Functional OCT for Glaucoma Evaluation

Similar documents
OCT angiography of ONH blood flow in glaucoma

The leading causes of blindness. ocular circulation: Macular Degeneration

What Is New in Optical Coherence Tomography. Ultrahigh-speed OCT makes 3D better

Glaucoma Diagnosis & Tracking with Optical Coherence Tomography

OCT Angiography: The Next Step in Retinal Imaging Jonathan Zelenak D.O.

OCT Angiography. Financial Disclosures: Pre-Test: Which one is Correct?

Glaucoma Diagnosis. Definition of Glaucoma. Diagnosing Glaucoma. Vision Institute Annual Fall Conference

Swept-Source OCT Angiography: SS OCT Angio TM

Structural & Functional Optical Coherence Tomography for Glaucoma Diagnosis

OCT Angiography. SriniVas Sadda, MD

Ultrahigh Speed Imaging of the Rat Retina Using Ultrahigh Resolution Spectral/Fourier Domain OCT

Il contributo dell'angio-oct: valutazione integrata della componente nervosa e vascolare della malattia glaucomatosa

Advances in OCT Murray Fingeret, OD

Ganglion cell complex scan in the early prediction of glaucoma

Visualize. Analyze. Personalize. OCT + OCTA

Simposio GOAL. Coordinatore e moderatore: D. Mazzacane Presidente: L. Rossetti

Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.

Retinal tissue has an intrinsic ability to maintain a relatively

Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Structural examina.on: Imaging

Visualize. Analyze. Personalize. OCT + OCTA. with

Reproducibility of In-Vivo OCT Measured Three- Dimensional Human Lamina Cribrosa Microarchitecture

Introducing ANGIOVUE ESSENTIAL. Built on the Avanti Widefield OCT Platform. OCT Angiography for Primary Eye Care

Available online at Pelagia Research Library. Advances in Applied Science Research, 2013, 4(6):

Assessing the Relationship between Central Corneal Thickness and Retinal Nerve Fiber Layer Thickness in Healthy Subjects

International Journal of Scientific & Engineering Research, Volume 4, Issue 12, December ISSN

NIH Public Access Author Manuscript Br J Ophthalmol. Author manuscript; available in PMC 2010 May 1.

Optical coherence tomography angiography of optic nerve head and parafovea in multiple sclerosis

OCT in the Diagnosis and Follow-up of Glaucoma

To assess the glaucoma diagnostic ability of Fourier Domain Optical Coherence Tomography

NIH Public Access Author Manuscript Br J Ophthalmol. Author manuscript; available in PMC 2010 April 29.

Corporate Medical Policy

8/6/17. Disclosures Aerie Pharmaceuticals Alcon BioTissue Diopsys Optovue Shire

A Comparative Analysis of Ganglion Cell Complex Parameters in Nigerian Negroes with Glaucoma and Macular Disease

Seiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods

Advances in the Structural Evaluation of Glaucoma with Optical Coherence Tomography

LEE EYE CENTRE. YOUR VISION, OUR PASSION LEC EyeNews

HHS Public Access Author manuscript JAMA Ophthalmol. Author manuscript; available in PMC 2016 July 19.

Chun-Hsiu Liu, Ling-Yuh Kao, Ming-Hui Sun, Wei-Chi Wu, and Henry Shen-Lih Chen

SOUTH-EAST EUROPEAN JOURNAL of OPHTHALMOLOGY 2015; 1 (1) 34 40

PRIMUS 200 from ZEISS The essential OCT

History/principles of the OCT What does the normal retinal OCT look like Vitreal disorders Retinal/RPE disorders Choroidal disorders

PRIMUS 200 from ZEISS The essential OCT

New Technologies in Glaucoma Management: From ERG to OCT

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

Optical Coherence Tomography Imaging for Glaucoma Today and Tomorrow. Christopher Kai-Shun Leung

