Norland Densitometry A Tradition of Excellence

Similar documents
Introducing the future of DXA. Powerful images. Clear answers. Horizon DXA System

PhenX Measure: Body Composition (#020300) PhenX Protocol: Body Composition - Body Composition by Dual-Energy X-Ray Absorptiometry (#020302)

Standard Operating Procedure TCRC Dual-Energy X-ray Absorptiometry (DXA)

New York State County Comparison of Fall-related Hip Fractures of Older Adults and Number of Dual-X-ray Absorptiometry Machines

DXA When to order? How to interpret? Dr Nikhil Tandon Department of Endocrinology and Metabolism All India Institute of Medical Sciences New Delhi

Interpreting DEXA Scan and. the New Fracture Risk. Assessment. Algorithm

The Bone Densitometry Examination

STRUCTURED EDUCATION REQUIREMENTS IMPLEMENTATION DATE: JULY 1, 2017

Advanced Point-of-Care Bone Health Assessment HOLOGIC OSTEOPOROSIS ASSESSMENT

Prevalence of Osteoporosis p. 262 Consequences of Osteoporosis p. 263 Risk Factors for Osteoporosis p. 264 Attainment of Peak Bone Density p.

Comparison of Bone Density of Distal Radius With Hip and Spine Using DXA

EXAMINATION CONTENT SPECIFICATIONS ARRT BOARD APPROVED: JANUARY 2017 IMPLEMENTATION DATE: JULY 1, 2017

Documentation, Codebook, and Frequencies

Bone Densitometry. Total 30 Maximum CE 14. DXA Scanning (10) 7

New Dual-energy X-ray Absorptiometry Machines (idxa) and Vertebral Fracture Assessment

QDR Series. Discovery and Explorer Advanced Health Assessment

Dual-energy Vertebral Assessment

Fat Mass. Baseline. (lbs) (lbs) Composition Trend: Total. Aug 17. Apr 17. May 17. Jun 17. Jul 17. Measured Date

Quality Assurance and Control in Dual energy X ray Absorptiometry

Understanding Body Composition

Lunar idxa. The intelligent DXA. gehealthcare.com

Prodigy. from GE Healthcare. Most trusted, reliable and best-selling DXA system with one of the largest installed base in the world. gehealthcare.

Medical Policy. MP Whole Body Dual X-Ray Absorptiometry to Determine Body Composition

Hollowed. Bone. 1. Definition of Term. Normal Bone. Osteoporosis 골다공증

Bone Mass Measurement BONE MASS MEASUREMENT HS-042. Policy Number: HS-042. Original Effective Date: 8/25/2008

2013 ISCD Official Positions Adult

The Bone Wellness Centre - Specialists in Dexa Total Body 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

Effect of Precision Error on T-scores and the Diagnostic Classification of Bone Status

DEXA Bone Mineral Density Tests and Body Composition Analysis Information for Health Professionals

Bone Densitometry Radiation dose: what you need to know

Adina Alazraki, MD, FAAP Assistant Professor, Radiology and Pediatrics Emory University School of Medicine Children s Healthcare of Atlanta

Bone Densitometry. What is a Bone Density Scan (DXA)? What are some common uses of the procedure?

Diagnostische Präzision von DXL im Vergleich zu DXA bei pmp Frauen mit Frakturen

Does standardized BMD still remove differences between Hologic and GE-Lunar state-of-the-art DXA systems?

Lunar Prodigy Advance

Chapter 17: Body Composition Status and Assessment

Objectives. Discuss bone health and the consequences of osteoporosis on patients medical and disability status.

DUAL ENERGY X-RAY ABSORPTIOMETRY (DXA) GOLD STANDARD FOR BONE HEALTH AND BODY COMPOSITION ASSESSMENT

Annotations Part III Vertebral Fracture Initiative. International Osteoporosis Foundation March 2011

Whole Body Dual X-Ray Absorptiometry to Determine Body Composition

Accuracy of DEXA scanning & other methods for determining BMD.

Clinical Application of Computed Radiography in Orthopedic Surgery

TigerPrints. Clemson University. Nadia Marie Ghassan Najm Clemson University

MP Whole Body Dual X-Ray Absorptiometry to Determine Body Composition

Bone Densitometry Equipment Operator

Healthy aging. It s vital.

Bone Mineral Density and Its Associated Factors in Naresuan University Staff

Clinical Densitometry

Powerful images. Clear answers.

DELPHI. The standard in point-of-care fracture risk assessment. Now with Image Pro.

