Clinical implications of the ISC technique for breast cancer radiotherapy and comparison with clinical recommendations

Similar documents
Tomohisa FURUYA*, Satoru SUGIMOTO, Chie KUROKAWA, Shuichi OZAWA, Kumiko KARASAWA and Keisuke SASAI

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

Address for Correspondence: Department of Medical Physics, Khwaja Yunus Ali University, Enayetpur, Sirajgonj ,

Potential Benefit of Scanned Proton Beam versus Photons as Adjuvant Radiation Therapy in Breast Cancer

Epworth Radiation Oncology

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

Leila E. A. Nichol Royal Surrey County Hospital

REVISITING ICRU VOLUME DEFINITIONS. Eduardo Rosenblatt Vienna, Austria

Volumetric Modulated Arc Therapy in a Large Body Habitus Patient with Left Breast Cancer: A Dosimetric Study

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

Protocol of Radiotherapy for Breast Cancer

Three dimensional conformal radiotherapy for synchronous bilateral breast irradiation using a mono iso-center technique

Radiation Damage Comparison between Intensity Modulated Radiotherapy (IMRT) and Field-in-field (FIF) Technique In Breast Cancer Treatments

Does the IMRT technique allow improvement of treatment plans (e.g. lung sparing) for lung cancer patients with small lung volume: a planning study

Radiation Planning Index for dose distribution evaluation in stereotactic radiotherapy

Variation In Mean Heart Dose By Treatment Plan Optimization During Radiotherapy For Left Sided Breast Cancer

IMRT Planning Basics AAMD Student Webinar

Commission, Ganakbari, Savar, Dhaka, Bangladesh

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

Is there a preferred IMRT technique for left-breast irradiation?

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Evaluation of three APBI techniques under NSABP B-39 guidelines

The Impact of Image Guided Radiotherapy in Breast Boost Radiotherapy

Correlation between intensity modulated radiotherapy and bone marrow suppression in breast cancer

3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast

Defining Target Volumes and Organs at Risk: a common language

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

The choice of multi beam IMRT for whole breast radiotherapy in early stage right breast cancer

Tangent field technique of TomoDirect improves dose distribution for whole-breast irradiation

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Corporate Medical Policy

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

Department of Radiotherapy & Nuclear Medicine, National Cancer Institute, Cairo University, Cairo, Egypt.

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

The dosimetric impact of intra-fraction breath hold variations during mono-isocentric left breast irradiation including nodal regions.

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction

A dosimetric evaluation of VMAT for the treatment of non-small cell lung cancer

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

Potential benefits of intensity-modulated proton therapy in head and neck cancer van de Water, Tara Arpana

Silvia Pella, PhD, DABR Brian Doozan, MS South Florida Radiation Oncology Florida Atlantic University Advanced Radiation Physics Boca Raton, Florida

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

Evaluation of Normal Tissue Complication Probability and Risk of Second Primary Cancer in Prostate Radiotherapy

Citation for published version (APA): Laan, H. P. V. D. (2010). Optimising CT guided radiotherapy for breast cancer Groningen: s.n.

162 Popescu et al.: Couch gantry arc in partial breast 162

The bootstrap method to improve statistical analysis of dosimetric data for radiotherapy outcomes

Additional Questions for Review 2D & 3D

Margins in SBRT. Mischa Hoogeman

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

A comparative dosimetric analysis of the effect of heterogeneity corrections used in three treatment planning algorithms

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

biij Initial experience in treating lung cancer with helical tomotherapy

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

COMPARISON OF THREE CONCOMITANT BOOST TECHNIQUES FOR EARLY-STAGE BREAST CANCER

Citation for published version (APA): Laan, H. P. V. D. (2010). Optimising CT guided radiotherapy for breast cancer Groningen: s.n.

