Relative motion sensors

Similar documents
Relative motion sensors

Technical Tip: How to Connect and Troubleshoot Transducer Feedback. Product(s): iqpump1000 and iqpump Micro Drives

LION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:

Technical Data Sheet SONOFLOW CO.55 V1.0

Technical support: +49 (0)7223 /

WNK5 Series High Precision Pressure Transmitter

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

Description. Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

INSTRUCTION MANUAL (MAN-70254)

PROFIBUS Products Overview P PROFIBUS Converter/Repeater P PROFIBUS Gateway P6-3-1

With extended functionality the sensors are also applicable for the detection of air bubbles.

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems

CANADA SENSORS TECHNOLOGY INC.

E200 ORT - Optical Rotary Torque Transducer. Contents

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

System Multiplexer / Permissive Module

Goniometer series 400

Signet 2850 Conductivity/Resistivity Sensor Electronics * *

The Do s and Don ts of Pressure Transducers

Product reference. LV switch-disconnectors 3. Product panorama 9. Functions and characteristics 17. Installation and connection 47

SPECIFICATION GUIDE. Phoenix EX AC Drive Closed Loop AC Vector Control 3 HP to 3500 HP 200 to 600 VAC Input

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA

AC CENTRIFUGAL FORWARD CURVED FAN 133 x 190

(all beam angles defined as, -3dB or half power inclusive)

RDP/DDP REDUNDANT/DUPLEX DRIVE PACKAGE

Cerus P-Series General Specifications Section 15172

Digital Dentistry Solution

Mechanical Vibration Causes, Effect, Analysis & Prevention Techniques

MicroSwitcher TMS Series 6, 10, 15, 25 Watt

Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING. Technical leaflet

TC65B, WG6. IEC Industrial Process Control Systems Guideline for evaluating process control systems. Micaela Caserza Magro Paolo Pinceti

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.

Armstrong IVS 102 Drive Specification

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES

Side Channel R ing Blower

Lexium 05 Servo Drives. Motion control The high concentrate solution for your machines

Most of the Conductivity/Resistivity electrodes used with the 2850 can be installed into standard 3 /4 in. (NPT or ISO 7-R 3 /4) fittings.

Fittings & Accessories

When worker safety is mission critical. Thermo Scientific EPD TruDose Electronic Dosimeter

Signet 2850 Conductivity/Resistivity Sensor Electronics

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

TSH Series, 2 Watt. 12 VDC 165 ma 82 % TSH 1212D ±12 VDC ±80 ma 82 % TSH 1215D ±15 VDC ±65 ma 82 % TSH 2405S 5 VDC 400 ma 78 % TSH 2412S 24 VDC ±10%

SWITCHGEAR PBD. fuse bases

SWITCHGEAR PBD. fuse bases

There are many varieties of particulate pollutants in our homes and offices. Ones from outside include industrial

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

AUTOMATIONWORX. User Manual. UM EN IBS SRE 1A Order No.: INTERBUS Register Expansion Chip IBS SRE 1A

Lexium 05 motion control

We bring quality to light. LGS 350 Goniophotometer

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.

Digital Dentistry Solution

RaySafe i3 INSTALLATION & SERVICE MANUAL

Liquid ring vacuum pumps single-stage

TABLE OF CONTENTS. 2.0 USING MANAGER PREFERENCE 2.1 Using manager preference mode 2.2 Selecting US or metric 2.3 Using CSafe

Variable Frequency Drives

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual

RLS /M MX SERIES

RiGO801 Laboratory Requirements

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage

DEVICE FOR MUSCLE COORDINATION IMPROVEMENT

Screw Compressor Pulsation & Vibration

Gyroscope. The gyroscope apparatus could easily malfunction or produce incorrect results. It should be treated with extra care.

PHYSICAL THERAPY. Combination therapy. Laser therapy. Traction therapy MAGCELL. Electrotherapy. Shockwave therapy. Cryotherapy.

