CPD Article ISSUE 33. Proud of our History, Looking Forward to the Future

Similar documents
The difference is obvious. Original components by Straumann

CPD Article ISSUE 42. Proud of our History, Looking Forward to the Future

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

the way to straumann cares abutments

CPD Article ISSUE 59. Proud of our History, Looking Forward to the Future

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

Straumann Dental System Indication-based prosthetic workflow. Technical Information

Product Information for Labs. etkon ident Perfectly versatile. Performance you can rely on.

Bridging the Gap Between Original and Multi-Platform Systems.

SIMPLANT Guided Surgery delivering restorative-driven implant treatment

Product Information. Straumann CARES Scan & Shape Turn into digital.

You design, we create.

PROSTHETIC EFFICIENCY. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance.

CHECK-UP Determination of Impression type & Method after implant placement

INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

More than a Ti-base. Your trusted link between implant and restoration. Straumann Variobase C. Variobase for CEREC becomes Variobase C

STRAUMANN CARES DIGITAL SOLUTIONS. CARES Implant Prosthetics Ultimate restorative flexibility.

STRAUMANN CARES CUSTOMIZED PROSTHETIC SOLUTIONS

Product Information. Straumann CARES Scan & Shape Turning into digital solutions.

Straumann Original Clinical Review. General Information

seamless connections

NobelProcera Product Overview

Description: Prosthetic Components for dental restoration under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series.

For technical assistance: Tel Working time: 8.30 am pm

CPD Article ISSUE 26. Proud of our History, Looking Forward to the Future. CPD Article Issue 26.indd 1 25/11/ :55

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle

Straumann Variobase for Bridge/Bar

Titanium Base abutments plus screw and associated restorative and dental laboratory components.

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

Product Information. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance. The NEW. Variobase family members

Being the partner of choice

cara I-Butment regular/angled They fit like real teeth.

More than pure esthetics. The natural and strong solution.

Lava. Scan ST Design System. The New World. of Integration

Rock your practice with digital restorations in a day.

More than Abutments. catalogue

PRE-MILLED ABUTMENTS COMPLETE SOLUTIONS

Simplant. Guided Surgery. delivering restorative driven implant treatment

A Clinician s Guide to Digital Dentistry Dental restorations through CEREC Connect with Absolute.

Stock Prosthetic Guide 2014

NobelProcera Implant Bar Overdenture complete range of fixed and removable solutions.

STRAUMANN CARES DIGITAL SOLUTIONS. CARES Implant Prosthetics Ultimate restorative flexibility.

Dual-Use Scan Bodies ID and Implant Configuration For itero. Precision manufactured by

Patient information on Straumann Dental Implants. More than a dental implant. A confident smile.

PRE-MILLED BLANK COMPLETE SOLUTION

Catalog. etkon ident Compatibles perfected. From a partner you can trust _etkon_iDent_Catalogue_nordic indd :56:11

The Lava System Perfectly Integrated for High-Precision Digital Dentistry

Straumann Dental Implant System. Fax Order Form Collection.*

» For multi-unit restorations -

Playing together seamlessly.

TRI + Digital Solutions EXOCAD MANUAL

Patient information on dental implants. More than just beautiful teeth. A new quality of life with dental implants.

SPECIALIST IN CUSTOMIZED PROSTHETICS

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

Straumann CARES Prosthetics. More than efficiency. Cost-effective workflow solutions.

Straumann. This is a real breakthrough. Roxolid implant, make the restoration, then go home and sleep well at night.

GC Manufacturing Europe

Laboratory Solutions. Optimization By Design

Being the partner of choice

Basic information on the. Straumann Pro Arch TL. Straumann Pro Arch TL

TRI + Digital Solutions 3SHAPE MANUAL

CAD/CAM Prosthetic Solutions

Average scan time is 1.40 minutes for a single crown. Non-contact, optical scanner with fringe projection triangulation for high accuracy

Digital workflows and Milling for dental labs.

FOR INTERNAL REFERENCE ONLY

The key to exceptional craft lies in exceptional materials.

BIOTECH DENTAL GROUP, 2.0 DENTAL OFFICE PARTNER.