Received 24 September 2015; accepted 7 November 2015; published 10 November 2015

Guang-Hua Jin 1,2, Li-Xin Chen 1*, Xiao-Wu Deng 1, Xiao-Wei Liu 2, Ying Huang 1 and Xiao-Bo Huang 1

Fuli Zhang, Weidong Xu, Huayong Jiang, Yadi Wang ( ), Junmao Gao, Qingzhi Liu

Influence of different boost techniques on radiation dose to the left anterior descending coronary artery

The Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction

Dose prescription, reporting and recording in intensity-modulated radiation therapy: a digest of the ICRU Report 83

A new homogeneity index based on statistical analysis of the dose volume histogram

A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse

Arab Journal of Nuclear Sciences and Applications

VOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER

The Physics of Oesophageal Cancer Radiotherapy

Knowledge-Based IMRT Treatment Planning for Prostate Cancer: Experience with 101. Cases from Duke Clinic. Deon Martina Dick

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Breast radiotherapy in women with pectus excavatum (funnel chest): is the lateral decubitus technique an answer? A dosimetric study

Katarzyna Pudełek, MD, PhD, Jacek Pudełek, MD, PhD, Sergiusz Nawrocki, MD, PhD, Assoc. Professor of the Medical University of Silesia

The performance of the progressive resolution optimizer (PRO) for RapidArc planning in targets with low-density media

Dosimetric Comparison: Acuros XB vs AAA

Corporate Medical Policy

Ritu Raj Upreti, S. Dayananda, R. L. Bhalawat*, Girish N. Bedre*, D. D. Deshpande

Multi-Case Knowledge-Based IMRT Treatment Planning in Head and Neck Cancer. Shelby Mariah Grzetic. Graduate Program in Medical Physics Duke University

To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Treatment of exceptionally large prostate cancer patients with low-energy intensity-modulated photons

Dosimetric comparison of preoperative single-fraction partial breast radiotherapy techniques: 3D CRT, noncoplanar IMRT, coplanar IMRT, and VMAT

Clinical experience with TomoDirect System Tangential Mode

Kenny Guida, DMP, DABR March 21 st, 2015

Chapters from Clinical Oncology

Comparative Study of 3DCRT versus IMRT in Post lumpectomy Early Stage Breast Cancer Patients

3D-CRT Breast Cancer Planning

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

NSABP PROTOCOL B-39B RTOG PROTOCOL 0413

7/28/2012. Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures***

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

Independent Dose Verification for IMRT Using Monte Carlo. C-M M Charlie Ma, Ph.D. Department of Radiation Oncology FCCC, Philadelphia, PA 19111, USA

A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation

Intensity-Modulated Radiotherapy to Bilateral Lower Limbs: A Case Study

Tangential volumetric modulated arc therapy technique for left-sided breast cancer radiotherapy

Statistical Analysis and Volumetric Dose for Organ at Risk of Prostate Cancer

Transcription:

Clinical implications of the ISC technique for breast cancer radiotherapy and comparison with clinical recommendations Anna M. Flejmer, Dan Josefsson, Mats Nilsson, Margaretha Stenmarker and Alexandru Dasu Linköping University Post Print N.B.: When citing this work, cite the original article. Original Publication: Anna M. Flejmer, Dan Josefsson, Mats Nilsson, Margaretha Stenmarker and Alexandru Dasu, Clinical implications of the ISC technique for breast cancer radiotherapy and comparison with clinical recommendations, 2014, Anticancer Research, (34), 7, 3563-3568. http://dx.doi.org/ Copyright: International Institute of Anticancer Research (IIAR) http://www.iiar-anticancer.org/ Postprint available at: Linköping University Electronic Press http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-106944