The Bone Wellness Centre - Specialists in Dexa Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

chapter Bone Density (Densitometry) RADIOPHARMACY INDICATIONS Radionuclide Localization Quality Control Adult Dose Range Method of Administration

pqct Measurement of Bone Parameters in Young Children

TOTAL BODY COMPOSITION

DXA Best Practices. What is the problem? 9/29/2017. BMD Predicts Fracture Risk. Dual-energy X-ray Absorptiometry: DXA

Bone Densitometry at the Point of Care

BONE MINERAL DENSITY OF BANGLADESHI PEOPLE

Densitometry Techniques

Bone Mineral Density Studies in Adult Populations

CLINIQCT NO-DOSE CT BONE DENSITOMETRY FOR ROUTINE AND SPECIALIST USE.

Bone Densitometry Pathway

Live Educational Programs

Bone Mineral Densitometry with Dual Energy X-Ray Absorptiometry

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

DEVELOPMENT OF A RISK SCORING SYSTEM TO PREDICT A RISK OF OSTEOPOROTIC VERTEBRAL FRACTURES IN POSTMENOPAUSAL WOMEN

CT Imaging of skeleton in small animals. Massimo Marenzana

Whole Body Dual X-Ray Absorptiometry (DXA) to Determine Body Composition

The DXL Calscan heel densitometer: evaluation and diagnostic thresholds

ANNOUNCING THE NEW STONY BROOK UNIVERSITY OUTPATIENT IMAGING CENTER

Skeletal Manifestations

Bone density scanning and osteoporosis

Radiation Physics Principles of DXA Basic Statistics for DXA Essential Anatomy for DXA

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

Preliminary technical data

Osteoporosis/Fracture Prevention

Major accidents in radiotherapy

Measuring Bone Mineral Density

X-Ray Board Reviewing Rules

Body composition analysis by dual energy X-ray absorptiometry in female diabetics differ between manufacturers

Lateral Vertebral Analysis DXA Body Composition Quality Assurance in DXA

Clinical Study Comparison of QCT and DXA: Osteoporosis Detection Rates in Postmenopausal Women

ReviewArticle. Frequently Asked Questions About Bone Mineral Density Test

LUMBAR IS IT IMPORTANT? S. Tantawy,, M.D.

Osteodensitometry in primary and secondary osteoporosis

Technical Principles of Dual Energy X-Ray Absorptiometry

C H A P T E R 14 BODY WEIGHT, BODY COMPOSITION, AND SPORT

The NOF & NBHA Quality Improvement Registry

Client Sex Facility Birth Date Height Weight Measured ####, #### #### (not specified) #### #### #### ####

3 - D i m e n s i o n a l V o l u m e t r i c Q C T B o n e D e n s i t o m e t r y o f t h e H i p a n d S p i n e

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

Official Positions on FRAX

2013 ISCD Combined Official Positions

Quantitative Computed Tomography 4 Introduction

March 2012: Next Review September 2012

Body Mass Index as Predictor of Bone Mineral Density in Postmenopausal Women in India

Lunar idxa. The intelligent DXA. gehealthcare.com

L.W. Sun 1,2, G. Beller 1, D. Felsenberg 1. Introduction. Original Article. Abstract

Cross-reference: MP Whole Body Dual X-Ray Absorptiometry (DEXA) to Determine Body Composition MP Bone Mineral Density

Omnisense: At Least As Good As DXA

Advanced DXA Using TBS insight

Transcription:

Norland Densitometry A Tradition of Excellence

Norland DXA Bone Density Measurement Osteoporosis is a disease marked by reduced bone strength leading to an increased risk of fractures. About 54 million Americans have osteoporosis and low bone mass. Osteoporosis is the major underlying cause of fractures in postmenopausal women and the elderly. These fractures can occur in the bones of the hip, spine, and wrist, but any bone can be affected. Sometimes these fractures can be disabling, especially when they occur in the hip. Patients with osteoporosis usually have no symptoms before fracture, as such early diagnosis and treatment of the disease are of great importance to the quality of life in these patients. Early diagnosis can prevent acute or chronic pain, limitation in the ability to do daily activities, depression and loss of independence. Norland s dual energy x-ray absorptiometry (DXA) XR600/XR800 can measure central sites, such as lumbar spine and hip, as well as distal forearm. Norland DXA is noninvasive, rapid, accurate, and safe. The high precision and accuracy of Norland DXA allows testing of central sites to be used for monitoring as well as diagnosis of osteoporosis. Body Composition Measurement Obesity has reached epidemic proportions globally, with at least 2.8 million people dying each year as a result of being overweight or obese. Obesity can and usually does lower overall quality of life. Obese individuals may not participate in the level of physical activity that other people enjoy. Other weight-related issues that may affect quality of life include type 2 diabetes, high blood pressure, heart disease and stroke. Norland DXA assessment directly measures Fat Mass, Lean Mass, Bone Mineral Content and the % Total Body BMC/Fat Free Mass for the Whole Body or isolated regions of the body in a swift, painless, noninvasive measurement. Norland DXA provides results for bone, lean and fat content in 8 default regions of the body or in operator defined regions of interest. DXA measurements allow total body or regional fat, lean or bone mass to be followed over time so that the effect of disease or treatment can be monitored. Also the Norland DXA provides the Total Percent Fat as well as the Siri and Brozek Underwater Weight Equivalent Fat Percentages.

