The information contained in this document is intended for healthcare professionals only.

Similar documents
The information contained in this document is intended for healthcare professionals only.

MicroSeal Total Hip Acetabular System. Like Nothing Else

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

G7 ACETABULAR SYSTEM. beautifully. efficient.

Exeter. Designed for Anatomic Restoration. Clinical Evidence Education

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

Stability without compromise. Epsilon Durasul Constrained Insert

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

The Leader in Orthopaedic Innovation

PINNACLE REVISION CUP SYSTEM

LEGION Total Knee System. Exceptional Durability

Constrained Acetabular Insert

Optimum implant geometry

Optimum implant geometry

Trinity. Advanced Bearing Acetabular System Surgical technique

Longevity Offset and Oblique Liners. Surgical Technique

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

Trilogy Acetabular System

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

MARATHON Cross-Linked Polyethylene

Trilogy Acetabular System

Manza Cup HA SURGICAL TECHNIQUE.

ACETABULAR CUP SURGICAL TECHNIQUE

Versatility in a proven design. Trilogy Acetabular System

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

PyroCarbon Implants Durability + Biocompatibility

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

Understanding Hip Implant Options

UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD

OPTIONAL/ADDITIONAL INSTRUMENTS

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Restoration Anatomic Acetabular System Surgical Technique

Duraloc CONSTRAINED LINER

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

CeramTec Medical Products. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

Hip Product Brochure

Arcos Modular Femoral Revision System

Bi-Polar 22.2mm & 28mm System - Operative technique

Medical Products Division. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

FMP Surgical Technique

Optimum implant geometry

Instrumentation Options

Exeter. Technical Guide

PLR. Proximal Loading Revision Hip System

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Scan Bi-Polar 22/28. Operative Technique

Trident Ceramic Acetabular System Technical Monograph

TOTAL HIP REPLACEMENT:

Reaching new heights. Comprehensive. Efficient. Simple.

REFLECTION Constrained Liner Introduction

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

Bone Preservation Stem

Featuring. Technology. Product Rationale

System Surgical Protocol

StelKast Acetabular. Surgical Protocol and Product Specifications. Including ProForm, Provident, Provident Apical Threaded Hole & Systems

ADM X3 Mobile Bearing Hip. System Surgical Protocol. Available with X3 Advanced Bearing Technology. For Use With Restoration ADM Cups and Inserts

Trident Constrained Acetabular Insert Surgical Protocol

*smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System. Product Information

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

Dual Mobility System Surgical technique

Allofit /Allofit -S Alloclassic Acetabular Cup System

ArComXL Polyethylene: A New Way to Process Highly Crosslinked Polyethylene

D E S I G N R A T I O N A L E

Restoration Modular Revision Hip System. Choice Matters

ARTICLE IN PRESS. Surface Oxidized Zirconium Total Hip Arthroplasty Head Damage Due to Closed Reduction. Effects on Polyethylene Wear

One system for all revision types

Mako Total Hip Direct anterior approach

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

Dual Mobility System Evaluation surgical technique

MULTIPOLAR BIPOLAR CUP. Surgical Technique

Tritanium Acetabular System Surgical Protocol. Cluster Hole Shell Solid Back Shell

Designed for life. Implant technology with unmatched wear performance

PAL Pelvic Alignment Level

Surgical Technique. Cup System

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Zimmer TM. Continuum Acetabular System. Bringing together proven technologies.

A NEW APPROACH TO BEARING SURFACES FOR TOTAL HIP ARTHROPLASTY

Trabecular Metal Acetabular Revision System Buttress and Shim Augments Surgical Technique

Implants for surgery Partial and total hip joint prostheses. Part 12: Deformation test method for acetabular shells

EVOLVING OUR HERITAGE, MEETING YOUR NEEDS. Surgical Technique

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Comprehensive Reverse Shoulder System

Dr. John Masonis Charlotte, NC OrthoCarolina. Dr. James Waddell Toronto, Ontario University of Toronto, St. Michael s Hospital

This document is a preview generated by EVS

ReCap Product Rationale

CERAMIC-ON-METAL. References: Cat No: version 2

RM Philosophy Innovation based on clinical evidence.