LINESCAPES SYSTEM. Made in Italy

NOE LOBBY RANGE NOE LOBBY C - 1/2 hrs CMV/Collective extraction units Flow rate 400 to m 3 /h COLLECTIVE VENTILATION

PROBE CONDITIONING SYSTEM- P/N FOR BATCH FURNACES

Mini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port

Instruction Manual. DSRn. Density & Sound Velocity Transducers

RLS /M MX SERIES

CONTENTS. page 2. page 2. page 3. page 4. page 5-7. page page 12 PRECAUTIONS OPERATING INSTRUCTION EXPLODED DRAWING PARTS LIST

Evolve 3 & 5 Service Manual

5GHz Band SPDT Switch + LNA GaAs MMIC

E-Link Gateway Installation Instructions

Xstress 3000 G3/G3R. X-ray Stress Analyzer. Portable X-ray diffractometer specially designed for residual stress and retained austenite measurements

AMS 200. Goniophotometer for small to medium-sized lamps and modules

Fundamentals of Pressure Transducers

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14

Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

We bring quality to light. LGS 1000 Goniophotometer

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

RLS /E-EV MX SERIES

* * Signet 2850 Conductivity/Resistivity Sensor Electronics (PVDF) English. Description. Table of Contents. Dimensions

HOW TO USE THE SHURE MXA910 CEILING ARRAY MICROPHONE FOR VOICE LIFT

RLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL.

PHM-100 PORTABLE HANDHELD TRANSDUCER INDICATOR OPERATORS MANUAL. Transducer Techniques R

VIAVI IFR6000 DME Mode Signal Generator Reply Pulse Width Output Frequency Echo Reply Output Level Reply Pulse Rise and Fall Times (all pulses)

LED signalling luminaires / Lisu Series

MINISTAR DIGITAL AND CONTROL /// The new compact stirrers

Strain Gage Measurements

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw

Advanced Research Systems, Inc.

ATyS D10 & D20. Notice d utilisation - Operating instructions AFFICHEURS DÉPORTÉS - REMOTE INTERFACES MAKE YOUR BUSINESS SAFE

Instruction Manual January 2001 PS 10/15 F SERIESTRANSDUCER

SPG-200 SPIN BIKE OWNER S MANUAL

The comparison between the acquisition vibration data obtained by different types of transducers for hydraulic turbine head cover

Transcription:

Relative motion sensors

DISPLACEMENT TRANSDUCERS Name Operating measurement range Output signal Operating frequency range, Hz Operating temperature range, С Explosion protection level Page in catalogue IKV--- (axial shift),5-,75 mm,5-5,5 mm 5,5-9,5 mm,-9, mm IKV--- (vibration displacement peak-to-peak) IKV---. (speed of rotation, mark detection) - µm -5 µm -5 µm - µm - µm -6 RPM current loop - ma 5 (-6)-...+5 (DS-x) (-6)-...+7 vibr. AS) ExiallCT6 (DS-x) ExiallCT5 (measuring unit) 6, 8 IKV--- var. Е (multi-purpose) (axial shift, displ. pk-to-pk, rpm, mark detecting) -5 µm - µm -5 µm -8 µm,5-,75 mm,5-5,5 mm,-9, mm 5,5-9,5 mm - RPM current loop - ma; - V; Modbus RTU (HARTprotocol) -...+5 (DS-x) -...+ (vibr. AV) ExiallCT6 (DS-x) ExiallCT5 (measuring unit) In the photo: Eddy current sensors "НПП" ТИК "on pumping unit