Clinical Implications of the ISC Technique for Breast Cancer Radiotherapy and Comparison with Clinical Recommendations ANNA M. FLEJMER 1, DAN JOSEFSSON 2, MATS NILSSON 3, MARGARETHA STENMARKER 3 and ALEXANDRU DASU 2 1 Department of Oncology and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden; 2 Department of Radiation Physics and Department of Medical and Health Sciences, Linköping University, Linköping, Sweden; 3 Futurum - Academy for Health and Care, County Council of Jönköping, Jönköping, Sweden Abstract. Purpose: The present project studied the implications of using the irregular surface compensator (ISC) technique in comparison to three-dimensional conformal radiation therapy (3D-CRT) for breast cancer treatment. ISC is an electronic compensation algorithm that modulates the fluence across the radiation fields to compensate for irregularly-shaped surfaces and deliver a homogeneous dose to a compensation plane. Patients and Methods: Ten breast cancer patients (five left- and five rightsided) were planned with both techniques. The planning was done for 50 Gy in 25 fractions with 2 Gy per fraction in all patients. Physical parameters such as doses to the clinical target volume (CTV-T) and the planned target volume (PTV), heterogeneity index and doses to lung and heart were determined and compared for the treatment plans. Results: The ISC technique led to significantly better coverage of the CTV-T and PTV in almost all patients with statistically significant better homogeneity of the dose distribution. The contralateral lung and the heart receive the same dose with both ISC and 3D-CRT plans. However, ISC showed a trend towards decreasing the volumes of the ipsilateral lung irradiated with high doses. Conclusion: The ISC technique leads to an improvement of the target coverage and the radiation burden of the ipsilateral lung thus allowing better compliance with the national recommendations for breast radiotherapy and increasing the potential for improved This article is freely accessible online. Correspondence to: Anna M. Flejmer, Department of Oncology, Linköping University Hospital, 581 85 Linköping, Sweden. Tel: +46 101032071, e-mail: Anna.Maria.Flejmer@lio.se Key Words: Breast radiotherapy, irregular surface compensator, fractionated radiotherapy, irradiation technique. quality of life for breast cancer patients. It should therefore be preferred over 3D-CRT for breast cases with difficult dose homogeneity to the PTV or CTV-T. Breast cancer is nowadays the most frequent cancer in women in developed countries. In Sweden alone 8,490 new cases of breast carcinomas and 1,443 cases with tumours in situ were reported in 2012 (1). Screening programs and therapeutic developments have improved prognosis and survival rates in recent years, meaning that patients could survive for many years after treatment. Radiation therapy is an important component of the arsenal of treatment modalities to achieve long-term control of local and regional disease as well as for long-term survival (2). However, side-effects from radiation may worsen the quality of life of the patients and therefore reduce the positive contribution of radiation treatment. Among the side-effects, one could include complications of the heart and the lung and also cosmetic changes in the breast and induration from the hotspots in the dose distributions. Indeed, in some instances the use of conformal radiotherapy with multi-leaf collimators (MLC), dynamic wedges and compensating fields is not enough to achieve good target uniformity and reduction of the hotspots in the target and the organs at risk. Consequently, more advanced techniques have been proposed to improve the homogeneity of dose distributions and dose hotspots in breast radiation therapy, such as electronic compensation and inverse planning intensity modulated radiation therapy (IMRT) (3, 4). Inverse planning IMRT offers most flexibility in modulating the fluence in individual beams to achieve an optimum dose distribution in the target and the surrounding normal tissues. However, it is resource-demanding and quite sensitive to interplay effects caused by motion and setup uncertainties. Electronic compensation is a comparatively simpler method of forward planning that uses dynamic MLC to modulate individual beamlets across the radiation fields in order to improve dose distributions in cases where the body contours and the target 0250-7005/2014 $2.00+.40 3563

