HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

Similar documents
HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

HI Total Acidity Mini Titrator for Water Analysis

HI Total Alkalinity Mini Titrator for Water Analysis

HI Total Alkalinity Mini Titrator for Water Analysis

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

HI FREE & TOTAL SULFUR DIOXIDE MINITITRATOR for wine analysis

ph Electrodes with Bluetooth Smart Technology

EasyPlus Titration. Food & Beverage Analysis Made Easy Swiss Precision for Your Analysis

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

PtPt-electrode with temperature sensor, Intellical MTC695

Determination of Langelier Index in Water

Total Acid Number in petroleum products by automatic titration

IP67 Waterproof. Food Quality ph Meters. Five models to measure the ph and temperature of food, milk, meat, yogurt and cheese.

Thiols (mercaptans) in Fuels (ASTM D )

Measurement method Measurement objects. Measurement range

Titration DL22 F&B Food & Beverage Analyzer

QUICK START GUIDE HI 903 KARL FISCHER VOLUMETRIC TITRATOR. Revision 1.0

Water Determination in Ethanol by Karl Fischer Titration

COLE-PARMER LABORATORY SURFACTANT ION ELECTRODE INSTRUCTION MANUAL

Free Chlorine. Based on 4500-Cl D. in Standard Methods for the Examination of Water and Wastewater DOC

COLE-PARMER REPLACEABLE MEMBRANE SCIENTIFIC SURFACTANT ION ELECTRODES INSTRUCTION MANUAL

Free and Total Sulfur Dioxide (SO 2. ) in wine (Ripper method) by automatic titration

ebook Best practices using automated titrators Achieving speed and accuracy in your lab

3 To gain experience monitoring a titration with a ph electrode and determining the equivalence point.

Method (6 to 1000 µg/l Chlorine as Cl 2 ) Digital Titrator

ramé-hart Model 90 Goniometer / Tensiometer

Application Note. Determination of the Acid Number (TAN) Tips and Tricks

Pt-electrode with temperature sensor, Intellical MTC695

TECHNOCARE MEDISYSTEMS

ph Technical Calibration Solutions solutions Technical Solutions (±0.01 ph) for Each Point of the ph Scale Easy to Use Single Dose Sachets

METTLER TOLEDO Titrators. 30 Selected Applications Application brochure 12

Detection. personal. Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily.

Dräger Alcotest 6820 Alcohol Screening Device

888/890 Enter the Titrando world

Radnoti Langendorff Constant Pressure Non-Recirculating Pump Driven Isolated Heart System For Mouse EZ

Omnitest : 2013

microprocessor controlled eddy current brake Load / accuracy Watt, speed independent / according to DIN VDE

Solutions for Calibration and Maintenance

Determination of Total Hardness in Water by Automatic Titration

Dräger Alcotest 5510 Alcohol Screening Device

How acidic are the things we drink? Measuring the ph of common drinks

White Paper. Thermometric Titration of Acid Number According to ASTM D8045

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

Experiment 3. Potentiometric Titration Using a ph Electrode. information necessary for both purposes by monitoring the ph of the solution as the

SURETEST Torque Calibration System

Take an initial volume reading and record it in your. 11/17/2014 ChemLab - Techniques - Titration

Technical Data Sheet SONOFLOW CO.55 V1.0

Determination of Chlorine Dioxide, Chlorite and Chlorine

Instruction Manual Updated 8/27/2013 Ver. 1.1

EXPERIMENT 4 DETERMINATION OF REDUCING SUGARS, TOTAL REDUCING SUGARS, SUCROSE AND STARCH

Dear HighQ Check System Owner :

With extended functionality the sensors are also applicable for the detection of air bubbles.

Determination of the acid value (AV) Application Bulletin 200/3 e. Electrodes Solvotrode easyclean

SURETEST Torque Calibration System

Glucose analyser GA 3

Mobile FTIR Analyzers from Agilent. Expedite Food QA/QC Improve Food Production, Safety and Quality

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

RaySafe i3 INSTALLATION & SERVICE MANUAL

Evolve 3 & 5 Service Manual

2017 SPERM QUALITY ANALYZERS FOR VETERINARY / BREEDING MES CATALOGUE

MINISTAR DIGITAL AND CONTROL /// The new compact stirrers

Analysis of Micronutrients in Milk by Flame Atomic Absorption Using FAST Flame Sample Automation for Increased Sample Throughput

