2 of plate preparation. 3.Add 100 μl of the detection antibody, diluted in antibody dilution buffer, to each well. Seal the plate and incubate 1 hour at room temperature. 4.Repeat the aspiration/wash as in step 2 of plate preparation. 5.Add 200 μl of substrate solution to each well. Incubate for 20 minutes at room temperature ( if substrate solution is not as requested, the incubation time should be optimized ). Avoid placing the plate in direct light. 6.Add 50 μl of stop solution to each well. Gently tap the plate to ensure thorough mixing. 7.Determine the optical density of each well immediately, using a microplate reader set to 450 nm. CALCULATION OF RESULTS Calculate the mean absorbance for each set of duplicate standards, controls and samples. Subtract the mean zero standard absorbance from each. Construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. To determine the concentration of the unknowns, find the unknowns mean absorbance value on the y- axis and draw a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the x-axis and read the concentration. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor. Alternatively, computer-based curve-fitting statistical software may also be employed to calculate the concentration of the sample. 6

TYPICAL DATA This standard curve is only for demonstration purposes. A standard curve should be generated for each assay. PERFORMANCE CHARACTERISTIC SENSITIVITY The minimum detectable dose of Human Immunodeficiency Virus type 1 (HIV-1) p24 / Capsid Protein p24 was determined to be approximately 15.63 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. 7

TROUBLE SHOOTING Problems Possible Sources Solutions Incorrect or no Detection Antibody was added Add appropriate Detection Antibody and continue No signal Substrate solution was not added Add substrate solution and continue Incorrect storage condition Check if the kit is stored at recommended condition and used before expiration date Standard was incompletely reconstituted or was inappropriately stored Aliquot reconstituted standard and store at -80 Poor Standard Curve Poor detection value High Background Imprecise / inaccurate pipetting Incubations done at inappropriate temperature, timing or agitation Background wells were contaminated The concentration of antigen in samples was too low Samples were ineffective Insufficient washes TMB Substrate Solution was contaminated Check / calibrate pipettes Follow the general ELISA protocol Avoid cross contamination by using the sealer appropriately Enriching samples to increase the concentration of antigen Check if the samples are stored at cold environment. Detect samples in timely manner Use multichannel pipettes without touching the reagents on the plate Increase cycles of washes and soaking time between washes TMB Substrate Solution should be clear and colorless prior to addition to wells Materials were contaminated. Use clean plates, tubes and pipettes tips Non-specificity Samples were contaminated The concentration of samples was too high Avoid cross contamination of samples Try higher dilution rate of samples 8