Table I. Recommendations of the Swedish Beast Cancer Group (SweBCG) for the coverage of the clinical target volume (CTV-T) and the planned target volume (PTV) and dose burden to the organs at risk in breast cancer treatment with 50 Gy in 25 fractions. Priority Structure Recommendations 1 CTV-T V 95% =100% D mean 100% 2 PTV V 93% =100% (except for superficially located coldspots - see below) 3 Heart Recommended threshold D mean 10% (target threshold D mean 4%) Maximum heart distance, MHD, 1 cm in tangential irradiation Coronary vessels should be avoided. 4 Lung Recommended threshold D mean 20% (target threshold D mean 10%) for breast irradiation only Recommended threshold V 20 Gy 20% (target threshold V20 Gy 10%) for breast irradiation only Recommended threshold D mean 40% (target threshold Dmean 20%) for irradiation of the breast and the supraclavicular lymph nodes Recommended threshold V 20 Gy 40% (target threshold V 20 Gy 20%) for irradiation of the breast and the supraclavicular lymph nodes 5 PTV Recommended threshold V 105% 20% (target threshold V 105% 10%) In case of superficially located coldspots V 93% >90%, but these should be at the greatest possible distance from the CTV-T. volumes are rounded, such as breast treatment, and where the use of simple wedges would lead to cold- or hotspots. The irregular surface compensator (ISC) is such an electronic compensation algorithm implemented in the Eclipse treatment planning system (Varian Medical Systems). Several studies have investigated the performance of electronic compensation algorithms to improve dose homogeneity in the target (4-8), but most of them date from the period of pencil beam convolution algorithms that predict more homogeneous dose distributions in heterogeneous regions like the breast and thorax than more advanced convolution-superposition algorithms for dose calculation. Furthermore, these studies were mainly concerned with the dosimetric implications of using the mentioned algorithms. The present work proposes a new approach, namely the investigation of the clinical implications of using the ISC method from the perspective of the recommendations of the Swedish Breast Cancer Group (SweBCG) for plan acceptance (9). These recommendations are followed by a large number of Swedish radiation therapy clinics and therefore represent an interesting clinical framework for plan evaluation and acceptance in breast radiation therapy. Furthermore, dose calculations are performed with the analytical anisotropic algorithm (AAA) known to provide better accuracy for heterogeneities like those in the breast and thorax region (10, 11). Patients and Methods Ten consecutive breast cancer patients (5 left-sided and 5 rightsided), for which the routine planning with conformal radiation therapy led to high heterogeneity in the planning target volume (PTV) or hotspots outside the PTV, were included in the analysis. The patients received radiation treatment to the whole breast only (WBO) 4 patients or to the breast and the supraclavicular lymph nodes (BSC) 6 patients. The patients were CT scanned postoperatively for treatment planning with 2 mm slice thickness. The location of clinical target volume of the original tumour (CTV- T), the planning target volume (PTV) and the relevant organs at risk (lung, heart and the left anterior descending artery LAD) were delineated or approved by experienced radiation therapy oncologists. The patients were planned according to routine practice with tangential fields for WBO patients and tangential fields plus anteroposterior fields for BSC patients with a monoisocentric technique where the isocentre was placed at the junction between the breast and the supraclavicular region. For conventional conformal radiation therapy, the choice of photon energy, dynamic wedges and compensating fields for conventional planning was determined by the individual features of the patients. Corresponding plans were also created with the tangential fields devised with the ISC technique for a user-defined transmission penetration depth of 50%. All plans were calculated with the analytical anisotropic algorithm in Eclipse TPS (version 10) and normalised so that the mean dose to the PTV was equal to 50 Gy in 25 fractions. The resulting plans were evaluated in terms of dose to the PTV and the organs at risk (OAR) and compared to the recommendations of the SweBCG (Table I). Thus, PTV parameters included near minimum dose, D 98% (the dose to 98% of the PTV), near maximum dose, D 2% (dose to 2% of the PTV), the volume receiving at least 93% of the prescribed dose (V 93% ) and the heterogeneity index (HI) which was defined as: D 2% D 98% HI= (equation 1) D prescribed where D prescribed is the prescription dose. According to the recommendations of the SweBCG, the mean dose to the CTV-T and the CTV-T volume covered by at least 95% of the prescribed dose were also included in the analysis. For the OARs, clinically relevant parameters were determined from the dose volume histograms (DVH) and included mean as well as near maximum dose to the lung, the heart and the LAD. 3564

