Cooperation Centre for Scientific Research Relative to Tobacco. CORESTA Guide N 22

Similar documents
E-Vapour (EVAP) Sub-Group 2017 Report. Kitzbühel, Austria October 10, 2017

CORESTA Guide N o 18

Development and validation of a device for measuring puffing topography of e-cigarette users

E-cigarette consumption and puffing topography data. Dr Sudhanshu Patwardhan FDA CTP Workshop, Hyattsville, Maryland. March 9, 2015.

Modelling the effects of user exposure to harmful emissions across the spectrum of nicotine delivery

Contribution To Standards Development For Next Generation Products. Dr Nils ROSE

E-Cigarette Product Regulation and Standardisation

The Effect of Puff Profile and Volume on the Yields of E-Cigarettes

Contribution To Standards Development For Next Generation Products. Eduardo BEREA Alternative Ingredients ENDS 2018 London 4-5 June 2018

Measuring Emissions as Part of a Regulatory Regime. Prof. Riccardo Polosa Professor of Internal Medicine and Convenor CEN TC437/WG4

Safety/risk assessment of electronic cigarettes

ELECTRONIC CIGARETTE EVOLUTION FROM FIRST TO FOURTH GENERATION PRODUCTS AND BEYOND

Pierre-Marie GUITTON Next Generation Nicotine Delivery London June, 2017

Curriculum Vitae. Tory R. Spindle

Development and Validation of a Portable Puffing Topography Analyser

Nicotine delivery to users from cigarettes and from different types of e-cigarettes

Smoking, e-cigs and reduced risk products. Dr John Schoonbee, IMS November 2017

CHARACTERIZATION OF PUFF TOPOGRAPHY DURING 8- HOURS OF AD LIBITUM USE OF MARKTEN E-VAPOR PRODUCTS

UK E-Cigarette Summit Relative risks of cancer posed by combustible and vapourising forms of nicotine delivery: Evidence from chemical exposures

ELECTRONIC CIGARETTES WHAT S THE BOTTOM LINE?

Might Smoking Rates go up in Flames? Dr John Schoonbee, Chief Medical Officer, Swiss Re

Nicotine pharmacokinetics of electronic cigarettes: experimental data and a review of the literature

FEATURES AND PERFORMANCE OF THE HPP SMOKING MACHINE. Dritan Xhillari

Vape to break the smoking habit

HHS Public Access Author manuscript Drug Alcohol Depend. Author manuscript; available in PMC 2016 June 24.

Electronic Cigarette User Plasma Nicotine Concentration and Puff Topography: Influence of Liquid Nicotine Concentration and User Experience

CORESTA Recommended Method No. 84

2015 Report 05 October 2015 Jeju, South Korea

Kevin Walton, Ph.D. Chief, Clinical Research Grants Branch Division of Therapeutics and Medical Consequences NIDA. No disclosures

Harmful and potentially harmful constituents in e-cigarettes

Electronic Cigarettes: What we know so far

Stop the Vape. Maria Hines RN, MSN. Denise Kneubuhler RN, MSN

PROCEDURE FOR GENERATION AND TESTING OF MAINSTREAM TOBACCO HEATING SYSTEM (THS or IQOS) AEROSOL USING A LINEAR SMOKING MACHINE

Effect of Sugars on Selected Toxicant Yields in e-cigarettes

ESPs are battery-operated devices that contain cartridges filled with liquid chemicals. The chemicals turn into a vapour that the user inhales (this

The Latest on Vaping Among U.S. Teens

E lectronic cigarettes (ECs) have been introduced to the market in recent years as alternatives to smoking.

