A shield never to be broken On1 concept

Similar documents
NobelReplace Conical Connection Product overview

Guided surgery with NobelParallel Conical Connection Product overview

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

NobelParallel Conical Connection Product overview

NobelActive Product overview


NobelProcera Product Overview

Restore your patients quality of life. Solutions for all edentulous indications

NobelProcera Implant Bar Overdenture complete range of fixed and removable solutions.

NobelActive. The NobelActive technical story

Digital Treatment Planning and Surgical Guide Fabrication

introduction to BioHorizons prosthetics

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves

screw-retained crown using the Laser-Lok Easy Ti temp abutment

Bridging the Gap Between Original and Multi-Platform Systems.

Proven stability, high esthetics NobelReplace Conical Connection

IOS & The Sirona Connect System Clinician Procedure

Complete yourself. How restoring your teeth can win back your life.

Complete yourself. How restoring your teeth can win back your life.

Trefoil The next full-arch revolution

Product Information for Labs. etkon ident Perfectly versatile. Performance you can rely on.

Proven stability, high esthetics NobelReplace Conical Connection

screw-retained crown using a PEEK temporary abutment

NobelProcera Implant Bar Overdenture EXPERIENCE THE NEW WORLD OF CAD/CAM DENTISTRY

Immediate loading and implant surgery with digital workflow

Titanium Base abutments plus screw and associated restorative and dental laboratory components.

PRE-MILLED BLANK COMPLETE SOLUTION

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

cement-retained single crowns using cementable abutments

Full mouth rehabilitation with digital workflow

INTERNAL HEX ( ps) PLATFORM SHIFT PRESERVATION OF BONE NEVER LOOKED BETTER

A Clinician s Guide to Restoring Screw Retained Full Zirconia Implant Crowns.

Legacy Prosthetic Catalog

open tray technique using the direct pick-up coping

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte

Implant Studio Patient Case

Ø Smaller and Stronger.

Simply straightforward NobelParallel Conical Connection

LDAC Laboratory Designed Abutments For Competitive Systems. Precision Engineered

Description: Prosthetic Components for dental restoration under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series.

3Shape TRIOS Implant Scanning

fabricating a custom impression coping using the closed tray technique

closed tray technique using the indirect transfer coping

Multi-unit abutment open tray technique using the direct pick-up coping

surgical and prosthetic options & impression technique overview

Being the partner of choice

Validating innovation.

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

ball abutment overdenture: chairside pick-up using existing denture

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

Biomimetic Product catalogue

» For multi-unit restorations -

PRE-MILLED ABUTMENTS COMPLETE SOLUTIONS

The intelligent system.

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

Product Information. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance. The NEW. Variobase family members

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

Guided immediate loading implant surgery planned with Implant Studio D.D.S. Jae-min, Lee

closed tray pick-up technique using the snap coping

CAD/CAM SMARTbase Beauty Done Better

How I use Lasers with Dental Implants for Soft and Hard Tissue Management, making the whole process easier (0052) Dr Robin Horton BDS

the way to straumann cares abutments

Simplant. Guided Surgery. delivering restorative driven implant treatment

Cost-effective immediate restoration in the anterior region of the mandible (isy by CAMLOG)

OD Secure chairside pick-up using existing denture

3.5 mm LCP Extra-articular Distal Humerus Plate

Ø Smaller and Stronger.

Product catalog 2015/16 Complete assortment. Updated version December 2015

Complete yourself. Why it s important to replace even a single missing tooth.

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle

Screw retained implant crown restoration with digital workflow using scan body and surgical guide

Multi-unit abutment bar overdenture

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

TABLE OF CONTENTS P. 4-5 P. 6-7 P. 8-9 P P P P

Catalog. etkon ident Compatibles perfected. From a partner you can trust _etkon_iDent_Catalogue_nordic indd :56:11

Quick start Prosthetics

ATTACHMENT SYSTEM. LOCATOR R-Tx REMOVABLE U.S. RETAIL PRODUCT CATALOG AND PRICE LIST*

SwissPlant Prosthetic Catalog. SwissPlant

SIMPLANT Guided Surgery delivering restorative-driven implant treatment

Multi-unit abutment closed tray technique using the indirect transfer coping

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Company Presentation 2016

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

For technical assistance: Tel Working time: 8.30 am pm

NobelActive. Quick start page 5. Surgical procedures page 8. Prosthetic procedures page 28. Appendix IV cleaning and. sterilization page 66

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

NobelActive. The NobelActive technical story

The difference is obvious. Original components by Straumann

verification jig fabrication

FIXED-HYBRID EMERGENCY! Why Redo When You Can Rescue?

Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS

Welcome to DENTSPLY Implants

Multi-unit abutment hybrid or fixed-detachable screw-retained restoration

SIC invent. SIC P2F Abutment Dr. Galip Gurel From the gingiva shaper to a provisional crown to the final aesthetic restoration

Low Bend Distal Tibia Plates

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free

Transcription:

A shield never to be broken On1 concept

Gain peace of mind The On1 Base has a unique prosthetic connection, ensuring that only precision-engineered Nobel Biocare restorations are used. F a cos( ρ ) cos( α ) 2 p= d m π l sin(ρ + α ) 2 A system is only as strong as its weakest link. This is why the On1 concept is designed and tested as a complete system. Small changes in any parameter can lead to extreme load and stress conditions, which can ultimately result in implant failure. Leave the immediate soft tissue attachment intact The On1 Base is seated at the time of implant placement. The immediate soft tissue attachment is then left intact as the On1 Base remains in situ during the entire restorative workflow and throughout the lifetime of the restoration. Sulcus Junctional epithelium Removed healing abutment Cells Adhering to Abutment surface Conective tissue The On1 concept avoids repeated disruption of the soft tissue. This reduces the risk of bacteria entering the site. It also results in less discomfort for your patient. Maintain surgical flexibility The On1 concept can be used with any Nobel Biocare conical connection implant system, each designed for high primary stability and built-in platform shifting. NobelParallel CC NobelActive NobelReplace CC

The On1 concept is unique. It s the first concept to preserve the soft tissue attachment and maintain full restorative and surgical flexibility. The On1 concept also radically simplifies the restorative procedure, as it moves the prosthetic platform from bone level to tissue level.

Choose your preferred workflow The On1 concept provides you with the option to follow the conventional impression taking workflow or the intraoral scan workflow using the special On1 IOS (Intraoral Scannable) Healing Cap. For easier handling, key components are delivered with a pre-mounted holder. Option 1: following the conventional workflow, the On1 Base stays in position while the healing cap, temporary restoration, impression coping and final restoration are placed. Option 2: Following the intraoral scan workflow, only the IOS Healing Cap is used before the final restoration is placed. Increase workflow efficiency with intraoral scanning Save substantial chair time with the unique On1 IOS Healing Cap, which supports an intraoral scan workflow. This eliminates conventional restorative procedures, including impression taking, while also serving as an anatomically shaped healing abutment for optimized soft tissue contouring.

With On1 you get the best of both worlds a bone-level implant with built-in platform shifting and restoring at tissue level without disturbing the mucosal seal. Dr. Bernard Touati, France 35-year-old male, missing premolar, non-smoker and good overall tissue health. Preoperative clinical situation. Premolar missing. NobelReplace CC RP implant is placed following a flap approach. The On1 Base is easily seated using the pre-mounted handle. The On1 Healing Cap is placed and the site is sutured. It is left to heal for three months. Post-operative X-ray to verify correct seating of On1 components. The site after nine days of healing. After three months of healing, the On1 Impression Coping is attached. Impression is taken, now working only at tissue level. The On1 Universal Abutment is attached to the On1 Base and torqued to 35 Ncm. The final crown is attached to the On1 Universal Abutment. Occlusal view of final restoration. Lingual view of final restoration. Radiograph after placement of final restoration.

As strong as ever Extensive fatigue and strength testing of our systems (ISO 14801) is an integral part of product development at Nobel Biocare. It is designed to ensure our components perform as expected in a clinical setting. The On1 concept has gone through this thorough testing and was shown to be just as strong as any other prefabricated Nobel Biocare titanium abutment. The ISO 14801 test: Dynamic bending compression tests on the system Testing performed in saline solution at 37 C Evaluation of the dynamic/fatigue strength performance Frequency: 2Hz; Run-out Cycles: 2,000,000 Evaluation of screw residual torque after testing Peace of mind The warranty covers all Nobel Biocare implants including prefabricated prosthetic components. For further information visit nobelbiocare.com/warranty Order online Order the complete range of our implants and prefabricated prosthetics 24 hours a day through the Nobel Biocare online store. nobelbiocare.com/store 30 off-axis fatigue testing in saline solution. Order by phone Call our customer service team or contact your sales representative. 80628 C GB 1804 Printed in the EU Nobel Biocare Services AG, 2016. All rights reserved. Nobel Biocare, the Nobel Biocare logotype and all other trademarks are, if nothing else is stated or is evident from the context in a certain case, trademarks of Nobel Biocare. Please refer to nobelbiocare.com/trademarks for more information. Product images are not necessarily to scale. Disclaimer: Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Nobel Biocare sales office for current product assortment and availability. For prescription use only. Caution: Federal (United States) law restricts this device to sale by or on the order of a licensed dentist. See Instructions for Use for full prescribing information, including indications, contraindications, warnings and precautions. nobelbiocare.com/on1