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

THE OPHTHALMOLOGIST S NEEDS FOR THE ANALYSIS OF THE RETINA

Multifunctional 1050 nm Spectral Domain Oct System at 147 khz for Posterior Eye Imaging

Relationship between the GDx VCC and Stratus OCT in Primary Open Angle Glaucoma

A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements

Mark Dunbar: Disclosure

New Concepts in Glaucoma Ben Gaddie, OD Moderator Murray Fingeret, OD Louis Pasquale, MD

Reproducibility of Choroidal Thickness Measurements Across Three Spectral Domain Optical Coherence Tomography Systems

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

Retinal Nerve Fiber Layer Measurement Variability with Spectral Domain Optical Coherence Tomography

Reproducibility of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Optical Coherence Tomography

Corporate Medical Policy

Relationship between GDx VCC and Stratus OCT in juvenile glaucoma

Split-spectrum amplitude-decorrelation angiography with optical coherence tomography

Beyond the C/D Ratio: Evaluating a Glaucomatous Optic Nerve. Marcus Gonzales, OD, FAAO Cedar Springs Eye Clinic COPE ID#: GL

Earlier Detection, Earlier Treatment, Better Outcomes

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

Optical Coherence Tomography: Pearls for the Anterior Segment Surgeon Basic Science Michael Stewart, M.D.

Measurement of retinal blood flow is an important clinical

CLINICAL SCIENCES. Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography

Clinical Use of OCT in Assessing Glaucoma Progression

Rates of Abnormal Retinal Nerve Fiber Layer and Ganglion Cell Layer OCT Scans in Healthy Myopic Eyes: Cirrus Versus RTVue

OtticaFisiopatologica

Clinical Study Optical Coherence Tomography Angiography in Retinal Vascular Diseases and Choroidal Neovascularization

NIH Public Access Author Manuscript JAMA Ophthalmol. Author manuscript; available in PMC 2013 September 10.

OCT Angiography: The Newest Frontier for the Revolutionary Technology

Citation. As Published Publisher. Version

Quantitative OCT Angiography Evaluation of Peripapillary Retinal Circulation after Plaque Brachytherapy

Reproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography

Individual A-Scan Signal Normalization Between Two Spectral Domain Optical Coherence Tomography Devices

Quantitative optical coherence tomography angiography of vascular abnormalities in the living human eye

Pilot Study of Optical Coherence Tomography Measurement of Retinal Blood Flow in Retinal and Optic Nerve Diseases METHODS

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

Cirrus TM HD-OCT. Details define your decisions

Automated choroidal neovascularization detection algorithm for optical coherence tomography angiography

University Hospital Basel. Optical Coherence Tomography Emerging Role in the Assessment of MS PD Dr. Konstantin Gugleta

Discriminant Function of Optical Coherence Tomography Angiography to Determine Disease Severity in Glaucoma METHODS

Relationship Between Structure

CLINICAL SCIENCES. optic neuropathy characterized

How to Be Efficient and Effective. Disclosure. Topics CASE CM. Case JF 2007 OHTN / POAG? How to Be Efficient and Effective with. with New Technology

Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography

HHS Public Access Author manuscript Ophthalmic Surg Lasers Imaging Retina. Author manuscript; available in PMC 2016 January 14.

International Journal of Advance Engineering and Research Development EARLY DETECTION OF GLAUCOMA USING EMPIRICAL WAVELET TRANSFORM

PLEX Elite 9000 from ZEISS Swept-Source OCT

EXPERIMENTAL AND THERAPEUTIC MEDICINE 6: , 2013

* Şükrü Bayraktar, MD, Zerrin Bayraktar, MD, and Ömer Faruk Yilmaz, MD

Linking structure and function in glaucoma

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

Ophthalmologic Techniques That Evaluate the Posterior Segment for Glaucoma

Behandlungsstrategien beim Offenwinkelglaukom. F. Bochmann, Augenklinik LUKS

Comparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee

This policy is applicable to Commercial Products only. For BlueCHiP for Medicare, see related policy section.