Flejmer et al: Clinical Use of ISC and Comparison Swe BCG Recommendations Table II. Mean values and the corresponding standard deviations (SD) for dosimetric parameters for the clinical with target volume (CTV-T), the planned target volume (PTV) and the organs at risk included in the analysis Conventional plan ISC plan Mean value SD Mean value SD p-value CTV-T D mean 101.1 1.6 100.8 1.4 0.5 V 95% 99.0 3.0 99.7 0.8 0.5 PTV D mean 100.0 0.0 100.0 0.0 - V 93% 97.5 2.0 98.3 1.2 0.2 V 105% 8.8 4.1 4.7 3.4 0.001 D 98% 92.5 2.5 93.3 1.0 0.2 D 2% 107.3 1.2 106.0 1.7 0.02 HI 14.8 3.4 12.6 2.3 0.02 Heart D mean 2.3 2.6 2.6 2.7 0.1 D 2% 18.4 29.7 19.6 29.9 0.3 Lung (ipsilateral) D mean 16.1 7.3 15.3 7.6 0.1 D 2% 87.5 8.6 85.9 7.8 0.1 V 20 Gy 13.8 8.1 12.8 8.3 0.07 V 10 Gy 19.4 10.4 18.3 10.6 0.1 Lung (contralateral) D mean 0.3 0.2 0.3 0.2 0.7 The dosimetric parameters in the conventional and ISC plans were evaluated for statistically significant differences with a paired, two-tailed Student s t-test. Results A summary of the dosimetric parameters for all ten patients are summarised in Table II. The ISC technique was shown to improve homogeneity of the dose distribution in the CTV- T and PTV for all the patients. Thus, the hotspots were significantly reduced in the ISC plans in comparison to the conventional plans (p=0.001 for V 105% and 0.02 for D 2% ). Similarly, the heterogeneity index was significantly smaller for ISC plans (p=0.02). Figure 1 illustrates these differences with the dose volume histograms for a representative patient. The difference in coverage of the PTV with the 93% isodose did not reach statistical significance if all the patients were pooled together (p=0.2). A subgroup analysis on leftsided patients and for BSC treatments showed an improvement of target coverage (Figure 2), but without reaching statistical significance. The trend toward improving target coverage is illustrated in Figure 3 for a left-sided BSC patient. These results are however quite promising and show that the ISC technique could improve target coverage for individual difficult cases. With respect to the normal tissues, there was no significant difference in the doses to the contralateral lung and the heart from the two techniques. There was a trend of increasing the Figure 1. Dose volume histograms for the clinical target volume (CTV) and the planning target volume (PTV) for a conventional plan (solid lines) and for the corresponding irregular surface compensator (ISC) plan (dashed lines) for one patient included in the analysis. radiation burden to the LAD and the heart with ISC, especially for left-sided patients, but this was however not statistically significant (p-values in the range 0.12-0.33). With respect to the ipsilateral lung, there was a trend of reducing the radiation burden to this organ with ISC, on the borderline of statistical significance (p=0.07 for V 20 Gy ), 3565

