Dosimetry Optimization System and Integrated Software (DOSIS): a comparison against Fluka code results over a standard phantom

Similar documents
A Real-Time Monte Carlo System for Internal Dose Evaluation Using an Anthropomorphic Phantom with Different Shapes of Tumors Inserted

The Management of Imaging Procedure Dose Nuclear Medicine Dose Indices

Standardization of Radiopharmaceutical Dosimetry

HIGH SENSITIVE RADIATION DETECTOR FOR RADIOLOGY DOSIMETRY

Application of 3D Printing to Molecular Radiotherapy Phantoms. Nick Calvert Nuclear Medicine Group The Christie NHS Foundation Trust, Manchester

Calculation methods in Hermes Medical Solutions dosimetry software

Y90 SIRT Therapy Dosimetric Aspects


Precision of pre-sirt predictive dosimetry

Optimization of a routine method for bone marrow dose estimation in

Ion radiography as a tool for patient set-up & image guided particle therapy: a Monte Carlo study

An Update of VirtualDose Software Used for Assessing Patient Organ Doses from CT Examinations

GATE MONTE CARLO DOSIMETRY SIMULATION OF MARS SPECTRAL CT

Monte Carlo Modelling: a reliable and efficient tool in radiation dosimetry

Dose differences between the three dose calculation algorithms in Leksell GammaPlan

Tracking Doses in the Pediatric Population

Single Photon Emission Tomography Approach for Online Patient Dose Assessment in Boron Neutron Capture Therapy

Review of TG-186 recommendations


Use Of MCNP With Voxel-Based Image Data For Internal Dosimetry Applications

3D Printed Phantoms for MRT Dosimetry

A Snapshot on Nuclear Cardiac Imaging

How to assess doses from internal emitters

Isoeffective Dose Specification of Normal Liver in Yttrium-90 Microsphere Radioembolization*

Colour on-line figures None Colour print figures None

Journal of Radiation Research and Applied Sciences 8 (2015) 317e322. Available online at ScienceDirect

Publishable Summary for 15HLT06 MRTDosimetry Metrology for clinical implementation of dosimetry in molecular radiotherapy

IN VIVO IMAGING Proton Beam Range Verification With PET/CT

Quality and Safety of Patient Healthcare and Personalized Medicine Using Ionizing Radiation

Case 1: 79 yr-old woman with a lump in upper outer quadrant of left breast.

Publishable JRP Summary Report for JRP HLT11 MetroMRT Metrology for Molecular Radiotherapy Background

Internal Dosimetry Development and Evaluation of Methods and Models

SunCHECK Patient Comprehensive Patient QA

Comparison of organ doses estimations in radiology with PCXMC application based on MIRD phantoms and CALDose-X application based on voxel phantoms

Dose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP

Biases affecting tumor uptake measurements in FDG-PET

Physical Bases : Which Isotopes?

Comparison of absorbed fraction of Gamma and Beta rays of I-124 and I-131radio-isotopes in thyroid gland with Monte Carlo Simulation

Pre-clinical radionuclide therapy dosimetry in several pediatric cancer xenografts

Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations

EURADOS: Overview of actions and initiatives in radiation protection in medicine

ROPES eye plaque dosimetry: commissioning and verification of an ophthalmic brachytherapy treatment planning system

PROGRAMME Day 1. Friday 26 th October Session (presentation summaries attached) Speakers

Three-Dimensional Imaging-Based Radiobiological Dosimetry

Internal dosimetry for radioembolization therapy with Yttrium-90 microspheres

Dosimetric Analysis Report

Dosimetry (Dose Estimation) of Internal Emitters. Outline. For Radiation Effects, is Dose the only Answer? Estimation of Dose and not Dosimetry

Validation of the MC platform GATE for radiation therapy applications Evaluation of dose deposited by electrons. Yann Perrot, LPC, CNRS/IN2P3

MODELLING A GAMMA IRRADIATION PROCESS USING THE MONTE CARLO METHOD

Description of the consecutive stages (which took place from December 2002 to July 2003)

Dosimetry and radiobiology for Peptide Receptor Radionuclide Therapy

EMISSION GUIDED RADIATION THERAPY: A FEASIBILITY STUDY

Radiation physics and radiation protection. University of Szeged Department of Nuclear Medicine

Skin Model and its impact on Digital Mammography

Correction of Prompt Gamma Distribution for Improving Accuracy of Beam Range Determination in Inhomogeneous Phantom

Application of the UF Computational Phantoms for Operational Health Physics Dosimetry for NASA

Clinical Implementation of patient-specific dosimetry, comparison with absorbed fraction-based method

Radiopharmaceuticals used in diagnostic and therapeutic

Quantitative Theranostics in Nuclear Medicine

Dose Estimates for Nuclear Medicine Procedures: What are they? Where do they come from?

