Mineral Density Of Subchondral Bone May Be Quantitatively Evaluated Using A Clinical Cone Beam Computed Tomography Scanner

Similar documents
Determining Collagen Distribution in Articular Cartilage by X-ray Micro-computed Tomography

Microstructural changes in the bone tissue and in the bone callus of diabetic rats with and without insulin treatment

Peripheral Quantitative CT (pqct) Using a Dedicated Extremity Cone-Beam CT Scanner

Bone Densitometry Radiation dose: what you need to know

Clinical Study Comparison of QCT and DXA: Osteoporosis Detection Rates in Postmenopausal Women

CT Imaging of skeleton in small animals. Massimo Marenzana

PACS: ERGONOMIC CONSIDERATIONS 1

Regional Distribution of Stress on the Distal Femur in Advanced Osteoarthritis

CLINIQCT NO-DOSE CT BONE DENSITOMETRY FOR ROUTINE AND SPECIALIST USE.

Computer-based 3d Puzzle Solving For Pre-operative Planning Of Articular Fracture Reductions In The Ankle, Knee, And Hip

Musculoskeletal Research

CT NUMBER ACCURACY ANALYSIS FOR RADIOTHERAPY TREATMENT PLANNING IMAGING

PERSPECTIVES OF THE TOOTH RESTORATION TECHNOLOGY BASED ON THE COMPUTED TOMOGRAPHY DATA

Extremities CBCT. Advances in Cone-Beam CT and Emerging Applications: Clinical Motivation 7/14/2015

Cone-Beam CT for MSK Extremities

Quantitative Computed Tomography 4 Introduction

9 Quality Assurance in Bone Densitometry section

Change in Femur Shape during Postnatal Development and Growth of C57BL/6 Mice

Accuracy of DEXA scanning & other methods for determining BMD.

Dual-Energy Imaging of Bone Marrow Edema on a Dedicated Multi-Source Cone-Beam CT System for the Extremities

Quantitative Analysis of Vascular Canals in Vertebral Endplate

Healthy aging. It s vital.

The Use of Radiographs, Dual-energy X-ray Absorptiometry, Quantitative Computed

Bone Investigational Toolkit BIT. Biomechanical Bone Integrity Assessment

Head to new heights with your imaging SCANORA 3D

LUMBAR IS IT IMPORTANT? S. Tantawy,, M.D.

Dual-energy Vertebral Assessment

Feasibility of bone density evaluation using plain digital radiography

Thickness Computation Under In-Vivo Trabecular Bone CT Imaging

Prodigy. from GE Healthcare. Most trusted, reliable and best-selling DXA system with one of the largest installed base in the world. gehealthcare.

CT Imaging at the Point-of-Care

Skyscan 1076 in vivo scanning: X-ray dosimetry

Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis

Anabolic Therapy With Teriparatide Indications Beyond Osteoporosis

STRUCTURED EDUCATION REQUIREMENTS IMPLEMENTATION DATE: JULY 1, 2017

Initial Fixation Strength of Bio-absorbable Magnesium Screw

Creation of Patient-Specific Bone Densitometry Models from 3D Imaging Data

Does standardized BMD still remove differences between Hologic and GE-Lunar state-of-the-art DXA systems?

Lunar idxa. The intelligent DXA. gehealthcare.com

HOW DO WE DIAGNOSE LAMENESS IN YOUR HORSE?

Bone Mineral Densitometry with Dual Energy X-Ray Absorptiometry

Doses from Cervical Spine Computed Tomography (CT) examinations in the UK. John Holroyd and Sue Edyvean

pqct Measurement of Bone Parameters in Young Children

EPiC Series in Health Sciences

Testing Micronized Amnion as a Therapeutic for OA in a Rat Model using Contrast Based Micro-CT Imaging

Institutional review board approval was obtained prior to the start of this study.

