Comparative Bioavailabilitv Studv of Two Brands of Terbutaline Sulphate Tablets in Healthy Human Volunteers

Similar documents
Bioequivalence Studies of Two Formulations of Famciclovir Tablets by HPLC Method

J Pharm Sci Bioscientific Res (4): ISSN NO

Available online at Scholars Research Library

Determination of propranolol in dog plasma by HPLC method

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

Available online Research Article

High Performance Liquid Chromatographic Determination of Cyclooxygenase II Inhibitor Rofecoxib in Rat and Human Plasma

Hyderabad, India. Department of Pharmaceutical Chemistry, Glocal University, Saharanpur, India.

Validated RP- HPLC Method for the Quantitative Estimation of Valsartan in Bulk and Pharmaceutical Dosage Forms

Scholars Research Library. Der Pharmacia Lettre, 2015, 7 (5):44-49 (

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

Scholars Research Library. Der Pharmacia Lettre, 2016, 8 (6): (

REVERSE PHASE HPLC METHOD FOR THE ANALYSIS OF ALFUZOSIN HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORMS

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS

This revision also necessitates a change in the table numbering in the test for Organic Impurities.

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

L. Sriphong, A. Chaidedgumjorn, and K. Chaisuroj

ISSN: ; CODEN ECJHAO E-Journal of Chemistry 2011, 8(3),

ISSN (Print)

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

Department of Pharmaceutical Analysis, Amrutvahini College of Pharmacy, Tal: Sangamner, Dist: Ahmednagar, Maharashtra, India 2.

Determination and pharmacokinetics of manidipine in human plasma by HPLC/ESIMS

Determination of Clarithromycin in Human Plasma by LC-EI Tandem Mass Spectrometry: Application to Bioequivalence Study

Determination of the relative bioavailability of salbutamol to the lung following inhalation

Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION

Research Article. ISSN Available online at 746

Bioequivalence of indinavir capsules in healthy volunteers

Dr. M.Mothilal Assistant professor

International Journal of Pharma and Bio Sciences

Study of the British Pharmacopeia method on methimazole (thiamazole) content in carbimazole tablets

Scholars Research Library

Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms

Development and Validation of a New Uv Method for the Analysis of Rebamipide

Journal of Chemical and Pharmaceutical Research, 2018, 10(3): Research Article

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE

World Journal of Pharmaceutical Research

ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC

Saliva Versus Plasma Bioequivalence of Rusovastatin in Humans: Validation of Class III Drugs of the Salivary Excretion Classification System

Metformin IR tablets: partial in vitro dissolution profiles differences do not preclude in vivo bioequivalence

HPLC-UV Determination of Abacavir Sulphate in Pharmaceutical Dosage Forms

DEVELOPMENT, VALIDATION AND APPLICATION OF THE HPLC METHOD FOR DETERMINATION OF MIANSERIN IN HUMAN SERUM

Journal of Chemical and Pharmaceutical Research

retardation in infants. A wide variety of analytical methods for the analysis of

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET

Bioequivalence study of two different formulations of 300 mg gabapentin capsule in Thai healthy volunteers

MEDAK DIST. ANDHRA PRADESH STATE, INDIA. Research Article RECEIVED ON ACCEPTED ON

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

International Journal of Pharma and Bio Sciences

SIMPLE AND VALIDATED RP-HPLC METHOD FOR THE ESTIMATION OF CARBOPLATIN IN BULK AND FORMULATION DOSAGE FORM. Subhashini.Edla* B.

NOVEL RP-HPLC METHOD. B.Lakshmi et a. concentration range KEY INTRODUCTION. Diltiazem is used to. . It works by of contractionn of the. (dilate).

CHAPTER 3: ANALYTICAL METHOD DEVELOPMENT AND VALIDATION

Stability indicating RP-HPLC method development and validation of Etizolam and Propranolol hydrochloride in pharmaceutical dosage form

Biowaiver Study on Prednisolone Tablets 5 mg in Three Different Brands. Marketed in Sudan. Safaa Mohamed *, Tilal Elsaman

Pelagia Research Library

Pelagia Research Library

Pelagia Research Library

Development, Optimization and Validation of HPLC Method for Determination of Pravastatin Sodium in Tablets

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF LACOSAMIDE IN BULK AND ITS PHARMACEUTICAL FORMULATION

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

AN HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF RISPERIDONE AND TRIHEXYPHENIDYL HYDROCHLORIDE FROM BULK AND DOSAGE FORMS.