- ESD User-friendly Design having built-in preamplifier and detachable joint allows for connection of any standard cable. Communication link length is up to 7 meters. Reliability The channel includes DS- (DS-, DS-) eddy-current probe, AS transducer (in measuring unit), or AS transducer on connecting cable. If measured parameters are required to be displayed, a display unit (DU) is provided optionally. The measuring unit can locate up to 6 display units. AS preamplifier AS Display unit Measuring unit for version V IKV--- vibration measuring channel IKV--- is designed to measure axial shift in Emergency Shut-Down (ESD) systems; Output signal type: (-) ma Specifications Metrological parameters Axial shift measurement range (distance), mm with DS- eddy-current probe (M8x).....,5-,5 with DS- eddy-current probe (Mx)....,5-,75 with DS- eddy-current probe.............,5-5,5 with DS- eddy-current probe..... 5,5-9,5(,...9,) Installation clearance (by default), mm DS- (M8x)........................,5 ±, DS- (Mx)........................,5 ±, DS-..............................., ±, DS-............................ 5,5 (5) ±, Measurement cycle time, s w/ jumper.............................,5 w/o jumper................................ Electric resistance of insulation between electrical circuits of transducer and its casing at 5±ºC and relative humidity max. 9% non-condensing (min., Mohm).... Interface Output signal................. - ma current loop Power supply voltage, V......................- (min. supply source voltage is V, +V per each 5 Ohm) Explosion protection Type....................... intrinsically safe circuit DS- (DS-, DS-) marking.............. EхiaIICT6 Measuring unit marking.................. EхiaIICT5 Connection.................... through TIK-PLC * controller through safety barrier * controller acts as ESD, power source and safety barrier Performance data Operating temperature range, С eddy-current probe.................. - +5 eddy-current probe, climatic design HL... -6 +5 transducer AS....................... -... +7 transducer AS, climatic design HL....... -6... +7 Design parameters Mounting type DS-..................... М8х threaded hole DS-.................... Мх threaded hole DS-.................... М6х threaded hole DS-.................... Мх threaded hole Dimensions (excl. cable), mm DS- eddy-current probe (M8x) D(8,5) L(5;7;9) DS- eddy-current probe (Mx) D(8,5) L(5;7;9) DS- eddy-current probe...... D(,5) L(5;7;9) DS- eddy-current probe........... D(,5) L(9) AS transducer................. 98,5x7,5x59 display unit BI.................... 5х,5х67 measuring unit for var. A, B.......... 77х7х8 measuring unit for var. V........... х8х95 Weight (excl. cable) (max., kg) DS- eddy-current probe..................,5 DS- eddy-current probe.................., DS- eddy-current probe..................,5 AS/AS transducer.................., display unit BI............................, measuring unit for var. A, B.................,5 measuring unit for var. V...................,5 Protection rating DS-х eddy-current probe.................. IP67 AS transducer........................ IP measuring unit.......................... IP66 display unit BI........................... IP Modifications IKV--- ver. А (DS-x ver.(), AS transducer, measuring unit, TIK-BIS-5-7) IKV--- ver. B (DS-x ver. with AS transducer on the cable, measuring unit, TIK-BIS-5-7) IKV--- ver. V (DS-x ver. with AS transducer on the cable, measuring unit, display unit, TIK-BIS-5-7) Reliability and manufacturer warranties Mean time between failures, hours, no less than.. Guaranteed service life, month................... 8 Lifetime, years, no less than.....................