Aerosol Characterisation of e-cigarettes. Ross Cabot, Anna Koc, Caner U. Yurteri & John McAughey

ONLINE AEROSOL ANALYSIS USING FTIR: ASSESSING CARBONYL YIELDS IN E-CIGARETTE AEROSOL

JUUL and Other Emerging Tobacco Products. Emily McClelland, M.S. December 6, 2018

RE: Docket No. FDA-2014-N , Electronic Cigarettes and the Public Health

Evaluation of the Potential for Second-hand Exposure to E-cigarette Aerosol in an Office Environment

Particle Size Distribution of E-Cigarette Aerosols and the Relationship to Cambridge Filter Pad Collection Efficiency

Nicotine Reduction Workshop Role of nicotine in smoking behaviour

Robert L. Cranfield MD. November 24, 2015 ABSTRACT

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

Advanced in vitro exposure systems

Initial puffing behaviors and subjective responses differ between an electronic nicotine delivery system and traditional cigarettes

Smoke Free Policy Practice Guidance Note Guidance on the use of E-Cigarettes by Service Users, Staff and Visitors - V02

Use of electronic cigarettes (vapourisers) among adults in Great Britain

Health Effects of Electronic Nicotine Delivery Systems: A Systematic Review

Key Variables in Assessing ENDS Devices AND WHY THAT ISN T VOLTS

Cardiovascular effects of nicotine vs. cigarette smoke

2017_ST10_JinCathy.pdf. SSPT Document not peer-reviewed by CORESTA

THE SELF-REPORTED AND BEHAVIORAL EFFECTS OF PROPYLENE GLYCOL AND VEGETABLE GLYCERIN IN ELECTRONIC CIGARETTE LIQUIDS

A proposed bridging approach for the assessment of novel tobacco products

Regulatory Support for Tobacco Products. Feeling daunted by the regulatory process for tobacco products? Don t worry Battelle can help.

00:08 For decades our scientists have endeavoured to reduce the risks of tobacco use and continue to do so today. 00:15

Next Generation Products Sandra Costigan, Marianna Gaca, ChuanLiu, Kevin McAdam, James J. Murphyand Christopher Proctor British American Tobacco 21

HHS Public Access Author manuscript Chem Res Toxicol. Author manuscript; available in PMC 2016 August 17.

Electronic cigarettes: Pre-clinical and clinical assessment

E-Cigarette Update: Secondhand Vapour

Global E-Cigarette Market- Industry Analysis & Outlook ( )

Electronic cigarettes

Improving E-Cigarette Research through Measurement and Design ANDREA VILLANTI, PHD MPH E-CIGARETTE SUMMIT MAY 8, 2017

E-Cigarette Aerosol Analysis Report

Matt S. Melvin, Karen C. Avery, Jason W. Flora, Karl A. Wagner. Altria Client Services LLC l Regulatory Sciences 12Oct2016 Final 1

METHOD DEVELOPMENT AND VALIDATION: QUANTIFICATION OF METALS IN LIQUIDS AND AEROSOL OF E-CIGARETTES

What's the Vibe on Vaping? A Novel Gateway to Addiction and Abuse

CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED ARC 5 ELECTRONIC CIGARETTE KIT.

Nicotine delivery from e-cigarettes part I: study designs for two pharmacokinetic studies.

DEVELOPMENT OF A TECHNIQUE FOR THE DETERMINATION OF ph-values OF AEROSOLS GENERATED BY E-CIGARETTES

The importance of offering adult smokers a portfolio of potentially less harmful products

E L E C T R O N I C VA P O R I Z E R S. User Manual

E-Cigarettes and Vapes

Smoking Behaviour Sub-Group (TSB)

REGULATORY OPTIONS FOR MOVING TO THE ELIMINATION OF SMOKING. Ron Borland PhD

Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT

REPORT ON THE 9TH JOINT CROSS-BORDER EMC MARKET SURVEILLANCE CAMPAIGN (2017) E-cigarettes. Final

E-Cigarette Aerosol Analysis Report

Quit and Smoking Reduction Rates in Vape Shop Consumers: A Prospective 12-Month Survey

THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT

E-cigaretes, Dripping, and Automated Dripping Devices (ADD)

Applicant Name: GD Sigelei Electroinc Tech Co., Ltd B7 Building, No.1 District, Xicheng Science and Technology Park, Hengli Town, Dongguan, China

Electronic Nicotine Delivery Systems

Physical and chemical properties of cigarette, heated tobacco and e-cigarette aerosols

Use of e-cigarettes (vapourisers) among adults in Great Britain

S.C. Moldoveanu, A.G. Hudson, A. Harrison. R.J. Reynolds Tobacco Co.