Abstract. G. D. Patil 1, P. G. Yeole 1, Manisha Puranik 1 and S. J. Wadher 1 *

DEVELOPMENT AND VALIDATION UV SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF ATENOLOL IN PURE MATERIALS AND PHARMACEUTICAL DOSAGE

New RP-HPLC Method for the Determination of Fludarabine in Pharmaceutical Dosage Forms

Formulation and evaluation of immediate release salbutamol sulphate

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

RP-HPLC analytical method development and optimization for quantification of donepezil hydrochloride in orally disintegrating tablet

Validation of Changes to the USP Assay Method for Ibuprofen Tablets

UV-Spectrophotometric methods for estimation of Valsartan in bulk and tablet dosage form

Compliance. Should you have any questions, please contact Behnaz Almasi, Associate Scientific Liaison ( or

Development and Validation of a UV-Spectrophotometric Method for Quantification of Atorvastatin in Tablets

Sheikh R J et al. IRJP 1 (1)

Volume 2 (6), 2014, Page CODEN (USA)-IJPRUR, e-issn: International Journal of Pharma Research and Health Sciences

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

The Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph.

Interchangeability of Two 500 Mg Amoxicillin Capsules with One 1000 Mg Amoxicillin Tablet After a Single Oral Administration

Available online Research Article

Development and Validation of RP-HPLC Method for the Estimation of Gemigliptin

DETERMINATION OF LOTEPREDNOL ETABONATE AND TOBRAMYCIN IN COMBINED DOSAGE FORM USING RP-HPLC METHOD

Corresponding Author:

Method Development and Validation for Simultaneous Estimation of Atenolol and Nifedipine in Pharmaceutical Dosage Forms by RP-HPLC

36 J App Pharm Vol. 6; Issue 1: 36-42; January, 2014 Rao et al., 2014

contents of the currently official monograph. Please refer to the current edition of the USP NF for official text.

Journal of Pharmacreations

Development and Validation of Stability Indicating HPLC method for Determination of Eperisone HCL in Bulk and in Formulation

International Journal of Drug Research and Technology

Development of a Validated RP-HPLC Method for the Analysis of Citicoline Sodium in Pharmaceutical Dosage Form using Internal Standard Method

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Transcription:

Scientia Pharmaceutica (Sci. Pharm.) 72, 227-237 (2004) 227 0 Osterreichische Apotheker-Verlagsgesellschaft m. b. H., Wien, Printed in Austria Comparative Bioavailabilitv Studv of Two Brands of Terbutaline Sulphate Tablets in Healthy Human Volunteers Nahla S. ~arakat*', Nawal M. ha la fall ah^, Said A. ~halil* '~epartment of Pharmaceutics, Faculty of Pharmacy, King Saud University, El Riyadh, Saudi Arabia 2~epartment of Pharmaceutics, Faculty of Pharmacy, Alexandria University, Alexandria, Egypt. Abstract The purpose of this study was to evaluate the bioavailability of locally produced 2.5 mg terbutaline sulphate tablets (brand A ) relative to a reference product, Bricanyl 2.5 mg tablets (brand 6). The study was a single dose 5 mg randomized crossover one in 15 healthy volunteers in the fasting state. Urine was collected at intervals of 24 h. Total terbutaline excreted in urine as unchanged drug and as conjugates (sulphate and glucuronide) was determined by a developed and validated HPLC method. In-vitro characteristics of both brands were similar. Based on percent of the dose excreted in urine, the oral bioavailability ranged from 33.5% to 75.8% for both brands. Statistics were applied to judge bioequivalence according to USP 24 in-vivo bioequivalence guidance. Results indicated that brand A and B were bioequivalent and hence interchangeable in medical practice. Keywords Terbutaline sulphate; Tablet; Bioequivalence; Urine; HPLC analysis Introduction Terbutaline sulphate, 1 -(3,5- dihydroxypheny1)-2-(t-butylamin)ethanol sulphate is a pz adrenergic agonist used mainly in the treatment of asthmatics to produce bronchodilatation. The drug is administered orally, parenterally and by inhalation. The bioavailability of oral terbutaline ranges from 25 to 80% in different individuals

