Scanning Laser Tomography to Evaluate Optic Discs of Normal Eyes

Similar documents
Influence of Myopic Disc Shape on the Diagnostic Precision of the Heidelberg Retina Tomograph

Comparison of Optic Disc Topography Measured by Retinal Thickness Analyzer with Measurement by Heidelberg Retina Tomograph II

Study of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma

Optic nerve head morphometry in healthy adults using confocal laser scanning tomography

Correlation of Blue Chromatic Macular Sensitivity with Optic Disc Change in Early Glaucoma Patients

NERVE FIBER LAYER THICKNESS IN NORMALS AND GLAUCOMA PATIENTS

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

Seiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods

Imaging of the optic disc and retinal nerve fiber layer: the effects of age, optic disc area, refractive error, and gender

Retinal nerve fiber layer measured by Heidelberg retina tomograph and nerve fiber analyzer

Relation of optic disc topography and age to thickness of retinal nerve fibre layer as measured using scanning laser polarimetry, in normal subjects

Ability of Scanning Laser Polarimetry (GDx) to Discriminate among Early Glaucomatous, Ocular Hypertensive and Normal Eyes in the Korean Population

RETINAL NERVE FIBER LAYER

Relationship Between Structure

Science & Technologies

Spontaneous Intraocular Pressure Reduction in Normal-Tension Glaucoma and Associated Clinical Factors

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

G laucoma is a progressive optic neuropathy in which

Parafoveal Scanning Laser Polarimetry for Early Glaucoma Detection

A vailability of the scanning laser polarimeter now permits

A comparison of HRT II and GDx imaging for glaucoma detection in a primary care eye clinic setting

Optic Nerve: Clinical Examination

Preperimetric glaucoma diagnosis by confocal scanning laser tomography of the optic disc

Evaluating Optic Nerve Damage: Pearls and Pitfalls

CLINICAL SCIENCES. Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Robert N. Weinreb, MD

* Şükrü Bayraktar, MD, Zerrin Bayraktar, MD, and Ömer Faruk Yilmaz, MD

Morphometric Features of Laminar Pores in Lamina Cribrosa Observed by Scanning Laser Ophthalmoscopy

Abstract Aims The development of imaging and measurement techniques has brought the prospect of greater objectivity in the

CLINICAL SCIENCES. Steven L. Mansberger, MD; Pamela A. Sample, PhD; Linda Zangwill, PhD; Robert N. Weinreb, MD

Correlation of Blue-on-Yellow Visual Fields With Scanning Confocal Laser Optic Disc Measurements

Intro to Glaucoma/2006

Scanning Laser Polarimetry and Optical Coherence Tomography for Detection of Retinal Nerve Fiber Layer Defects

Heidelberg Retina Tomography Analysis in Optic Disks with Anatomic Particularities

Because technological advances have provided the ability. Slope of the Peripapillary Nerve Fiber Layer Surface in Glaucoma

Morphological Study of Corneal Endothelium and Corneal Thickness in Pseudoexfoliation Syndrome

Structural examina.on: Imaging

The evaluation of retinal nerve fiber layer in pigment dispersion syndrome and pigmentary glaucoma using scanning laser polarimetry

S Morishita, T Tanabe, S Yu, M Hangai, T Ojima, H Aikawa, N Yoshimura. Clinical science

The Role of the RNFL in the Diagnosis of Glaucoma

The Measure of Confidence

A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements

Glaucoma is a chronic progressive optic neuropathy,

The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation

Clinical decision making based on data from GDx: One year observations

Relationship between central corneal thickness and parameters of optic nerve head topography in healthy subjects

The evaluation of the optic nerve and retinal nerve

Sensitivity and specificity of new GDx parameters Colen TP, Tang NEML, Mulder PGH and Lemij HG Submitted for publication CHAPTER 7