Responsible Practice in E-Vapour Products (EVP) Product Stewardship

The concept that not all tobacco and nicotine products

RISK FROM E-VAPOUR PRODUCTS FOR USERS AND BYSTANDERS

USER MANUAL. Genuine. Satisfaction.

E-Cigarettes: Current Perspective

TOBACCO PRODUCT OR MEDICAL PRODUCT?

V2 NOTEBOOK-CIG AND/OR V2 POWER-CIG

> Cue vaping device. > One e-liquid cartridge. > USB charging cord. > One Buddy Tip for sharing CUE. > This Quick Start Guide

CORESTA RECOMMENDED METHOD N 25

Characterization of the Spatial and Temporal Dispersion Differences Between Exhaled E-Cigarette Mist and Cigarette Smoke

Transcription:

Cooperation Centre for Scientific Research Relative to Tobacco CORESTA Guide N 22 Technical Guide for the Selection of Appropriate Intense Vaping Regimes for E-Vapour Devices February 2018 E-Vapour Sub-Group

CORESTA TECHNICAL GUIDE N 22 Title: Technical Guide for the Selection of Appropriate Intense Vaping Regimes for E-Vapour Devices Status: Valid Note: This document will be periodically reviewed by CORESTA Document history: Date of review Information February 2018 Version 1 EVAP-128-CTG CORESTA Guide No. 22 February 2018 2/12

TABLE OF CONTENTS 1. INTRODUCTION... 4 1.1 Purpose... 4 1.2 Outline... 4 2. PARAMETERS AFFECTING AEROSOL DELIVERY... 5 2.1 Puff duration... 5 2.2 Puff volume... 5 2.3 Puff frequency... 5 2.4 Puff profile... 5 2.5 Puff number... 5 2.6 Battery charge status... 5 2.7 Heating element or atomizer age... 6 2.8 Voltage setting... 6 2.9 Ventilation setting... 6 2.10 Device orientation... 6 3. TOPOGRAPHICAL STUDIES... 7 4. TECHNICAL LIMITATIONS OF AEROSOL GENERATION INSTRUMENTS... 10 5. SUMMARY... 10 6. REFERENCES... 10 EVAP-128-CTG CORESTA GUIDE N 22 February 2018 3/11

1. INTRODUCTION It is likely that regulators will be interested in evaluation of e-vapour devices using intense usage scenarios. Indeed, the U.S. Food and Drug Administration published guidance for Industry titled Premarket Tobacco Product Applications for Electronic Nicotine Delivery Systems in May 2016. Lines 1021 1024 of this draft guidance states: Evaluating new tobacco products under a range of conditions, including both non-intense (e.g., lower levels of exposure and lower volumes of aerosol generated) and intense (e.g., higher levels of exposure and higher volumes of aerosol generated), enables FDA to understand the likely range of delivery of emissions. As such, CORESTA has prepared the following guidance document on the selection of appropriate intense vaping regimes. 1.1 Purpose CORESTA Recommended Method N 81 was published in 2015; this laid out the essential requirements found necessary for the generation and collection of e-vapour aerosol for analytical testing purposes, and may be regarded as reflecting non-intense use (lower volumes of aerosol/lower exposure). The regime has since been further adopted by research laboratories for in-vitro testing purposes. The purpose of this document is to provide guidance on which criteria should be considered when defining the required device and aerosol generation/collection system settings for intense use. Intense use can be regarded as the conditions which will result in higher levels of aerosol generation under normal use conditions (higher volumes of aerosol/higher exposure). 1.2 Outline E-vapour devices cover a wide variety of products, ranging from simple airflow activated e-vapour devices to large button-activated refillable devices with a number of mechanisms by which the user can adjust the device settings to control their vaping experience. Despite the diversity of these devices, the basic mechanism of aerosol generation is by electrical heating of a wick material saturated with an e-liquid and activation via generation of an airflow by user inhalation and/or button activation. The amount of aerosol generated can be affected by a number of factors, including product design (for example, e-liquid volume, voltage, heating element temperature, wick material), user s vaping topography and device settings. Due to the diversity of designs and product types, consumer use behavior may vary markedly; if topography data for the device under study is available, it is recommended to use this as a basis for determining intense usage scenarios. If device-specific topography data is not available, the data presented in Section 3 (Topographical data) may be used in conjunction with the guidance in Section 2 (Parameters affecting aerosol delivery) to design an intense vaping regimen to generate higher aerosol levels for analytical chemical or biological assessment. EVAP-128-CTG CORESTA Guide No. 22 February 2018 4/12