Figure 2. Subgroup comparisons of dosimetric parameters for the planned target volume (PTV) and the ipsilateral lung. indicating that the ISC technique has potential for lowering the dose to the ipsilateral lung, towards better compliance with the national recommendations for breast radiotherapy and also for improved quality of life of the patients after radiation therapy. Discussion Modulating individual beamlets with dynamic multileaf collimators has been proposed several years ago as an intermediate step between conventional fields with wedges and full IMRT to improve dose distributions in breast radiation therapy (4). Several studies have been published on the effectiveness of this method to improve dose homogeneity in comparison to other planning methods for breast irradiation (4-8). However, relatively little attention has been paid to the clinical implications of the potential improvement or the choice of the algorithm for dose calculation. Therefore, this study aimed to investigate the clinical implications of using ISC planning compared with conventional 3D-CRT planning from the perspective of the recommendations of the Swedish Breast Cancer Group (9), currently used for plan evaluation in Sweden. It used the analytical anisotropic algorithm that is particularly suited for dose calculation in breast radiotherapy as it better takes into account the lateral energy transport in heterogeneous media. Furthermore, the study included both WBO and BSC patients in order to investigate the clinical impact on both these subgroups of breast cancer patients, an aspect that has not been covered in previous studies. For the BSC patients it is essential to know the real dose distribution in the target and in the lungs as they involve a larger irradiated volume than patients with only the whole breast. Thus, the use of AAA for dose calculation has been associated with increased heterogeneity in the target compared to PBC calculations (12). Consequently, attempting to increase dose homogeneity 3566

Flejmer et al: Clinical Use of ISC and Comparison Swe BCG Recommendations Figure 3. Axial section showing the dose distributions from a conventional plan (left panel) and the corresponding irregular surface compensator plan (right panel) for a left-sided patient receiving treatment to the breast and the supraclavicular lymph nodes. in the target could lead to increased lung doses and hotspots that may result in higher fibrosis rates and even skin problems. Although only a few BSC patients have been included in our analysis, this population subgroup showed important trends for the irradiation of the lung, where the dose reduction with ISC was on the borderline of statistical significance (p=0.08). The results of this study showed that the ISC technique is capable of improving target coverage and reducing dose heterogeneity and hotspots for breast cancer patients. This was shown to be particularly important for BSC patients that have a larger PTV. These results complement the findings of Hideki et al (8) who also used AAA for dose calculation, but investigated only WBO patients. Improving target coverage is particularly important for patients with multifocal or lobular disease for which cold spots in the PTV should be avoided. Furthermore, decreasing the hotspots could lead to a reduction of the toxicity. From this point of view, ISC should be considered for hypofractionated schedules where hotspots could increase the biological effect much more than the percent increase in physical dose. Indeed, schedules with 2.66 Gy per fraction have been shown to lead to the same clinical outcome as schedules with fractional doses of 2 Gy (13) and might be favoured by some radiation therapy departments to decrease waiting times or increase patient throughput. Promising trends were also seen for ISC for reducing the radiation burden of the lung, also in line with the findings of other studies. This is especially important for AAA-planning as this algorithm was found to predict larger burden to this organ than PBC (12, 14). However, in two out of ten cases for which there were difficulties in fulfilling the SweBCGrecommended thresholds for lung irradiation (V 20Gy 20%) with conventional plans, the situation did not significantly improve with ISC-devised plans. Our results also indicated a trend to increase the dose to the heart and the LAD in left-sided patients, but this was not found to be statistically significant. Hideki et al (8) reported that ISC could be used to significantly reduce the dose to the heart and therefore our findings might be an artefact of the small number of patients included in the analysis. Nevertheless, further reduction of the dose to the heart could be achieved by using respiratory gating to increase the distance between the heart and the radiation beams. Modulation of the beam fluence with the dynamic MLC introduces a certain degree of complexity in the treatment of the breast that might raise a question on possible interaction with uncertainties due to respiratory motion and setup errors. However, it has been shown that the clinical implications of the dosimetric changes thus introduced are relatively small and hence clinically acceptable (15). Conclusion The ISC technique should be considered as a clinically useful alternative for breast cancer cases that require particularly high homogeneity of the dose to the target, such 3567

