Latex Free. An affordable, easy to use, high density, small volume nebulizer with a revolutionary breath enhanced design!

Similar documents
Latex Free. An affordable, easy to use, high density, small volume nebulizer with a breath enhanced design! Breath Enhanced High Density Jet Nebulizer

NebuTech nebulizer from Salter. Striving to be #1 IN PATIENT SATISFACTION. To help you and your patients. easy. breathe

experiences that matter

Nebulizers. Small Volume Nebulizers

Misty Max 10 nebulizer

EMERGENCY AIRWAY MANAGEMENT SOLUTIONS

InspiraChamber System From Salter. One system for all your patients NEW

15 cm Reservoir Tubing. 210 cm Tubing

Respiratory Drug Delivery. Be inspired. Nebulizer and compressor catalog

Invacare Aerosol Products. Stratos Aerosol Compressors Nebulizers Asthma Management

8/13/11. RSPT 1410 Humidity & Aerosol Therapy Part 3. Humidification Equipment. Aerosol Therapy

NEBULIZERS, METERED DOSE INHALERS, AND DRY POWDER INHALERS

...Porta-neb matched systems from Respironics (UK)

MEET THE DRIVING FORCE IN NEBULIZER THERAPY... Matched Nebulizer Compressor System

Effective Date: August 31, 2006 SUBJECT: CARE AND USE OF NEBULIZER AND INTERMITTENT POSITIVE PRESSURE BREATHING DEVICE

DeVilbiss. Aerosol.

Redefining Continuous Aerosol Drug Delivery 2015 PM223

Redefining Continuous Aerosol Drug Delivery PM223

Helping you stay in control. Respiratory Drug Delivery product catalogue

This letter is to notify you of recent changes to the PULMOZYME product monograph. Please note, additions/changes have been highlighted in yellow.

PORTABLE COMPRESSOR NEBULIZER Guidebook & Manual Reorder No. 5606

Small Volume Nebulizer Treatment (Hand-Held)

English. Fealite Nasal Pillows System. User Manual

acapella vibratory PEP Therapy System Maximizing Therapy Effectiveness, Empowering Patient Compliance

Computational Fluid Dynamics Modeling of Amsino OneMask Oxygen Mask

Compressor Nebulizer. Guidebook

Home Care ecatalog. When Your Care Is Critical. westmedinc.com

PARI Product Catalog

Introduc)on & Background

Our Family of Sleep Diagnostic Products

2008 IPAC-RS Conference Doing the Right Thing Science, Quality and Patient Focus

Rush University, College of Health Sciences

TOWN OF FAIRFIELD HEALTH DEPARTMENT PUBLIC HEALTH NURSING

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual

Compressor Nebulizer. Guidebook

Respiratory Care in PICU Aerosol Therapy ส พ ชชา ชา แสงโขต โรงพยาบาลสมเด จพระป นเกล า

Activity 1: Respiratory System Lab

Using an Inhaler and Nebulizer

Compressor Nebulizer. Model UN-014

Compressor Nebulizer System

Neonatal and Pediatric Securement From Salter

OG TAL ODUCT CA PR e e HEALTH

Medescan Nebuliser Med - S600A Instructions Manual

Biology 236 Spring 2002 Campos/Wurdak/Fahey Laboratory 4. Cardiovascular and Respiratory Adjustments to Stationary Bicycle Exercise.

Appendix M: Device Technique

The respiratory system structure and function

Aerosol Delivery Devices

AEROSOL THERAPY: THE PRACTICALITIES

Breezhaler. Open to see clear capsule. How do I use my Breezhaler? Care of my Breezhaler

ISO INTERNATIONAL STANDARD. Anaesthetic and respiratory equipment Nebulizing systems and components

Metered Dose Inhalers with Valved Holding Chamber: A Pediatric Hospital Experience

It is recommended that a mask and protective eyewear be worn when providing care to a patient with a cough

1 Chapter 13 Respiratory Emergencies 2 Respiratory Distress Patients often complain about. Shortness of breath Symptom of many different Cause can be

Unit 5 Humidity/Aerosol Generators

Care and Use of Nebulisers

61a A&P: Respiratory System!

