Titanium Base abutments plus screw and associated restorative and dental laboratory components.

Similar documents
Description: Prosthetic Components for dental restoration under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series.

The Multi-unit Abutments of the CE-Series are indicated for Nobel Biocare / NobelReplace Tapered. The current implant diameters have to be attended.

More than Abutments. catalogue

» For multi-unit restorations -

Bridging the Gap Between Original and Multi-Platform Systems.

PRODUCT INFORMATION FOR CORTEX ABUTMENTS AND OTHER RESTORATIVE COMPONENTS

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

LOCATOR R-Tx REMOVABLE ATTACHMENT SYSTEM

Catalog. etkon ident Compatibles perfected. From a partner you can trust _etkon_iDent_Catalogue_nordic indd :56:11

for individual abutment design large glue surface, so durable solid connection to the base conventional usable and also for CAD/CAM process

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

This recommendation outlines the requisite steps for the optimal use of the BEGO CADPositioner.

ATTACHMENT SYSTEM. LOCATOR R-Tx REMOVABLE U.S. RETAIL PRODUCT CATALOG AND PRICE LIST*

TruAbutment Digital Solutions


INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

NobelActive. The NobelActive technical story

Product Information for Labs. etkon ident Perfectly versatile. Performance you can rely on.

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

PRE-MILLED BLANK COMPLETE SOLUTION

SIMPLANT Guided Surgery delivering restorative-driven implant treatment

Digital Treatment Planning and Surgical Guide Fabrication

SOLUTIONS. DentalWiz. extending the art of Simplantology, to your CAD /CAM restoration jobs, making it as simple as our implant systems.

Simplant. Guided Surgery. delivering restorative driven implant treatment

Wirobond C+ Processing information for CAD/CAM-produced restorations. Partners in Progress

PRE-MILLED ABUTMENTS COMPLETE SOLUTIONS

User Manual Complete Prosthetic Kit (CPK)

Intraoral Library INSTRUCTIONS FOR USE DYNAMIC ABUTMENT SOLUTIONS LIBRARY INST_EXOCAD_INTRAORAL_01_2017_01_EN. scan

cara I-Bridge Overview of platforms and systems es life so easy

NobelEsthetics. Introduction page 4. Temporary implant restorations page 6. Solutions for existing teeth page 14. Final implant restorations page 26

Leading material offering and application range. Straumann CARES CADCAM

Restorative Manual. April

cara I-Bridge Overview of platforms and systems es life so easy

cara I-Bridge Torque for Prosthetic Screws and overview of Screwdrivers

NobelProcera Product Overview

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

Platform overview. cara I-Bridge Overview of platforms and systems. Giving a hand to oral health.

TITANIUM BASES CAD/CAM FOR CROWN AND BRIDGE RESTORATIONS CAD/CAM PROSTHETICS ON CAMLOG AND CONELOG IMPLANTS

STRAUMANN CARES DIGITAL SOLUTIONS. CARES Implant Prosthetics Ultimate restorative flexibility.

» Passion IMPLANT PICK-UP. for Precision « MPS Multi Platform Systems. Closed tray

» MEDENTIKA PreFace Abutments

INHOUSE FABRICATION OF CUSTOM TITANIUM ABUTMENTS THE INHOUSE MOVEMENT

NEW IMPLANT PLATFORMS AVAILABLE NewJANUARY 2018

Platform overview. cara I-Bridge Overview of platforms and systems. Giving a hand to oral health.

Being the partner of choice

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

NobelProcera Implant Bar Overdenture complete range of fixed and removable solutions.

Watson Dental Lab Fixed Hybrid Protocol

S-SERIES. compatible to: DENTSPLY Implants / Astra Tech Implant System OsseoSpeed TX. PLATFORM 3,5 / 4,0 mm 4,5 / 5,0 mm TITANIUM BASE

IMPLANT PROSTHETICS

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

Hex-Lock Abutment System. Restorative Manual

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

/NobelReplace Ø4.3mm. /NobelReplace Ø3.5mm

cara I-Bridge Manual cara makes life so easy

STRAUMANN CARES CUSTOMIZED PROSTHETIC SOLUTIONS

A shield never to be broken On1 concept

Straight Octagon Abutment for Tissue Level Implant

Guidance for. implant removal. Straumann Dental Implant System

Guided surgery manual

CAD-CAM SOLUTIONS CAD-CAM SOLUTIONS

LDAC Laboratory Designed Abutments For Competitive Systems. Precision Engineered

TECHNICAL GUIDE. For use with CEREC

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Dual-Use Scan Bodies ID and Implant Configuration For itero. Precision manufactured by

BEGO PMMA Multicolor Processing information for CAD/CAM-produced restorations

Implant-supported crowns Working Instructions

the way to straumann cares abutments

Directions For Use. Zirconia. Minimum occlusal wall thickness: 0.5 mm, including a 0.1 mm reserve for occlusal adjustment

VITA ENAMIC. Implant-supported crowns. Working Instructions. VITA shade, VITA made. VITA shade control. VITA shade reproduction. Date of issue: 07.