2. PARAMETERS AFFECTING AEROSOL DELIVERY It is important to note that the below parameters are not independent of each other, and need to be regarded collectively when determining intense usage. 2.1 Puff duration The primary factor impacting the amount of aerosol generated is the amount of time for which the heating element is activated (Wilkinson et al, 2016; Margham et al 2016). As long as the heating element remains supplied with e-liquid, the amount of aerosol generated will increase proportionally to the heating time. Puff duration can be influenced by consumer preference, puff volume, and any automatic cutoffs installed in the device to limit the duration of activation. 2.2 Puff volume Puff volume has less effect on the amount of aerosol generated in comparison to cigarettes. Studies have shown higher puff volumes both increasing (Bao et al, 2016) and decreasing (Margham et al, 2016) the amount of aerosol generated. Additionally, in puff-activated devices a certain minimum airflow velocity (a function of puff volume over puff duration) is required for activation. The airflow velocity required for activation may vary depending on device design (Williams and Talbot, 2011). 2.3 Puff frequency Unlike conventional cigarettes, the frequency of puffing has limited bearing on the amount of aerosol generated, as the device is dormant between puffing. Increasing the puff frequency may marginally increase aerosol generation per puff with all other factors remaining constant, as the temperature of the heating element and wick remains elevated (Margham et al, 2016). 2.4 Puff profile Under current device constraints, a square-shaped profile is recommended. A certain minimum airflow velocity is required for device activation in puff-activated devices. With a bell-shaped profile, airflow velocity will be insufficient for activation at the beginning and end of the puff. By using a square puff profile where the airflow is constant, maximum aerosol generation may be assured. 2.5 Puff number Increasing the number of puffs taken during a test run will correspondingly increase the amount of aerosol generated and collected. It is important not to exceed the total capacity of the Cambridge Filter Pad for aerosol absorption during the test run. This has been reported to be up to 850 mg on a 44 mm pad (Miller et al, 2016). It is also important to ensure that the puff number does not exceed the ability of the device to generate additional aerosol (for example, past the point of exhaustion of the liquid reservoir). 2.6 Battery charge status Devices may contain either rechargeable or non-rechargeable batteries. Depending on device design these may either deliver a constant voltage to the heating element during use, or supply a maximum set current at full charge which then slowly declines during use until the battery is discharged to its set cutoff voltage. EVAP-128-CTG CORESTA Guide No. 22 February 2018 5/12

As the amount of aerosol generated will be greatest when maximum voltage is delivered to the heating element (Gillman et al, 2015), it is recommended that batteries are fully charged before use. Additionally, as battery capacity and performance will deteriorate on repeated use fresh batteries should be used. 2.7 Heating element or atomizer age During prolonged use, heating elements may become coated with e-liquid residue and decline in performance due to thermal stress, affecting aerosol generation. For this reason, it is recommended that a new heating element is used for aerosol generation. 2.8 Voltage setting Devices may have controllable voltage delivery to the heating element. As voltage is increased, the amount of aerosol generated will similarly increase (Gillman et al, 2015). 2.9 Ventilation setting Devices may have mechanical features to increase or decrease the amount of air that is mixed with the generated aerosol. As ventilation is increased, the concentration of the aerosol will decrease with all other factors remaining constant; as such, higher aerosol generation may be observed at the minimum ventilation setting. However, it should be understood that modifying the ventilation will also change the device pressure drop and thus, the vaping behavior of the user. 2.10 Device orientation Depending on device design, devices may require an orientation other than horizontal to facilitate efficient wicking of the e-liquid. Device orientation is referred to in CRM81 which states A specific orientation of the product during testing is not specified within this method. Different products or analytical methods may require a product orientation other than horizontal. This information should be taken into account in the machine design. Therefore, careful consideration of device type and performance needs to be assessed and understood prior to design of any (standard or intense) regimen. In addition, AFNOR XP D90-300-3 July 2016 (Electronic cigarettes and e-liquids Part 3: requirements and test methods for emissions -) provides a specified vaping angle of 45±5 degrees downwards (or justification for an alternative tilt angle) devices during testing. Device and instrument settings which would be unrepresentative of typical consumer behaviour should be avoided; for example, extreme puff durations, activation of buttonactivated devices without airflow and use of devices with minimal e-liquid levels. These usage scenarios may result in dry wicking and subsequent generation of thermal degradation by-products, which would be experienced by the user as an unpleasant flavour. It has been reported that consumption by the user under these circumstances will be self-limiting (Farsalinos et al, 2015b). EVAP-128-CTG CORESTA Guide No. 22 February 2018 6/12