SHAPE YOUR DENTAL FUTURE LABORATORY

Watson Dental Lab Fixed Hybrid Protocol

THE WORD Smart screw installation Access angle to implant screws

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

TRI + Digital Solutions DENTAL WINGS MANUAL

What s New. CARES Visual 12.1

Straumann CARES On 3Shape

LDAC Laboratory Designed Abutments For Competitive Systems. Precision Engineered

Straumann CARES On 3Shape

S-SERIES. compatible to: DENTSPLY Implants / Astra Tech Implant System OsseoSpeed TX. PLATFORM 3,5 / 4,0 mm 4,5 / 5,0 mm TITANIUM BASE

TruAbutment Digital Solutions

RELATIONSHIPS MATTER. Innovation, Expertise and. Craftsmanship. in Laboratory. Products and. Services for the. Dental Profession

SOLUTIONS. DentalWiz. extending the art of Simplantology, to your CAD /CAM restoration jobs, making it as simple as our implant systems.

CPD Article ISSUE 22. Proud of our History, Looking Forward to the Future


Straumann CARES Prosthetics More than efficiency. Cost-effective workflow solutions. Product Information

for individual abutment design large glue surface, so durable solid connection to the base conventional usable and also for CAD/CAM process

Hybrid Denture bridges have a well-documented history

A Clinician s Guide to Restoring Screw Retained Full Zirconia Implant Crowns.

About Bayshore. Bayshore Dental Studio is a Full Service Dental Laboratory ranked in the top 7% by LMT Magazine.

IMPLANT PROSTHETICS

Guidance for. implant removal. Straumann Dental Implant System

Dental Implants. Pricing Guide

Straumann CARES Prosthetics. More than efficiency. Cost-effective workflow solutions.

Soft Tissue Transfer Utilizing Digital Impressions of Anterior Implants

Patient information on dental implants. More than just beautiful teeth. A new quality of life with dental implants.

CARES D series. CARES M series. CARES Integrated Digital Solutions CARES In-Lab Milling. Product Information. Post Processing

STL. inside. ineos Blue: Precision, Speed and Control. THE SCANNER WITH Bluecam TECHNOLOGY

SPECIAL REPORT. The Top 10 Things to Know Before Choosing Your. Dentist

Transcription:

CPD Article ISSUE 33 Proud of our History, Looking Forward to the Future

BIDST CPD This learning session has been judged as being equivalent to one hour of verifiable CPD. To claim your verifiable CPD you will need to answer the questions at the end of this article and submit them either by email to secretary@bidst.org or by post to the BIDST Membership Office 44-46 Wollaton Road, Beeston ttingham NG9 2NR. You will also need to keep a copy of the article together with your feedback sheet and certificate for revalidation. 1hr Verifiable CPD Ref. 39/02/02 The Art of Abutment Selection Learning Objectives By reading this article you will learn: This article will guide technicians in understanding the need to use original implant components to meet the GDC standards for the dental team without compromising patient well-being when selecting implant abutments. Larry Browne DCP, ITI Fellow discusses the reasons why technicians should carefully consider their choice of implant abutment. Implant supported restorations are certainly here to stay and any practice or laboratory wishing to continue to be successful will need to incorporate an implant service option. Indeed there are a great many operators rushing into the market place, attracted by the simplicity of modern systems on offer and potentially simple technology. But is the reality as the marketing departments would have us believe? Or are there perhaps some complications that may turn up to undermine our newly-found confidence? There is much to learn in implant dentistry, particularly if you are working with multiple systems and all their options for hardware components. Undoubtedly the very best guarantee of trouble-free restoration is a thorough knowledge of the system and its requirements and protocols, and applying them to your work. Unfortunately there is a growing trend within our world for using third party CADCAM solutions or copy components, which are not in any way researched or indeed independently tested. Original Components While it may appear convenient or money saving to use third party component options, the integrity of fit and the load bearing potential has been shown, in several studies, to be lamentably poor. In a published study 1: Seong Kyun Kim et. Al. Inter. J of Maxillofacial Implants 2012:27:42:47, comparing CPD Article Issue 33 Page 2 three copycat systems against an original abutment, two of the copies fractured during the loading tests and all three copies fell very short indeed of a trouble-free expectation. Another study: 2. Michel Gigande et.al.clinical Implant Dentistry Relat. Res. E published, recommended that copy abutments should not be considered as they seem not to perform as the original abutment to original implant comparison. Initially, of course, all of the copies appeared to be very similar to the original and to the naked eye seemed good enough to use. Fig 1 illustrates screw-loosening with interchangeable abutments in internally connected implants after cyclic loading. Kim et al. Int J Oral Maxillofac Implants 2012; 27:42 47. Fig 1. 1 Straumann SLA RN 4.1 Straumann Solid abutment 2 Straumann SLA RN 4.1 Lifecore Biomedical Restore, Inc RDS COC abutment 3 Straumann SLA RN 4.1 Neobiotech Neoplant solid abutment 4 Straumann SLA RN 4.1 Osstem AVANA solid abutment The abutments were connected to the implants at 35