Pediatrics in mechanical ventilation

Chapter 10 The Respiratory System

Respiratory. Nebulizers Allegiance SUNRISE MEDICAL. BGH w/7 (84 ) tubing and mouthpiece BGH w/7 (84 ) tubing, mouthpiece, 6 flextube

Salter Labs Product Catalog. Distinct products. experiences that matter

Unit 6.1 Test Review THE NERVOUS, INTEGUMENTARY, CIRCULATORY, AND RESPIRATORY SYSTEMS

Pulmo Waves Device for respiratory physiotherapy

Blow-by as Potential Therapy for Uncooperative Children: An In-Vitro Study. Mohamed Mohsen Mansour MD and Gerald C Smaldone MD PhD

Helping to protect you from exposure to hazardous drugs

Portable Equine Nebuliser System. User Manual

Inhaler Devices. Ask the patient/carer to demonstrate the technique and correct accordingly at every opportunity.

INSTRUCTION MANUAL. Compressor Nebulizer System NE-C25

Index TEMPERATURE BABY CARE... 9

CARDIOVASCULAR AND RESPIRATORY SYSTEMS

#7 - Respiratory System

Chapter 10. The Respiratory System Exchange of Gases. Copyright 2009 Pearson Education, Inc.

-Rachel Naomi Remen. Respiratory System 1

61a A&P: Respiratory System!

0086 DECLARATION OF CONFORMITY Salter Labs

In Vitro Evaluation of Positive Expiratory Pressure Devices Attached to Nebulizers

How to Use Inhaled Medications for Asthma and COPD

I. Subject: Continuous Aerosolization of Bronchodilators

I. Subject: Medication Delivery by Metered Dose Inhaler (MDI)

Citation for published version (APA): Westerman, E. M. (2009). Studies on antibiotic aerosols for inhalation in cystic fibrosis s.n.

Circulatory System. and. Respiratory System. Ari Min, Yerim Lee and Min Ji Song THE HEART LUNGS. Monday, May 23, 2011

Inhalation Therapy. Inhalation Therapy

My CoughAssist. A patient guide to CoughAssist E70

LUNGS. Requirements of a Respiratory System

Meeting the big challenge of little faces. Philips Respironics pediatric patient interfaces for noninvasive ventilation

NomoLine No-moisture sampling lines for intubated and non-intubated patients in low- and high-humidity applications

Cleaning and Care Instructions

Anaesthetic and respiratory equipment Nebulizing systems and components

TRUSTED SOLUTIONS FOR SIMPLIFIED PATIENT CARE. Shiley Tracheostomy Product Guide GettyImages

Supporting information leaflet (6): Chest Physiotherapy: Lung Volume Recruitment Techniques and Cough Augmentation (Assisted Cough Techniques)

An update on inhalation devices

Aerosol and Airway Clearance Therapies: Challenges and Opportunities. Growth of the Medicare. Aerosol and ACT Therapies Terry L. Forrette, M.H.

The Collapsible Chamber

Perceptual reasons for resistance to change in the emergency department use of holding chambers for children with asthma

Anatomy & Physiology 2 Canale. Respiratory System: Exchange of Gases

Digital MacroView Otoscope

MEDIUM-FLOW PNEUMOTACH TRANSDUCER

Choice of Nebulizer for Inhaled Tobramycin Treatment in Cystic Fibrosis

Rhino Clear Sprint Atomizer

Transcription:

Latex Free Breath Enhanced High Density Jet Nebulizer The NebuTech HDN nebulizer, a revolutionary breath enhanced design, by Salter Labs is quickly becoming the product of choice for caregivers and patients alike. This unique nebulizer incorporates patented design elements to enhance the concentration or density of medication delivered per breath with less waste then conventional nebulizers. The NebuTech HDN is an affordable, easy to use, small volume nebulizer which will provide consistent results time after time. NebuTech HDN 8660 Features: Breath Enhanced Design Faster Treatment Times Reduced Medication Waste High Aerosol Output Patented Bolus Design Ease of use Consistent Reliable Performance An affordable, easy to use, high density, small volume nebulizer with a revolutionary breath enhanced design! Quality care begins with quality products.

