Neutron Induced Radiation Damage in BaF 2, LYSO and PWO Scintillation Crystals

Similar documents
A Very Fast and Radiation Hard BaF 2 Calorimeter for Mu2e-II. Ren-Yuan Zhu

ɣ-ray Induced Radiation Damage in PWO and LSO/LYSO

Neutrons. ρ σ. where. Neutrons act like photons in the sense that they are attenuated as. Unlike photons, neutrons interact via the strong interaction

LA-UR- Title: Author(s): Submitted to: Approved for public release; distribution is unlimited.

Venue: IEEE NSS/MIC/RTSD Conference, Seoul, South Korea, 27 th October 2013 Workshop: NWK3/RD1 Radiation Protection and Dosimetry

Design of a BSA for Producing Epithermal Neutron for BNCT

Epithermal neutron beams from the 7 Li(p,n) reaction near the threshold for neutron capture therapy

THE HIGH-CURRENT DEUTERON ACCELERATOR FOR THE NEUTRON THERAPY. S.V. Akulinichev, A. V. Andreev, V.M. Skorkin

Single Photon Emission Tomography Approach for Online Patient Dose Assessment in Boron Neutron Capture Therapy

A Feasibility Study of the SLOWPOKE-2 Reactor as a Neutron Source for Boron Neutron Cancer Treatment

Neutron Detection Spring 2002

Radiation Dosimetry at the BNL High Flux Beam Reactor and Medical Research Reactor

DPA calculations with FLUKA

Optimization of an accelerator-based epithermal neutron source for neutron capture therapy

IPPE Iron shell transmission experiment with 14 MeV neutron source and its analysis by the Monte-Carlo method

Market Survey. Technical Description Irradiation Tests

Numerical optimisation of the fission-converter and the filter/moderator arrangement for the Boron Neutron Capture Therapy (BNCT)

Indonesian Journal of Physics and Nuclear Applications Volume 2, Number 2, June 2017, p ISSN X, FSM UKSW Publication

Progress in Reactor and Accelerator Based BNCT at Kyoto University Research Reactor Institute

On Optimizing the 7Li(p,n) Proton Beam Energy and Moderator Materid for BNCT

THERMOLUMINESCENT (TL) DOSIMETRY OF SLOW-NEUTRON FIELDS AT RADIOTHERAPY DOSE LEVEL

RDHA710FR10A1NK. Neutron and Total Ionizing Dose Test Report. October 2009

arxiv: v1 [physics.ins-det] 1 Feb 2015

Study of neutron-dna interaction at the IPEN BNCT Research facility ABSTRACT

Today, I will present the second of the two lectures on neutron interactions.

Neutron Interactions Part 2. Neutron shielding. Neutron shielding. George Starkschall, Ph.D. Department of Radiation Physics

HEALTH RISKS FROM EXPOSURE TO FAST NEUTRONS. Prof. Marco Durante

Bulaksumur, Yogyakarta 55281, Indonesia. Indonesia.

Radiation Dosimeters for Foods. Ashish Anand Department of Biological and Agricultural Engineering Texas A&M University

Peak temperature ratio of TLD glow curves to investigate the spatial variation of LET in a clinical proton beam

Characterization and implementation of Pencil Beam Scanning proton therapy techniques: from spot scanning to continuous scanning

Investigating a cyclotron HM-30 based neutron source for BNCT of deep-seated tumors by using shifting method

A study of beam loss pattern & dose distribution

Djoko S. Pudjorahardjo, Widarto, Isman Mulyadi T

Environmental Testing of NI Products for Big Physics Applications

Introduction. Measurement of Secondary Radiation for Electron and Proton Accelerators. Introduction - Photons. Introduction - Neutrons.