Transcription:

Hawaiian Eye Meeting 18-24 January 2014 Functional OCT for Glaucoma Evaluation David Huang, MD, PhD Weeks Professor of Ophthalmic Research Professor of Ophthalmology & Biomedical Engineering Casey Eye Institute, Oregon Health & Science University Portland, Oregon Financial Interests: OHSU and Dr. D. Huang have a significant financial interest in Optovue, a company that may have a commercial interest in the results of this research and technology. This potential individual conflict of interest has been reviewed and managed by OHSU. Optovue, Inc.: stock options, patent royalty, grants Carl Zeiss Meditec, Inc.: patent royalty OCT captures tissue function as well as structure Signal Information En Face Cross Section Reflectance Anatomy Structural OCT Doppler shift (between consecutive A-scans) Decorrelation (between consecutive B-scans) Total retinal blood flow (global circulation) Angiography (local circulation) Functional OCT David Huang, MD, PhD www.coollab.net 1

Total Retinal Blood Flow Calculation Using Double circular scan 2 sin α : wavelength : Doppler shift : refractive index Doppler angle α 90 Average flow over 2 seconds Dual-circular scan Flow profile and direction determined on parallel sections Total retinal blood flow Summing flow in veins Implemented on RTVue (Optovue, Inc.) 26 khz spectral FD-OCT Experimental software: off-label use of RTVue Wang Y, Lu A, Gil-Flamer J, Tan O, Izatt JA, Huang D. Measurement of total blood flow in the normal human retina using Doppler Fourier-domain optical coherence tomography. Br J Ophthalmol 2009;93:634-637. Total retinal blood flow and vascular caliber were reduced in glaucoma subjects Parameter (27 subjects) Glaucoma (42 subjects) p-value Total Retinal Blood Flow (μl/min) 45.5 ± 9.5 34.9 ± 8.5 < 0.001 Arterial Area (mm²) 0.033 ± 0.0077 0.028 ± 0.0074 0.006 Venous Area (mm²) 0.047 ± 0.012 0.041 ± 0.0086 0.01 Huang JC, Konduru R, Zhang X, Tan O, Francis BA, Varma R, Sehi M, Greenfield DS, Sadda SR, Huang D. Relationship among visual field, blood flow, and neural structure measurements in glaucoma. IOVS 2012; 53:3020 2

Blood flow was highly correlated with visual field, but not with structural parameters Spearman s correlation coefficient R Parameter Blood Flow (db) cslo Rim Area (db) OCT RNFL Thickness (db) Visual Field MD (db) 0.48 (<0.01) Blood Flow (db) 0.34 (0.02) -0.02 (.91) cslo Rim Area (db) 0.37 (0.01) 0.19 (0.23) 0.36 (0.02) OCT NFL (db) OCT GCC Thickness (db) 0.20 (0.20) 0.03 (0.84) 0.31 (0.04) 0.68 (<0.01) All values in db scale normalized against 27 normal eyes. Age, blood pressure, intraocular pressure, and ocular perfusion pressure were not significantly correlated VF, blood flow, or structural measures Huang JC, Konduru R, Zhang X, Tan O, Francis BA, Varma R, Sehi M, Greenfield DS, Sadda SR, Huang D. Relationship among visual field, blood flow, and neural structure measurements in glaucoma. IOVS 2012; 53:3020 Visual field loss was independently correlated with both blood flow and neural tissue loss Multivariate regression and analysis of variance for visual field mean deviation (MD) Variable 1 Slope (p) R 2 Variable 2 Slope (p) R 2 Total R 2 Model 1 Blood Flow 1.91 (<0.001) 0.26 Rim Area 1.15 (0.006) 0.10 0.36 Model 2 Blood Flow 1.62 (0.001) 0.24 NFL 2.56 (0.03) 0.09 0.33 All values in db scale normalized against 27 normal eyes. Age, blood pressure, intraocular pressure, and ocular perfusion pressure were not significant factors when added to the multivariate models Blood flow is >2 times as important as structural variables in explaining the variation in visual field deviation Huang JC, Konduru R, Zhang X, Tan O, Francis BA, Varma R, Sehi M, Greenfield DS, Sadda SR, Huang D. Relationship among visual field, blood flow, and neural structure measurements in glaucoma. IOVS 2012; 53:3020 3