Design Rationale. ECHELON Primary Hip System

Trident All Poly Acetabular System

Aesculap Plasmafit. Cementless Acetabular Cup System. Aesculap Orthopaedics

DURALOC. Acetabular Cup System. Surgical Technique

R3think your options. For US distribution only.

Sulzer Orthopedics Joint & Fracture Care

Trident. Acetabular System Hemispherical Surgical Protocol

39 year old, 260 lb. park ranger. TKA in situ: 4 Years. First reported Metal-backed, non-modular PCA knee. 16% incidence. Modular metalbacked

Peggers Super Summaries: THR and Revision Concepts

FLH /11

Transcription:

The information contained in this document is intended for healthcare professionals only.

Trident Poly Acetabular System Trident PSL HA Acetabular Shell with X3 Poly insert Trident Hemispherical Acetabular Shell With New X3 Polyethylene

Trident Poly Acetabular System The Trident Acetabular System has been implanted throughout the world since 1999 and, while commercially available, has also been included in a clinical evaluation through an IDE study in the United States. All Trident Acetabular Shells feature the Innerchange Locking Mechanism, which provides independent locking of polyethylene or ceramic inserts into the shell. The Trident Acetabular System offers: Superior locking mechanisms for both polyethylene and ceramic inserts (1) X3 polyethylene for improved wear performance (A) Choice of shell geometries Arc-deposited roughened surface to help achieve immediate stability Purefix HA Eccentric and Constrained Inserts for revision options Trident PSL HA Acetabular Shell The Trident PSL Acetabular Shells are designed to maximize fixation in the peripheral lunate region of the acetabulum. Purefix HA coating is featured on all Trident PSL shells. Trident Hemispherical Acetabular Shell Trident Hemispherical Acetabular Shells are a true hemispherical shape designed to achieve press-fit fixation by under-reaming the acetabulum. 2

Innerchange Locking Mechanism BARB/SCALLOP ENGAGEMENT The Patented Innerchange Locking Mechanism allows for independent locking of polyethylene and ceramic inserts into the shell. This provides radial and tilting micromotion resistance. (1) The Trident polyethylene insert allows for proper rotational alignment using 12 indexable scallops. Polyethylene inserts lock into the shell in three ways: Four alignment studs on the shell provide proper rotational and axial alignment Unique bead and groove mechanism Additional rim locking provides for exceptional insert stability Innerchange Locking Mechanism POLYETHYLENE PRESS-FIT AT RIM CONGRUENT DESIGN POLYETHYLENE BEAD/SHELL GROOVE Extensively Tested Locking Mechanism Fully congruent design Independent testing by Alan Litsky, MD, PhD at Ohio State University 1 Robust push-out and lever-out resistance 2 Hip simulation testing with X3 polyethylene has demonstrated improved 3, (A) wear performance According to Dr. Litsky s study, among the designs from other manufacturers, none is better than the Stryker Trident design in either radial or tilting micromotion. 1 Micromotion (µm) Radial Tilting Stryker Trident Biomet Ringloc S&N Reflection J&J PFC Zimmer Trilogy DePuy Duraloc 3

Polyethylene Polyethylene Trident polyethylene inserts are: Fully congruent to the shell Supported by extensive research on range of motion and head stability 8 Available in neutral, 10, elevated rim, eccentric and constrained designs Shell fully supports the Trident insert Neutral, 10 and Elevated Rim polyethylene options Trident X3 10 Insert Trident X3 0 Insert Trident X3 Elevated Rim Insert 4

X3 Highly Crosslinked Polyethylene X3 Highly Crosslinked polyethylene has demonstrated significant wear reduction compared to standard polyethylene. (A) Stryker s technology and conservative process have allowed increased crosslinking while maintaining the material properties of the polyethylene. (B) Material Properties Gamma/Inert UHMWPE X3 Hylamer WIAM 97% reduction in wear 3 X3 polyethylene demonstrates 97% reduction in wear over nitrogen sterilized polyethylene in joint simulation testing, thereby reducing the potential for osteolysis. (A) Material properties are retained The material properties of X3 polyethylene are similar to those of standard polyethylene, as shown in Figure 1. (B) Preserves the polymer structure of UHMWPE The crystalline and amorphous regions of X3 are similar to standard polyethylene (C) (Figure 2). Figure 1 X3 polyethylene maintains similar yield strength, modulus and crystallinity as standard polyethylene. When these properties change significantly, the clinical wear performance cannot be predicted. X3 Polyethylene Standard UHMWPE X3 Figure 2 X3 exhibits a morphology that is very similar to that of standard UHMWPE 5