Hampton University Proton Therapy Institute

Strategic Research Agenda of EURAMED, highlighting synergies

Lu-DOTATATE PRRT dosimetry:

Imaging of Radiation Dose Using Cherenkov Light

Approved by the Study Board of Biomedical Engineering on 1 April 2012 and approved by the Dean on 1 April Exam and assessment

Recent proceedings in Brachytherapy Physics

Guidelines to optimize extremity monitoring and to reduce skin doses in nuclear medicine. Results of the ORAMED Project

Study of the Influence of Radionuclide Biokinetic Distribution in Human Body on the Efficiency Response of Lung Counters

Radiation Exposure to Staff Using PET/CT Facility

Option D: Medicinal Chemistry

Guideline & Reports 医学物理学会教育委員会資料

Dosimetry benchmark for MBDCA

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry

Simulations of Preclinical andclinical Scans in Emission Tomography, Transmission Tomography and Radiation Therapy. Using GATE

The need for standardization of dosimetry in experimental radiation biology

Impact of ICRP-89 Based Models on Dose Estimates for Radiopharmaceuticals and CT Exams. Stabin MG, Kost SD, Clark JH, Pickens DR, Price RR, Carver DE

Medical Use of Radioisotopes

Citation for the original published paper (version of record):

Application of MCNP4C Monte Carlo code in radiation dosimetry in heterogeneous phantom

Inhomogeneity effect in Varian Trilogy Clinac ix 10 MV photon beam using EGSnrc and Geant4 code system

[Setawati et. al., Vol.4 (Iss10): October, 2017] ISSN: DOI: /zenodo

45 Hr PET Registry Review Course

Effect of non- homogeneous breast 3ssue on mean glandular dose assessment in digital breast tomosynthesis

Patient dosimetry for 90 Y selective internal radiation treatment based on 90 Y PET imaging

Dosimetry in Targeted Radionuclide Therapy: The Bad Berka Dose Protocol Practical Experience

OPPORTUNITIES IN BRACHYTHERAPY

Radionuclides in Medical Imaging. Danielle Wilson

Dollars and Sense: Are We Overshielding Imaging Facilities? Part 2

SPECT/CT in Endocrine Diseases and Dosimetry

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

AUTHOR QUERIES - TO BE ANSWERED BY THE CORRESPONDING AUTHOR

Monte Carlo simulation of 192 Ir radioactive source in a phantom designed for brachytherapy dosimetry and source position evaluation.

FLUKA Monte Carlo Simulation for the Leksell Gamma Knife Perfexion TM radiosurgery system

Ionizing Radiation. Alpha Particles CHAPTER 1

LA-UR- Title: Author(s): Submitted to: Approved for public release; distribution is unlimited.

The OpenGATE Collaboration

Radiation Protection in BNCT Patients

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell

State of the art and future development for standardized estimation of organ doses in CT

Transcription:

Dosimetry Optimization System and Integrated Software (DOSIS): a comparison against Fluka code results over a standard phantom Institute of Physics E. Gaviola - CONICET & LIIFAMIRX - Laboratorio de Investigación e Instrumentación en Física Aplicada a la Medicina e Imágenes por Rayos X - University of Córdoba & Department of Physics - FCF-QyN - University of Río IV; Argentina. E-mail: pperez1@famaf.unc.edu.ar Francesca Botta Marta Cremonesi Mahila Ferrari Francesco Guerriero Francisco Malano Institute of Physics E. Gaviola - CONICET & LIIFAMIRX - Laboratorio de Investigación e Instrumentación en Física Aplicada a la Medicina e Imágenes por Rayos X - University of Córdoba; Argentina. Guido Pedroli Ignacio Scarinci LIIFAMIRX - Laboratorio de Investigación e Instrumentación en Física Aplicada a la Medicina e Imágenes por Rayos X - University of Córdoba; Argentina Mauro Valente Institute of Physics E. Gaviola - CONICET & LIIFAMIRX - Laboratorio de Investigación e Instrumentación en Física Aplicada a la Medicina e Imágenes por Rayos X - University of Córdoba; Argentina c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence. http://pos.sissa.it/