Relationship between the GDx VCC and Stratus OCT in Primary Open Angle Glaucoma

Reproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography

Introduction. Hemma Resch, Gabor Deak, Ivania Pereira and Clemens Vass. e225. Acta Ophthalmologica 2012

Glaucoma: Diagnostic Modalities

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

MEDICAL POLICY. Proprietary Information of Excellus Health Plan, Inc. A nonprofit independent licensee of the BlueCross BlueShield Association

Ganglion cell complex scan in the early prediction of glaucoma

of previous demyelinating optic neuritis

EXPERIMENTAL AND THERAPEUTIC MEDICINE 6: , 2013

Linking structure and function in glaucoma

CLINICAL SCIENCES. Baseline Topographic Optic Disc Measurements Are Associated With the Development of Primary Open-Angle Glaucoma

Reliability analyses of the GDx nerve-fiber analyzer

Advances in OCT Murray Fingeret, OD

The effect of optic disc diameter on vertical cup to disc ratio percentiles in a population based cohort: the Blue Mountains Eye Study

Evaluation of retinal nerve fiber layer thickness parameters in myopic population using scanning laser polarimetry (GDxVCC)

Discriminating between Normal and Glaucoma-Damaged Eyes with the Heidelberg Retina Tomograph 3

Elevated intraocular pressure (IOP) is a major risk factor for

Although measurements of the optic disc and retinal nerve

CLINICAL SCIENCES. Differences in Visual Function and Optic Nerve Structure Between Healthy Eyes of Blacks and Whites

Use of scanning laser ophthalmoscopy to monitor papilloedema in idiopathic intracranial hypertension

T he lamina cribrosa is a sieve-like membrane in the

CLINICAL SCIENCES. Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography

Trans Am Ophthalmol Soc 2015;113:T4[1-10] by the American Ophthalmological Society.

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

Patterns of Subsequent Progression of Localized Retinal Nerve Fiber Layer Defects on Red-free Fundus Photographs in Normal-tension Glaucoma

Diagnostic Accuracy of Scanning Laser Polarimetry with Enhanced versus Variable Corneal Compensation

Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect

Key words: Glaucoma, Imaging, Ophthalmoscopy, Optic neuropathy, Topography

Aging changes of the optic nerve head in relation to open angle glaucoma

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

Diagnostic Accuracy of OCT with a Normative Database to Detect Diffuse Retinal Nerve Fiber Layer Atrophy: Diffuse Atrophy Imaging Study METHODS

To assess the glaucoma diagnostic ability of Fourier Domain Optical Coherence Tomography

T he retinal ganglion cells of different sizes have distinct

Available online at Pelagia Research Library. Advances in Applied Science Research, 2013, 4(6):

Detection of Progressive Retinal Nerve Fiber Layer Loss in Glaucoma Using Scanning Laser Polarimetry with Variable Corneal Compensation

NIH Public Access Author Manuscript Br J Ophthalmol. Author manuscript; available in PMC 2014 November 01.

-Zone Parapapillary Atrophy and the Rate of Retinal Nerve Fiber Layer Thinning in Glaucoma

Scanning Laser Polarimetry in Patients with Acute Attack of Primary Angle Closure

OtticaFisiopatologica

MEDICAL POLICY. Proprietary Information of YourCare Healthcare

Position of retinal blood vessels correlates with retinal nerve fibre layer thickness profiles as measured with GDx VCC and ECC

Early diagnosis of glaucoma

Optic disc damage has been shown to precede visual field

Glaucoma detection using the GDx nerve fiber analyzer and the retinal thickness analyzer

The appearance of the normal optic nerve head (ONH) can

Characterization of Peripapillary Atrophy Using Spectral Domain Optical Coherence Tomography

Assessing the Relationship between Central Corneal Thickness and Retinal Nerve Fiber Layer Thickness in Healthy Subjects

Nobuko Enomoto, Ayako Anraku, Kyoko Ishida, Asuka Takeyama, Fumihiko Yagi, and Goji Tomita