3. TOPOGRAPHICAL STUDIES Topography data from recent studies are summarized in Table 1. The critical parameters assessed in these include puff duration, puff interval and puff volume. Table 1: Summary of publications reporting e-vapour vaping topography data (Mean ± SD) Reference Device type Conditions Participant number Measure Puffs/ Day Puffs/Session Puff duration Puff interval Puff volume Flow rate Norton et al., 2014 Lab ad-lib 18 CressMicro 8.7 ± 1.6 3.0 ± 1.6 s 29.6 ± 11.7 s 118.2 ± 13.3 ml Lee et al., 2015 Lab ad-lib 20 CressMicro Initial: 19.3 ± 2.5 1 week: 23.7 ± 2.4 2 weeks: 21.3 ± 2.4 Initial use: 2.2 ± 0.45 s 1 week: 3.1 ± 1.4 s 2 weeks: 2.9 ± 0.9 s Initial use: 19.2 ± 12.1 s 1 week: 15.2 ± 9.9 s 2 weeks: 22.1 ± 22.0 s Initial use: 64.0 ± 21.6 ml 1 week: 66.5 ± 16.7 ml 2 weeks: 63.3 ± 23.4 ml Initial use: 30.6 ± 10.3 ml/s 1 week: 25.1 ± 8.1 ml/s 2 weeks: 24.8 ± 8.6 ml/s Robinson et al., 2015 Nat ural ad-lib 21 wireless personal use monitor 225 ± 59 15 ± 25 (from 3 to 117) 3.5 ± 1.8 s (from 0.7 to 6.9 s) 42.7 ± 12.1 s (from 10 to 150 s) 133 ± 90 ml 9 to 388 ml 37 ± 16 ml/s (from 23 to 102 ml/s) ad-lib 10 min, Behar et al., 2015. Lab 15 min break 20 CressMicro Blu: 33 ± 8 V2: 31 ± 8 Blu: 2.75 ± 0.96 s V2: 2.54 ± 1.04 s Blu: 16.9 ± 8.2 s V2: 18.9 ± 7.3 s Blu: 56 ± 22 ml V2: 45 ± 22 ml Blu: 21 ± 6 ml/s V2: 18 ± 6 ml/s ad-lib 10 min Strasser et al., 2016 Lab ad-lib 10 min (2 sessions : day 5& 10) 28 Video Day 5: 16.1 ± 11.9 Day 10: 13.2 ± 9.4 Day 5: 2.0 ± 0.7 s Day 10: 2.1 ± 0.7 s Day 5: 11.2 ± 5.2 s Day 10: 11.2 ± 5.2 s Robinson et al., 2016 Nat ural 20 wireless personal use monitor 78± 162 (14 to 275) 2.0 ± 0.6 s (from 1 to 3 s) 65.4 ± 24.8 ml (24 to 114 ml) 30.4 ± 9.2 ml/s (19 to 60 ml/s) EVAP-128-CTG CORESTA Guide No. 22 February 2018 7/12

