Rotating Platform. stabilityinmotion

Similar documents
Fixed Bearing. stabilityinmotion

BALANCING THE PATIENT NEED FOR FREEDOM OF MOVEMENT AND JOINT STABILITY

THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM

STABILITY & MOTION VS. THE PERSONA KNEE SYSTEM. The Zimmer Persona Knee

THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM

ATTUNE KNEE SYSTEM: SOFCAM CONTACT

ATTUNE KNEE SYSTEM 25% 25% 25% 25% VALUE ANALYSIS BRIEF VALUE SUMMARY UNMET NEEDS IN TOTAL KNEE ARTHROPLASTY

ATTUNE Knee System: Stability in Total Knee Replacement

ATTUNE Knee System: Cruciate Sacrificing Fixed Bearing

LAMINA SPREADER SURGICAL TECHNIQUE

NexGen Legacy LPS-Flex Knee. Brochure

RESECTION GUIDE SYSTEM. TRUMATCH Personalized Solutions Surgical Technique with ATTUNE Knee INTUITION Instruments

Approach Patients with CONFIDENCE

HP KNEE EXTRACTION Instrumentation. Product Overview

Rotating Platform System. Product Rationale

ATTUNE KNEE SYSTEM 30% 30% 20% 20% VALUE ANALYSIS BRIEF VALUE SUMMARY BENEFITS OF TOTAL KNEE ARTHROPLASTY (TKA) UNMET NEEDS IN TKA

INSTRUMENTS. Design Rationale

INSTRUMENTS. Product Rationale

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)

Tibial Base Design Factors Affecting Tibial Coverage After Total Knee Arthroplasty: Symmetric Versus Asymmetric Bases

Optimum implant geometry

HP Knee Extraction Instrumentation. Product Overview

Evolution. Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee. Key Aspects

ATTUNE KNEE SYSTEM 25% 25% 25% 25% VALUE ANALYSIS BRIEF VALUE SUMMARY UNMET NEEDS IN TOTAL KNEE ARTHROPLASTY

Knee Revision. Portfolio

DATA & RESEARCH OVERVIEW

Fixed and Variable Geometry Total Shoulder Arthroplasty

Product Rationale. Where Strength and Modularity Connect

Estimating Total Knee Arthroplasty Joint Loads from Kinematics

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

Saiph Knee System. Technical Dossier

Bone Preservation Stem

itotal Customized POSTERIOR-STABILIZED knee replacement system

CUTTING GUIDE SYSTEM PRODUCT RATIONALE. Custom-Made Patient Instruments for Total Knee Replacement

Approach Patients with Confidence

THE P.F.C. SIGMA FEMORAL ADAPTER. Surgical Technique

Optimum implant geometry

Think isometry Feel balance

PIN GUIDE SYSTEM SURGICAL TECHNIQUE. with the SIGMA High Performance Instruments System. This publication is not intended for distribution in the USA.

U2 PSA. Revision Knee. Surgical Protocol

ConforMIS, Inc. 28 Crosby Drive Bedford, MA Phone: Fax:

Aseptic Revision Total Knee Surgical Techniques. Andrew Ehmke, DO Chicago, IL May 5, 2018

Pin Guide System. Surgical Technique

Featuring. Technology. Product Rationale

Mako Partial Knee Patellofemoral

Vanguard 360 Revision Knee System. Design Rationale

LPS SYSTEM POCKET GUIDE

Constrained Posterior Stabilized (CPS) Surgical Technique

JOINT RECONSTRUCTION PORTFOLIO OVERVIEW

PINNACLE REVISION CUP SYSTEM

Consistency in U2 Knee System over Time

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

Constrained Posterior Stabilized (CPS)

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

AML Hip System. Design Rationale/ Surgical Technique

Trabecular Metal Tibial Cone Surgical Technique

Zimmer Segmental System

Luminus Flex Total Knee System (Fixed Type) The Innovative Technology for Knee Replacement

Distal Cut First Femoral Preparation

ANATOMIC LOCKED PLATING SYSTEM

B i co m pa r t m e n ta l Knee Ar t h r o p l a s t y. Surgical Technique Overview

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

Approach Patients with Confidence

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

Mako Partial Knee Medial bicompartmental

Biomechanical Effects of Femoral Component Axial Rotation in Total Knee Arthroplasty (TKA)

This publication is not intended for distribution in the USA.