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma

International Journal of Health Sciences and Research ISSN:

The Relationship between Standard Automated Perimetry and GDx VCC Measurements METHODS

THE BASIC PATHOLOGIC CHANGE IN GLAUCOMA IS

Transcription:

Scanning Laser Tomography to Evaluate Optic Discs of Normal Eyes Hiroshi Nakamura,* Toshine Maeda,* Yasuyuki Suzuki and Yoichi Inoue* *Eye Division of Olympia Medical Clinic, Tokyo, Japan; Department of Ophthalmology, University of Tokyo School of Medicine, Tokyo, Japan Purpose: To investigate the effects of age, eye refraction, and disc area on topographic parameters of the optic nerve head in normal volunteers, using the Heidelberg Retina Tomograph. Methods: Seventy-seven eyes of 77 normal volunteers were examined by scanning laser tomography. The topographic parameters analyzed were disc area, cup area, cup/disc area ratio, rim area, cup volume, rim volume, mean cup depth, maximum cup depth, cup shape measure, height variation contour, mean retinal nerve fiber layer thickness (MnRNFLT), and retinal nerve fiber layer (RNFL) cross-section area. The effect of age, refraction, and disc area on each parameter was analyzed by the multiple linear regression model. Results: Significant declines in MnRNFLT and RNFL cross-section area were found with increasing age (P.05). The mean cup depth and maximum cup depth were significantly deeper in myopic subjects (P.05). Large discs had large cup area, cup/disc area ratio, rim area, cup volume, mean cup depth, cup shape measure (P.01), and maximum cup depth (P.05). The MnRNFLT was smaller in large discs (P.01). Rim volume was unaffected by age, refraction, or disc area. Conclusions: The age, refraction, and disc area were related to several optic disc parameters obtained by the Heidelberg Retina Tomograph. Because of these relationships, care should be taken to analyze the appearance of the optic disc on the basis of these parameters in patients with glaucoma or other diseases. Rim volume appears to be a good parameter for evaluating the optic disc without considering age, refraction, or disc area. Jpn J Ophthalmol 1999;43:410 414 1999 Japanese Ophthalmological Society Key Words: Age, multivariate statistical method, normal eye parameters, optic disc, scanning laser tomographic analysis. Introduction Received: July 4, 1998 Correspondence and reprint requests to: Yoichi INOUE, MD, Eye Division of Olympia Medical Clinic, 6-35-3 Jingumae, Shibuya-ku, Tokyo 150-0001, Japan The ophthalmoscopic appearance of the optic disc provides the most reliable evidence of damage in glaucoma patients. Therefore, thorough examination of the optic disc is essential for diagnosis and followup of glaucoma. To provide a basis for evaluating glaucomatous discs, the appearance of normal discs should be analyzed. Numerous studies 1 15 have shown that individual differences, such as age, refractive error, and disc area, affect the size and shape of the optic disc in normal eyes. The results of these studies, however, have not always been in agreement. Recently, the scanning laser ophthalmoscope has been developed for objective, three-dimensional assessments of ocular tissues, such as the retina and optic disc. The Heidelberg Retina Tomograph (HRT, v. 1.11; Heidelberg Engineering, Heidelberg, Germany) is a scanning laser ophthalmoscope with excellent spatial resolution. Various parameters, such as optic disc area, cup area, cup volume, rim area, and rim volume, can be measured accurately with this instrument. In this study, we examined normal optic discs with the HRT and analyzed the effect of age, refractive error, and disc area on disc shape parameters by means of a multivariate analysis. Jpn J Ophthalmol 43, 410 414 (1999) 1999 Japanese Ophthalmological Society 0021-5155/99/$ see front matter Published by Elsevier Science Inc. PII S0021-5155(99)00089-1