EKG Sensor Product Number: ENEKG189

Parts and Consumables. Sciclone ALH 3000 and Zephyr Liquid Handlers

Application Note No. 113/2013 Nitrogen & protein determination in dry pet food KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376:

Dräger Alcotest Handheld Product Suite

Determination of acid number in diesel engine oil

PROCEDURE. TITLE: Bedside Glucose Monitoring PC Laboratory. Issuing Department: Clinical Director Signature: Departments Involved:

BC380. The New Standard in Body Composition Analysis BODY COMPOSITION ANALYZER

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

Beverage Density Lab

OPTICAL FIBER SPLICING. Courtesy from Significant Technologies Sdn Bhd

Sodium Chloride Content in Ketchup by Precipitation Titration

When worker safety is mission critical. Thermo Scientific EPD TruDose Electronic Dosimeter

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems

Fitmate and all the accessories are provided together with a nice and practical carrying case.

CLEAR+STABLE The clear choice for food and beverage stability

25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual

Application Bulletin

CHEM104 Exp. 9 Phytochemical Antioxidants with Potential Benefits in Foods Part I. 1

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Rigel UNI-SiM Lite. The most cost-effective patient simulator on the market. Key Features n Compact and cost-effective

Enzymatic Analysis for Food and Feed

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual

Frequently Asked Questions

AP BIOLOGY Enzyme Catalysis

Application Note #67 Total Acid Number (TAN)

E55A GELATIN, GELLING GRADE Gelatina

Specifications are subject to change without notice. PR-D613E Ver

RLS /E-EV MX SERIES

Advanced in vitro exposure systems

Dear Prodigy System Owner:

MEDIUM-FLOW PNEUMOTACH TRANSDUCER

Storage: Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Positive Control must be stored at -20 ⁰C and can last up to 60 days.

Quantitative Measurement of Emergency Biomarkers in Parallel

Enzyme Action: Testing Catalase Activity

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2

Carina. The compact wonder. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Transcription:

HI 84532 Titratable Acidity Mini Titrator for Fruit Juice Analysis

Piston Driven Pump with Dynamic Dosing The HI 84532 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the amount of titrant dosed as the end point is approached for increased accuracy in end point detection. Piston Burette Piston burettes provide an exceptionally reliable titrant delivery. This highly accurate dosing method is attained by combining a pulse controlled step motor with a 5 ml polypropylene syringe. The rigid and stable body of our syringe allows for less frequent pump calibration. Users no longer have to account for the changing elasticity of tubing associated with peristaltic pumps. More About Dynamic Dosing With the integration of our piston burette, our titrator can adjust the volume and frequency of titrant dosed based on relative mv changes in the testing solution. This titrant delivery system is known as dynamic dosing, where titrant is delivered in larger doses at the start of the titration and smaller doses near the end point. These differences in dosing volume and frequency result in a faster titration without sacrificing accuracy. With larger doses in the beginning of the titration, the speed of the titration is increased, where smaller doses near the end point allow for more time for the titrant and analyte to react. Smaller doses also prevent the over titration of a sample and a more accurate determination of titrant volume used. ph Electrode The HI 84532 is supplied with the HI 1131B refillable, double junction, combination ph electrode. By design, the HI 1131B has a spherical tip for use in aqueous or liquid solutions. This versatile electrode provides a wide surface of contact with a sample and is ideal for any general acid or base titration in the beverage or agriculture industry.

HI 84532 Mini Titrator for Fruit Juice Applications Piston Driven Pump with Dynamic Dosing This piston driven dosing pump incorporates dynamic dosing to provide highly accurate, repeatable results. CAL CHECK CAL CHECK alerts users to potential problems during calibration such as contaminated buffers or dirty/broken electrodes. ph/mv M eter In addition to automatic titration, the HI 84532 can also be used as a ph/mv meter. Log-on-Demand Log data up to 400 samples (200 for titration; 200 for ph/mv). Graphic Mode/Exportable Data Displays in-depth data on titration, which can then be stored and exported to either a USB drive or PC using the USB connection. Automatic Stirrer Speed Control Maintains stirrer speed at approximately 600 rpm regardless of viscosity of solution. GLP Feature The HI 84532 includes a GLP Feature that allows users to view calibration data for the ph electrode and dosing pump. Easy to use interface User intuitive design with large keys and easy to navigate screens. ph Electrode The HI 84532 is supplied with the HI 1131B electrode. This versatile electrode can measure all types of fruit juice.