LFIT Technology Improved Wear Performance with LFIT Femoral Head Technology Low Friction Ion Treatment (LFIT ) is a bombardment of nitrogen ions onto a CoCr surface, which enhances material properties of the metal, in turn reducing frictional forces against UHMWPE surfaces. LFIT : Improves wettability Reduces coefficient of friction 7 Wettable materials are important in total hip arthroplasty LFIT In an anatomic hip joint, the femoral head is cushioned by cartilage, which seeps lubrication into the joint. When the joint is diseased or removed, the natural lubrication surface is also removed, and the femoral head and acetabular insert contact each other. LFIT femoral heads are designed to increase lubrication. Clinical Experience with LFIT The LFIT heads demonstrated a 28% reduction in linear wear over CoCr heads in 110 patients at minimum 3-year follow up 9 (Figure 3). This data coincides with hip simulation testing. 6 These results are encouraging Nitrogen ion implanted femoral heads may be an effective way to decrease UHMWPE wear and increase implant longevity in THA. 7 CoCr CoCr LFIT Wettable materials have a lower boundary angle between a liquid and a solid. UHMWPE Linear Wear Figure 3 LFIT heads demonstrated a 28% reduction in linear wear over CoCr heads 6

Revision Options A Trident Hemispherical Multi-Hole Acetabular Shell with Purefix HA is available providing increased screw hole options (Figure 4). Eccentric and Constrained Inserts augment the Trident System with revision options to increase surgeon flexibility in complex primary or revision surgery. The Trident Eccentric Inserts feature X3 Highly Crosslinked Polyethylene for improved wear performance. 3, (A) The head center is lateralized 6mm from the center of the acetabular shell allowing increased polyethylene thickness and joint stability (Figure 5). Trident Constrained Inserts are available for total hip patients who exhibit a risk of hip dislocation. Constrained Inserts feature pre-assembled inserts with the unique Stryker design UHR bipolar (Figure 6). Figure 4 Trident Hemispherical Multi-Hole Acetabular Shell Cross-section of Trident Eccentric Insert Cross-section of Trident Constrained Insert CENTER OF SHELL CENTER OF ECCENTRIC INSERT 6mm SAME HEAD CENTER AS STANDARD POLY INSERT Figure 5 Figure 6 0 Eccentric Insert Constrained Insert Revision Options 10 Hooded Eccentric Insert 7