228 N. S. Barakat et al.: and is decreased by food. Around 60 % of the absorbed drug, following oral administration, circulates conjugated mainly to sulphate and less to glucuronide, both of which are pharmacologically inactive, and are formed presystemically in gut wall and liver. 90% of the absorbed drug including free and conjugated terbutaline is excreted in urine (1-4). These facts coupled with low plasma terbutaline levels in the ng m ~ range " (4), suggest that urinary excretion data of total terbutaline could be a possible substitute to blood level in comparative bioavailability studies. The aim of the present study is to compare the bioavailability of locally produced 2.5 mg terbutaline sulphate tablets with a reference product in healthy volunteers, by measuring total free and conjugated terbutaline excreted in urine, in a single dose crossover study, using a sensitive, rapid and validated HPLC method. Experimental Subjects Fifteen healthy male volunteers participated in the study after obtaining their signed informed consent. Their age ranged from 21 to 41 years (mean, 31.9), and their mass from 56 to 95 kg (mean, 73.7). They were judged to be healthy by a physician after physical examination and clinical laboratory tests. The study was performed in accordance with the Declaration of Helsinki. The study protocol was approved by the Institutional Review Board and the Risk Involving Human Subject Committee of the FDA. The volunteers were instructed to abstain from taking any medication one week prior to and during the study week. Materials The dose administered was 5 mg terbutaline sulphate as either two tablets (brand A), each containing 2.5 mg terbutaline sulphate produced by Arab Drug Co.,

Comparative Bioavailability Study of Two Brands of Terbutaline Sulphate... 229 Egypt, or as two Bricanyl tablets (brand B), each containing 2.5 mg terbutaline sulphate produced by Astra, (Sweden, Batch No TF 225). Other materials used include an ion-pairing agent for extracting free terbutaline from urine into chloroform, di-(2-ethylhexy1)-phosphate from Sigma Chemicals Co. (USA), acetonitrile far UV (Hiper Solv, BDH), chloroform (Analar, BDH), terbutaline sulphate powder supplied by the Arab Drug Co., Apparatus The HPLC apparatus comprised a single piston pump (Waters model 501, Zaters associates, USA), a reversed phase C18 column; 150 x3.9 mm i.d.; 5pm, particle size (Nova-Pak, Ireland), a tunable absorbance detector (Model 486, Waters Associates), a loop injector equipped with a 50 pi loop (Rheodyne, USA) and a data module integrator (Model 746, Waters Associates). Study design The study was random two-way crossover design (Tablel). Each subject received a single dose of either brand A or B with 200 ml of water after an overnight fast. Subjects continued fasting for further 4 h but drank water regularly. A standard meal was served 4 h after dosing. Urine was collected just before dosing and at 2, 4, 6, 8 and 24 h. Urine volume was recorded and an aliquot was frozen (- 18" C for a maximum of 2 weeks). After a period of 7 days, the study was repeated in the same manner to complete the crossover design. No drug could be detected by HPLC in urine collected 24-48 h in a pilot experiment. Chromatographic conditions Urine samples were analyzed for terbutaline according to a sensitive selective and accurate high performance liquid chromatography (HPLC) method. The method of extraction of terbutaline from urine samples was adapted with some modification from a method reported for the extraction of salbutamol from plasma

230 N. S. Barakat et al.: (5) as terbutaline is very close chemically to salbutamol. The method was developed and validated before the study in our laboratory. Chromatographic conditions were as follows: The mobile phase consisted of 5% acetonitrile and 1% methanol in 0.5% acetic acid adjusted to ph 4.0. Injected sample volume was 50 pi,. flow rate of degassed mobile phase 1 ml. min-' at ambient temperature, UV detector set at 276 nm at an attenuation of 0.04 aufs. No interfering peaks from urine samples was observed. Detection of terbutaline was achieved by monitoring the absorbance at a wavelength of Table I Study design Group Number of volunteers I (7) Treatment Period 1 Period 2 A B 276 nm; the peak area was measured and the concentration was calculated using the corresponding linear regression equation relating peak areas of the standards to their concentrations. The retention time of terbutaline was 5.3 min. Each analysis required a maximum of 8 min. The method was validated by following international guidelines (6). Processing of urine samples and standards Fifly pl of 10 mol L-' HCL were added to one ml of each urine sample and the tubes were incubated at 40 OC overnight to hydrolyze terbutaline conjugates (1). Hydrolysed urine samples were neutralized with 50 pl 10 rnol L-' NaOH. One ml of phosphate buffer (0.5 rnol L-', ph 7.2) was added together with 6 ml of 0.1 mol L-I diethylhexyl phosphate in chloroform. The tubes were vortexed for 5 minutes and