Actually, dual-imaging facilities allow obtainance of both mass and activity patient-specific distributions perfectly correlated, which are important to improve dose distributions estimations and radioimmunotherapy treatment planifications accuracy. Calculus methods at voxel level require both quantitative and qualitative validation to obtain improvements in patient-specific dosimetry. The present work presents advances on the development of a novel computational tool dedicated to 3D patient-specific dosimetry at voxel level; and its results analysis and visualization. With the aim of providing a dosimetric tool for planar and tridimensional methods at voxel level, as well as the development of a platform based on fullstochastic methods for α-, β- and γ-emitters used in radiopharmaceutical applications. DOSIS is based on the Boltzmann radiation transport equation to realize energy delivering calculations. Procedures for 2D and 3D dosimetry have been designed tacking into accont established formalism and standards on MIRD Pamphlets. Anatomic and metabolic images, and dose maps resulting of this calculus are analysed and procesed by a special developed and designed software. DOSIS has been preliminary validated on some standard clinic cases in comparison whith other standard procedures used commonly in radionuclide treatments, showing great accordance on its results and a friendly user usability. Finally, a dose calculation over a standard phantom is performed using DOSIS calculation code and FLUKA, validating the radiation transport code of DOSIS. X Latin American Symposium on Nuclear Physics and Applications (X LASNPA), 1-6 December 2013 Montevideo, Uruguay Speaker. www.famaf.unc.edu.ar/~pperez1 c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence.

1. INTRODUCTION Nowadays, dual-imaging techniques allow both anatomic and metabolic correlated information assessment. Facilities like PET-CT or SPECT-CT implement these techniques to obtain the corresponding information at voxel level with a millimeter resolution. Thereby, this information provides patient-specific mass and activity 3D voxelized distributions useful for improving dose distributions estimations and radioimmunotherapy treatment planifications accuracy [1]. Actually, there are several Monte Carlo codes dedicated to radiation transport and energy delivery at voxel level, both at nuclear medicine common energies involved and usual facilities resolution; like PENELOPE, Fluka, MCNP or Geant4. Any calculation method requires both quantitative and qualitative validation, specially if it is aimed to obtain improvements in patient-specific dosimetry field [2] for nuclear medicine applications. Advances on the development of a novel computational tool dedicated to 3D patient-specific dosimetry calculation at voxel level are presented. Its results, analyses and visualization modules are shown from a general point of view, with the aim of providing an scheme of the dosimetric tool for planar and tridimensional method at voxel level and a development of a platform based on stochastic methods for α-, β- and γ-emitters used in radiopharmaceutical applications. DOSIS, as it is named the presented dosimetry system, is based on the Boltzmann radiation transport equation to realize energy delivering calculations. 2D and 3D dosimetry procedures have been designed in according to the established formalism and standards on MIRD Pamphlets 16 and 17 [3]. Anatomic and metabolic images, and dose maps resulting of this calculus are analysed and procesed by a special developed and designed software [4]. DOSIS has been preliminary validated on some standard clinic cases in comparison whith other standard procedures used commonly in radionuclide treatments, showing great accordance on its results and a friendly user usability. Finally, a dose calculation over a standard phantom is performed using DOSIS calculation code and FLUKA, validating the radiation transport code of DOSIS. 2. MATERIALS AND METHODS 2.1 DOSIS DOSIS is a novel developed dosimetry system [5] consisting mainly on complementary modules for 3D and 2D dose distribution assessment. The proposed method uses a in-home developed version of the geometry and radiation transport controllers of physic s package used by PENE- LOPE Monte Carlo (MC) code writen in FORTRAN 77 computational language. Also, it has a friendly graphical user interface (GUI) designed and developed on a Matlab environment which is capable of constructing 3D patient-specific activity and mass distribution from SPECT/PET and CT images, respectively, correctly previously correlated. A general scheme of DOSIS system operation can be observe in Figure 1 and Figure 3 shows both the 3D voxel level dosimetry and planar dosimetry schemes. Further, Figure?? presents main GUI developed for 3D and planar calculations. 2

Figure 1: General schem of DOSIS dosimetry system Figure 2: 3D MC calculation (left) and planar dosimetry automatization (right) schemes Figure 3: 3D MC calculation (left) and planar dosimetry automatization (right) main GUIs 3