Title. Author(s)Ishikawa, Masayori; Tanaka, Kenichi; Endo, Satrou; H. CitationJournal of Radiation Research, 56(2): Issue Date

Design of Moderator Neutron for Boron Neutron Capture Therapy in Kartini Nuclear Reactor Using Monte Carlo N Particle 5 Simulation

[Setawati et. al., Vol.4 (Iss10): October, 2017] ISSN: DOI: /zenodo

COMPARISON OF RADIOBIOLOGICAL EFFECTS OF CARBON IONS TO PROTONS ON A RESISTANT HUMAN MELANOMA CELL LINE

Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry

V. 4. Design and Benchmark Experiment for Cyclotron-based Neutron Source for BNCT

Lithium Borohydride for Hydrogen Propellant Storage

SIMULATION RESPONSE OF RESISTIVE PLATE CHAMBER FOR FAST NEUTRONS USING GEANT4 MC CODE

Figure 1.1 PHITS geometry for PTB irradiations with: broad beam, upper panel; mono energetic beams, lower panel. Pictures of the setups and of the

Boron Neutron Capture Therapy (BNCT) - Low-Energy Neutron Spectrometer for Neutron Field Characterization - )

Design and Performance Of A Thermal Neutron Beam for Boron Neutron Capture Therapy At The University Of Missouri Research Reactor

University of Wollongong. Research Online

Real Time Spectrometer for thermal neutrons from Radiotherapic Accelerators

The Albedo Dosimeter for Personnel Monitoring in Fast-Neutron Radiation Fields

Imaging of Radiation Dose Using Cherenkov Light

Neutron - a tool in the cancer treatment - C. Paunoiu

On the optimal energy of epithermal neutron beams for BNCT

FINAL TECHNICAL REPORT MICRODOSIMETRY FOR BORON NEUTRON CAPTURE THERAPY DE - FG02-96ER62217

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH A COMBINATION OF TLD ALBEDO AND SULPHUR ACTIVATION TECHNIQUES FOR FAST NEUTRON PERSONNEL DOSIMETRY

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: a monte carlo study

Influence of Radiation Damage obtained under Fast Charged Particle Irradiation on Plasma-Facing Erosion of Fusion Structural Materials

III. Proton-therapytherapy. Rome SB - 5/5 1

GDR in Radiotherapy Treatment Fields with 18 MV Accelerators

Medical Physics 4 I3 Radiation in Medicine

PHY138Y Nuclear and Radiation

Multifunctional Novel Boron-Carbon Fiber Polymer Composites for Mixed Radiation Field Space Applications

Calculation of Dose Distribution Around a Clinical 252. Cf Source for Neutron Therapy Based on AAPM, TG-43 Protocol

Simulation of the BNCT of Brain Tumors Using MCNP Code: Beam Designing and Dose Evaluation

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

Neutron-Gamma Mixed field Dosimetry on a Child phantom under Therapeutic Proton Irradiation using TL Dosimeters

Radiation protection in proton therapy

The ANDANTE project: a multidisciplinary approach to neutron RBE

AUTHOR QUERIES - TO BE ANSWERED BY THE CORRESPONDING AUTHOR


CALIBRATION OF A TLD ALBEDO INDIVIDUAL NEUTRON MONITOR

RPI DOSIMETRY. Therefore the description of the work is grouped in two main areas:

Monte Carlo simulation of carbon ion radiotherapy for. Human Eye

Distribution of Water Phantom BNCT Kartini Research Reactor Based Using PHITS

Report. MONTE CARLO SIMULATIONS AND BENCHMARK STUDIES AT CERN s ACCELERATOR CHAIN CERN-ACC

Dose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP

Monte Carlo Simulation Study on Dose Enhancement by Gold Nanoparticles in Brachytherapy

International Association of Scientific Innovation and Research (IASIR) (An Association Unifying the Sciences, Engineering, and Applied Research)

Comparison between proton boron fusion therapy (PBFT) and boron neutron capture therapy (BNCT): a Monte Carlo study

Preliminary study of MAGAT polymer gel dosimetry for boron-neutron capture therapy

Principles of Radiation

Proton Treatment. Keith Brown, Ph.D., CHP. Associate Director, Radiation Safety University of Pennsylvania

Figure 3. DS02 point-wise kerma coefficients (see Table 2) and DS02 fine group kerma coefficients (see Table 5) for photons in soft tissue.