Blood flow has a direct link with visual function independent of neural structural loss Elevated IOP Loss of retinal ganglion cells & nerve fibers Decreased blood flow Loss of visual field David Huang, MD, PhD www.aigstudy.net Total Retinal Blood Flow Using En Face Doppler OCT Dual Plane s Doppler angle θ measurement imprecise Dual circular OCT scan requires both Doppler shift and angle for blood flow calculation En face Doppler OCT measurement of blood flow requires only Doppler shift Baumann B et al. Biomed Opt Exp 2011;2:539 Choi WJ et al. Biomed Opt Exp 2012; 3:1047 Ou Tan, PhD; David Huang, MD, PhD www.coollab.net 4

Multi-Plane En face Doppler Measurement of Total Retinal Blood Flow Y 2mm 1 2 3 3 1.6mm X 2 5 repeated volume scans in 3 seconds En face Color Doppler Ou Tan, PhD; David Huang, MD, PhD www.coollab.net 1 Flow in each retinal vein is measured at optimal depth (optimal Doppler signal) Implemented on RTVue-XR Avanti (Optovue, Inc.) 70 khz spectral FD-OCT Experimental software: off-label use of RTVue-XR Automated En face Doppler OCT Measurement of Total Retinal Blood Flow Group Mean± SD (µl/min) Repeatability (CV) (9 eyes) 42.0±5.0 11.1 % Glaucoma (5 eyes) 38.1±9.2 9.2 % Advantages of en face v. dual-circular Doppler OCT Fewer scans needed (1 v. 6) Automated measurement algorithm Improved repeatability Ou Tan, PhD; David Huang, MD, PhD; John C. Morrison, MD. Casey Eye Institute 5

Split-Spectrum Amplitude Decorrelation Angiography (SSADA) with Ultrahigh-Speed OCT OCT ANGIOGRAPHY David Huang, MD, PhD www.coollab.net High-Speed Swept-Source OCT Developed by MIT Optic & Quantum Electronic Group (Fujimoto) and OHSU Center for Ophthalmic Optics and Lasers (Huang) Performance features: 100,000 axial scans/sec 1050 nm tunable laser (deep penetration) 5.3 µm axial resolution in tissue Experimental system: not FDA-approved Potsaid B, et al., Optics Express 2010; 18:20029 6

OCT amplitude-decorrelation angiography uses intrinsic contrast no dye injection! D1 D2 D3 D4 D5 D6 D7 Intensity flow static 1 N 1 N 1 n= 1 D n 8 consecutive OCT scans at each position (M-B-scan Mode, N=8) Frame # An( x, z) An+ 1 ( x, z) D ( xz, ) = 1 n 1 2 1 2 [ An( x, z) + An+ 1 ( x, z) ] 2 2 ( n = 1 N 1) static tissue Problem: 8 frames at one position do not provide sufficient angiography quality Flow image Decorrelation blood flow Solution: Split-Spectrum Amplitude Decorrelation (SSADA) Algorithm 32 low resolution OCT amplitude frame 28 decorrelation frame 8 high resolution OCT amplitude frame M-B frames (N=8) Split spectrum (M=4) averaged decorrelation 8 frames at one position now provides good angiography quality 7