Trident Poly Acetabular System Compatibility Trident polyethylene inserts may be used with V40 or C-taper femoral heads. The alphabetical letter at the end of all Trident catalog numbers identifies compatibility among all Trident acetabular components. Matching the shell and insert Alpha Codes will ensure proper compatibility. Trident Compatibility Chart Trident Trident X3 N 2 /Vac Alpha PSL HA Hemispherical 0 and 10 0 and 10 Code Shell Size (mm) Shell Size (mm) Inserts (mm) Inserts (mm) A 40 42 22 N/A B 42 44 22 N/A C 44 46 22, 26, 28 N/A D 46, 48 48, 50 22, 26, 28, 32 28 E 50, 52 52, 54 22, 26, 28, 32, 36 28 F 54, 56 56, 58 22, 26, 28, 32, 36 28 G 58, 60 60, 62 22, 26, 28, 32, 36 28 H 62, 64 64, 66 22, 26, 28, 32, 36 28 I 66, 68 68, 70 22, 26, 28, 32, 36 28 J 70, 72 72, 74 22, 26, 28, 32, 36 28 N/A=not available (A) Stryker Orthopaedics Trident Acetabular Inserts made of X3 UHMWPE, 721-00-32E, show a 97% reduction in volumetric wear rate versus the same insert fabricated from N2Vac gamma sterilized UHMWPE, 620-00-32E. The insert tested was 7.5 mm thick with an inner diameter of 32 mm. Testing was conducted under multi-axial hip joint simulation for 5 million cycles using a 32mm CoCr articulating counterface and calf serum lubricant. X3 UHMWPE Trident acetabular inserts showed a net weight gain due to fluid absorption phenomena but yielded a positive slope and wear rate in linear regression analysis. Volumetric wear rates were 46.39 ± 11.42 mm3/106 cycles for standard polyethylene inserts and 1.35 ± 0.68 mm3/106 cycles for test samples. Testing was performed on un-sterilized X3 UHMWPE Trident acetabular inserts. Although in-vitro hip wear simulation methods have not been shown to quantitatively predict clinical wear performance, the current model has been able to reproduce correct wear resistance rankings for some materials with documented clinical results. [1-3] (B) X3 UHMWPE meets ASTM F648 for Density as measured per ASTM D1505. X3 UHMWPE exceeds ASTM F648 requirements for Tensile Yield Strength, Ultimate Tensile Strength, Elongation and Impact Strength for a Type 3 resin (Tensile strengths and elongation measured per ASTM D638, impact strength per F648, Annex A1). (C) X3 UHMWPE has similar crystalline and lamellar structure as N2Vac gamma sterilized UHMWPE as measured by Small Angle X-ray Scattering (SAXS) and Differential Scanning Calorimetry (DSC) analysis. DSC determined crystallinity was 61.3 ± 0.8% and 61.7 ± 0.6% for N2Vac UHMWPE and X3 UHMWPE, respectively. Lamellar crystal thickness was 23.0 and 23.6 nanometers for N2Vac UHMWPE and X3 UHMWPE, respectively. (D)Stryker Orthopaedics Trident Acetabular Inserts made of X3 UHMWPE shows similar wear particle shape and size as Stryker Orthopaedics Trident Acetabular Inserts made of N2Vac gamma sterilized UHMWPE. Un-sterilized Trident X3 UHMWPE acetabular insert wear debris showed a length of 0.471 ± 0.814 microns, a width of 0.247 ± 0.399 microns and an aspect ration of 1.99 ± 1.76, while N2Vac UHMWPE polyethylene Trident acetabular insert wear debris showed a length of 0.409 ± 0.553 microns, a width of 0.221 ± 0.356 microns and an aspect ratio of 2.34 ± 3.48. Wear debris was generated from multi-axial hip simulation testing and was isolated following published techniques. [4] [1] Wang, A. et. al., Tribology International, Vol. 31, No. 1-3 : 17-33, 1998. [2] Essner. A. et. al., 44th Annual Meeting, ORS, New Orleans, Mar. 16-19, 1998: 774. [3] Essner, A. et. al., 47th Annual Meeting, ORS, San Francisco, Feb. 25-28, 2001: 1007. [3] Essner. A. et. al., 47th Annual Meeting, ORS, San Francisco, Feb. 25-28, 2001: 1007. [4] Scott, M. et. al., Transactions of the 6th World Biomaterials Congress (SFB), Minneapolis, 2000: 177. References 1 Litsky, AS, et al, Micromotion Between the cup and the Liner in Modular Acetabular Prostheses, 1999 Society for Biomaterials, 25th Annual Meeting Transactions. 2 RD-98-0101. 3 RD-03-082. 4 Jasty, M, et al, Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty, JBJS, 70A, March 1997. 5 Dumbleton, JH, Edidin, AA, A Highly Crosslinked Oxidation-Resistant Polyethylene: X3, Stryker Literature #LSA29. 6 Taylor, S, Reduction in Polyethylene Wear through Ion-Implantation into CoCr Alloy, Surface Modification Technologies VI, The Minerals, Metals & Materials Society, 1993. 7 Maruyama, M, et al, Effect of Low Friction Ion Treated Femoral Heads on Polyethylene Wear Rates, CORR, Number 370, pp. 183-191. 8 Dong, et al, Hip Joint Stability Determined by Acetabular Bearing Insert Design, An in-vitro Simulated Study, ORS, 1999. US Patent 6,475,243 The information presented in this brochure is intended to demonstrate the breadth of Stryker product offerings. Always refer to the package insert, product label and/or user instructions before using any Stryker product. Products may not be available in all markets. Product availability is subject to the regulatory or medical practices that govern individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. The marks bearing the symbol TM are trademarks of Stryker. The marks bearing the symbol are registered trademarks of Stryker. Literature Number: LX3SB GC/GS 3.0m 04/05 Copyright 2005 Stryker Printed in USA 325 Corporate Drive Mahwah, NJ 07430 t: 201 831 5000 www.stryker.com