Easy to Use, Fast and Affordable All-in-one Solution The HI 84532 digital automatic mini titrator and ph meter is designed for measuring the concentration of titratable hydrogen ions contained in fruit juice samples by neutralization with a strong base solution to a fixed ph as according to the official methods of analysis of AOAC International. This new generation of mini automatic titrator improves upon the titrant delivery system and measuring ranges for increased accuracy compared to previous models. This meter reflects Hanna s years of experience as a manufacturer of analytical instruments. A clear and intuitive user interface allows users to navigate the HI 84532 s menus and functions quickly. The HELP key located on the keypad aids in on-screen set-up, calibration status and troubleshooting. The HI 84532 incorporates a precise piston dosing system, which allows for a highly accurate determination of the amount of titrant used. It is capable of dynamic dosing, making testing both faster and more accurate. Pump calibrations, performed with the provided Hanna standards, help assure the measurement accuracy. This mini-titrator is also designed to be used as a benchtop ph/mv meter. As a ph meter, it has many features of a professional grade benchtop including automatic calibration up to 3 points with 4 available buffers, a 0.01 ph resolution, accuracy of +/- 0.01 ph, automatic temperature compensation and comprehensive GLP Data. The GLP data includes date, time, offset, slope, and buffers used for calibration. Accuracy is always ensured with Hanna s unique Cal-Check feature, which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffers, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty / Broken, and overall probe condition as a percentage that is based on both the offset and slope characteristic of the electrode. The Cal-Check function not only ensures an accurate ph reading when the HI 84532 is used as a ph meter but also an accurate titration since the end point is determined by a set ph value. Why Titratable Acidity is So Important Titratable acidity is an important parameter in determining fruit maturity and sour taste in citrus fruits. The maturity of fruit is one of the most important factors to determine how well fruit will store and how it will taste. For some fruits, governmental quality standards (based on titratable acidity or the ratio of total soluble solids ( Brix) to titratable acidity) are in place to protect consumers. Immature fruit will normally have a low sugar to acid ratio as compared to mature fruit that will have a high sugar to acid ratio. The HI 84532 measures the concentration of titratable hydrogen ions contained in fruit juice samples by neutralization with a strong base solution to a fixed ph. This value includes all the substances of an acidic nature in the fruit juice including: free hydrogen ions, organic acids and acid salts. Titratable acidity is expressed as g/100 ml of the predominant acid. The predominant acids in fruit depend on the type of fruit being tested and include citric acid, tartaric acid, and malic acid. Fruits, juices Titratable acidity (g/100 ml) Apple, pear 0.36-0.80 Malic acid Cranberry 1.6-3.6 Citric acid Grapefruit 1.2-2.0 Citric acid Lemon 4-6.2 Citric acid Mango 0.34-0.84 Citric acid Orange 0.8-1.4 Citric acid Peach, nectarine, sweet cherry 0.24-0.94 Citric acid Pineapple 0.7-1.6 Citric acid Plum/Sour cherry 0.94-1.64 Malic acid Strawberry 0.6-1.1 Citric acid Table grape 0.4-0.9 Tartaric acid Tomato 0.34-1.00 Citric acid Predominant acid All-in-One Fruit Juice Titrator, ph Meter, Electrode and Magnetic Stirrer in one package

Features Setup Screens The LCD features an easy to use setup screen that allows the user to change measuring range, time, date, language and more. Tutorial and HELP Screens Accessing the tutorial menu provides helpful information during calibration and titration. Rear USB Outputs For PC connection and to export data to a USB drive 1 5 2 6 7 CAL CHECK CAL CHECK is a Hanna exclusive process for checking the condition of electrodes which helps keep measurements accurate. GLP The GLP feature records electrode and pump calibration data to help keep measurements accurate and reliable. Titration Curve Displayed On Screen The HI 84532 offers real time graphing of the titration curve on the LCD. Log and Recall data The HI 84532 can log up to 400 samples (200 for titration results; 200 for ph/mv) and recall or export data to a USB drive or PC. 3 4 Display 1) Current time and instrument mode information (ph meter or Titrator) 2) Procedural indicators 3) Instrument status 4) Virtual option keys 5) Stirrer and icon status During the instrument s operation a set of information are displayed on the LCD. Displayed icons: 8 Stirrer on Pump running Wait for stable reading Procedure Warnings Users are warned if there is an error in procedures such as the use of a wrong buffer. Adjustable Backlit LCD The HI 84532 offers a backlit LCD with adjustable brightness levels. This ensures that the LCD is always easy to read. Stirrer is not working properly 6) Main reading information 7) ph temperature compensation mode (Manual or Automatic) 8) Temperature reading Parameter can be modified