A Systematic Review on Performance of the Vanguard Complete Knee System

Vanguard Complete Knee System

ZIMMER NEXGEN CRUCIATE RETAINING (CR) AND LEGACY KNEE POSTERIOR STABILIZED (LPS) TRABECULAR METAL MONOBLOCK TIBIAS. Surgical Technique Addendum

NexGen CR-Flex and LPS-Flex Knees. Design Rationale

Correlation of Femoral Component Micromotion to a Physical Test Using an FEA Model.

Correlation between Knee Kinematics and Patello-femoral Contact Pressure in Total Knee Arthroplasty

Optimum implant geometry

TOTAL KNEE ARTHROPLASTY (TKA)

Intramedullary Tibial Preparation

Specifications guide ECHELON. Hip System

NEUFLEX MCP/PIP FINGER JOINT IMPLANT SYSTEMS SURGICAL TECHNIQUE. This publication is not intended for distribution in the USA.

SIGMA High Performance Partial Knee. Unicondylar. Surgical Technique

Impact of Intramedullary Reaming Depth on Establishing Femoral Canal Axis in the Sagittal Plane

The challenge. Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery

S h o u l d e r Solutions by Tornier C o n v e r T i b l e S h o u l d e r S y S T e m

SUMMIT and DURALOC. Clinical Summary

CHARNLEY Wires. Surgical Techniques

STIFFNESS AFTER TKA PRE, PER AND POST OPERATIVE CAUSING FACTORS

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

PFNA. With Augmentation Option.

The information contained in this document is intended for healthcare professionals only.

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

9800 Metric Blvd. Austin, Texas

Patient-specific bicompart mental knee resurfacing system

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Femoral Revision Algorithm. A practical guide for the use of the CORAIL Hip System in femoral revision surgery

HIGH FLEXION IN CONTEMPORARY TOTAL KNEE DESIGN: A PRECURSOR OF UHMWPE DAMAGE? A FINITE ELEMENT STUDY

RECLAIM REVISION HIP SYSTEM

The Bodycad Unicompartmental Knee System THE PURSUIT OF ORTHOPAEDIC PERFECTION

EXACTECH KNEE. Operative Technique ADDENDUM. Metaphyseal Cones. Surgeon focused. Patient driven. TM

THE PERSONALIZED KNEE

CLINICAL FINDINGS USING THE VERASENSE KNEE SYSTEM THE INTELLIGENT CHOICE FOR FLEXION STABILITY

Transcription:

Rotating Platform stabilityinmotion

BRINGING PATENTED TECHNOLOGIES TO A SEAMLESS SYSTEM, FROM PRIMARY THROUGH REVISION The ATTUNE Revision Rotating Platform Knee System is a comprehensive system that is designed to enable you to effectively manage a broad range of complex primary and revision knee procedures. ATTUNE Primary Knee System Breakthrough discoveries and proprietary technologies, clinically proven to address patient needs for stability and motion 1

The Revision Femoral Component is compatible with the ATTUNE Revision Rotating Platform Tibial Insert and the ATTUNE Posterior Stabilized (PS) Rotating Platform Insert. ATTUNE Revision Rotating Platform Knee System Comprehensive range of solutions that are designed to address the main challenges presented in complex primary and revision surgery: loosening, instability, and OR efficiency 2

ADDRESSING LOOSENING THROUGH FIXATION AND PATIENT FIT

Bone Defect Compensation Tibial and Femoral Metaphyseal Sleeves feature a stepped design to compensate for substantial bone defects, compressively load the bone and provide a solid foundation for implant fixation. 360 Offset Capability Offset options of 2, 4, and 6 mm with orientation available from 0 to 360 increase patient fit in femoral anatomical variations, as well as adjustment for soft-tissue deficiencies. Rotational Freedom The ATTUNE Revision Cam/Spine interface is designed to provide +/- 1.25 varus/valgus constraint while allowing internal/external rotational freedom through the Rotating Platform (RP) design during the full range of motion. Improved Stem Geometry The Press-Fit Stems are designed to provide rotational stability and create a balance between stiffness and flexibility to reduce stress associated with end-of-stem pain compared to prior designs supported in this study. 3