Determination of Iodine in Biological Materials using Instrumental Neutron Activation and Anti-coincidence Gamma-ray Spectrometry

Application of MCNP4C Monte Carlo code in radiation dosimetry in heterogeneous phantom

The SpecMAT Project: An array of gamma ray detectors around an active target

MODELLING A GAMMA IRRADIATION PROCESS USING THE MONTE CARLO METHOD

Tissue inhomogeneity in proton therapy and investigation of its effects on BRAGG peak by using MCNPX code

nuclear science and technology

Basic radiation protection & radiobiology

Y FILMS DOSIMETR Nederland België / Belgique

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH. Proposal to the ISOLDE and Neutron Time-of-Flight Committee

Radiation Safety. Bethany Gillett 14th Feb After this lecture, you should be able to:

LMJ - DP14 Neutron Pack Calibration

Nuclear Data for Radiation Therapy

Neutron Measurements for Intensity Modulated Radiation Therapy

Improving personal dosimetry of medical staff wearing radioprotective garments: Design of a new whole-body dosimeter using Monte Carlo simulations

Study on Microdosimetry for Boron Neutron Capture Therapy

Monte Carlo Modelling: a reliable and efficient tool in radiation dosimetry

The physics of boron neutron capture therapy: an emerging and innovative treatment for glioblastoma and melanoma

Transcription:

Neutron Induced Radiation Damage in BaF 2, LYSO and PWO Scintillation Crystals Chen Hu, Fan Yang, Liyuan Zhang, Ren-Yuan Zhu California Institute of Technology Jon Kapustinsky, Ron Nelson and Zhehui Wang Los Alamos National Laboratory Paper N22-6 presented in NSS-MIC-2017 at Atlanta on Oct. 25, 2017

Introduction One crucial issue for applications of scintillation crystals in HEP calorimeters is radiation damage in severe radiation environment, such as at the HL-LHC, with 5 10 34 cm -2 s -1 luminosity and 3,000 fb -1 integrated luminosity, up to 130 Mrad ionization dose, 3 10 14 charged hadrons/cm 2 and 5 10 15 n/cm 2 will be expected. In this paper, we report an investigation on neutron induced radiation damage in BaF 2, LYSO and PWO crystals by using the neutrons at the Weapons Neutron Research facility of Los Alamos Neutron Science Center (WNR facility of LANSCE). In 2015 (Exp. 6991), 18 LFS plates of 14 14 1.5 mm3 were irradiated. In 2016 (Exp. 7332) 36 samples of 5 mm thick LYSO, BaF 2, and PWO were irradiated. 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 2

Neutron Irradiation at LANSCE Los Alamos Neutron Science Center (LANSCE) Samples are placed at Target-4 East Port, about 1.2 m away from the neutron production target. East Port Target-4 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 3

n/ɣ/p Spectra and Production Rate Neutrons/Photons/Protons fluxes are calculated by using MCNPX (Monte Carlo N-Particle extended) package. Plotted spectra are tallied in the largest sample volume (averaging) 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 4

Radiation Dose and Fluence Calculation In 2015 run, 18 LFS plates of 14 14 1.5 mm3 were divided into three groups of six each, and were irradiated for 13.4, 54.5 and 118 days respectively. The fluence of each kind of particle was calculated by integration of 800 MeV proton beam current and MC production rate. 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 5