Specifications HI 84532 -Titratable Acidity Accessories Titrator Citric acid g/100 ml Tartaric acid g/100 ml Malic acid g/100 ml Resolution 0.01% Accuracy (@25ºC/77ºF) Method Principle Pump speed Stirring Speed Logging Data ph Meter Low (5mL sample): 0.10-2.00 %CA 0.11-2.35 %TA 0.10-2.09 %MA 3% of reading or ± 0.02 %CA, whichever is greater High (5mL sample): 1.00-10.00 %CA 1.17-11.72 %TA 1.05-10.47 %MA Acid-base titration,method based on the Official Methods of Analysis of AOAC International. End point titration: 8.1 ph 10 ml/min 600 rpm up to 200 samples -2.0 to 16.0 ph / -2.00 to 16.00 ph Resolution 0.1 ph / 0.01 ph Accuracy (@25ºC/77ºF) ±0.01 ph Calibration 1, 2, or 3 calibration points; 4 available buffers (4.01; 7.01; 8.20; 10.01) Temperature Compensation manual or automatic from -20 to 120 C (-4 to 248 F) Logging Data Up to 200 samples (ph or mv) mv Meter Resolution Accuracy Logged Data Temperature Resolution Accuracy Additional Specifications -2000.0 to 2000.0 mv 0.1 mv ± 1.0 mv Up to 200 samples (ph or mv) -20.0 to 120.0 C (-4.0 to 248.0 F) 0.1 C ±0.4 C without probe error ph Electrode HI 1131B glass body, refillable, with BNC connector and 1 m (3.3 ) cable (included) Temperature Probe HI 7662-T stainless steel temperature probe with 1 m (3.3 ) cable (included) Environment 0 to 50 C (32 to 122 F); RH max 95% non-condensing Power Supply 12 VDC adapter (included) Dimensions 235 x 200 x 150 mm (9.2 x 7.9 x 5.9 ) Weight 1.9 kg (67.0 oz.) Reagents HI 84532-50 Titrant solution for Low (100 ml) HI 84532-51 Titrant solution for High (100 ml) HI 84532-55 Calibration Standard (100 ml) ph Calibration Solutions HI 7004M HI 7007M HI 70082M HI 7010M Buffer solution ph 4.01 (230 ml) Buffer solution ph 7.01 (230 ml) Buffer solution ph 8.20 (230 ml) Buffer solution ph 10.01 (230 ml) Electrode Fill and Storage Solutions HI 7082 HI 70300L Electrode fill solution (4 x 30 ml) Electrode storage solution (500 ml) Electrode Cleaning Solution HI 7061M Electrodes HI 1131B HI 7662-T Electrode Cleaning Solution (230 ml) ph Electrode Other Accessories HI 70500 HI 71005/8 HI 71006/8 HI 731319 HI 740036P HI 740037P HI 740236 HI 920013 Temperature probe Tube set with cap for titrant bottle, tip and valve 115 Vac to 12 Vdc, 800 ma 230 Vac to 12 Vdc, 800 ma Stir bar, 25 x 7 mm (10 pcs.) 100 ml Beaker (10 pcs.) 20 ml Beaker (10 pcs.) 5 ml Syringe for minititrator PC Connection Cable Ordering Information HI 84532-01 (115V) and HI 84532-02 (230V) are supplied with: HI 84532-70 Reagent Kit for titratable acidity in fruit juice HI 1131B ph electrode HI 7662-T temperature probe HI 7082 electrode fill solution (30 ml) HI 740036P Two 100 ml beakers HI 740037P One 20 ml beaker HI 70500 Tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), Dosing Pump Valve HI 740236 5 ml Syringe 1 ml plastic pipette HI 731319 stir bar HI 920013 power adapter Instruction manual and quality certificate HannaNorden AB Energigatan 15B S-434 37 Kungsbacka Sweden +47 300 404018. info@hannanorden.com www.hannanorden.com