H. NAKAMURA ET AL. 411 OPTIC DISC TOMOGRAPHY Materials and Methods Seventy-seven volunteers (77 eyes) were included in this study. All subjects underwent eye examinations and were confirmed to have no ocular disease other than refractive errors and/or mild cataracts. After an informed consent was obtained from each subject by interview, the appearance of the optic disc was evaluated with the HRT. The participants were selected by the following criteria: best corrected visual acuity better than 0.8; refractive error between 5.0 and 5.0 diopters (D); intraocular pressure less than 21 mm Hg in both eyes, as measured with a Goldmann applanation tonometer; a disc area between 1.3 mm 2 and 4.1 mm 2, as measured with the HRT; and no family history of glaucoma (Table 1). Volunteers having tilted discs or discs with oblique insertion were excluded. Qualifying subjects included 24 men and 53 women. Their average age was 56 years (age range, 21 84 years), and the average refractive error was 0.18 D ( 5.0 to 4.13 D). If both eyes of the subject met the above criteria, the left eye was selected because examination of the left eye tended to be better tolerated by most subjects, and the examination results were more satisfactory (Table 1). Measurements with the HRT were performed by three skilled operators after laser stability was achieved. The HRT is a confocal imaging device that uses a diode laser at 670 nm as a light source. A series of 32 confocal images, each 256 256 pixels, is acquired within 1.6 seconds. The field size can vary between 10 10 of retina to 20 20 of retina in 5 increments. In our study, we used the smallest field that included the peripapillary atrophic region for the acquisition of disc images. Each measurement was repeated three times, and the average was calculated. The standard deviation (SD), which indicated the precision of the measurement process, was less than 40 m. The disc contour line was determined by the same operator. The topographic parameters analyzed were disc area (DA), cup area (CA), cup/disc area ratio (C/D), rim area (RA), cup volume (CV), rim volume (RV), man cup depth (MnCD), maximum cup depth (MxCD), cup shape measure (CSM), height variation contour (HVC), mean retinal nerve fiber layer thickness (MnRN- FLT), and retinal nerve fiber layer (RNFL) crosssection area (RCSA). Interrelationships of these parameters to age and refraction were evaluated by calculating Pearson s correlation coefficients. The effect of age, refraction, and DA on each parameter other than DA was analyzed by a multiple linear regression model using age, refraction, and DA as the explanatory variables, and each parameter other than DA as the objective variable. Results The mean values of the parameters obtained by HRT are shown in Table 2, and Pearson s correlation coefficients between the parameters are shown in Table 3. There were 41 statistically significant correlations (P.01) among the parameters in 61 relationships, which indicates that these parameters were strongly interrelated (Table 3). Analysis by multiple linear regression revealed that MnRNFLT and RCSA decreased with age (P.05), and that MnCD and MxCD were significantly deeper in myopic eyes (P.05). Disc area had a strong effect on many parameters: large discs had large CA, C/D, RA, CV, MnCD, CSM (P.01), and MxCD (P.05) (Table 4). Discussion This study showed that several of the optic disc parameters obtained with the HRT were related to age, refraction, and optic disc area. MnRNFLT and RCSA decreased with increasing age; MnCD and MxCD were significantly deeper in myopic eyes; and CA, C/D, Table 1. Summary of Inclusion Criteria Inclusion Criteria 1. Best corrected visual acuity defined as better than 0.8 2. Refractive error between 5.0 and 5.0 diopters 3. Intraocular pressure measured with Goldmann applanation less than 21 mm Hg in both eyes 4. Normal open angle 5. No ocular disease other than refractive errors and mild cataract 6. Disc area measured with HRT between 1.3 mm 2 and 4.1 mm 2 7. Tilted discs and discs with oblique insertion excluded 8. No family history of glaucoma

