Doc no: IFU/CPL Issue date: Rev no: 00 Rev date: 1

Similar documents
Doc no: IFU/CC Issue date: Rev no: 04 Rev date:

Duracryl sutures should be selected and implanted depending on the patient condition, surgical experience, suturing technique and wound size.

RD180 SP TECHNOLOGY GUIDE READ THIS PRODUCT INSERT THOROUGHLY BEFORE USE

Desara TV and Desara Blue TV

PLAIN GUT PLAIN GUT. Description. Characteristics. Indications. Contraindications. Actions. Tensile Strength. Absorption. Sterilization.

Many factors may affect the rate of tensile strength loss. These include: Type of suture Presence of infection Tissue sites

INSTRUCTIONS FOR USE FOR:

Desara and Desara Blue

Initial placement 24FR Pull PEG kit REORDER NO:

For use by an Accredited Orthopaedic Surgeon only

PRO-DENSE Bone Graft Substitute The following languages are included in this packet:

Single Use Curlew TM Multiple Biopsy Forceps

Technique Guide KISSloc Suture System

PRO-DENSE BONE GRAFT SUBSTITUTE

Surgical Protocol written by Keith Lawhorn, M.D.

Precautionary Statement ( )

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

Aesculap CranioFix absorbable

EVOLVE TRIAD BONE SCREWS

Peel-Apart Percutaneous Introducer Kits for

The following languages are included in this packet:

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

Titanium Wire With Barb and Needle

Technique Guide Small Bone Fusion System

Integra Flowable Wound Matrix

Initial placement 20FR Guidewire PEG kit REORDER NO:

Visit Linvatec.com today to learn more. Surgical Technique: Sequential Meniscal Running Stitch

BIOKNOTLESSRC ROTATOR CUFF REPAIR SUTURE ANCHOR SURGICAL TECHNIQUE. Surgical Technique for Arthroscopic Rotator Cuff Repair. Raymond Thal, M.D.

Integra. TenoGlide Tendon Protector Sheet SURGICAL TECHNIQUE

SYNTHECEL Dura Repair. Assurance and Versatility for Dura Reconstruction.

Helicobacter pylori Antigen Test

SIDEKICK EZ FRAME EXTERNAL FIXATION SYSTEM The following languages are included in this packet:

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Instructions for Use. Wright Medical Technology 1023 Cherry Road Memphis, TN USA

Device Preparation (all steps to be performed per standard interventional technique)

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6

Prof Oluwadiya KS FMCS(orthop)

Desara Blue OV D I. Sling for Female Stress Urinary Incontinence. Instructions For Use

HeliMEND Advanced. Absorbable Collagen Membrane. Instructions for Use

OptiFix Absorbable Fixation System

CELLPLEX TCP SYNTHETIC CANCELLOUS BONE

Instructions for use for Bone Plates, Bone Screws, Intramedullary Nails, Pins and Wires

Echo PS Positioning System with Ventralight ST Mesh or Composix L/P Mesh

INSTRUCTIONS FOR USE AND CARE

Lapidus Arthrodesis System Instructions for Use

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

Metallic Internal Fixation Devices The following languages are included in this packet:

CHANGING THE WAY YOU LOOK AT THINGS

MULTIFIX S Knotless Implants

Technique Guide. Rapid IMF Device. Temporary mandibular fixation device.

DARCO MIS FOREFOOT SCREW

EVOLVE TRIAD SYSTEM

The following languages are included in this packet:

3M Tegaderm CHG Chlorhexidine Gluconate I.V. Securement Dressing Description 3M Tegaderm CHG Chlorhexidine Gluconate I.V. Securement Dressing is used

Application Guide for Full-Thickness Wounds

Yasargil Permanent Aneurysm Clips

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

DISTAL RADIUS. Instructions for Use

Device Technical File

Customized Cranial and Craniofacial Implants. Instructions For Use. 7000revD_Instructions_For_Use. Page 1 of 8

Passer. Sterile. D i. Do Not PASSER DESCRIPTION. The Ceterix. Page 1

DMF Page 63. Description

NovoSorb BTM. A unique synthetic biodegradable wound scaffold. Regenerating tissue. Changing lives.