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

BIOTECH DENTAL GROUP, 2.0 DENTAL OFFICE PARTNER.

Straumann Screw-retained Prosthetics

cement-retained single crowns using cementable abutments

US Implant System 2013 PROSTHETIC PROCEDURE

» Passion IN A NUTSHELL. for Precision « MPS Multi Platform Systems

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

Product Information. Straumann CARES Scan & Shape Turning into digital solutions.

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

More than pure esthetics. The natural and strong solution.

E-SERIES. compatible to: Nobel Biocare / Replace Select. PLATFORM 3,5 mm NP 4,3 mm RP 5,0 mm WP 6,0 mm TITANIUM BASE SCAN BODY 3D-GUIDE LAB ANALOG

KAREN O. From Failure to Fantastic

*Digital Implant Model ANALOG Available for 24 implant systems in the nt-iq library FEATURES: INTERNATIONAL PATENT PENDING

BEGO SCAN AND DESIGN CENTRE Guidelines Partners in Progress

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle

4766 Research Dr. San Antonio, TX insightdentalsystems.com

Quick start Prosthetics

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

screw-retained crown using the Laser-Lok Easy Ti temp abutment

for individual milled Zirconium Abutment incl. screws Titanium Grade 5 ELI CAM CAM CAM CAM

N T- P R E F O R M CaTalOguE

3. Guarantee conditions

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

IOS & The Sirona Connect System Clinician Procedure

Ceramill UP-TO-DATE. Update concerns the following software packages: Release _ Ceramill Mind Database _ Ceramill Match 2 (CAM Software)

Transcription:

Instructions for use Titanium Base abutments plus screw and associated restorative and dental laboratory components. Description: Titanium Base with screw for Individual abutments under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series, CC-Series, CK- Series, CV-Series. Indications: Abutment Direct Inc. manufactures dental abutments and restorative components designed for the restoration of dental implant treatment including single tooth and multi-tooth restorations. The individual abutments can be combined with copings, crowns or suprastructures made of dental ceramics. The Titanium Bases with screw for the CE-Series are indicated for Nobel Replace Straight Groovy, Replace Select Tapered, Replace Select Straight, Nobel Replace Tapered Groovy, NobelSpeedy Replace, NobelReplace platform shift, manufactured by Nobel Biocare. The Titanium Bases with screw for the CC-Series are indicated for Camlog implants, manufactured by Camlog. The Titanium Bases with screw for the CF-Series are indicated for NobelActive implants, manufactured by Nobel Biocare. The Titanium Bases with screw for the CH-Series are indicated for Biomet 3i Certain implants, manufactured by Biomet 3i. The Titanium Bases with screw for the CK-Series are indicated for Branemark implants, manufactured by Nobel Biocare. The Titanium Bases with screw for the CL-Series are indicated for Bone Level implants, manufactured by Straumann. The Titanium Bases with screw for the CN-Series are indicated for synocta implants, manufactured by Straumann. The Titanium Bases with screw for the CR-Series are indicated for Tapered Screwvent implants, manufactured by Zimmer. The Titanium Bases with screw for the CS-Series are indicated for OsseoSpeed implants, manufactured by Astra Tech. The Titanium Bases with screw for the CV-Series are indicated for Astra-Tech EV implants, manufactured by Dentsply.

Each Titanium Base is delivered with an abutment screw for fixation on the implant. The article number is the order number. Composition: Titanium Base and abutment screw made from titanium Ti6AI4V medical grade 5, ASTM 136. Instruction for clinician: Close cooperation between surgeon, restorative dentist, and dental laboratory technician is required for successful implant treatment. Abutment Direct Inc. titanium bases include an internal screw to attach the dental abutment to the dental implant. Please follow the recommended torch levels specific to the implantabutment combination in your Abutment Direct catalogue. If you do not have a catalogue, please contact 1-855-604-0465 to order our catalogue. We recommend that clinicians, new and experienced users, go through training on any new product concepts they encounter. Abutment Direct Inc. provides hands-on guidance to all customers. Contact your local Abutment Direct Inc. representative for more information. Contraindications: The Titanium Base with screw of each Series can only be combined with the matching implant, e.g. the CE-Series shall be combined exclusively with Nobel Replace implants. They cannot be combined with implants of a different implant type or manufacturer. The diameter of the Titanium Base must correspond in size to the used implant in order to prevent peri-implant tissue irritation. The Titanium Bases are indicated for single use only. If they are used multiple times, they might damage the implants. The 3.0mm platform Titanium Bases with screw for the CV-Series are only indicated for Mandibular incisors and Maxillary lateral incisors. Other uses are strictly prohibited and void all warranties. For fixation of the Titanium Base on the implant, the correct torque force, recommended by the implant manufacturer, has to be considered carefully to avoid the damage of the implant-bone connection. Ncm Abutment 20 CS-Series CC-Series 25 CV-Series CH-Series 30 CR-Series 35 CN-Series CE-Series CL-Series CF-Series CK-Series