Fluence and Dose in Exp. 6991 (2015) According our proton irradiation test result, the effect of the proton fluence and dose is negligible. The photon ionization dose of up to 230 Mrad is significant, comparing to neutron fluence. Particles Group 1 Fluence (cm -2 ) Group 2 Fluence (cm -2 ) Group 3 Fluence (cm -2 ) Thermal and Epithermal (0<En < 1 ev) 7.01E+14 3.16E+15 6.72E+15 Slow and Intermediate Neutrons (1 ev <En < 1 MeV) 2.56E+15 1.15E+16 2.45E+16 Fast neutrons 1 (En > 1 MeV) 2.24E+14 1.01E+15 2.14E+15 Fast neutrons 2 (En > 20 MeV) 4.34E+13 1.96E+14 4.16E+14 Protons (Ep>1 MeV) 5.31E+11 2.39E+12 5.08E+12 Protons Dose (rad) 1.39E+04 6.25E+04 1.33E+05 Photons (Eg>150 KeV) 6.71E+14 3.02E+15 6.43E+15 Photons Dose (rad) in Air 2.40E+07 1.08E+08 2.30E+08 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 6

Light Output Loss of LFS Plates The light response of LFS samples, group-1, 2 and 3, was measured before and after the neutron irradiation. A degradation of 3%,13% and 24% is observed for Group-1, 2 and 3. 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 7

Comparison with γ/p irradiated Samples Neutron irradiated LFS show consistent light output loss vs. EWLT loss, indicating LO loss can be corrected by a light monitoring. Consistent LO loss as a function of ionization dose indicates a negligible neutron induced damage. 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 8

Pb Shielding Introduced in Exp. 7332 (2016) 5 mm thick Pb shielding was introduced for half of the samples in each group, which attenuated the ionization dose, but not fast neutrons Pb Shielding Capsule (5 mm thick) 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 9

Samples of Exp. 7332 (2016) Three Groups of four BaF 2, LYSO and PWO samples each were irradiated Group Samples Dimensions (mm 3 ) SN Shielding BaF 2 15 15 5 B1, B2 Pb B3, B4 1 LYSO 10 10 5 LS1, LS2 Pb LS3, LS7 PWO 15 15 5 P2, P3 Pb P1, P4 BaF 2 15 15 5 B7, B8 Pb B5, B6 2 LYSO 10 10 5 LS4, LS6 Pb LS9, LS10 PWO 15 15 5 P5, P7 Pb P6, P10 BaF 2 15 15 5 B10, B11 Pb B9, B12 3 LYSO 10 10 5 LS5, LS8 Pb LC1, LC4 PWO 15 15 5 P8, P9 Pb P11, P12 Group-3 Samples after Irradiation Pb shielding LYSO 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 10 BaF 2 PWO

Fluence/Dose in Exp. 7332 (2016) The 3 groups were irradiated for 21.2, 46.3 and 120 days respectively Particles Group-1 Fluence (cm -2 ) Group-2 Fluence (cm -2 ) Group-3 Fluence (cm -2 ) Thermal and Epithermal Neutrons (0<En < 1 ev) 1.23E+15 2.69E+15 6.04E+15 Slow and Intermediate Neutrons (1 ev <En < 1 MeV) 4.50E+15 9.80E+15 2.20E+16 Fast neutrons Fluence 1: (En > 1 MeV) 3.94E+14 8.58E+14 1.93E+15 Fast neutrons Fluence 2: (En>20 MeV) 7.64E+13 1.66E+14 3.74E+14 Protons (Ep>1 MeV) 9.34E+11 2.03E+12 4.57E+12 Protons Dose (rad) 2.44E+04 5.32E+04 1.20E+05 Photons (Eg>150 KeV) 1.18E+15 2.57E+15 5.78E+15 Photons Dose (rad) 4.22E+07 9.21E+07 2.07E+08 Photons Dose (rad) with 5 mm Pb shielding 3.00E+07 6.54E+07 1.47E+08 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 11

Transmittance of LYSO, BaF 2 and PWO LYSO and BaF 2 show less neutron induced absorption than PWO. Pb shielding reduce RIAC for all 3 kinds of crystals. 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 12

Light Output of LYSO, BaF 2 and PWO LYSO and BaF 2 show less light output loss than PWO. Pb shielding reduce light output loss of LYSO and BaF 2 crystals. 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 13