Comparative Bioavailability Study of Two Brands of Terbutaline Sulphate... 23 1 centrifuged at 3000 rpm for 20 minutes. The urine layer was discarded and the remaining chloroform layer washed with 3 ml water which was separated and discarded, and the drug in chloroform was extracted into 500 pl 0.5 mol L-' HCL. An aliquot of 50 pl of this acidic extract was injected onto the HPLC column. Recovered standards, 2-6 pg. m~-' terbutaline sulphate in blank urine were processed with each set of samples. In vitro studies Samples of the two brands were tested according to the USP 24 (7) compendial requirement with respect to their mass variation, content uniformity and dissolution profile was performed USP apparatus 1, 100 rpm, 900 ml of water at 37 k 0.5" C) Samples were withdrawn at designated time intervals and assayed by HPLC. Six pl 10 mol L-' HCL were added to each ml sample before injection to ensure peak sharpness. HPLC conditions were as detailed above. Statistical analysis Two-way analysis of variance (ANOVA, GLM procedure; using Win Nonlin computer program (8) for crossover design was used to asses the effect of formulation, periods, sequences and subjects within sequence on percent of the dose excreted in urine (9). Sequence effects were tested against the mean square term for subjects within sequence. All other effects were tested against the mean square error term. The difference between two brands was considered statistically significant for p-values equal to or less than 0.05. Parametric 90% confidence intervals (10) based on the ANOVA of the mean difference (A-B) of % terbutaline excreted values were computed. Results and Discussion Results of compendial in vitro tests for brand A & B (Table 2) indicated that both brands met specifications required by USP 24.

232 N. S. Barakat et al.: Table 2 In vitro data for terbutaline sulphate tablets USP 24 tests Brand A Brand B Mass variation (10 individual tablets, mean massf SD) Content uniformity ( 10 individual tablets, mean 104.10 + 0.44 98.40 k 0.31 content as % of labeled amount fsd) Dissolution limit 100% within 15 100% within 10 minutes minutes The cumulative amount (%) of terbutaline dissolved in vitro from both brands of test tablets and reference tablets is plotted as a function of time in Fig. 1. The results are within the range of USP 24 dissolution requirements; not less than 75% of the labeled amount of terbutaline is dissolved in 45 min. A representative standard line of terbutaline sulphate within concentration range of 2-6 pg. ml-' resulted in R of 0.9978. Assay recovery values, obtained by comparing peak areas of recovered standards with direct injection of standards in 0.5 mol L-' HCL were 63.3 % k17.1 (n=23) at2pg.m~-i, 64.7 % 212.4 (n=30) at 4 pg.ml-' and 69.8% k 12.7 (n.32) at 6 pg. m L" The intra-day precision of the assay (Table 3) was evaluated by replicate (n=3) analyses of urine samples containing terbutaline sulphate at three different concentrations. The relative standard deviation ranged from 1.2 to 8.3%. The inter- day precision of the assay was assessed by performing several standard curves using three different concentrations over a range of 2-6 pg ml-' in blank urine and were repeatedly analyzed on different days over a period of 32 days. The inter-day relative standard deviation varied from 4.3 to 12.6%.

Comparative Bioavailability Study of Two Brands of Terbutaline Sulphate... 233 I 10,I 2U 1U Time, min Figure I: Dissolution rate of (0) brand A, ( ) brand B tablets according to USP 24 test, each point is the mean of 6 tablets. Table 3: Inter-day and intra-day precision of terbutaline sulphate in blank urine Terbutaline sulphate Inter-day RSD (%)a Intra-day RSD (%) added (pg.m~") 2 12.6 8.3. 4 5.7 4.2 6 4.3 1.2 Number of independent analyses: a n = 32, n = 3 Table 4 gives mean cumulative excretion * SD obtained for each brand at different times. Mean excretion rates are shown in Figure 2. Eight of thirty individuals excretion rate profiles showed double peaks; the earlier peak appearing at 1 h and later one at 5-7 h. similar double peaks in serum

N. S. Barakat et al.: 0 0 2 4 6 8 10 12 14 16 18 Time. h Figure 2. Mean urinary excretion rate of terbutaline expressed as terbutaline sulphate, following the oral administration of 5 mg terbutaline sulphate to 15 volunteers, (0) brand A, (e) brand B Table 4 Mean cumulative total terbutaline excreted in urine 24 h following 5 mg oral dose of terbutaline sulphate Mean cumulative excretion, mg (+_SD)a Time (h) Brand A Brand B 2 0.332 (0.18) 0.395 (0.17) 4 0.802 (0.29) 1.016 (0.42) " Calculated as terbutaline sulphate.