Warnings: Dental implant surgery and the restoration of implants involve complex dental procedures that are not without risk. It is the obligation of the clinician to inform the patient about the nature and risk(s) of the procedure(s). Achievement of a satisfactory outcome requires appropriate training prior to implant system use. Improper technique and/or inadequate training can lead to implant/abutment failure and/or loss of supportive bone. Dental implants and prosthetics systems may only be used by dentists or physicians who have had appropriate education and training. Proper clinical and radiographic evaluation of the patient should be performed prior to any implant placement. Implants or abutments can break in function for any number of reasons. It is important that the clinician use an adequate number of implants in order to provide support to, and distribute the load between, the abutments. Implants should not be placed if there is not sufficient alveolar bone width and height to surround and sustain the implant. Abutments are provided in a non-sterile state and are intended for single use only. Under no circumstances should re-use be attempted. For Laboratory Technician: Do not inhale dust and vapours when machining Ensure suitable air extraction/ventilation at the workplace and corresponding Machinery. -Mechanical treatment of the connection part of the Titanium Bases will damage the correct fitting of the Titanium Base to the matching implant. Handling Method: Ceramic Abutments: Milling with CAD/CAM-machines of zirconium oxide or aluminum oxide ceramics according to the anatomic form of a crown or coping. The Ceramic copings or crowns shall be milled or polished with a diamond instrument and with minimal pressure and water-cooling. The minimal thickness shall be 0.5mm sharp edges must be avoided. Veneering: Copings shall be veneered with appropriate ceramics before cementing onto the Titanium Base. The instructions for use of the ceramic manufacturers have to be considered. Treatment of the Titanium Base and the ceramic abutment before cementing: Sandblasting of the contact surfaces with AI2O3, 50um for intensive cleaning of dust and grease. It is recommended to protect the connection part of the Titanium Base with an implant analog during handling. Cementing:

It is recommended to cement the ceramic abutment onto the Titanium Base with Panavia F2.0(Kuraray) with RelayXUnicem (3M Espe) or other equivalent cements. The instructions for use of the cements shall be followed carefully. The Titanium Base shall be fixed onto an implant analog with the abutments screw. The head of the screw has to be covered with wax or resin. The mixed cement is applied onto the contact part of the Titanium Base. The abutment is pressed onto the Titanium Base. The final position is evaluated by slight rotation. The gap between abutment and the Titanium Base must be as small as possible. Remaining cement shall be removed immediately. Polishing: After hardening the remaining cement shall be removed with rotating silicon instruments. The cement inside the screw channel has to be removed carefully. Scan Body Indications: Scan Body: For the CAD/CAM scanning of the model, the scan body is used to indicate the position of the implant. The size of the scan body shall be corresponding to the original implant system, implant diameter and Titanium Base Series. The chamfer of the scan body prevents the rotation of the ceramic abutment. The scan body is fixed on the implant analog with the abutment screw. After correct positioning, there is no gap visible between implant and scan body. Rotation of the scan body is impossible. Article Number: The article number of scan body and scan base is a combination of the code for the Series: CE, CF, CC, CK, CV, CH, CL, CN, CR, and CS with the code 1400 for scan body. Warning: Metal dust is harmful to your health. When Milling and sandblasting use a suction extraction system and a breathing mask. Allergies to alloy or contents of the alloy or electrochemically base reactions may very rarely occur. Warranty: 10 years on the mechanical stability of the Titanium Base, if it was processed according to the Instructions for use. Whether given verbally, in writing or by practical instructions, our recommendation for use is based upon own experience and trials and can only be considered as standard values. Our products are subject to a constant further development. Therefore alterations in construction and composition are reserved. Cleaning, Disinfection and Sterilization: All prosthetic components are supplied in non-sterile condition.

Abutment Direct Inc. 102-7351 Victoria Park Avenue Markham, Ontario L3R 3A5 Tel: 1-905-604-0465 Fax:1-905-605-0900 Products indicated with are registered brand names of the manufacturers.