Reference Device type Conditions Participant number Measure Puffs/ Day Puffs/Session Puff duration Puff interval Puff volume Flow rate Farsalinos et al., 2013 Tank Lab ad-lib 80 Digital camera E-CIG: 43 ± 8 EC: 4.2 ± 0.7 s SM-S: 2.1 ± 0.4 s SM-E: 2.3 ± 0.5 s Spindle et al., 2015 Tank Lab Control 12 Non commercial Instrument 10 (control) 4.2 ± 1.1 s 30 s (control) 101.4 ± 50 ml 24.2 ± 10.7 ml/s Dautzenberg and Bricard, 2015 Tank Nat ural ad-lib 185 Smartphone connected 163 ± 138 Isolated puff: 4.6 ± 2.2 s 2-5 puffs: 4.1 ± 1.9 s 6-15 puffs: 3.7 ± 1.8 s >15 puffs: 3.2 ± 1.6 s Mean: 3.8 ± 1.9 s 2-5 puffs: 19.3 ± 15.1 s 6-15 puffs: 16.8 ± 13.2 s >15 puffs: 13.7 ± 11.5 s Mean: 16.6 ± 13.5 s Spindle et al., 2016 tank Lab 2 sessions 10 puffs / 30s ad-lib 90 min 29 Non commercial Instrument Control: 10.0 ± 0.1 ad-lib: 62.6 ± 32.3 Control: 4.5 ± 1.6 s ad-lib: 5.3 ± 2.2 s Control 25.2 ± 1.6 s ad-lib: 102.8 ± 63.1 s Control: 124.6 ± 89.2 ml ad-lib: 148.5 ± 119.6 ml Control: 27.8 ± 19.5 ml/s ad-lib: 27.5 ± 22.6 ml/s Ramôa et al., 2015 Tank with different nicotine (0, 8, 18 or 36 mg/ml). Lab Control 10 puffs/30s (2 sessions 12h 48h) 16 Non commercial Instrument 10 (control) Session 1&2 5.6 ± 2.1 s (0 nic) 5.8 ± 2.2 s (8 nic) 5.2 ± 1.8 s (18 nic) 4.1 ± 1.5 (36 nic) 30 s (control) Session 1&2 196 ± 214.9 ml (0 nic) 193.2 ± 152.1 ml (8 nic) 119.5 ± 66.4 ml (18 nic) 81.4 ± 41.9 ml (36 nic) Session 1&2 33.4 ± 32.3 ml/s (0 nic) 31.1 ± 21.2 ml/s (8 nic) 23.0 ± 10.5 ml/s (18 nic) 20.0 ± 7.7 ml/s (36 nic) Farsalinos et al., 2015 Mod Lab Control 47 E-cig connected Vapers: 89 ± 14 Smokers: 86 ± 7 Vapers: 3.5 ± 0.2 s Smokers: 2.3 ± 0.2 s Cunningham et al., 2016 Tank Lab ad-lib (1 session) 64 55 SA7 modified 21.1 ± 14.9 16.1 ± 8.0 2.0 ± 0.7 s 2.2 ± 0.9 s 23.2 ± 10.6 s 29.3 ± 19.2 s 52.2 ± 21.6 ml 83.0 ± 44.3 ml 39.0 ± 10.3 ml/s 60.6 ± 19.8 ml/s EVAP-128-CTG CORESTA Guide No. 22 February 2018 8/12

Reference Device type Conditions Participant number Measure Puffs/ Day Puffs/Session Puff duration Puff interval Puff volume Flow rate Hua et al., 2013 Nat ural no 9 No topography instrument used 4.3 ± 1.5 s St Helen et al., 2016 all types Lab ad-lib Tank n=8 Cig-a-like n=2 Mod n=3 Video Tank: 80.2 ± 35.3 Cig-a-like: 35 ± 35.2 Mod : 38 ± 30.8 Tank e-cig: 3.2 ± 1.4 s Cig-a-like: 5.2 ± 1.9 s Mod: 3.2 ± 0.7 s Tank: 80.7 ± 51.3 s Cig-a-like: 319 ± 332 s Mod: 82 ± 81 s * = Not Reported The literature also suggests that those that vape for a shorter series of puffs (i.e. 2-5 puffs), have longer puff durations compared to those taking a larger series (>15 puffs). The inter-puff interval is also impacted by series and duration of puffs (Dautzenberg & Bricard, 2015). EVAP-128-CTG CORESTA Guide No. 22 February 2018 9/12

