Biodesign E NTEROCUTANEOUS FISTULA PLUG

Similar documents
MOVE BEYOND. to new hope for enterocutaneous fistulas. Enterocutaneous Fistula Repair

The Strong New Choice MILLION. From A Provider. You Already Know

Colorectal procedure guide

PERMACOL IMPLANT EVIDENCE SUMMARY

Regenerative Tissue Matrix in Treatment of Wounds

Move beyond to Biodesign.

7/2/2015. Incidence. *Mudge M et al, Br. J. Surg, 1985, 72:70-71

CorMatrix ECM Bioscaffold

THE BEST OF TISSUE REGENERATION FOCUSED ON PATIENTS NEEDS

2017 Americas Hernia Society Quality Collaborative Foundation. All rights reserved.

Name of Policy: Plugs for Fistula Repair

Background. K. C. Sasse 1 J. H. Lambin 1 J. Gevorkian 1 C. Elliott 1 R. Afshar 1 A. Gardner 1 A. Mehta 1 R. Lambin 1 L. Peraza 1

OptiFix Absorbable Fixation System

PAPER. Short-term Outcomes With Small Intestinal Submucosa for Ventral Abdominal Hernia

The lateral incisional hernia: anatomical considerations for a standardized retromuscular sublay repair

Postoperative Surgical Site Infection after Incisional Hernia Repair: Link to Previous Surgical Site Infection? Zulfiqar Ali, AG Rehan

Plugs for Anal Fistula Repair. Populations Interventions Comparators Outcomes Individuals: With anal fistula(s)

Repair of a laparostomy using biological mesh, topical negative pressure therapy and skin graft

Surgery and Crohn s. Crohn s Disease 70 % Why Operate? Complications of Disease. The Gastrointestinal Tract. Surgery for Inflammatory Bowel Disease

10/13/2016 FISTULAS. Outcomes

STOMA SITING & PARASTOMAL HERNIA MANAGEMENT

Plugs for Fistula Repair. Description

REINFORCED BIOSCAFFOLDS

Early View Article: Online published version of an accepted article before publication in the final form.

REVISED DATE: 07/19/12, 06/20/13, 05/22/14, 04/16/15, 03/17/16, 03/16/17, 03/15/18 POLICY NUMBER: CATEGORY: Technology Assessment

Bone augmentation with biomaterials

Difficult Abdominal Closure. Mark A. Carlson, MD

Bone augmentation with maxgraft

Management of the Open Abdomen

Laparoscopic Repair of Inguinal Hernia with Biomimetic Matrix

Current Surgical Management of Enterocutaneous Fistulas

LOWERING THE PROFILE RAISING THE BAR

Full incorporation of Strattice Reconstructive Tissue Matrix in a reinforced hiatal hernia repair: a case report

Abdominal wall reconstruction with components separation and mesh reinforcement in complex hernia repair

Strength and Predictability. Zimmer Collagen Repair Patch

INSTRUCTIONS FOR USE FOR:

Index. Note: Page numbers of article title are in boldface type.

Definitive Surgical Treatment of Infected or Exposed Ventral Hernia Mesh

Allograft Based Breast Reconstruction: Opportunity for a Second Look

Talent Abdominal Stent Graft

Neurosurgery is complex. DuraGen is the simple choice.

THE CRITICAL COMPLCATIONS AND MANAGEMENTS AFTER PANCREATIC SURGERY 2013/12/21

Access More Patients. Customize Each Seal.

2015 General Surgery Survival Guide

Management of Acute Intestinal Failure. HIFNET and Parenteral Nutrition Keith Gardiner Consultant Colorectal Surgeon Royal Victoria Hospital, Belfast

Medical management of EC fistula. Dr Simon Gabe Consultant Gastroenterologist St Mark s Hospital

Surgical Management of IBD in the Age of Biologics

Pelvic Prolapse. A Patient Guide to Pelvic Floor Reconstruction

Ventralex ST Hernia Patch featuring Sepra Technology

Surgical Management of CBD Injury Jin Seok Heo

Nutritional Management in Enterocutaneous fistula Dr Deepak Govil

A New EVAR Device for Infrarenal AAAs

Medical Policy Plugs for Fistula Repair Section Effective Date Subsection Original Policy Date Next Review Date Description

Artist s rendering. Count on STRATTICE. The Most Clinically Studied Biological Mesh for Complex Abdominal Wall Repair

Modern Management of the Open Abdomen A Cautionary Tale. Grand Rounds December 16, 2010 SUNY, Downstate