КАНАЛ КАНАЛ КАНАЛ КАНАЛ КАНАЛ 5 КАНАЛ 6 DV-K DV-K Configurations Eddy-current probes: DS- (DS-, DS-) Type А, ver. М8х (DS-) Мх (DS-) М6х (DS-) Mx (DS-) L (5, 7, 9) AS transducer ± Measuring unit (ver. V) Male connector РМГБШЕБ Circuit +U Contact, 9, ХР Ø Cable female connector РМДКПНГВВ ХS Connecting Cable Contact ; 9 ; 5 6 7 8 L Circuit +U RESET SCK SW SW MOSI +VF Display Unit (DU) (for IKV--- ver. V) Color Brown Shield White Green +U SW SW 8 Display unit 67 Аппаратура виброизмерительная ИКВ- 85 95 ИСКРОБЕЗОПАСНЫЕ ЦЕПИ,5 упр. инф. 8 5 Channel components connection diagram Eddy-current probe mounting DS- (DS-, DS-) vibration transducer type A ver. (исп. ) Cont. Конт. Circuit, OUT, Ur ExiаIICT6 Terminal with bolt and clip vibration transducer type A ver. DS- (DS-, DS-) Hazardous area XP XS Measuring Блок измерительный unit IKV--- Transducer Преобразователь /DS AS AS XT Цепь Cont. Конт. Circuit Цепь +U SW OUT SW IN КР. (Ж) СЕР. (Б) Ur XT GND Конт. ExiаIICT5 Hazardous area Measuring unit IKV--- (-) mа BIS-- safety barrier 5 6 [Exib]IIC Intrinsically safe grounding Safe area 9 9 E R H E R H Loading range, Ohm: <(R H, R H)< Safe area BIS-- safety barrier 9 E R H DS- (DS-, DS-) Axial shift determination Axial shift measurement range DS- (M8x) (,5-,5)mm; DS- (Mx) (,5-,75)mm; DS- (,5-5,5)mm; DS- (5,5-9,5)/(,-9,)mm Machine component intended for DS- mounting DS- Shaft Installation clearance DS-(M8x)=,5 mm; DS-(Mx)=,5 mm; DS-=, mm; DS-=5,5 (5,) mm 8 mm shift,5±, mm Ж mm ExiаIICT6 Terminal with bolt and clip XP XS Cont. Circuit,9 +U, XT +U ExiаIICT5 (-) mа 5 6 Intrinsically safe grounding [Exib]IIC 9 E R H Loading range, Ohm: <(R H, R H)< mm Shaft Target surface ЦRa,8 ЦRa, Order example: IKV---; DS- type A ver. L9; 6 meter cable. 5

- ESD diagnostic Safety Breakdown and short circuit control of the cable connecting eddy-current probe with AS transducer. Reliability The channel includes DS- (DS-, DS-) eddy-current probe, the AS transducer (in measuring unit), or AS transducer on connecting cable. AS Measuring unit IKV--- vibration measuring channel is designed to measure vibration displacement peak-topeak in diagnostic and ESD systems; Output signal type: (-)ma Specifications Metrological parameters Peak-to-peak displacement measurement range, µm DS- (М8х).................... -5, -5 DS- (Мх).................... -, -5 DS-......................... -5, - DS-................................ - Installation clearance (by default, mm) DS- (М8х)........................, ±, DS- (Мх)...................... (,5) ±, DS-..............................., ±, DS-............................... 5, ±, Measurement frequency range of displacement pk-to-pk, Hz.................. -5 Electric resistance of insulation between electrical circuits of transducer and its casing at 5±ºC and relative humidity max. 9% non-condensing (min., Mohm).... Interface Output signal................. - ma current loop Power supply voltage, V..................... - (min. supply source voltage is V, +V per each 5 Ohm) Explosion protection Type....................... intrinsically safe circuit DS- (DS-, DS-) marking.............. EхiaIICT6 Measuring unit marking................. EхiaIICT5 Connection................... through safety barrier through TIK-PLC * controller *controller acts as ESD, power source and safety barrier Performance data Operating temperature range, С eddy-current probe.................. - +5 eddy-current probe, climatic design HL... -6 +5 transducer AS....................... -... +7 transducer AS, climatic design HL....... -6... +7 6 Design parameters Mounting type DS-...................... М8х threaded hole DS-..................... Мх threaded hole DS-..................... М6х threaded hole DS-..................... Мх threaded hole Dimensions (excl. cable), mm DS- eddy-current probe (M8x) D(8,5) L(5;7;9) DS- eddy-current probe (Mx) D(8,5) L(5;7;9) DS- eddy-current probe...... D(,5) L(5;7;9) DS- eddy-current probe........... D(,5) L(9) AS transducer................. 98,5х7,5х59 measuring unit.................... 77х7х8 Weight (excl. cable), max., kg DS- eddy-current probe...................,5 DS- eddy-current probe..................., DS- eddy-current probe...................,5 AS/AS transducer................., measuring unit...........................,5 Protection rating DS-х eddy-current probe................... IP67 AS transducer........................ IP measuring unit........................... IP66 Modifications IKV--- ver. А (DS-x ver.(), AS transducer, measuring unit, TIK-BIS-5-7) IKV--- ver. B (DS-x ver. with AS transducer on the cable, measuring unit, TIK-BIS-5-7) Reliability and manufacturer warranties Mean time between failures, hours, no less than.. Guaranteed service life, month................... 8 Lifetime, years, no less than.....................