Bard CapSure. Technique Guide. Permanent Fixation System SOFT TISSUE REPAIR. Laparoscopic Inguinal, Open and Laparoscopic Ventral Hernia Repair

TissueMend. Arthroscopic Surgical Technique. Arthroscopic Insertion of a Biologic Rotator Cuff Tissue Augment After Rotator Cuff Repair

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE. Rx only REF LOT. STERILE EO Sterilized using ethylene oxide

Safety Committee Prototypical Safety Program Manual

Flexible Fragment Fixation. Surgical Technique

EXTERNAL FIXATION SYSTEMS The following languages are included in this packet:

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE REF LOT STERILE EO. Manufactured for: 824 Twelfth Avenue Bethlehem, PA

Hepatitis C Virus (HCV) Antibody Test

Alamo C. Cervical Interbody System Surgical Technique. An Alliance Partners Company

eptfe Vascular Graft Instructions for Use

Positioning System. Laparoscopic ventral hernia repair KEY BENEFITS SOFT TISSUE REPAIR

Chlamydia trachomatis (CHLa)Test Kit

Revision A Date:

The Ceterix NovoStitch Disposable Suture Passer. Do Not Reuse

St. Jude Medical 8-Channel Adapter. Clinician's Manual

OBSOLETE. Visit for the latest version. Ankle Plating System 3 PKGI-79-B EFFECTIVE

Instructions for use. Radiopaque bone cement

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017

ORTHOLOC 3Di PLANTAR LAPIDUS PLATE

BIOFOAM BONE WEDGE

Jadelle Contraceptive Implants up to 5 years Insertion and Removal

METATARSAL DECOMPRESSION IMPLANT (MDI) SYSTEM

Ponsky * PEG Safety System - "Pull" Bard * PEG Safety System - "Guidewire" Information for Use

JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation. Surgical Technique

Headless Compession Screw 2.5 / 3.0

ENDO-FUSE INTRA-OSSEOUS FUSION SYSTEM The following languages are included in this packet:

Headless Compession Screw 4.5 / 6.5 SURGICAL TECHNIQUE. Titanium or Stainless Steel. Cannulated Headless Design. Multiple Thread Options.

MICA SCREWS For additional information and translations please contact the manufacturer or local distributor.

JRI Thompson Hemiarthroplasty

KASM Knee Articulating Spacer Mold. Surgical Summary

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

low ProfIle neuro PlaTIng system

Low Profile Neuro Plating System. Surgical Technique

Transcription:

FUTURA SURGICARE PVT LTD INSTRUCTION FOR USE Brand name: PROGUT Material: Catgut Plain. Absorbable surgical suture U.S.P Description: Progut surgical catgut suture is a sterile absorbable suture composed of purified connective tissue (collagen) derived from the sub mucosal layer of sheep (Ovine) intestine. Progut is available in a range of gauge sizes and length, non needled or attached to stainless steel needles of varying types, sizes and shapes. The needles are attached permanently to the suture. Entire details of the product range are available in the catalogue. Progut complies with the requirements of the United States Pharmacopoeia monograph for Absorbable surgical suture. The surgical suture is packed in a sterilizing fluid which contains isopropanol, purified water and ethylene oxide. Indications: Progut is for use in general soft tissue approximation and/or ligation. Mode of action Progut suture elicits a minimal tissue reaction and in growth of fibrous connective tissue. Absorption of bio absorbable suture occurs by enzymatic action: beginning with loss of tensile strength with loss of mass. The suture retains approx 50% of the tensile strength within 15 17 days when implanted in rat and the suture is essentially absorbed within 80 days. Contraindications: These sutures, being absorbable, should not be used where extended approximation of tissues under stress is required. Progut is contraindicated for use in cardiovascular and neurological tissues. Progut is contraindicated in patients with known sensitive or allergies to collagen since Progut is a collagen based which has been treated with chromic salt solutions. Product should not be used in the infected tissue and where prolonged tissue approximation is required. Application: Sutures should be selected and implanted depending on the patient condition, surgical experience, surgical technique and wound size. Performance: Doc no: IFU/CPL Issue date: 27.5.2016 Rev no: 00 Rev date: 1