LONG TERM OUTCOME OF ELECTIVE SURGERY

Colonic Metal Stents MAKING A DIFFERENCE TO HEALTH

ORIGINAL ARTICLE. Multi-institutional Experience Using Human Acellular Dermal Matrix for Ventral Hernia Repair in a Compromised Surgical Field

Tissue engineering of cartilage

3/21/2011. Advances in laparoscopic ventral hernia repair. Laparoscopic approach well-suited for simple hernias:

A Comparative Study between Onlay and Pre Peritoneal Mesh Repair in Management of Ventral Hernias

Endoscopic management of sleeve leaks

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Hybrid mesh for sports hernia repair

Next Generations Native RVOT Valves

Imaging findings in complications of bariatric surgery.

Ancillary Components with Z-Trak Introduction System

Reconstitution of the anterior abdominal wall RECONSTRUCTIVE

Sure closure skin stretching system, our clinical experience

INNOVATIVE PRODUCTS G, J AND GJ-TUBES WITH ENFit TM CONNECTION

Current concepts in Critical Care Nutrition

Mesh Performance in Hernia Repair in 2017: A Surgical Review of Progress to Improve Outcomes

Positioning System. Laparoscopic ventral hernia repair KEY BENEFITS SOFT TISSUE REPAIR

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

Ventral Hernia Repair

PATIENT BOOKLET MEDTRONIC MITRAL AND TRICUSPID HEART VALVE REPAIR

Biliary Metal Stents MAKING A DIFFERENCE TO HEALTH

DURABLE. CONSISTENT. SAFE. IN.PACT Admiral Drug-Coated Balloon

The Emergency Hernia or The call you don t want at 2:00 a.m.*

Integra. PriMatrix Dermal Repair Scaffold PATIENT INFORMATION. Questions? Contact us: Clinician: Phone #: In case of emergency, dial 9-1-1

Enteral Feeding Access: Your BFF or Frenemy?

Treatment is aimed at repairing the fistula without compromising continence.

Colostomy & Ileostomy

II.- PLUG. NAME of the products. Premilene Mesh Plug MANUFACTURER. B Braun DESCRIPTION. Polypropylene mesh for plug technique

Considerations for a Durable Repair

Open abdomen in trauma. Ari Leppäniemi Abdominal Center Meilahti hospital University of Helsinki Finland

Homayoon Akbari, MD, PhD

Ventral Hernia Repairs: 10 year Single Institution Review at Thomas Jefferson University Hospital

Consumer summary. Endoscopic modified Lothrop procedure for the. treatment of chronic frontal sinusitis

Endoscopic Treatment of Luminal Perforations and Leaks

The Role of Surgery in Inflammatory Bowel Disease. Cory D Barrat, MD Colon and Rectal Surgeon Mercy Health

Acute dissections of the descending thoracic aorta (Debakey

Interesting Case Series. Omental Flap for Thoracic Aortic Graft Infection

Versatility and Proven Safety

Biologic grafts for ventral hernia repair: a systematic review

The first stents designed for use in the biliary tree and

Diagnosis and Management of Parastomal Hernias

LAPAROCELI: LAPAROSCOPY LIVE SURGERY PARASTOMAL HERNIA: WHAT TO DO? OSPEDALE DI PORTOGRUARO U.O.C. CHIRURGIA GENERALE FRANCESCO FIDANZA

Arteriovenostomy for renal dialysis 39.27, 39.42

Enterocutaneous fistula: Are treatments improving?

Transcription:

Offer a new alternative to patients who have enterocutaneous fistulas, even after standard treatments have been tried. Illustration by Lisa Clark Biodesign E NTEROCUTANEOUS FISTULA PLUG MEDICAL

How is Biodesign different? Other biologic grafts Cross-linked biologic grafts Cross-linked biologic grafts inhibit remodeling and vascular ingrowth, and have been associated with chronic inflammation and encapsulation. 1 Dermis-based biologic grafts Dermis-based biologic grafts contain high amounts of elastin. Over time, this elastin remains in the patient s body. The elastin can stretch and possibly lead to failure. 2 1. Novitsky YW, Rosen MJ. The biology of biologics: basic science and clinical concepts. Plast Reconstr Surg. 2012;130(5 Suppl 2):9S-17S. 2. Gupta A, Zahriya K, Mullens PL, et al. Ventral herniorrhaphy: experience with two different biosynthetic mesh materials, Surgisis and Alloderm. Hernia. 2006;10(5):419-425.