Delivery of aerosol early in inspiration puts the aerosol at the (front end) of the breath for deeper penetration 5 NebuTech HDN is a jet driven, breath enhanced, small volume, high density medication nebulizer. It utilizes a patented design and incorporates a combination of unique features to produce a dense 50cc aerosol bolus. This bolus is available for delivery during the crucial first one third of every breath. Eighty percent of the particles in the bolus are in a respirable range of 1.0-5.0µm and MMAD of 1.3µm. 1,3 (FIG.2,7) DEPOSITION OF AEROSOL 10.0µm Nasal Cavity 10.0µm Pharynx 10.0µm Larynx 6.0µm Trachea 2.0µm - 5.0µm Primary Bronchi 0.5µm - 2.0µm Lung FIG.1 FLOW RATE (L/min.) PARTICLE SIZE (microns) 0.14 0.23 0.40 0.62 1.30 2.30 3.20 4.60 6.50 9.20 MMAD 4 3% 5% 10% 21% 25% 26% 6% 2% 1% 2% 1.30 6 4% 9% 15% 26% 25% 16% 2% 1% 2% 1% 1.10 7 4% 11% 16% 27% 22% 14% 2% 1% 1% 1% 1.10 8 4% 12% 17% 30% 20% 12% 2% 0% 1% 1% 1.00 10 4% 14% 19% 31% 17% 10% 1% 1% 1% 1%.98 FIG.2 The colored portion of the particle size chart shows the respirable dose in the 1.0-5.0µm size and MMAD delivered by the NebuTech HDN NebuTech HDN will produce high output aerosol in MMAD of 1.0 to 1.3µm (FIG.2) and deliver a larger respirable dose to the patients lungs (FIG.6) in a short amount of treatment time (FIG.3). The valved tower chamber prepares and holds the dense 50cc bolus ready for the beginning of each inspiration. It is delivered in the first third of every breath, which ensures delivery to the lung and primary bronchi. This may benefit the patient by providing fast relief and can encourage improved patient compliance with shorter aerosol treatment times. A shorter treatment is important to a patient and encourages them to be more compliant to the aerosol regime. DOSE DELIVERED TIME (min./sec.) MAKE MODEL WALL 50 PSI COMPRESSOR Salter Labs 8660 reuse. 3:24 5:13 Salter Labs 8900 disp 3:55 6:10 Pari LC Plus 3:40 6:38 Intersurgical HOT Top 4:15 6:20 Respironics Sidestream 4:50 5:42 WestMed Vix One 6:47 7:20 FIG.3 3cc normal saline until first sputter +1 sec. of complete break in aerosol stream. Data on file. Nebulization time is important for patient compliance in the outpatient setting and clinician supervision for hospitalization patients. A short nebulization time that delivers an effective dose is desirable. 3

The most important characteristic of nebulizer performance is the respirable dose provided for the patient. 1 The mechanics of breathing dictate that the denser an aerosol is in the first one third of an inspiration the higher the concentration of a drug will reach the area of the lung where it can be most effective. If all nebulizers delivered their entire aerosol in the respirable range there would still be a difference from one device to another in the amount of dose delivered. Nebulizers which are open to the atmosphere or are unable to recycle non-respirable particles and do not have the capacity to retain a 50cc bolus of dense aerosol can not deliver the same level of aerosol as the NebuTech HDN nebulizer. Efficiency of the design with valves and a bolus chamber can be seen in (Fig. 4,6,7). The ability to deliver repeatable precharged aerosol at the onset of each inspiration provides a larger dose per breath which results in substantial benefit to the patient as well as the hospital with improved compliance and resources utilization. INHALED RESPIRABLE MASS (mg/breath) 7 3ml albuterol 20 breaths Albuterol (mg/breath) FIG.6 0.100 0.090 0.080 0.070 0.060 0.050 0.040 0.030 0.020 0.010 0.000 0.082 Respirable Dose (0.5 to 5.0µm) / Breath (Wall) Respirable Dose (0.5 to 5.0µm) / Breath (Compressor) 0.060 Salter 8660 0.035 0.030 *LC Plus 0.010 0.016 *Sidestream *Inhaled mass values reflect concentration of Albuterol used for product comparison purpose and does not imply therapeutic dose to the patient. Simulator setting at 15 BPM, 500ml tidal volume OUTPUT COMPARISON ML/MIN 7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 FIG.4 0.48 0.52 Salter 8660 0.27 0.24 *Used their respective compressors. All others used Salter AIRE Plus. 0.36 0.39 Wall 50psi 7LPM Compressor 0.24 0.36 0.20 0.20 *LC Plus *Sidestream HOT Top Vix One Clearly, the ability to produce High Density Aerosol with a large RF (respirable fraction) during the inspiratory phase is the basic principle. 1 The NebuTech HDN delivers a high aerosol with an MMAD of 1.3µm. Aerosol output (Fig. 4) of a nebulizer is simply the volume of aerosol that leaves the device over time (m;/min). It is important to remember that output alone does not represent what is the available to the patient. Only respirable particles which are delivered to the site where pharmacologic action takes place, should be counted as being the effective output of a device. Effective aerosol therapy depends on delivering a high output of aerosol in the respirable range. Patients treated with Nebutech HDN nebulizers demonstrated significant decreases of stay, tot