Association between bone mineral density and hearing loss in Osteogenesis Imperfecta

TOTAL KNEE ARTHROPLASTY (TKA)

Using GE Lunar DXA to Quantify, Visualize, and Trend Incipient Atypical Femoral Fractures

X-Ray & CT Physics / Clinical CT

BIOBank Innovation: The Customized Bone Graft

S. N. Khan 1, R. M. Warkhedkar 2, A. Shyam 3, B. R. Patil 4

Department of Orthopaedic Surgery, College of Medicine, University of Dammam and King Fahd Hospital of the University, Al-Khobar, Saudi Arabia

L.W. Sun 1,2, G. Beller 1, D. Felsenberg 1. Introduction. Original Article. Abstract

The Effect of Lateral Meniscal Root Injuries on the Stability of the Anterior Cruciate Ligament Deficient Knee

CUSTOMIZED KNEE IMPLANTS. One Patient. One Implant.

MY PATIENT HAS KNEE PAIN. David Levi, MD Chief, Division of Musculoskeletal l limaging Atlantic Medical Imaging

*Department of Animal and Poultry Science and Department of Land Resource Science, University of Guelph, Guelph, Ontario, Canada N1G 2W1

Evaluation of Bone Mineral Status in Adolescent Idiopathic Scoliosis

Norland Densitometry A Tradition of Excellence

THE PENNSYLVANIA STATE UNIVERSITY SCHREYER HONORS COLLEGE DEPARTMENT OF SCIENCE

Bone Densitometry. Total 30 Maximum CE 14. DXA Scanning (10) 7

Brain Atrophy. Brain Atrophy

chapter Bone Density (Densitometry) RADIOPHARMACY INDICATIONS Radionuclide Localization Quality Control Adult Dose Range Method of Administration

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC

Imaging to Assess Bone Strength and its Determinants

Human tooth root canal geometry assessment through micro-ct images

Quantitative and Qualitative Assessment of Thorax Cone Beam CT Image Quality across Multiple Imaging Systems

BONE MINERAL DENSITY OF BANGLADESHI PEOPLE

Prevalence of Osteoporosis p. 262 Consequences of Osteoporosis p. 263 Risk Factors for Osteoporosis p. 264 Attainment of Peak Bone Density p.

Prometheus, Division of Skeletal Tissue Engineering Leuven, KU Leuven, O&N I Herestraat 49 PB813, B-3000 Leuven, Belgium 3

Acoustic Emission Measurement System for the Orthopedical Diagnostics of the Human Femur and Knee Joint

EXAMINATION CONTENT SPECIFICATIONS ARRT BOARD APPROVED: JANUARY 2017 IMPLEMENTATION DATE: JULY 1, 2017

risk in elderly Japanese women.

CS 9300 Family. The power of flexibility

RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE

DIAGNOSTIC IMAGING. OPTIMIZED.

Imaging Choices in Occult Hip Fracture

Flexible Easy Competitive. SCANORA 3Dx - The in-office large field-of-view Cone Beam CT system for Head and Neck imaging

Laminar Thickness: Correlation Against Symptoms of Spinal Stenosis and Changes with Age

Beyond BMD: Bone Quality and Bone Strength

ACOUSTIC EMISSION MEASUREMENT SYSTEM FOR THE ORTHO- PEDIC DIAGNOSTICS OF THE HUMAN FEMUR AND KNEE JOINT

Measurement of computed tomography dose profile with pitch variation using Gafchromic XR-QA2 and thermoluminescence dosimeter (TLD)

Identification of Early Osteoporosis Using Intensity Slicing method

Axial alignment of the lower extremity in Chinese adults. Journal Of Bone And Joint Surgery - Series A, 2000, v. 82 n. 11, p.

Densitometry Techniques

[ICESTM-2018] ISSN Impact Factor

Functional Orthopedic Imaging Capturing Motion, Flow and Perfusion. Case Study Brochure Centre University Hospital Nancy.

DXA When to order? How to interpret? Dr Nikhil Tandon Department of Endocrinology and Metabolism All India Institute of Medical Sciences New Delhi

Why is CT Dose of Interest?