Norland Technology Flux Range Available in Norland Scanners Norland Flux Adjustment Norland employs automatic point-by-point adjusted x-ray flux so that every study, regardless of subject size, is optimized to be free of detector saturation or starvation to achieve the best precision and accuracy while exposing the patients to lowest radiation dose. X-ray Counts (cps x 100,000) 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 1 2 3 4 5 6 7 8 Filters Available Percent CV In vivo Precision on Norland Scanners 5.00 4.50 4.00 3.50 3.00 2.50 2.00 1.50 1.00 0.50 0.00 AP Spine Total Hip Distal Forearm Proximal Forearm Whole Body Norland Automatic Analysis As validated in clinical studies (Journal of Clinical Densitometry. 11:455, 2008) advanced Norland technology, unlike competitive equipment, provides analysis routines that automatically place all bone edges and regions of interest insuring that over time and between operators the studies will be comparable and consistent. Advanced Calibration Unlike other equipment that calibrates their technology to unspecified standard materials of the moment, Norland calibration supports absolute accuracy of hard and soft tissue measurements tied to pure chemical standards for bone, lean and fat content that can be reexamined when required as technology or software changes over time. Furthermore, while others calibrate their technology to a simplified linear regression, the Norland system calibrates results to a mixed combination of minimal to maximal hard and soft tissue contents that empirically corrects for ever changing x-ray beam hardening. Aluminum Max Acrylic Bone Min BMD Soft Tissue Max Log H Log L

Norland Technology with Lowest Dose Radiation Dose Norland technology employs a pencil-beam design minimizing radiation scatter for the benefit of operators. Norland technology also applies its exclusive dynamic filter system so that only the x-ray needed to obtain good study statistics is used. As a result Norland generates the lowest patient radiation doses in the market. Operator Radiation Dose Patient Radiation Dose All readings are in mrems/hour System Beam Geometry Cone Beam AP Spine Scan Patient Dose 30 msv 3 ft= 0.08 3 ft= 0.07 Wide-Angle Fan Beam Narrow-Angle Fan Beam 36 msv 10 msv Fixed Filter Pencil-beam 5 msv 3 ft= 0.09 Dynamic Filter Pencil-beam 2 msv Investigators (Radiation Protection Dosimetry. 117:288, 2005) confirm the lowest operator doses are obtained on Norland equipment. Indeed, unlike what is seen with other systems, Norland equipment rates well below the Controlled Area Limit set by the International Commission on Radiological Protection (Annals of the ICRP. 21:No 1-3, 1991). Sheahan and associates (Radiation Protection Dosimetry. 117:288, 2005) examined patient radiation dose in systems applying different beam geometries and found that Norland equipment consistently showed studies with the substantially lowest patient dose.

True Body Composition Body Composition Validation of Norland Being a direct three compartment assessment of body composition, DXA has the unique potential to provide advanced gold standard accuracy in bone, lean and fat content measurements. Norland DXA is especially well suited to accurately provide these measurements because it operates with the advantages of pencil beam geometry, dynamic filtration control of flux, a sophisticated regional analysis routine and chemically indexed calibration. This superior accuracy is demonstrated by the consistency with which the results match total body weight. DXA Weight (gm) 120000 100000 80000 60000 40000 20000 Whole Body Mass by Scale and Norland DXA Wang and associates (Journal of Clinical Densitometry. 16:264, 2013) using a Norland scanner have demonstrated a very strong relationship between weight by scale and DXA. The subjects were assessed by Siri Underwater Equivalent Fat Classification as Underfat, Healthy, Overfat or Obese. 0 0 20000 40000 60000 80000 100000 120000 Scale Weight (gm) Norland Composition Detects True Change in Fat Over Time Norland DXA is a true direct assessment of body composition and, unlike BMI, has been shown to be a valuable assessment of changes in fat and lean content in exercise programs (Revista Espanola de Medicina Nuclear e Imagen Molecular. 32:281, 2013). This can be especially critical when clinical programs are trying to treat obesity with a clinically directed diet and exercise program and individuals respond with some loss in fat but some gain in lean mass as seen in the following example. 22.5 22.0 21.5 21.0 20.5 20.0 19.5 Change with a Diet and Exercise Program Jul-06 Aug-06 Oct-06 Nov-06 Jan-07 Mar-07 Apr-07 Jun-07 BMI Siri As seen in the graph, before beginning a treatment program in Autumn, 2006, a girl had a BMI of 20.0 and a Norland DXA Siri % Fat of 22.0%. As seen in the graph, following seven months of clinically directed exercise and diet shows BMI has increased slightly to 20.3 while the Norland DXA Siri% Fat has decreased substantially to 20.0%. The Norland DXA studies demonstrate a positive clinical response exists with soft tissue change being the result of increased lean mass and decreased fat mass.