Configurations Eddy-current probe: DS- (DS-, DS-) type А, ver. AS transducer M8x (DS-) Mx (DS-) M6x (DS-) Mx (DS-) (S) (grey, white),5 ХТ ХТ 59 L(5, 7, 9) L±* Terminal with bolt and clip (central core) (red, yellow) Eddy-current probe: DS- (DS-, DS-) type А, ver. Mx (DS-) M6x (DS-) Mx (DS-) Male РМДТ8КПЭШ5ВВ Circuit Contact (central core), (shield), 7,5 SW SW IN GND DS-x исп.x Uo : Io : Lo : Сo : ИКВ--- AS 98,5 г. Ui : Ii : Li : Сi : +U ХР L (5, 7, 9) Terminal with bolt and clip L±* ХТ ХТ Amplifier Cont. Cont. Cont. Cont. Cont. Cont. AS SW SW IN GND +U Connecting cable Measuring unit Connector РМД8БПЭГ Circuit Contact (central core), (shield), (S) (grey, white) ХS L Terminal with bolt and clip (central core) (red, yellow) AS transducer ø7 holes Typical installation diagram 7 Machine component intended for DS- mounting 8 mm,5±, mm ø mm DS- Target surface Ra,8 Ra, Shaft Order example: IKV---; DS- type A ver. L9; 6 meter cable. 7

Channel components connection diagram Hazardous area Safe area DS- vibration transducer type A ver. ExiаIICT6 Terminal with bolt and clip Measuring unit ExiаIICT5 AS/DS- XT XT Circuit Cont. SW SW IN GND Cont. Circuit +U (- mа) TIK-BIS-- 7 8 E R H DS- vibration transducer type A ver. ExiаIICT6 XPXS Xp Circuit Cont., OUT, Ur Terminal with bolt and clip Measuring unit AS/DS- XT XT Circuit ExiаIICT5 Cont. SW SW IN GND Cont. Circuit +U (- mа) 5 6 [Exib]IIC 9 E R H Loading range, Оhm: 5<(R H, R H)< 8

IKV--- configurations for compressors DS- Type B eddy-current probe M8x Mx 8 56,7* 7, DS- Type C eddy-current probe M8x Mx 8 5 5 7 7* DS- Type C eddy-current probe M8x Mx 8 85 6 5* DS- Type D eddy-current probe M8x Mx L* *customized for particular sizes