Summary: LYSO, BaF 2 and PWO LO loss <25% of BaF 2 and LYSO after 200 Mrad plus 2 10 15 /cm 2 fast neutrons (>1MeV) indicates an excellent radiation hardness Group No. Crystal With Pb Shielding Without Pb Shielding EWLT Loss (%) L.O. Loss (%) EWLT Loss (%) L.O. Loss (%) Group-1 Dose 3.0 10 7 4.22 10 7 Fluence (cm -2 ) LYSO 2.4 2.3 3.8 6.8 Fast n (>1 MeV): 3.94 10 14 BaF 2 5.9 13.6 6.4 15.3 Fast n (>20 MeV): 7.64 10 13 PWO 12.7 72.9 14.6 79.7 Group-2 Fluence (cm -2 ) Fast n (>1 MeV): 8.58 10 14 Fast n (>20 MeV): 1.66 10 14 Group-3 Fluence (cm -2 ) Fast n (>1 MeV): 1.93 10 15 Fast n (>20 MeV): 3.74 10 14 Dose 6.54 10 7 9.21 10 7 LYSO 4.5 8.4 4.0 10.0 BaF 2 8.4 14.9 9.4 17.0 PWO 24.2 86.2 25.6 100 Dose 1.47 10 8 2.07 10 8 LYSO 6.0 20.1 8.7 22.4 BaF 2 12.6 20.2 15.1 24.4 PWO 40.5 100 44.3 100 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 14

LO Loss vs EWLT Loss Good correlation between LO loss & EWLT loss is observed in all samples, indicating that crystal s LO can be corrected by a light monitoring system LYSO BaF 2 PWO 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 15

RIAC of LYSO, BaF 2 and PWO RIAC consistent with the ionization dose, indicating neutron induced damage is negligible LYSO and BaF 2 show RIAC of 15 and 50 m -1 after 200 Mrad, much less than that of PWO 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 16

LO of LYSO, BaF 2 and PWO LO consistent correlation with the ionization dose, indicating neutron induce damage is negligible 25% LO loss of LYSO and BaF 2 after 207 Mrad plus 2 10 15 n/cm -2, indicating their excellent radiation hardness against ionization dose and fast neutrons. 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 17

Summary BaF 2, LYSO and PWO crystals were irradiated by a combination of ɣ-rays, neutrons and protons at LANSCE in 2015 and 2016. Less than 25% light output loss is observed in BaF 2 and LYSO crystals after 200 Mrad and 2 10 15 n/cm 2, indicating they survive the severe radiation environment expected as the HL-LHC. Radiation damage observed in transmittance and light output is consistent with the ionization dose, indicating neutron induced damage is negligible. This result is consistent with an early observation for PWO crystals irradiated by neutrons up to 10 19 n/cm 2 at the Saclay reactor. 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 18

Neutron Damage in PWO up to 10 19 n/cm 2 Gamma Irradiation at JPL 7.8 10 18 /1.2 10 19 /4.0 10 19 n/cm 2 for fast/epithermal/thermal Corresponding dose received: 33 Grad @ 300 Mrad/h Saclay neutron test: 30 cm -1 @ 420 nm under 300 Mrad/h Caltech Caltech Caltech gamma test: 0.1 cm -1 @ 420 nm Under 1 Mrad/h Neutron induced damage seems negligible [50] R. Chipaux et al., Behaviour of PWO scintillators after high fluence neutron irradiation, in Proc. 8th Int. Conference on Inorganic Scintillators,SCINT2005, A. Getkin and B. Grinyov eds, Alushta, Crimea, Ukraine, September 19 23 (2005), pp. 369 371 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 19

Energy Spectra Expected at HL-LHC FLUKA simulations: Neutrons and charged hadrons are peaked at MeV and hundreds MeV respectively. Cf-252: 2.5 MeV Davis: 67 MeV LANL: 800 MeV CERN: 24 GeV 10/25/17 NSS17, N22-6, by Liyuan Zhang, Caltech. 20