Bone Reports 1. 2. Bone Density Study The initial assessment of bone density is carried out to directly quantify bone in the regions of interest. Understanding the regional bone density allows subjects and the physician to know where they currently are so that an appropriate clinical program can be undertaken. 3. The bone density report for an initial study provides: 1. facility and patient background information, 4. 5. 2. images of the current study on a minimum to maximum scale, 3. reference graphs, absolute and scored values for selected regions of interest of the current study, 4. absolute bone density, bone mineral content and bone area for each region of interest with T- and Z-scores for each region, 5. reference graphs, absolute and scored values for selected regions of interest of the current study, 6. 6. specified study precision, study settings and scanner details. 1. Bone Density Trending Study The follow-up assessment of a bone density study is carried out to directly quantify change in bone regions of interest. This report allows the clinician to evaluate treatment and the patient to understand their current progress. 2. 4. 5. 3. The bone density report for an initial study provides: 1. facility and patient background information, 2. images of the current study on a minimum to maximum scale, 3. reference graphs, absolute and scored values for selected regions of interest of the current study, 4. absolute bone density, bone mineral content and bone area for each region of interest with T- and Z-scores for each region and short and long term change, 5. reference graphs, absolute and scored values for selected regions of interest of the current study, 6. 6. specified study precision, study settings and scanner details.

Composition Reports Body Composition Study The initial assessment of body composition is carried out to directly quantify bone, lean and fat mass. Understanding their body composition allows subjects to know where they currently are so that future comparison will produce effective evaluations of a program. The composition report for an initial study provides: 1. patient background information, 2. an image made up of bone, lean and fat scaled on a minimum to maximum range, 3. fat assessments as a percentage value, 4. total absolute bone, lean and fat results, 1. 2. 3. 4. 5. 5. images of %Fat and %Lean on a minimum to maximum scale, 6. absolute regional bone, lean and fat results, 6. 7. Siri % Fat Mass grading of Underfat, Healthy, Overfat or Obese for age and sex, 7. 8. specified study precision, study settings and scanner details. 8. Body Composition Trending Study The follow-up assessment of body composition is carried out to directly quantify change in bone, lean and fat mass. This report allows the clinician to evaluate treatment and the patient to understand their current progress. The composition report for a follow-up study provides: 1. facility and patient background information, 2. images of the first and current %Fat study on a minimum to maximum scale, 3. images of the first and current %Lean study on a minimum to maximum scale, 1. 2. 3. 4. trending graphs and absolute values of fat mass for all studies done on the subject, 4. 5. 5. trending graphs and absolute values of lean mass for all studies done on the subject, 6. total absolute bone, lean and fat results with calculated short term (current study to prior study) and long term (current study to first study) change, 7. 6. 7. specified study precision, study settings and scanner details.

First in the World 1968 Norland produces the first commercial densitometer in the world. 1978 Norland applies microprocessor controlled technology in the densitometer. 1983 With Gd-153 commercially available Norland releases one of first dual energy systems the Norland 2600 a spine and hip scanner. 1988 Norland produces the XR-26, the only x-ray based densitometer in the world that is fitted with step-wedge calibration and tied to chemical standards for bone, lean and fat assessment. 1993 Norland produces the dynamic filtration systems allowing the scanner to produce swift studies to regulate x-ray flux for every point in the study this allows swift scanning in every type of scan and avoids the need to use fan-beam geometry. 1998 Norland gets FDA market clearance to use Fracture Risk Assessment to classify a patient as Osteoporotic or Osteopenic. 2007 Norland produces the XR-600 and XR-800 with auto-gain detector technology that optimizes scanner performance allowing faster studies without loss of long-term precision. 2009 Norland gets FDA market clearance to use a Siri % Fat Assessment to directly classify fat content as Underfat, Healthy, Overfat or Obese. NORLAND AT SWISSRAY PIONEER OF DENSITOMETRY Norland at Swissray, W6340 Hackbarth Road, Fort Atkinson, WI 53538 USA, 920-563-8456 www.swissray.com LEADER IN TECHNOLOGY Copyright 2015 Norland at Swissray Form No. 600P170 Rev A 3/15 Printed in USA Certified ISO 13485