Closing The Flexion Gap The ATTUNE Revision Femoral Boss is designed to best fit a patient s natural anatomy through optimal placement in terms of flexion gap balance, bone coverage and valgus angle. The ATTUNE Revision Femoral Component has 1 mm additional posterior thickness, the same as the ATTUNE PS Femoral Component, to help close the flexion gap. REDUCING INSTABILITY THROUGH IMPROVED KINEMATICS Femoral-to-Insert Size Matching The Rotating Platform technology enables the Femoral Component and Tibial Insert to match size-to-size every time, allowing for optimization of the tibiofemoral contact mechanics and stability throughout the range of motion. Additionally, it is designed to accommodate 2-up and 2-down sizing between the Tibial Insert and Tibial Base. 4,5,6

Enhanced Tibiofemoral Conformity ATTUNE GRADIUS Curve technology allows for enhanced tibiofemoral conformity where the gradually reducing femoral radius provides a smooth transition through the gait cycle. 4,5,7 Femoral Offset 360 offset capability with 2, 4, and 6 mm options on the Femoral Component developed to enable balancing the flexion gap while providing improved fixation and patient fit. Tibio-femoral Sagittal Conformity (Conformity Ratio - R femoral /R insert ) 7 0 30 60 90 120 ATTUNE Revision Femoral Component with ATTUNE Revision RP Tibial Insert 0.99 0.81 0.66 0.45 0.38 ATTUNE Revision Femoral Component with ATTUNE Primary PS RP Tibial Insert 0.99 0.81 0.66 0.45 0.38 SIGMA TC3 Femoral Component with TC3 RP Tibial Insert 0.99 0.99 0.61 0.61 0.61 SIGMA TC3 Femoral Component with Primary PS RP Tibial Insert 0.99 0.99 0.61 0.61 0.61 ATTUNE Primary PS Femoral Component with ATTUNE Primary PS RP Tibial Insert 0.99 0.81 0.66 0.45 0.38

OR EFFICIENCY WITH STREAMLINED WORKFLOWS Cut Through Trials Cut Through Trials allow for efficiently setting rotation and balancing flexion and extension gaps in real-time. Cut Through Trials also have the ability to make Femoral Augment and Box resections and assemble the Augment and Box Trials without being removed. Real-time Gap Assessment with Conventional Cut Guide Conventional Cut Guides allow for assessing the anterior resection level, flexion gap, and M/L fit simultaneously by fine-tuning the femoral offset position in 360. Additionally, Conventional Cut Guides replicate the distal thickness of the femoral implant, enabling assessment of extension gap before making bone resections.

Consistent Sleeve Preparation Ream, broach, cut. Consistent Sleeve preparation promotes surgical technique efficiency. Both the Tibial and Femoral Sleeves are available in three options, cemented as well as Partially and Fully POROCOAT Porous Coated options. Additionally, each Femoral Sleeve distalizes the joint line by 4 mm, matching the size increments of the Femoral Distal Augments. Smart Kitting Instrumentation kitted for streamlined surgical workflows while enabling management of a broad range of complex primary and revision knee procedures.

CONTINUING TO BALANCE THE PATIENT NEED FOR FREEDOM OF MOVEMENT AND JOINT STABILITY The ATTUNE Knee System is designed to provide patients with STABILITY IN MOTION, offering a comprehensive range of implant solutions that address overall patient satisfaction. In a large multi-center study, the ATTUNE Primary Knee System demonstrated improved outcomes across a broad range of Patient Reported Outcome Measures (PROMs) compared to certain existing knee brands at one year minimum follow-up. 1 The same technologies that have helped deliver these outcomes in primary are also incorporated in the ATTUNE Revision System. These features are designed to help address patients who are not satisfied after knee revision surgery, which ranges from 27% to 38%. 8