The Bone Densitometry Examination

In-vivo precision of the GE Lunar idxa for the measurement of visceral adipose tissue in

2013 ISCD Official Positions Adult

Dental ConeBeam Computed Tomography (CBCT) X-ray Systems

Prediction Of Pathological Fracture In The Proximal Femora With Bone Lesions Using A CT Scan-based Finite Element Method

Introducing the future of DXA. Powerful images. Clear answers. Horizon DXA System

PhenX Measure: Body Composition (#020300) PhenX Protocol: Body Composition - Body Composition by Dual-Energy X-Ray Absorptiometry (#020302)

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

Sectra Orthopaedic Solutions

Imaging the musculoskeletal system. An Introduction

Transcription:

Mineral Density Of Subchondral Bone May Be Quantitatively Evaluated Using A Clinical Cone Beam Computed Tomography Scanner Mikael J. Turunen, PhD 1, Juha Töyräs, PhD 1, Harri Kokkonen, PhD 2, Jukka S. Jurvelin, Ph.D. 1. 1 University of Eastern Finland, Kuopio, Finland, 2 Kuopio University Hospital, Kuopio, Finland. Disclosures: M.J. Turunen: None. J. Töyräs: None. H. Kokkonen: None. J.S. Jurvelin: None. Introduction: Cone beam computed tomography (CBCT), a clinical technique with high imaging resolution, has been widely used in dentistry [1]. Recently, contrast agent enhanced CBCT (CE-CBCT) was applied successfully for clinical diagnostics of articular cartilage (Fig. 1) [2-3]. As an X-ray technique, CE-CBCT may also provide a tool for early detection of osteochondral lesions. During joint CT-scanning all soft tissues are simultaneously imaged. As restrictions from the cone beam geometry can prevent accurate quantitative analyses [1], bone integrity has rarely been evaluated [4-5]. However, quantitative information about the articular cartilage and bone would be beneficial e.g. for diagnostics of osteoarthritis (OA). We aimed to clarify feasibility of CBCT for measurement of mineral density (BMD) in subchondral, trabecular and cortical bone. Therefore, in this study, we created hydroxyapatite (HA) phantoms which could be used for in vivo evaluation of BMD using CBCT. Further, we validated the phantoms for BMD measurements at four different regions in human distal femur.

Methods: Phantoms: Five phantoms with different densities (250, 500, 750, 1000 and 1250 mg/cm 3 ) were created by mixing synthetic hydroxyapatite powder (reagent grade, Sigma-Aldrich Inc., St Louis, MO) with epoxy in 2 ml Eppendorf tubes. Additionally, one similar tube with only epoxy was created. After the mixing, the tubes were set into programmable rotator-mixer (Grant Bio PTR-30, Keison Products, Chelmsford, UK) and were let to congeal for 72 hours in room temperature to prevent gravitation driven deposition. Subsequently, the tubes were exposed to 100 C for 12 hours to finalize the solidification. The tubes were cut open and the ends of the phantoms were flattened with a saw. The dimensions of the cylindrical shaped phantoms were measured and the volumes were calculated (1.71 ± 0.06 cm 3 ). A micro-ct scanner (Skyscan, 1172. Aartselaar, Belgium) was used to visually ensure the uniformity of the phantoms. Calibration: The volumetric BMDs (vbmd [g/cm 3 ]) of the HA phantoms were determined using dual energy x-ray absorptiometry (DEXA, GE Healthcare Lunar idxa, Madison, WI). The resulting bone mineral content was normalized with the volume to determine the vbmd of each phantom. Furthermore, the HA phantoms were imaged using a clinical CT (Siemens Somatom Definition Edge, Siemens, Germany) and a CBCT scanner (Verity, Planmed Oy, Helsinki, Finland) together with a commercial K 2HPO 4-based CT calibration phantom, developed for hip and spine analysis (Mindways Software Inc., Kiel, Germany). The CT measurements were conducted using total scanning time of 10 s, 3