412 Jpn J Ophthalmol Vol 43: 410 414, 1999 Table 2. Mean Value and Standard Deviation of Each Parameter Obtained by Heidelberg Retina Tomograph Topographic Parameter Mean Value Standard Deviation Disc area (mm 2 ) 2.147 0.500 Cup area (mm 2 ) 0.550 0.416 Cup/disc area ratio 0.238 0.142 Rim area (mm 2 ) 1.596 0.339 Cup volume (mm 3 ) 0.124 0.155 Rim volume (mm 3 ) 0.439 0.149 Mean cup depth (mm) 0.205 0.090 Maximum cup depth (mm) 0.585 0.207 Height variation contour (mm) 0.416 0.107 Cup shape measure 0.199 0.067 Mean RNFL thickness (mm) 0.250 0.080 RNFL cross-section area (mm 2 ) 1.279 0.388 RNFL: retinal nerve fiber layer. RA, CV, MnCD, CSM, and MCD values increased with the disc size. There have been several reports in which the relationship between disc size and refraction, 1 axial length, 2 cupping area, rim area, cup/disc ratio, 1 3 and sex 2,4,5 were investigated. The influence of age on the cup area or nerve fiber layer thickness 1,2,4,6 11 has also been investigated previously, and differences in optic disc structure among races 12,13 have also been reported. However, most of the studies were based on traditional methodologies, such as histological analysis, 5,7,8 evaluation by slit-lamp, 4 6 and analysis of disc photographs. 2,9 Since then, automated instruments that permit threedimensional topographical analysis of the optic nerve and retina, such as the HRT, have been developed. The latest generation of these instruments can provide reproducible measurements of optic disc topography on a point-by-point basis, as well as reproducible calculations of a variety of disc parameters. 16,17 In the present study, we analyzed the three-dimensional structure of normal optic discs by multivariate analysis to evaluate simultaneously the effects of age, refraction, and disc area on the parameters obtained by HRT. The appearance of the optic disc varies among individuals, and, hence, it is very difficult to define a normal optic disc. Jonas and Naumann 18 reported a range of normal disc areas of 1.29 mm 2 4.09 mm 2, based on an analysis of 571 normal eyes. Chihara and Sawada 19 reported that optic discs with oblique insertion frequently had focal nerve fiber layer defects and suggested that there might be some focal abnormality in the structure of such optic discs. Based on these reports, we define a normal disc as Table 3. Pearson s Correlation Coefficients Among Parameters CA C/D RA CV RV MnCD MxCD CSM HVC MnRNFLT RCSA DA 0.736** 0.552** 0.559** 0.597** 0.059 0.464** 0.306* 0.480** 0.043 0.284* 0.065 CA 0.950** 0.150 0.879** 0.441** 0.809** 0.641** 0.652** 0.016 0.446** 0.223 C/D 0.358* 0.813** 0.573** 0.841** 0.717** 0.601** 0.039 0.462** 0.293* CV 0.206 0.626** 0.314* 0.339* 0.097 0.043 0.132 0.368** RV 0.396** 0.845** 0.690** 0.524** 0.058 0.425** 0.277 MnCD 0.297* 0.260 0.160 0.494** 0.701** 0.764** MxCD 0.930** 0.492** 0.228 0.131 0.013 CSM 0.194 0.237 0.032 0.072 HVC 0.129 0.221 0.073 MnRNFLT 0.654** 0.629** RCSA 0.929** CA: cup area. C/D: cup/disc area ratio. RA: rim area. CV: cup volume. RV: rim volume. MnCD: mean cup depth. MxCD: maximum cup depth. CSM: cup shape measure. HVC: height variation contour. MnRNFLT: mean retinal nerve fiber layer thickness. RCSA: RNFL crosssection area. DA: disc area. *P.01. **P.001.