GLIDERIGHT Articulation The GLIDERIGHT Articulation encompasses a trochlear groove designed to accommodate patient variation and soft tissue interaction, and patella components designed to optimize patella tracking while maintaining bone coverage. 9 ATTUNE GRADIUS Curve The patented ATTUNE GRADIUS Curve is a gradually reducing femoral radius designed to provide a smooth transition from stability to rotational freedom through a patient s range of motion. 4,5,7 SOFCAM Contact The Revision Tibial Inserts and Revision Femoral Component have taken into account the advantages of SOFCAM Contact while considering the requirements for constraint in the Revision Construct throughout the range of motion. The kinematics for the Revision Femoral Component on the Revision Rotating Platform Insert are the same as the Revision Femoral Component on the Primary PS RP Insert. 10 The controlled engagement of the Cam to the Insert Spine provides a smooth transition in tibio-femoral conformity through a patient s range of motion. Rotating Platform and Sleeves The ATTUNE Revision Rotating Platform Tibial Base and Sleeve technologies have been designed based on the successful clinical heritage of the legacy DePuy Synthes SIGMA TC3 RP and M.B.T. Revision Knee Systems.

References: 1. Hamilton, W.G., Brenkel, I., Gibbon, A., Kantor, S., Clatworthy, M., Dwyer, K., Himden, S., Lesko, J. (2017). Early outcomes with a new primary total knee arthroplasty (TKA) system vs. contemporary TKA: Interim results of two worldwide, multi-center prospective studies. American Academy of Orthopaedic Surgeons, Poster 106. Study comparators included the SIGMA Knee (89%), Triathlon (7%), NexGen (3%), and Other (1%). 2. Schroer, W.C., Berend, K.R., Lombardi, A.V., Barnes, C.L., Bolognesi, M.P., Berend, M.E., Ritter, M.A., Nunley, R.M. (2013). Why are total knees failing today? Etiology of total knee revision in 2010 and 2011. The Journal of Arthroplasty, 28 Suppl. 1: 116-119. 3. Leszko F., Gohsh, U., Heldreth, M., Barrett, D. (2014). The Effects of Different Revision TKA Stem Design on Bone Stress Distribution: FEA Comparative Study. 7th World Congress of Biomechanics, Poster F143. 4. Clary, C.W., Fitzpatrick, C.K., Maletsky, L.P., Rullkoetter, PJ. (2012a, February). Improving dynamic mid-stance stability: an experimental and finite element study. ORS Annual Meeting, Poster #1044. 5. Clary, C.W., Fitzpatrick, C.K., Maletsky, L.P., Rullkoetter, PJ. (2013). The influence of total knee arthroplasty geometry on mid-flexion stability: an experimental and finite element study. Journal of Biomechanics, 46:1351-1357. 6. Fitzpatrick, C.K., Clary, C.W., Rullkoetter, PJ. (2012a). Post-cam engagement during dynamic activity with current posterior-stabilized TKR. 18th Congress of the European Society of Biomechanics (ESB), 1700: 29. 7. Fitzpatrick, C.K., Clary, C.W., Rullkoetter, PJ. (2012b, February). The influence of design on TKR mechanics during activities of daily living. ORS Annual Meeting, Poster #2034. 8. Greidanus, N.V., Peterson, R.C., Masri, B.A., Garbuz, D.S. (2011). Quality of life outcomes in revision versus primary total knee arthroplasty. The Journal of Arthroplasty, 26(4): 615-620. 9. Clary, C.W., Wright, A.P., Komosa, M.C., Maletsky, L.P. (2012b). The effect of patella medialization on patellofemoral kinematics after total knee replacement. 18th Congress of the European Society of Biomechanics (ESB), 29: 1262. 10. Shalhoub, S., Fitzwater, F., Dickinson, M., Clary, C.W., Maletsky, L.P. (2016). Quantifying the change in tibiofemoral kinematics between primary and revision total knee arthroplasty inserts. International Society for Technology in Arthroplasty (ISTA) Annual Meeting. DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN 46582 USA Tel: +1 (800) 366-8143 Fax: +1 (800) 669-2530 www.depuysynthes.com DePuy International, Ltd. St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) 113 270 0461 DePuy (Ireland) Loughbeg, Ringaskiddy Co. Cork, Ireland Tel: +35 (321) 491 4000 Fax: +35 (321) 491 4199 DePuy Synthes 2017. All rights reserved. DSUS/JRC/0617/2181