4. TECHNICAL LIMITATIONS OF AEROSOL GENERATION INSTRUMENTS Aerosol should be generated using a collection system capable of meeting the requirements described in CRM 81 using a pre-set puff volume and puff duration. Current commercially available instruments for aerosol generation and collection have the following general limitations: Puff volume: maximum 150-210 ml Puff duration: maximum 9.9 s Puff frequency: minimum 10 s Additional limitations exist for extremes of puff duration and puff frequency; for example, with a 9.9 s puff duration a puff frequency of 10 s will not be possible. Additionally, at extended puff durations and decreased puff frequency the number of ports available for use will be decreased on some instruments. Instruments designed for cigarette smoking may be adapted for use as e-vapour aerosol generators; however, it should be noted that these are more limited in terms of puff duration and lack features such as button pushers or angled vaping heads. In order to accurately align activation with puffing for button activated devices, an instrument equipped with an integrated button pusher should be used. 5. SUMMARY The amount of aerosol generated can be affected by a number of factors, including product design, vaping topography and device settings. In selecting an appropriate aerosol generation regime for intense use, the parameters described in section 4 should be adjusted appropriately taking into account the topography data for the device or type of device in question if available (Table 1). Device and instrument settings should result in higher aerosol generation under normal expected human usage than that observed for non-intense use; it should be understood that the parameters are not independent and the settings should be based on representative intense human usage rather than the maximum extremes of each individual parameter. 6. REFERENCES AFNOR, 2016. XP D 90-300-3 (E) Electronic cigarettes and e-liquids: Part 3: Requirements and test methods for emissions. Bao, B., Joza, P., Rickert, W., 2016. Analysis of 21 carbonyl compounds in e-liquids and e-aerosols by gas chromatography-mass spectrometry after PFBHA Derivatization. Paper presented at TSRC 2016 Behar, R.Z., Hua M., Talbot P., 2015. Puffing topography and nicotine intake of electronic cigarette users. PLoS One. 10, e0117222. CORESTA, 2014. E-Cigarette Task Force Technical Report. 2014 Electronic Cigarette Aerorol Parameters Study CORESTA, 2015. Recommended Method No. 81: Routine Analytical Machine for E-Cigarette Aerosol Generation and Collection - Definitions and Standard Conditions 2015. EVAP-128-CTG CORESTA Guide No. 22 February 2018 10/12