H. NAKAMURA ET AL. 413 OPTIC DISC TOMOGRAPHY Table 4. Effect of Age, Refraction, and Disc Area (DA) Analyzed With Multiple Linear Regression Model Topographic Parameter Explanatory Variables Partial Regression Coefficient Significance Probability Cup area Age 0.002141.2900 Refraction 0.019009.3837 DA** 0.598847.0001 Cup/disc area ratio Age 0.001044.2186 Refraction 0.011453.2114 DA** 0.147501.0001 Rim area Age 0.002139.2906 Refraction 0.018977.3846 DA** 0.401052.0001 Cup volume Age 0.000328.7132 Refraction 0.008805.3620 DA** 0.179038.0001 Rim volume Age 0.001224.2538 Refraction 0.004177.7171 DA 0.023483.5182 Mean cup depth Age 0.000330.5525 Refraction* 0.014061.0210 DA** 0.073354.0002 Maximum cup depth Age 0.000508.7079 Refraction* 0.037007.0133 DA* 0.099738.0331 Cup shape measure Age 0.000708.0907 Refraction 0.000300.9465 DA** 0.063574.0001 Height variation contour Age 0.000299.6970 Refraction 0.008376.3136 DA 0.014566.5769 Mean RNFL thickness Age* 0.001042.0447 Refraction 0.006732.2257 DA** 0.047738.0075 RNFL cross-section area Age* 0.005230.0499 Refraction 0.031241.2738 DA 0.099738.6517 RNFL: retinal nerve fiber layer. *P.05. **P.01. one having a disc area between 1.3 mm 2 and 4.1 mm 2, a refractive error within 5.0 D, and a disc that is not tilted or obliquely inserted. Age significantly affected only the MnRNFLT and RCSA. Other studies 1,4,6 have reported that CA or C/D increases with age, but that the correlation is very weak. Studies that used stereoscopic photographs 2 or image analyzing systems 12 reported no relationship between age and cup or cup/disc ratio, and our results are consistent with these conclusions. There was a report of a histological study that found a significant decline in nerve fiber count with age, 8 and some clinical studies have shown that the thickness of the nerve fiber layer decreases with age. 9 11 Our results are compatible with these reports. Calculations have shown that MnRNFLT decreases 1.0 m each year (partial regression coefficient; 0.001042 in Table 4). Refraction significantly affected MnCD and MxCD. Myopic eyes had deeper MnCD and MxCD. The HRT uses a reference plane and a curved surface for the measurement of these parameters. The curved surface is determined based on the contour line. Therefore, it is possible that tilted discs and oblique insertion, which are frequently observed in high myopia, may affect the curved surface. The result would then be that the calculated MnCD and MxCD would be smaller than their actual values. Because of this possibility, we excluded volunteers with high myopia and oblique insertion from the present study. Myopic eyes actually have deeper cupping than the emmetropic and hyperopic eyes. To our knowledge, there has been only one report on the relationship between refraction and cup depth. 13 Based on an examination of 180 normal subjects with the HRT, including 43 Black, 45 Asian, 48 Hispanic, and 44 White