different tube voltages (120, 100, 70 kv) and 80 mas with a voxel size of 300 x 300 x 500 µm 3. Correspondingly the CBCT measurements were conducted using tube voltages of 96, 90, 84 kv and current of 12 ma with a voxel size of 200 x 200 x 200 µm 3. BMD determination: Ten frozen human distal femora were imaged with a clinical CT and CBCT scanner together with the commercial phantom and the HA phantoms. The same measurement settings were used for calibration, but using only the highest tube voltages. A custom made elastic band with small individual pockets for the HA phantoms was designed for clinical use and was wrapped around the femur for clinical use. Four volumes of interest (VOIs) were segmented from the image-stacks using Mimics (v12.3, Materialise, Leuven, Belgium): cortical bone (shaft), trabecular bone (medial condyle, cylindrical area), subchondral plate and subchondral trabecular bone (lateral condyle). From each image-stack, the average gray-scale values of the phantoms and the segmented bone VOIs were calculated. The BMDs of different VOIs were determined using calibration curve based on the phantom measurements. All data (calibration and BMD determination) were analyzed with MATLAB (R2012b, MathWorks, Inc., MA). Statistics: Linear correlations (Pearson) between the bone BMD values determined against both phantoms and between modalities were calculated. Wilcoxon signed ranks test was used to compare the calibration curves and bone BMD values determined with both phantom and modalities. All statistical analyses were performed using SPSS (IBM SPSS, v. 21, Armonk, NY). Results: The calibration curves of the HA phantoms are shown in Fig. 2. Compared to the DEXA, BMDs of HA phantom, as determined using the commercial phantom with a CT scanner, yielded slightly lower values (not significant). The values determined with the CBCT scanner were higher (p < 0.05 for every tube voltage).

BMD values in distal femora were determined using the DEXA calibration curve for the HA phantoms. The vbmds [g/cm 3 ] in the VOIs of cortical shaft, trabecular bone, subchondral bone and subchondral plate using CBCT with HA phantom were 1.2 ± 0.1, 0.23 ± 0.05, 0.42 ± 0.10 and 0.73 ± 0.08, respectively. Using the CBCT with the commercial phantom the respective vbmds were 1.5 ± 0.1, 0.34 ± 0.04, 0.56 ± 0.10 and 0.93 ± 0.07. The correlation between the bone BMDs determined with both phantoms was significant using both modalities (CT: R 2 > 0.999, p < 0.001; CBCT: R 2 = 0.992, p < 0.001, Fig. 3a,b). The correlations between the modalities were also significant (HA: R 2 = 0.951, p < 0.001; Commercial: R 2 = 0.959, p < 0.001, Fig. 3c,d). Overall, with both modalities the BMD values determined using the HA phantoms were lower (p < 0.001) than the ones determined with commercial phantom. Furthermore, BMD values determined with the clinical CBCT were lower than the values from clinical CT (p < 0.001).

Discussion: This study demonstrates the potential of quantitative analysis of human bone density using a clinical CBCT scanner. The results indicate that the BMD values might not be directly comparable between different instruments. However, due to highly linear calibration curves, CBCT imaging coupled with applicable phantoms can enable quantitative detection of changes in bone density. The present CBCT technique could indicate the differences in mineral density (g/cm 3 ) of cortical, trabecular and subchondral bone. Especially in diagnostics of OA and knee injuries, quantitative and qualitative information on subchondral bone could improve understanding on its role in cartilage degeneration. In this study, a clinically applicable band allowing easy localization of the HA phantoms around the knee (or other limb) was designed and tested with cadaver joints. As a limitation of this study, effects of soft tissue were not evaluated since dissected bone samples were used. For further validation, forthcoming in vivo measurements using the present protocol will reveal the clinical applicability of CE-CBCT for quantitative diagnostics of articular cartilage [2-3] and subchondral bone. Significance: This study demonstrates the potential of quantitative analysis of human bone density using a clinical CBCT scanner. ORS 2015 Annual Meeting Poster No: 1093