Cunningham, A., Slayford, S., Vas, C., Gee, J., Costigan, S., Prasad, K., 2016. Development, validation and application of a device to measure e-cigarette users puffing topography. Scientific Reports. 6, 35071. Dautzenberg, B., Bricard, D., 2015. Real-Time Characterization of E-Cigarettes Use: The 1 Million Puffs Study. Journal of Addiction Research & Therapy. 6, 229. Farsalinos, K.E., Romagna, G., Tsiapras, D., Kyrzopoulos, S., Voudris, V., 2013. Evaluation of electronic cigarette use (vaping) topography and estimation of liquid consumption: implications for research protocol standards definition and for public health authorities' regulation. International Journal of Environmental Research and Public Health. 10, 2500-14. Farsalinos, K.E., Spyrou A., Stefopoulos C., Tsimopoulo, K., Kourkoveli, P., Tsiapras, D., Kyrzopoulos, S., Poulos, K., Voudris, V., 2015. Nicotine absorption from electronic cigarette use: comparison between experienced consumers (vapers) and naive users (smokers). Scientific Reports. 5: 11269. Farsalinos, K.E., Voudris, V., Poulos, K., 2015. E-cigarettes generate high levels of aldehydes only in 'dry puff' conditions. Addiction, 110(8), 1352-1356. Farsalinos, K.E., Gillman, G., Hecht, S., Polosa, R., Thornburg, J., 2016. Analytical Assessment of e-cigarettes. From Contents to Chemical and Particle Exposure Profiles. ISBN: 978-0-12-811241-0 Gillman, G., Kistler, K.A., Stewart, E.W., Paolantonio, A.R., 2015. Effect of variable power levels on the yield of total aerosol mass and formation of aldehydes in e-cigarette aerosols. Regulatory Toxicology & Pharmacology. 75, 58-65. Hua, M., Yip, H., Talbot, P., 2013. Mining data on usage of electronic nicotine delivery systems (ENDS) from YouTube videos. Tobacco Control. 22, 103-106. Lee, Y.H., Gawron, M., Goniewicz, M.L., 2015. Changes in puffing behavior among smokers who switched from tobacco to electronic cigarettes. Addictive Behaviour. 48, 1-4. Miller, J.H., Wilkinson, J., Flora, J.W., 2015. Effect of puff duration and puff volume on on e-cigarette aerosol collection. Paper presented at CORESTA Smoke Science and Product Technology Joint Study Groups Meeting, October 2015. Miller, J.H, Wilkinson, J., Wilkinson, C., Sink, K., Flora, J.W., Gardner, B., Karles, G., 2016. Puffing profile effects on carbonyl formation in e-cigarette aerosols, Paper presented at CORESTA Congress 2016 ST28. Norton, K.J., June, K.M., O'Connor, R., 2014. Initial puffing behaviors and subjective responses differ between an electronic nicotine delivery system and traditional cigarettes. Tob. Induced Diseases. 12, 1617-9625. Ramôa, C.P., Hiler, M.M., Spindle, T.R., Lopez, A.A., Karaoghlanian, N., Lipato, T., Breland, A.B., Shihadeh, A., Eissenberg, T., 2015. Electronic cigarette nicotine delivery can exceed that of combustible cigarettes: a preliminary report. Tobacco Control. Robinson, R.J., Hensel, E.C., Morabito, P.N., Roundtree, K.A., 2015. Electronic Cigarette Topography in the Natural Environment. PLoS One. 10, e0129296. EVAP-128-CTG CORESTA Guide No. 22 February 2018 11/12

Robinson, R.J., Hensel, E., Roundtree, K., Difrancesco, G., Nonnemaker, J., Lee, Y., 2016. Week Long Topography Study of Young Adults Using Electronic Cigarettes in Their Natural Environment. PLoS One. 11. Spindle, T., Hiler, M.M., Breland, A.B., Karaoghlanian, N., Shihadeh, A., Eissenberg, T., 2016. The Influence of a Mouthpiece-based Topography Measurement Device on Electronic Cigarette User s Plasma Nicotine Concentration, Heart Rate, and Subjective Effects Under Directed and Ad Libitum Use Conditions. Nicotine & Tobacco Research, 19 (4), 469-476. Spindle, T.R., Breland, A.B., Karaoghlanian, N., Shihadeh, A., Eissenberg, T., 2015. Preliminary results of an examination of electronic cigarette user puff topography: the effect of a mouthpiece-based topography measurement device on plasma nicotine and subjective effects. Nicotine & Tobacco Research, 17, 142-149. St Helen, G., Ross, K., Dempsey, D., Benowitz, N.L., 2016. Nicotine Delivery and Vaping Behavior during ad libitum E-cigarette Access. Tobacco Regulatory Science. 2, 363-376. Strasser, A.A., Souprountchouk, V., Kaufmann, A., Blazekovic, S., Leone, F., Benowitz, N.L., Schnoll, R.A., 2016. Nicotine Replacement, Topography, and Smoking Phenotypes of E-cigarettes. Tobacco Regulatory Science. 2, 352-362. Talih, S., Balhas, Z., Eissenberg, T., Shihadeh, A., 2015. Effects of user puff topography, device voltage, and liquid nicotine concentration on electronic cigarette nicotine yield: measurements and model predictions. Nicotine & Tobacco Research. 17(2), 150-157 Williams, M. & Talbot, P., 2011. Variability among electronic cigarettes in the pressure drop, airflow rate, and aerosol production. Nicotine & Tobacco Research. 13(12), 1276-83. EVAP-128-CTG CORESTA Guide No. 22 February 2018 12/12