414 Jpn J Ophthalmol Vol 43: 410 414, 1999 subjects, Tsai et al 13 reported the absence of any significant relationship between refraction and MxCD. The discrepancy between their findings and ours suggests that there may be some racial difference in the relationship, but further investigations are necessary. The disc area was related to several parameters. Large discs had large CA, C/D, RA, CV, MnCD, CSM, and MxCD values, and this finding was consistent with those of many previous studies, 1 3 suggesting that disc area always should be considered in estimating these parameters. Rim volume was the only parameter that was unaffected by age, refraction, and disc area. Caprioli and Miller 3 used a Rodenstock computerized image analysis system in their study and reported that RV was unaffected by disc area. They suggested that further analysis of the effect of age, race, and gender on RV is necessary. All the subjects in our study were Japanese, and refraction was considered simultaneously in the analysis. Accordingly, RV is considered to be a good parameter for evaluating disc shape irrespective of age, refraction, or disc area. In summary, age, refraction, and disc area were related to several optic disc parameters obtained by the HRT. Care should be taken to analyze the appearance of the optic disc on the basis of these parameters in patients with glaucoma or other diseases. RV appears to be a good parameter to evaluate the optic disc shape without considering age, refraction, or disc area. This paper was published in part in the Nippon Ganka Gakkai Zasshi (J Jpn Ophthalmol Soc) 1998;102:378 382. It appears here in a modified form after peer review and editing by the Japanese Journal of Ophthalmology. References 1. Bengtsson B. The alteration and asymmetry of cup and disc diameters. Acta Ophthalmol 1980;58:726 32. 2. Jonas JB, Gusek GC, Naumann GOH. Optic disc, cup and neuroretinal rim size, configuration and correlations in normal eyes. Invest Ophthalmol Vis Sci 1988;29:1151 8. 3. Caprioli J, Miller JM. Optic disc rim area is related to disc size in normal subjects. Arch Ophthalmol 1987;105:1683 5. 4. Schwartz JT, Heuling FH, Garrison RJ. Acquired cupping of the optic nerve head in normotensive eyes. Br J Ophthalmol 1975;59:216 22. 5. Quigley HA, Brown AE, Morrison JD, Drance SM. The size and shape of the optic disc in normal human eyes. Arch Ophthalmol 1990;108:51 7. 6. Carpel EF, Engstrom PF. The normal cup-disc ratio. Am J Ophthalmol 1981;91:588 97. 7. Repka MX, Quigley HA. The effect of age on normal human optic nerve fiber number and diameter. Ophthalmology 1989;96:26 32. 8. Jonas JB, Schmidt AM, Müller-Bergh JA, Schlötzer-Schrehardt UM, Naumann GOH. Human optic nerve fiber count and optic disc size. Invest Ophthalmol Vis Sci 1992;33:2112 8. 9. Jonas JB, Nguyen NX, Naumann GOH. The retinal nerve fiber layer in normal eyes. Ophthalmology 1989;96:627 32. 10. Weinreb RN, Shakiba S, Zangwill L. Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. Am J Ophthalmol 1995;119:627 36. 11. Chi QM, Tomita G, Inazumi K, Hayakawa T, Ido T, Kitazawa Y. Evaluation of the effect of aging on the retinal nerve fiber layer thickness using scanning laser polarimetry. J Glaucoma 1995;4:406 13. 12. Varma R, Tielsch JM, Quigley HA, et al. Race-, age-, gender-, and refractive error-related differences in the normal optic disc. Arch Ophthalmol 1994;112:1068 76. 13. Tsai CS, Zangwill L, Gonzalez C, et al. Ethnic differences in optic nerve head topography. J Glaucoma 1995;4:248 57. 14. Tsai CS, Ritch R, Shin DH, Wan JY, Chi T. Age-related decline of disc rim area in visually normal subjects. Ophthalmology 1992;99:29 35. 15. Sumi I, Matsumoto S, Yoshikawa K, Andou N. Optic disc parameters in visually normal subjects. Atarashii Ganka (J Eye) 1997;14:613 5. 16. Kruse FE, Burk ROW, Volcher HE, Zinser G, Harbarth U. Reproducibility of topographic measurements of the optic nerve head with laser tomographic scanning. Ophthalmology 1989;96:1320 4. 17. Yoshikawa K, Ujikawa M, Iijima T, Azuhata S, Inoue Y. Reproducibility of the topographic parameters of the optic disc with the scanning laser tomograph. Nippon Ganka Gakkai Zasshi (J Jpn Ophthalmol Soc) 1995;99:469 73. 18. Jonas JB, Naumann GOH. The optic nerve; its embryology, histology, and morphology. In: Varna R, ed. The optic nerve in glaucoma. Philadelphia: Lippincott, 1993:3 26. 19. Chihara E, Sawada A. Atypical nerve fiber layer defects in high myopes with high-tension glaucoma. Arch Ophthalmol 1990;108:228 32.