Comparison of Angiography Algorithms More continuous microvascular network Less Noise >2x SNR Full-Spectrum Amplitude Decorrelation Split-Spectrum Amplitude Decorrelation Jia Y, Tan O, Tokayer J, Potsaid B, Wang Y, Liu JJ, Kraus MF, Subhash H, Fujimoto JG, Hornegger J, Huang D. Split-spectrum amplitude-decorrelation angiography with optical coherence tomography. Optics Express 2012; 20:4710 OCT Angiography of the Optic Nerve Head Layer by Layer SSADA algorithm used 3x3x3 mm OCT 3D angiography acquired in a 3-second scan Jia Y, Tan O, Tokayer J, Potsaid B, Wang Y, Liu JJ, Kraus MF, Subhash H, Fujimoto JG, Hornegger J, Huang D. Split-spectrum amplitude-decorrelation angiography with optical coherence tomography. Optics Express 2012; 20:4710 8

Pilot Study Subject Characteristics 24 eyes of 24 subjects Age: 52±10 years (mean ± SD) Glaucoma 11 eyes of 11 subjects 8 perimetric glaucoma, 3 pre-perimetric glaucoma Age: 68±10 years Jia Y, Wei E, Wang X, Zhang X, Morrison JC, Parikh M, Lombardi LH, Gattey DM, Armour RL, Edmunds B, Kraus MF, Fujimoto JG, Huang D. Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma. Ophthalmology 2014 in press. Variability of Disc Flow Index (2x 2y registered OCT angiogram) Subjects Intra-Visit Repeatability (n = 4) Inter-Visit Reproducibility (n = 4) Inter-Subject Variability (n = 24) 1.2% 4.2% 5.0% Less variable than OCT NFL measurement! Jia Y, Wei E, Wang X, Zhang X, Morrison JC, Parikh M, Lombardi LH, Gattey DM, Armour RL, Edmunds B, Kraus MF, Fujimoto JG, Huang D. Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma. Ophthalmology 2014 in press. 9

Glaucoma reduced disc flow index Visual field Structure (cslo) Blood flow Parameter Glaucoma P Value* Mean deviation (db) Pattern standard deviation (db) Numbers displayed are mean ± population standard deviation; cslo, scanning laser ophthalmoscopy * Wilxson rank sum 0.20 ± 0.87-3.28 ± 4.12 0.003 1.43 ± 0.20 4.44 ± 3.12 0.003 Rim area (mm 2 ) 1.55 ± 0.34 1.13 ± 0.25 0.007 Cup/Disc area ratio 0.11 ± 0.10 0.37 ± 0.17 0.012 Disc flow index 0.161 ± 0.008 0.121 ± 0.026 0.003 Glaucoma caused a -25% drop of blood flow in optic disc Jia Y, Wei E, Wang X, Zhang X, Morrison JC, Parikh M, Lombardi LH, Gattey DM, Armour RL, Edmunds B, Kraus MF, Fujimoto JG, Huang D. Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma. Ophthalmology 2014 in press. OCT Angiography Showing Reduced ONH Blood Flow in Pre-Perimetric Glaucoma A (OS) ONH flow index = 0.159 Preperimetric Glaucoma (OS) PPG Disc Photo 500µm 500µm OCT Angiography ONH flow index = 0.125 Jia Y, Wei E, Wang X, Zhang X, Morrison JC, Parikh M, Lombardi LH, Gattey DM, Armour RL, Edmunds B, Kraus MF, Fujimoto JG, Huang D. Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma. Ophthalmology 2014 in press. 10

Glaucoma reduces perfusion at multiple levels of optic nerve head Jia Y, Wei E, Wang X, Zhang X, Morrison JC, Parikh M, Lombardi LH, Gattey DM, Armour RL, Edmunds B, Kraus MF, Fujimoto JG, Huang D. Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma. Ophthalmology 2014 in press. Retinal plane Choroidal plane Lamina cribrosa & sclera Perimetric glaucoma Optic disc flow index vs. visual field 0.2 Optic Disc Flow Index 0.17 0.14 0.11 No overlap between normal and glaucoma R = -0.84 0.08 Glaucoma 0.05 1 3 5 7 9 PSD (db) VF PSD (db) Jia Y, Wei E, Wang X, Zhang X, Morrison JC, Parikh M, Lombardi LH, Gattey DM, Armour RL, Edmunds B, Kraus MF, Fujimoto JG, Huang D. Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma. Ophthalmology 2014 in press. 11