Ncm before loading. The original Straumann connection shows the highest removal torque* after cyclic loading reflecting the smallest effect of screw loosening. *Results for Straumann abutments on Straumann implants are statistically different from those with non-original parts. Conclusion: Although different abutments are interchangeable with each other, they possess different chemical compositions and physical characteristics. The use of an abutment and implant manufactured by the same company is recommended to prevent the loosening of the abutment screw. The trouble is that without scientific testing equipment the clinician or technician cannot possibly know the validity of the copy systems and as such should, in my opinion, not even think of using them. The main arguments are either cost savings or convenience, and despite the fact that any patient guarantee is immediately negated, many continue to ignore the patients interests. Today as registrants of the GDC and the requirement for professional standards, many technicians, and indeed clinicians, who should know better, are completely discounting considerations such as patient interest and disclosure and instead are following the prices guide or the persuasive marketing hype. CADCAM and Scanning Technology Whilst using a scanner for a bespoke abutment has almost become the norm for many people, unfortunately none of the scanning companies are able to guarantee the integrity of the manufactured component for another system. This means that any breakdown will be the responsibility of the technician, who is, under the recent registration rules, responsible directly to the patient. What is worrying is that in many cases otherwise responsible and committed technicians are creating third party copies because they have invested in one manufacturer s scanning system to use as their CADCAM option without realising that their components will not and do not meet the criteria of other system manufacturers. This also negates any patient guarantees. Unless they have research data to support their choice, any failure will land on their doorstep and reflect a lack of professional standards, which might be of interest to the GDC. Fig 2 illustrated the mean rotational misfit of Implants with original and non-original abutment connections*. Gigandet et al. Clin Implant Dent Relat Res. 2012 Jul 16 Fig 2. 1 Straumann BL NC 3.3 Roxolid Straumann CARES Ti abutment 2 Straumann BL NC 3.3 Roxolid Astra Tech ATLANTIS Ti abutment 3 belreplace Straight 3.4 NP belprocera Abutment Ti 4 Astra Tech OsseoSpeed TX 3.5 S Astra Tech ATLANTIS Ti abutment The original Straumann connection shows the smallest rotational misfit**. * For further results of the study see the original publication. ** All results are statistically different. Conclusion: n-original abutments differ in design of the connecting surfaces and material and demonstrate higher rotational misfit. Some of the leading manufactures are trying to make access to original custom abutments easier for laboratories and Straumann have recently launch their Scan & Shape service to give all labs, and consequently dentists, the ability to produce a range of original custom abutments without the need to invest in scanning technology. The lab simply sends a model or waxed-up abutment with the required design specifications to Straumann, and based on this design, the lab will receive an original Straumann CARES Abutment. Centrally milled Straumann CARES abutments are returned to the lab ready to prepare the final restoration, eliminating the need to use stock abutments that require modification. Additionally, Straumann CARES Abutments in Zirconium Dioxide allow direct veneering for screw-retained restorations and eliminate the need for additional copings. This service provides custom abutments that achieve highquality prosthetic outcomes using original components designed to achieve excellent performance of the implant- CPD Article Issue 33 Page 3