as patients with multifocal or lobular cancer and especially the subgroup that requires irradiation of the supraclavicular lymph nodes. It is also a useful alternative for hypofractionated treatment schedules as it could decrease the hotspots outside the target and lower the dose to organs at risk, thus having potential to improve the quality of life of the patients after radiation therapy. References 1 Socialstyrelsen: Cancerincidens i Sverige 2012. Nya diagnosticerade cancerfall år 2012. Stockholm, Socialstyrelsen, 2014 2 Darby S, McGale P, Correa C, Taylor C, Arriagada R, Clarke M, Cutter D, Davies C, Ewertz M, Godwin J, Gray R, Pierce L, Whelan T, Wang Y and Peto R: Effect of radiotherapy after breastconserving surgery on 10-year recurrence and 15-year breast cancer death: meta-analysis of individual patient data for 10801 women in 17 randomised trials. Lancet 378: 1707-1716, 2011. 3 Kestin LL, Sharpe MB, Frazier RC, Vicini FA, Yan D, Matter RC, Martinez AA and Wong JW: Intensity modulation to improve dose uniformity with tangential breast radiotherapy: initial clinical experience. Int J Radiat Oncol Biol Phys 48: 1559-1568, 2000. 4 Chui CS, Hong L, Hunt M and McCormick B: A simplified intensity modulated radiation therapy technique for the breast. Med Phys 29: 522-529, 2002. 5 James HV, Scrase CD and Poynter AJ: Practical experience with intensity-modulated radiotherapy. Br J Radiol 77: 3-14, 2004. 6 Caudell JJ, De Los Santos JF, Keene KS, Fiveash JB, Wang W, Carlisle JD and Popple R: A dosimetric comparison of electronic compensation, conventional intensity modulated radiotherapy, and tomotherapy in patients with early-stage carcinoma of the left breast. Int J Radiat Oncol Biol Phys 68: 1505-1511, 2007. 7 Emmens DJ and James HV: Irregular surface compensation for radiotherapy of the breast: correlating depth of the compensation surface with breast size and resultant dose distribution. Br J Radiol 83: 159-165, 2010. 8 Hideki F, Nao K, Hiroyuki H, Hiroshi K and Haruyuki F: Improvement of dose distribution with irregular surface compensator in whole breast radiotherapy. J Med Phys 38: 115-119, 2013. 9 Einbeigi Z, Hällje M, Johnsson S, Kjéllen L, Pålsson Y and Ärlig Å: Riktlinjer för volymer och teknik vid strålbehandling av bröstcancer. Swedish Breast Cancer Group, 2011. 10 Ulmer W, Pyyry J and Kaissl W: A 3D photon superposition/ convolution algorithm and its foundation on results of Monte Carlo calculations. Phys Med Biol 50: 1767-1790, 2005. 11 Van Esch A, Tillikainen L, Pyykkonen J, Tenhunen M, Helminen H, Siljamaki S, Alakuijala J, Paiusco M, Lori M and Huyskens DP: Testing of the analytical anisotropic algorithm for photon dose calculation. Med Phys 33: 4130-4148, 2006. 12 Yoo S, Wu Q, O'Daniel J, Horton J and Yin FF: Comparison of 3D conformal breast radiation treatment plans using the anisotropic analytical algorithm and pencil beam convolution algorithm. Radiother Oncol 103: 172-177, 2012. 13 Whelan TJ, Pignol JP, Levine MN, Julian JA, MacKenzie R, Parpia S, Shelley W, Grimard L, Bowen J, Lukka H, Perera F, Fyles A, Schneider K, Gulavita S and Freeman C: Long-term results of hypofractionated radiation therapy for breast cancer. N Engl J Med 362: 513-520, 2010. 14 Basran PS, Zavgorodni S, Berrang T, Olivotto IA and Beckham W: The impact of dose calculation algorithms on partial and whole breast radiation treatment plans. Radiat Oncol 5: 120, 2010. 15 Furuya T, Sugimoto S, Kurokawa C, Ozawa S, Karasawa K and Sasai K: The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques. J Radiat Res 54: 157-165, 2013. Received April 24, 2014 Revised May 27, 2014 Accepted May 28, 2014 3568