Effective Targeting of the Bronchial region can only be achieved with Bolus inhalations. 1 In our Emergency Department study, nebulizer brand utilized to treat pediatric asthma appear to make an impact on both clinical and financial outcome. 4 Patients requiring hospitalization in 27 monitored ED facilities from Oct. 1996 to Oct. 1997. had average stays lasting 3.8 days at an average cost of $3,102.53. The majority of the cost was directly associated with nursing, respiratory care and medication. The patients which required hospitalization exceeded DRG by $500.00! NebuTech HDN delivers a larger dose quicker and can bring relief faster...it can save time and money in labor and medicine...there are no unusual cost of new protocols or lengthy staff education...it just works better and faster. BREATHING CYCLE Nebutech HDN 8660 Particle Density 0 1 2 3 4 Time *VA Inhalation Exhalation A major benefit for a respiratory care, emergency department or general floor treatments is the opportunity for substantial savings in FTE, full time equivalent, as well as enable better utilization of human resources. It may allow existing staff to perform additional or new tasks. One institution discovered substantial savings in their emergency department through the faster treatment time and patients responding more quickly to the aerosol medication delivered. This led to fewer ED admissions, reduced numbers of treatments and higher respiratory staff efficiency and productivity. FIG.7 During exhalation the NebuTech HDN tower acts as a reservoir capturing a 50cc bolus of dense aerosol particles. Eighty percent of these particles are in the respirable range. They are delivered to the lungs in the critical first one third of inhalation of which the alveolar volume is composed. Aerosol production and delivery continues throughout the inspiratory cycle. During the exhalation cycle aerosol precharges the 50cc tower with a new bolus ready for the next inspiration and will be delivered during the critical first one third of each breath. The versatility of the NebuTech HDN allows a clinician to select from several delivery modality options, including a mouthpiece or face masks in an conventional aerosol mask style or special valved configurations in adult and pediatric sizes. al treatment times, admission rates and mean number of treatments. 4

The one way valve on top opens to allow a breath enhanced inspiration. It will not close until exhalation begins. If a face mask is employed this valve is removed from the top and inserted where the mouthpiece fits. It prevents medication from escaping into the room in either position. ROOM AIR If preparing to use a mask the one way valve is easy to remove. Just twist and lift up, then place it in the mouthpiece port. Replace the top port with the face mask. MEDICATED AEROSOL EXHALATION The Mouthpiece has smooth rounded tip with no sharp edges. It is comfortable for pediatrics, adults and edentulous patients. The exhalation port one way tricuspid shaped valve opens only during exhalation. It remains closed during inspiration so the aerosol dose will not be diluted with air which has not passed through the reservoir tower. An easy 1/4 turn is all it takes to remove or add the optional exhalation filter. The mouthpiece attaches at a natural ergonomic angle. It is easy to hold the Nebulizer in a natural comfortable position while taking an aerosol treatment. NEBUTECH HDN VERSATILITY The versatility of the NebuTech HDN allows a clinician to select from several delivery modality options, including Anti drool feature incorporated to maintain integrity of the medication. It takes only a moment to remove and empty out any saliva that has accumulated. a mouthpiece or face masks in an conventional aerosol mask style or special valved configurations in adult and pediatric sizes. The reservoir tower directs incoming air to the bottom where it is joined with aerosolized medication and holds as a Bolus until inspiration begins. 50PSI WALL SOURCE AIR or COMPRESSOR AIR FIG.5 50cc Bolus 5cc Diluent & Medication The bright green cone creates a capillary action and allows operation at virtually any angle. The scalloped cuff provides stability and makes it easier to grip the connecting tubing end when connecting or disconnecting to a gas power source. The clear medication cup Holds 5cc diluent and medication. A graduated marker is clearly visible. Only 1/4 turn easily removes or replaces the cup with a positive leak proof seal. Nebutech HDN 8660 Pediatric Mask 1120 Adult Mask 8100