- ESD User-friendly Design having built-in preamplifier and detachable joint allows for connection of any standard cable. Communication link length is up to 7 meters. Reliability The channel includes DS- (DS-, DS-) eddy-current probe, AS transducer (in measuring unit), or AS transducer on connecting cable. If measured parameters are required to be displayed, a display unit (DU) is provided optionally. The measuring unit can locate up to 6 display units. Preamplifier AS AS Display unit Measuring unit for version V IKV---. vibration measuring channel IKV---. is designed to measure speed of rotation (factory mode) and to detect mark in the ESD Output signal type: (-) ma Specifications Metrological parameters Max. range of revolution speed measurement (RPM*)............................... -6 Installation clearance (by default, mm) DS-...............................,±, DS-...............................,±, DS-...............................,±, Mark detection measurement cycle time, ms...... 5 Electric resistance of insulation between electrical circuits of transducer and its casing at 5±ºC and relative humidity max. 9% non-condensing, min., Mohm... Interface Output signal................ - ma current loop Power supply voltage, V.................... - (min. supply source voltage is V. +V per each 5 Ohm) Explosion protection Type....................... intrinsically safe circuit DS- (DS-, DS-) marking............. EхiaIICT6 Measuring unit marking................. EхiaIICT5 Connection......... through TIK-PLC ** controller through safety barrier **controller acts as ESD, power source and safety barrier Performance data Operating temperature range, С eddy-current probe................ - +5 eddy-current probe, climatic design HL -6 +5 transducer AS...................... -... +7 transducer AS, climatic design HL...... -6... +7 *may be modified upon customer's request Design parameters Dimensions (excl. cable), mm DS- eddy-current probe........d(8,5) L(5;7;9) DS- eddy-current probe...... D(,5) L(5;7;9) DS- eddy-current probe........... D(,5) L(9) AS transducer................. 98,5x7,5x59 display unit....................... 5х,5х67 measuring unit, type A, Б............ 77х7х8 measuring unit, type В............. х8х95 Weight (excl. cable), max., kg DS- eddy-current probe...................,5 DS- eddy-current probe..................., DS- eddy-current probe...................,5 AS/AS transducer.................., display unit..............................., measuring unit, type A, Б...................,5 measuring unit, type В.....................,5 Protection rating DS-х eddy-current probe.................. IP67 AS transducer........................ IP measuring unit.......................... IP66 display unit............................. IP Modifications IKV---. ver. А (DS-x ver.(), AS transducer, measuring unit, through safety barrier TIK-BIS-5-7) IKV---. ver. B (DS-x ver. with AS transducer on the cable, measuring unit, through safety barrier TIK-BIS-5-7) IKV---. ver. V (DS-x ver. with AS transducer on the cable, measuring unit, display unit, through safety barrier TIK-BIS-5-7) Reliability and manufacturer warranties Mean time between failures, hours, no less than.. Guaranteed service life, month................... 8 Lifetime, years, no less than.....................

КАНАЛ КАНАЛ КАНАЛ КАНАЛ КАНАЛ 5 КАНАЛ 6 DV-K DV-K Конструктивные Configurations исполнения Eddy-current probes: DS- (DS-, DS-) Type А, ver. AS transducer Mx (DS-) M6x (DS-) Mx (DS-) Male РМДТ8КПЭШ5ВВ Circuit Contact (central core), (shield), ХР,5 ХТ ХТ L (5, 7, 9) Terminal with bolt and clip 7 59 Connecting cable Male РМДТ8КПЭШ5ВВ Circuit Contact (central core), (shield), (S) (grey, white) 7,5 SW SW IN GND DS-х исп.х Uo : Io : Lo : Сo : ИКВ---. As г. Ui : Ii : Li : Сi : +U ХS display unit (central core) (red, yellow) Measuring unit 98,5 Eddy-current probe mounting Determination of rotational speed and mark detecting DS- (DS-, DS-) Shaft 95 8 Mark ИСКРОБЕЗОПАСНЫЕ ЦЕПИ 8 Channel components connection diagram Hazardous area Safe area Installation clearance DS-=,±, mm; DS-=,±, mm; DS-=,±, mm IKV---. TIK-BIS-- DS- vibration transducer ver. ExiаIICT6 Terminal with bolt and clip AS/DS- XT Cont. Circuit SW SW IN XT Circuit Cont. GND +U ExiаIICT5 (- mа) 6 [Exib]IIC 9 E R H Loading range, Оhm: 5<(R H, R H)< Machine component intended for DS- mounting 8 mm,±, mm mm 5 mm ø mm DS- Hazardous area Safe area Mark IKV---. TIK-BIS-- DS- (var. ) ExiаIICT6 XPXS Cont.Circuit, OUT, Ur Terminal with bolt and clip AS/DS- XT XT Cont. Circuit Circuit Cont. SW SW IN +U GND ExiаIICT5 (- mа) 5 [Exib]IIC 7 8 E R H Loading range, Оhm: 5<(R H, R H)< mm Target surface ЦRa,8 ЦRa, Shaft Order example: IKV---.; DS- type A ver. L9; 6 meter cable.