2.1.1 PENELOPE MC code The PENetration and Energy LOss of Positrons and Electrons (PENELOPE) code [6] was partilly used for particle transport simulation and energy delivering in DOSIS. This powerful code allows photons, electrons and positrons MC. In PENELOPE, photons tracks are generated using a detailed simulation method taking into account the succesion of events simulated in a cronological order; while electrons and positrons paths, are simulated using a mixed procedure which is very useful for energies involved in nuclear medicine procedures where a detailed simulation would have a extremely high and unnecesary computational cost. PENELOPE is writen as a rutines serie in FORTRAN 77 language and there were specially developed a serie of packages for DOSIS capable of controlling energy deliverging and radiation transport using PENELOPE s physics packages. These packages allow to manage correctly the DOSIS constructed voxelized patient-specific mass and activity distributions. 2.1.2 Matlab platform Matlab 1 is a high level language and an interactive developing environment dedicated to computation and visualization, as well as numerical programming. This toolkit provides tools capable of realizing complex data analysis, algorithm developing and design models and applications for different scientific and technique areas. For DOSIS there were developed routines devoted to interpreting DICOM images from SPECT-CT facilities, to user-defined segmentation mass distribution of anatomic images, handle the radiation transport and energy delivering routines, dose distribution calculation and analysis of it results. Also, all the DOSIS system is operated through a GUI specially developed on Matlab environment. 2.2 Fluka MC code FLUKA is a fully integrated particle physics Monte Carlo simulation package. It has many applications in high energy experimental physics and engineering, shielding, detector and telescope design, cosmic ray studies, dosimetry, medical physics and radio-biology. 2 This code is well widespread used actually with nuclear medicine purposes [7]. For the present job, it was used to 3D voxelized dose calculation over a standard phantom with the aim of analyse DOSIS results over a similar situation. 2.3 Standard phantoms There were studied standard phantoms, the first one considering an homogeneous water mass distribution and the second one taking into account inhomogeneities of bone and air inside the whole water phantom. In the first case there were inserted a 90 Y radionuclide on a non-homogeneous distribution, whereas in the non-homogeneous phantom it was inserted the same radionuclide homogeneously over a definite region as it can be seen on images of results section. Images were obtained by a PET-CT facility and the whole phantoms were of 200mm both for its height and diameter. 1 MATLAB R, Primer. The MathWorks, Inc. c COPYRIGHT 19842013 2 http://www.fluka.org 4

Figure 4: Dose map calculated on homogeneos phantom using Fluka (left) and DOSIS (right) Figure 5: Dose map calculated on non-homogeneos phantom using Fluka (left) and DOSIS (right) 2.3.1 Dose calculation For dose assessment by DOSIS it was considered a 10 8 particles primary shower simulation and Fluka results were obtained on similar conditions. 3. RESULTS Figure 4 reports dose distributions for an arbitrary slice of the water-equivalent homogeneous phantom calculated with Fluka and DOSIS, respectively. Similar results were obtained for nonhomogeneous case and it is shown in Figure 5. Exhaustive profiles comparisons were performed, as shown in Figure 6. Good agreements were obtained in all cases. Further investigations are still in progress aimed to improve the developed tool as well as to check its performance when considering more clinical situations. 4. CONCLUSIONS AND DISCUSSIONS DOSIS is a friendly toolkit offering a wide variety of dosimetry calculation methodologies and it was shown that it is possible to asses both planar dosimetry procedure calculations and voxel level dosimetry estimations. 5

Figure 6: Dose map calculated on non-homogeneos phantom using Fluka (left) and DOSIS (right) A preliminary comparison against other MC code in similar conditions shows good agreement in dose distribution results. Also, further investigations over rutinely clinical situations will be done to improve the performance as a clinical application References [1] Y. Berker et al, Activity quantification combining conjugate-view planar scintigraphies and SPECT/CT data for patient-specific 3-D dosimetry in radionuclide therapy, Eur J Nucl Med Mol Imaging, 2011, 38(12):2173 2185. [2] G. Sgouros, Dosimetry of Internal Emitters, J Nucl Med, 2005; 46(1):18S 27S. [3] W.E. Bolch et al, MIRD Pamphlet No. 17: The Dosimetry of Nonuniform Activity Distributions-Radionuclide S Values at the Voxel Level, J Nucl Med, 1999; 40:11S 36S. [4] P. Pérez et al, Dosimetry for Beta-Emitter Radionuclides by Means of Monte Carlo Simulations. 12 Chapter on Nuclear Medicine, Intech, 2010. [5] P. Pérez et al, DOSIS (Dosimetry Optimization System and Integrated Software): An integrated toolkit for patient specific internal dosimetry, J Nucl Med, 2013; 54 (Supplement 2):1030. [6] F. Salvat et al, PENELOPE-2008: A code system for Monte Carlo simulation of electron and photon transport, OECD Nuclear Energy Agency, Issy-les-Moulineaux, France, 2008. [7] F. Botta et al, Calculation of electron and isotopes dose point kernels with FLUKA Monte Carlo code for dosimetry in nuclear medicine therapy, Med. Phys. 2011 Jul;38(7):3944-54. 6