abutment connection. Thorough knowledge of your chosen implant system is essential to maximise the success of all your implant restorations and to help you discuss all the potential options with your clinical colleagues. Unfortunately many technicians are not keeping up to date with advances in implant abutment options and consequently choosing the familiar rather than the most suitable. The manufacturers are not stupid and are very well aware of the sensitivity to cost in the marketplace. Consequently in recent years many have added appropriate additional options, which do not undermine the protocols. The technician has a duty to be aware and up to date with such choices and in a position to offer them when required. I was recently involved in a project which compared the laboratory cost of an off-the-shelf option to the bespoke CADCAM or indeed the UCLA type abutment for a single cementable crown. The variation due to the choice of abutment alone was 172.00. This cost control is easily within the hands of the up-to-date and trained technician who is familiar with the abutment choices and able to select the most suitable and cost-effective option. Straumann have recently launched a very versatile and cost-effective abutment solution; the Straumann Variobase Abutment, which should be of interest to any technicians seeking to use original components, whilst still maintaining cost control. This new abutment can be used on either Bone level or Tissue level implants and delivers a highly cost-effective solution for screw- or cement-retained single crowns and cementretained bridges. Consisting of a customised coping and a machined abutment with four cams to significantly enlarge the bonding surface, the final restoration of choice is bonded in the lab to the abutment with a high degree of accuracy, ready to be screwed in to place by the clinician. Fig. A) Comparing the rotational misfit between original abutments on original implants and non-original abutments on original implants. Fig. 1: Straumann Variobase Abutment with coping on Straumann RC 4.1 implant Fig. 2: Straumann Variobase Abutment with coping on Straumann WN 4.8 implant Fig. 3 + 4: Enlarged bonding surface compared to cylindrical design allows the design to have minimal dimensions providing maximum design flexibility Cost Comparison The table below illustrates that it is possible to use original components and still maintain cost control. Abutment Type Straumann Variobase Stock Abutment - Metal Coping Straumann Variobase Stock Abutment - Digital Zirconia Coping Cost 88 112 Titanium CARES Abutment 138 Anatomic BL/Angled TL Abutment 169 Gold Abutment 282 - Estimation of 3gms of gold @ 15 per gram Final conclusions 282 Today s best implants systems are reporting 98+% success rates, based on published research over 10 years. Component failure with these systems is very rare, however it is certain that using mismatched components will lead to a significant increase in the potential risk of failure and this is something I would not consider doing, even at the request of a clinician. *Implants with original and non-original abutment connections Michel Gigandet, med. dent; Gianni Bigolin; Francisco Faoro; Walter Bürgin, biomed. eng; Urs Brägger, Prof. Dr. med. dent. Clin Implant Dent Relat Res. 2012 Jul 16, Epub ahead of print belprocera and belreplace are registered trademarks of bel Biocare, Switzerland. OsseoSpeed and Atlantis are registered trademarks of Astra Tech Dental, Sweden. Straumann and/or other trademarks and logos from Straumann mentioned herein are the trademarks or registered trademarks of Straumann Holding AG and/or its affiliates. CPD Article Issue 33 Page 4

CPD Questions Ref. 39/02/02 Issue 33 To claim your verifiable CPD you will need to answer these questions and submit them either by email to secretary@bidst.org or by post to the BIDST Membership Office 44-46 Wollaton Road, Beeston ttingham NG9 2NR. You will also need to keep a copy of the article together with your feedback sheet and certificate for revalidation. Q1.) In which study did the copycat abutments fracture during load tests? Q5.) If CADCAM is used to create an abutment, does this meet the manufacturer s specifications? All CADCAM milled abutments meet the manufacturer s specifications Only if milled by the original manufacturer s of the implant CADCAM milled abutment meet the required standard Seong Kyun Kim et. al. Inter. J of Maxillofacial Implants 2012:27:42:47 Ho Lin et. al. Inter. J of Maxillofacial Implants 2012:27:42:49 Shinying Choi et. al. Inter. J of Maxillofacial Implants 2012:27:42:50 Q6.) Are you contravening the GDC Standards for the Dental Team by using anything other than an original implant component? Don t know Q2.) Which study cited that copycat abutments should not be considered? Michel LeGrande et.al. Clinical Implant Dentistry Relat. Michel Boschert et.al. Clinical Implant Dentistry Relat. Michel Gigande et.al. Clinical Implant Dentistry Relat. Q7.) Which service offers the production of original CADCAM abutments without the need to purchase a CAD scanner? Scan Direct Straumann Scan & Shape Scan and Go Q3.) Which research discussed screw loosening of abutments? Tim et al. Int J Oral Maxillofac Implants 2012; 27:42 47 Kim et al. Int J Oral Maxillofac Implants 2012; 27:42 47 Dim et al. Int J Oral Maxillofac Implants 2012; 27:42 47 Q4.) If you use non-original system abutments, are manufacturer s warranties valid? Don t know Q8.) What is the cost difference between a Straumann Variobase Stock Abutment with a metal coping and Gold abutment? 250 200 194 Q9.) Should a technician use a non-original component at the request of a clinician to save money? t sure CPD Article Issue 33 Page 5

CPD Questions Ref. 39/02/02 Q10.) In the opinion of the author, do mismatched components potentially lead to implant failure? t sure Name: GDC Number: Address: Postcode: Telephone no: (in case of any queries) Signed: 44-46 Wollaton Road, Beeston, ttingham NG9 2NR Telephone: +44(0)115 968 3181 Fax: +44(0)115 925 4800 Website: www.bidst.org Email: secretary@bidst.org Date: CPD Article Issue 33 Page 6