- диагностика All-in-one Ability to monitor rotational speed, operate in phase marker mode, measure working surface clearance, and vibration displacement peak-to- Reliability The channel includes DS- (DS-, DS-) eddy-current probe and AS-V transducer (in measuring unit). If measured parameters are required to be displayed, a display unit (DU) is provided optionally. AV-V Measuring unit IKV--- vibration measuring channel multi-purpose E is designed to measure vibration displacement peak-topeak, rotational speed, axial shift and detect marks in the vibration monitoring systems for rotary machinery; Output signal type: (-) ma, (-) V, Modbus RTU Specifications Metrological parameters Peak-to-peak displacement measurement range, µm DS- eddy-current probe............... -5 DS- eddy-current probe............... -5 DS- eddy-current probe (,-9,)........ -8 DS- eddy-current probe (5,5-9,5)........ - Clearance measurement range, mm DS- eddy-current probe............,5-,75 DS- eddy-current probe..............,5-5,5 DS- eddy-current probe..............,-9, DS- eddy-current probe.............. 5,5-9,5 Range of revolution speed measurement (RPM)............................. - Sampling frequency of phase marker, khz..... 8,75 Measurement cycle time, msec............... 6,6 Rotational speed measurement error, %.......... over. to of max. measurement range value..... below. of max. measurement range value Clearance measurement accuracy, µm for DS-.............................. ±5 for DS-............................. ± for DS-............................. ± Pk-to-Pk measurement error, %................. 5 over, to of max........... below, of max. Installation clearance (by default), mm DS- eddy-current probe.............,5 ±, DS- eddy-current probe............., ±, DS- eddy-current probe (,-9,)..... 5, ±, DS- eddy-current probe (,-9,)..... 7,5 ±, Interface Output signal............... - ma current loop... V Modbus RTU (HART) Power supply voltage, V............... (-) Explosion protection Type...................... intrinsically safe circuit DS- (DS-, DS-) marking............. EхiaIICT6 Measuring unit marking................. EхiaIICT5 Performance data Operating temperature range, С vibration transducer................. -...+5 AV-V transducer................. -...+ Design parameters Mounting type DS-................... Мх threaded hole DS-................... М6х threaded hole DS-.................... Мх threaded hole Dimensions (excl. cable), mm DS- eddy-current probe...... D(8,5) L(5;7;9) DS- eddy-current probe..... D(,5) L(5;7;9) DS- eddy-current probe.......... D(,5) L(9) display unit..................... 5х,5х67 measuring unit................... 77х7х8 Weight (excl. cable), max., kg DS- eddy-current probe.................,5 DS- eddy-current probe................., DS- eddy-current probe.................,5 measuring unit.........................,5 Protection rating DS-х eddy-current probe................. IP67 measuring unit......................... IP66 Reliability and manufacturer warranties Mean time between failures, hours, no less than Guaranteed service life, month.................. 8 Lifetime, years, no less than....................

Approvals

Approvals

Approvals 5

*57* TIK Research & Production Enterprise, Limited Liability Company A, Marii Zagummennykh St., Perm, 667, Russia Tel./Fax+7 () -75-75, -55-5 E-mail: tik@perm.ru Web-site: http:// tik.perm.ru