Difference between normal and glaucoma not due to age, cup/disc ratio or rim area 0.2 Optic Disc Flow Index 0.2 0.17 0.14 0.11 R = 0.01 0.08 Glaucoma 0.05 30 40 50 60 70 80 Age (yr) 0.2 Optic Disc Flow Index 0.17 0.14 0.11 0.08 Glaucoma 0.05 0 0.5 1 1.5 2 2.5 cslo Rim Area (mm 2 ) Optic Disc Flow Index 0.17 0.14 0.11 0.08 Glaucoma 0.05 0 0.2 0.4 0.6 C/D Area Ratio Jia Y, Wei E, Wang X, Zhang X, Morrison JC, Parikh M, Lombardi LH, Gattey DM, Armour RL, Edmunds B, Kraus MF, Fujimoto JG, Huang D. Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma. Ophthalmology 2014 in press. Conclusion Optic disc microcirculation is reduced in glaucoma Pre-perimetric changes can be detected by quantitative OCT angiography Optic disc flow index can be measured with high repeatability(1.2% CV) and high reproducibility (4.2% CV) Variability is small among normals: 5.0% CV OCT angiography with the SSADA algorithm may be a useful new tool in the evaluation of glaucoma David Huang, MD, PhD, www.coollab.net 12

SSADA on Commercial OCT RTVue-XR Avanti (Optovue, Inc.) 70 khz spectral FD- OCT 3x3 mm SSADA Orthogonal registration and merging of 2 consecutive scans 3.8 sec / scan Experimental software: off-label use of RTVue-XR David Huang, MD, PhD, Yali Jia, PhD www.coollab.net Flow Index on 70 khz Spectral OCT FI = 0.109 RTVue-XR PG FI = 0.082 David Huang, MD, PhD, Yali Jia, PhD www.coollab.net 13

Grants & Material Supports NIH Grant R01 EY023285 Functional and Structural OCT for Glaucoma NIH Grant R01 EY013516 Advanced Imaging for Glaucoma www.aigstudy.net Unrestricted grant from Research to Prevent Blindness Grant & material support from Optovue, Inc. R01 EY013516 www.aigstudy.net Consortium PI: David Huang MD, PhD Ou Tan, PhD Yimin Wang, PhD Xinbo Zhang, PhD Site PI: Rohit Brian Francis, Varma, MD, MPH MD Vikas Chopra, MD Site PI: David Greenfield, MD Mitra Sehi, PhD Carolyn Quinn, MD Krisha S. Kishor, MD Robert DiLaura Sharon Bi, MCIS Site PI: Joel S. Schuman, MD Robert Noecker, MD Gadi Wollstein, MD Hiroshi Ishikawa, MD Larry Kagemann, MS Site PI: James G. Fujimoto, PhD 14

Acknowledgements MIT Benjamin Potsaid, PhD Jonathan J. Liu Bernhard Baumann, PhD Chen D. Lu Woo Jhon Choi James G. Fujimoto, PhD University Erlangen-Nuremberg Martin F. Kraus Joachim Hornegger, PhD Casey Eye Institute, OHSU Glaucoma service John C. Morrison, MD Beth Edmunds, MD, PhD Mansi Parikh, MD www.coollab.net David Huang, MD, PhD Ou Tan, PhD Maolong Tang, PhD Yan Li, PhD Xinbo Zhang, PhD Yali Jia, PhD Gangjun Liu, Kathleen S. PhD Torok, MA Janice Ladwig, COT, CCRP Chad Sorenson, BS Denny Romfh, OD Xiaogang Wang, MD Chenxing Zhang, MD Liang Liu, MD 15