When Progut suture is implanted, a moderate tissue inflammation occurs, this is a characteristic of a foreign body response. Loss of tensile strength and loss of suture mass follows as the proteolytic enzymatic digestive process resorbs the surgical catgut. Infection: Progut is absorbed more rapidly in infected tissues than in non infected tissues. Tissue sites: Progut is absorbed more rapidly in tissues where increased levels of proteolytic enzymes are present, as in the secretions from the stomach, cervix and vagina. Warnings/ precautions/ interaction. Users should be familiar with handling and knotting techniques involving catgut sutures before using this material for wound closure, since the risk of wound dehiscence may vary with the site of application and the type of suture used. Surgeons should consider the in vivo performance of the catgut when selecting this suture. This suture may be inappropriate in elderly, malnourished patients or in patients suffering from conditions which may delay wound healing. As an absorbable suture, Progut acts transiently as a foreign body. As with any foreign body, prolonged contact of any suture with salt solutions, such as those found in urinary or bilary tracts may result in calculus formation. Acceptable surgical practice should be followed for the management of contaminated of infected wound. As with all absorbable suture material, the use of supplemental non absorbable sutures should be followed for the management of contaminated or infected wounds, expansion, stretching or distension or which may require additional support. Some patients may be hypersensitive to collagen and may develop immune reaction. Under some circumstances, notably orthopedic procedures, immobilizations of the joints by external support may be employed at the discretion of the surgeons. Consideration should be taken in the use of absorbable sutures in tissue with poor blood supply as suture extrusion and delayed absorption may occur. In handling catgut suture care should be taken to avoid damage. Avoid crushing or crimping damage due to application of surgical instrument such as forceps or needle holders. Adequate knot security requires the standard surgical technique of flat and square ties with additional throws as indicated by surgical circumstances and the experience of the surgeon. Avoid unnecessary tension while when Doc no: IFU/CPL Issue date: 27.5.2016 Rev no: 00 Rev date: 2

running down the knots, to reduce the occurrence or surface fraying and weakening of the strand. Care should be taken when opening the pack as it contains sterilizing fluid. Care should be taken to avoid damage while handling the needles. Grasp the needle in an area one third to one half of the distance from the attachment end to the point. Grasping in the point area could impair the penetration, performance and cause fracture of the needle. Grasping the butt or the attachment of the needle may cause needle bending or breakage. Reshaping the needles may cause them to loose the strength and be less resistant to bending and breaking. Users should exercise caution when handling surgical needles to avoid inadvertent needle stick injury. Discard the used needles in sharp containers. Adverse reaction: Adverse reactions associated with the use of the device include allergic response in certain patients, transient local irritation at the wound site, followed by moderate transient inflammatory foreign body response. Like all foreign body catgut may enhance an existing reaction. Sterility: Progut sutures are sterilized by ethylene oxide. Don t re sterilize! Do not use if the pack is opened or damaged! Discard unused sutures! Storage Recommended storage condition 10 35 C, away from moisture and direct heat. Do not use after expiry date Disposal: Discard used sutures and needles contaminated with blood in the container meant infectious waste. Unused expired pouches should be incinerated. Technique for opening the over wrap: 1. The scrub nurse should hold the sterile pack in left hand with the color coded top facing her. The notch will be located at the top right. Doc no: IFU/CPL Issue date: 27.5.2016 Rev no: 00 Rev date: 3

2. Then with the help of sterilized gloved hand or sterilized forceps pull the paper folder till the needle is visible. For non needled suture, pull out the entire paper folder from the pack, open the folder and retrieve the suture. 3. Again with the help of sterilized gloved hand or sterilized forceps grasp the needle which is visible. Pull the needle to remove the suture from the folder. Symbols used on labels: Do not reuse Batch number Date of manufacture Date of expiry Sterilized by ethylene oxide Registered Avoid Moisture Avoid direct sunlight Temperature limitation Do not resterilize Do not use if package is damaged Consult instructions for use Doc no: IFU/CPL Issue date: 27.5.2016 Rev no: 00 Rev date: 4

Manufacturer: Futura Surgicare Pvt Ltd, 86/C2, 3 rd Main, 2 nd Stage, Yeshwanthpur Industrial Suburb, Bangalore 560022, India. Mfg Lic No: KTK/28/273/1995 Doc no: IFU/CPL Issue date: 27.5.2016 Rev no: 00 Rev date: 5