Remodel patient tissue. Biodesign is a non-cross-linked, non-dermis-based biologic graft technology that is completely remodeled into strong, well-vascularized tissue. 3 Non-cross-linked biologic grafts Biodesign material has been designed to maintain strength throughout the remodeling process, so there is no need for cross-linking. And because Biodesign material is remodeled completely into strong, vascularized tissue, it can provide a strong repair without a permanent material. 3 Non-dermis-based biologic grafts Biodesign material is non-dermis-based, so it does not contain meaningful amounts of elastin. 4 As a result, the body completely remodels Biodesign material into patient tissue that has an organized deposition of collagen. 3 3. Franklin ME Jr, Treviño JM, Portillo G, et al. The use of porcine small intestinal submucosa as a prosthetic material for laparoscopic hernia repair in infected and potentially contaminated fields: long-term follow-up. Surg Endosc. 2008;22(9):1941-1946. NOTE: The name Surgisis has changed to Biodesign since the printing of this article. 4. Heise RL, Ivanova J, Parekh A, et al. Generating elastin-rich small intestinal submucosa-based smooth muscle constructs utilizing exogenous growth factors and cyclic mechanical stimulation. Tissue Eng Part A. 2009;15(12):3951-3960.

Biodesign E NTEROCUTANEOUS FISTULA PLUG Enterocutaneous fistulas can significantly affect patient health and quality of life. Cook s Biodesign Entercutaneous Fistula Plug is specifically designed to correct this notoriously difficult and often debilitating condition where closure cannot be achieved by using conservative therapies. The molnar disk ensures that the Biodesign material and the plug remain positioned throughout the tract. Biodesign material is designed to be remodeled by the body when suitable conditions are established.* 4 or 7 mm diameter and 18 cm length fit most fistula tracts. The radiopaque flange provides a method of visualization during placement and creates a seal to restrict fluids from entering the tract. *When the device is placed appropriately and the seal is established to keep bowel contents out of the fistula tract, Biodesign material can be remodeled by the patient s body to assist in closing the fistula tract.

Constructed from Biodesign material, and engineered for placement, the enterocutaneous fistula plug is designed to assist the patient s body in closing the tract on its own.

Two technologies converge to create a unique treatment option. The Biodesign Enterocutaneous Fistula Plug combines Cook s proven percutaneous access technology with an advanced biologic graft technology, Biodesign. A comprehensive set The enterocutaneous fistula plug set includes the components that are necessary for a successful percutaneous placement. Biodesign Enterocutaneous Fistula Plug (4 or 7 mm in diameter and 18 cm long) Transfer tube Flexor delivery sheath (16 or 22 Fr) Dilator Pusher Molnar disk

Important considerations for patient selection If you have a patient with an enterocutaneous fistula that you would like to refer for a consultation about the Biodesign Enterocutaneous Fistula Plug, please consider these important topics for discussion with the interventional radiologist: The length and width of the tract are important. The ideal size is 2-6 mm wide and less than 18 cm long. Width sizing is crucial. If the internal opening of the fistula tract is too wide, the plug could disintegrate due to the leaking of GI fluids into the tract and could expose patients to potential risk. Some conditions can cause adverse reactions and reduce the efficacy of the plug. Examples include a distal obstruction, diverted bowel, abscess, infection, neoplasia, and radiation. If the patient has drainage, then a low output is preferred (less than 200 ml per day). The cause, duration, and location of the fistula are important. If you are interested in bringing a new procedure to your practice and learning an innovative treatment option for enterocutaneous fistula repair, please contact your local Cook representative. To learn more about Biodesign technology, visit cookbiotech.com

Reasons to choose Biodesign products An intact extracellular matrix, Biodesign material is processed in a way that preserves its natural structure and supports tissue remodeling. 5 With proper placement, Biodesign material is remodeled into strong, vascularized patient tissue and provides long-term strength without a permanent material. 3 Biodesign is a non-cross-linked biologic material, so no residual cross-linked material is left behind to cause inflammation or encapsulation. 1 Biodesign material has specific data showing efficacy across a wide variety of procedures. Biodesign material has undergone more than 18 years of improvement based on surgeon feedback and scientific research, including 6 studies with more than 5 years of follow up. Biodesign material is based on a technology that has been the subject of more than 1,269 published studies, including 437 describing use in humans and 19 randomized controlled trials. 5. Hodde J, Janis A, Ernst D. Effects of sterilization on an extracellular matrix scaffold: part I. Composition and matrix architecture. J Mater Sci Mater Med. 2007;18(4):537-543. MEDICAL COOK 08/2017 IR-D36321-EN-F