Features at a Glance Anti-Drool Feature Virtually Any Angle Dishwasher Safe 50cc Bolus Breath Enhanced Mouthpiece & Reservoir Tube Valved Mouthpiece Optional Valved Pediatric Mask Optional Valved Adult Mask Optional Adult Mask Optional Pediatric Mask PEP Attachment Works with Compressor Environmental Filter Reusable Single Patient Use High Density NebuTech HDN 8960 NebuTech HDN 8660 Salter Labs 8900 Series SVN Ordering Information NebuTech HDN * High Density Nebulizer Units per Case Reusable # Disposable # NebuTech HDN, mouthpiece, Salter Safety PEP Device, nose clip and manometer. 10 or 25 8672 N/A NebuTech HDN and mouthpiece only. 10 or 50 8661 8961 NebuTech HDN, mouthpiece and (disposable) 7 supply tube. 10 or 50 8660 8960 NebuTech HDN, mouthpiece, filter and (disposable ) 7 supply tube. 10 or 50 8682 8982 NebuTech HDN, mouthpiece and (disposable) 7 supply tube with female thread grip connector 10 or 50 8660TG 8960TG NebuTech HDN, Adult aerosol Mask, elastic strap style, 7 supply tube 10 or 50 N/A 8984 NebuTech HDN, Adult aerosol Mask with VADS,valved aerosol delivery system, 7 supply tube 10 or 50 N/A 8987 NebuTech HDN, Pediatric aerosol mask, elastic strap style, 7 supply tube 10 or 50 N/A 8966 NebuTech HDN, Pediatric aerosol Mask with VADS,valved aerosol delivery system, 7 supply tube 10 or 50 N/A 8967 Mouthpiece, with exhalation valve 10 or 50 8670 8970 8900 Series Nebulizer with anti-drool T, mouthpiece,6 reservoir tube and 7 supply tube 50 N/A 8900 Salter AIRE Plus Simply select the combination you want and add the four digit part number to the compressor part number Salter AIRE Plus 115V portable treatment compressor with your selection of a nebulizer with, mouthpiece or mask. Salter AIRE Plus 230V European Compressor with CEE 7-16 ungrounded plug (Europlug) Salter AIRE Plus 230V United Kingdom Compressor with BS 1363 grounded plug. Part Number 8350 + mask or mouthpiece p/n 8352 + mask or mouthpiece p/n 8353 + mask or mouthpiece p/n FOOTNOTE REFERENCE LIST: 1. Heyder J ; Deposition of Inhaled Particles in the Human Respiratory Tract and Consequences for Regional Targeting in Respiratory Drug delivery. Am Thorc Soc. 2004 vol 1, 315-320. 2. Leung K, Louca E, Coates A ; Comparison of Breath-Enhanced to Breath-Actuated Nebulizers for Rate, Consistency and Efficiency. Chest 2004, 126/5/November. 3. Hess R ; Resp Care 2000, June, 45(6) 609-610. 4. Myers TR, Chatburn R, Rogers M, Richardson K, Kerscmar C; Does nebulizer Brand make a Clinical Difference in the Emergency Room Management of Pediatric Asthma. Resp Care 1999,44 (10) 1278 5. Consensus Statement; Aerosols and Delivery Devices. Resp Care 2000, 45 (6) 589 6. Dunne PJ; Novel Designs for nebulizer Technology Improve Effectiveness and Efficiency. Adv. For Mgrs Resp Care 2003, Jan 12-16 7. Data on file. Arvin, CA ISO 13485 Authorized Representative in the E.U.: MT Promedt Consulting GmbH Altenhofstrasse 80 D-66386 St. Ingbert Germany Printed in U.S.A. Copyright 2009 Salter Labs Rev January 2011 SLML 60 U.S. Patent No. RE33,717; 5,584,285; 6,176,234 Other U.S. and Worldwide patents pending 100 West Sycamore Road Arvin, CA 93203 Phone: 661.854.3166 1-800.421.0024 1.800.235.4203 Fax: 661.854.3850 Toll Free Fax: 1.800.628.4690 Email: salterlabs@us.salterlabs.com www.salterlabs.com