Comparative Bioavailability Study of Two Brands of Terbutaline Sulphate... 235 terbutaline profiles following oral administration have been reported (4). Percent of the dose excreted as unchanged terbutaline and as conjugates in 24 h is shown in Table IV. The values obtained reflect percent absorbed and ranged from 33.5% to 76.6 in agreement with reported value for bioavailability of terbutaline after one application ranging form 25 to 80 % (1, 2). On the basis of the % of dose excreted in the 15 volunteers, the bioavailability of brand A relative to B ranged from 76.9% to 115.5 with a mean of 97.4 % i 12.8 (Table 5). ANOVA results are given in Table 6. Effects of sequence, period and treatment proved insignificant difference between the two formulations. The 90% confidence interval for the mean difference in percent excreted between A and B fell within the conventional bioequivalence FDA acceptable range of 80-125% (Table 7), and indicated that the two brands were bioequivalent and thus considered therapeutically equivalent. Table 5 Percent of the dose excreted in urine and percent relative bioavailability Percent of the dose excreted in urine in 24 h Percent relative Volunteer code bioavailability, Brand A Brand B (AIB) x 100 1 75.8 76.6 98.5 2 41.1 53.4 76.9 3 47.2 42.1 112.1 4 59.9 65.5 91.5 5 60.8 64.4 94.3 6 59.8 65.2 91.7 7 58.2 50.4 115.5 8 47.5 59.6 79.8 9 49.0 60.0 81.7 I0 67.4 58.6 114.9 11 65.1 69.3 93.9 12 47.8 52.7 90.7 13 38.2 33.5 114.1 14 56.9 54.8 103.8

236 N. S. Barakat et al.: 15 64.9 63.7 101.8 Mean bioavailability 97.4 k 12.8 Table 6 Analysis of variance applied to percent of the dose excreted in urinein 24 h Source Degree of SS MS F freedom Sequence 1 325.79 325.79 1.73 NS Subjects within sequence 13 2444.53 188.04 Period 1 16.25 16.25 0.63 NS Treatment 1 31.29 31.29 1.22 NS Error 13 334.90 25.76 Total 29 3152.76 MS= mean square F = MSlEMS EMS= error mean square Table 7Confidence interval for the difference in percent excreted between brand A & B Parameter Mean percent excreted, brand A Value 55.9 ~t: 10.26 Mean percent excreted, brand B 57.9 + 10.34 90% Confidence interval expressed as percent 92.3% H 100.7 relative bioavailability* *Express as: Mean + t ( SD }

Comparative Bioavailability Study of Two Brands of Terbutaline Sulphate... 237 Conclusion The present study documents urinary excretion data following administration of two brands of terbutaline tablets to healthy volunteers. Analysis of variance and confidence intervals permitted judgment of bioequivalence. Both brands can be considered equally effective in medical practice. References [I] Hochhaus G, Mollmann Pharmacokineticl Pharmacodynamic Characteristics of the Beta 2-agonists Terbutaline, Salbutamol and Fnoterol. Int. J. Clin. Phmaracol. Ther. Toxicol. 1992; 9:342-362. [2] Nyberg L. Pharmacokinetic Parameters of Terbutaline in Healthy Man, An overview. Europ. J. Resp. Disease. 1984; 65:149-160. [3] Sir Collin Dollery, editors. IN: Therapeutic Drugs, Volume 2, Churchill Livingstone, 1999: T45. [4] Leferink J G et all [ Pharmacokinetics of terbutaline, a pp-sympathomimetic, in healthy volunteers and asthmatic patients. Arzneim.-Forsch.1 Drug Res. 1982; 32: 159-1 64. [5] Hutching M J, Paull J Dl Morgan D J. Determination of Salbutamol in Plasma by High Performance Liquid Chromatography with Fluorescence Detection. J. Chromatogr. Biomed. Appl. 1983; 277: 423-426. [6] Shah V P, Midha K K, Dighe S, McGilveray I J, Skelly J P, Yacobi A, Layloft TI Viswanathan C T, Cook C El McDowall R Dl Pitman K A. Spector, S. Conference Report: Analytical Method Validation: Bioavailability, Bioequivalence and Pharmacokinetic Studies. Pharm. Res. 1992; 9: 588-592. [7] The United States Pharmacopoeia (USP) 24; The National Formulary XIX, United States Pharmacopoeia1 Convention, Rockville, MD, 2000; p 1607 [8] Win Nonlin, Professional Edition, Version 2.1, Pharsight Corp., 800 West Elcamino Real, Suite 200, Mountain View, CA 94040. [9] Sanford Bolton, editor. In: Pharmaceutical Statistics, Practical and Clinical Applications, 2 nd Ed, Revised and Expanded,, Marcel Dekker, Inc. new York and Basel, 1990: 379-388. [lo] FDA Guidelines, Bioequivalence Food and Drug Administration, Division of Bioequivalence, Office of Generic Drugs: Rockville, MD, 1 July 1992. Received April 1 gih, 2004 Accepted September 1": 2004