Managing echocardiography workflow

Similar documents
Echocardiography A powerful module of MediConnect

How-To Evaluate a Veterinary Digital Radiography System A SPECIAL REPORT

Complex just became comfortable.

GE Healthcare 9900 Innovation Drive Wauwatosa, WI U.S.A.

History of SETMA s Preparation for ICD-10 By James L. Holly, MD October 1, 2015

Case Studies. Any other questions? medicom.us

A World without Boundaries. with Smart Portable Ultrasound

High performance compact ultrasound

THE PACS/IT CONTINUUM: PRESENT ACCESS AND FUTURE INTEGRATION STRATEGIES, Table of Contents

High performance compact ultrasound

Hologic Digital Technology Forms Cornerstone For Growing Women s Health Center

Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive

Sonography Program Application and Information Packet. Lackawanna College Sonography Programs Technical Standards

How Doctors Feel About Electronic Health Records. National Physician Poll by The Harris Poll

USERS GROUP AGENDA 2014

402 Intro to Clinical Thinking, Winter 2010 Final Group Presentation, Group 1

CHAPTER 6 DESIGN AND ARCHITECTURE OF REAL TIME WEB-CENTRIC TELEHEALTH DIABETES DIAGNOSIS EXPERT SYSTEM

Pioneering Radiology Revenues: The NovaPRO Business Growth Model

vertaplan the spine surgeon s software vertaplan System for successful reconstruction of the individual sagittal balance

Digital mammography imaging from Carestream Health solutions for great workflow, productivity, and patient care.

Telemedicine and the Native American Cardiology Program

Interpretype Video Remote Interpreting (VRI) Subscription Service White Paper September 2010

Premium performance compact ultrasound. Philips CX50 POC CompactXtreme ultrasound system

Changing your idea of clinical performance. Philips HD15 PureWave ultrasound system for echocardiography

INTRODUCTION TO DICOM FOR THE PRACTICING VETERINARIAN

A new way of thinking. Philips Sparq emergency medicine ultrasound system

Lunar Prodigy Advance

High performance ultrasound

PUT THE POWER AND PRODUCTIVITY OF DENTRIX IN YOUR PRACTICE

Results from a survey of NetAssess users Alan Mead Aon Consulting.

E-Prescribing, EPCS & PDMP: An Update

EHR Developer Code of Conduct Frequently Asked Questions

Cortex Gateway 2.0. Administrator Guide. September Document Version C

Surveillance of Recent HIV Infections: Using a Pointof-Care Recency Test to Rapidly Detect and Respond to Recent Infections

Smart NDT Tools: A New Generation of NDT Devices

This report summarizes the stakeholder feedback that was received through the online survey.

myaudiometer. It s familiar, and it s so much

Gaps In Successful EHR Implementations: The Challenges & Successes Of Providers In The Marketplace

2018 INFUSE CALL FOR INNOVATION

A new class of compact ultrasound. Philips CX50 CompactXtreme ultrasound system

powerful versatile mobile

THE FIRST SESSION CHECKLIST

New York State Immunization Information System (NYSIIS) New York State Department of Health. Digital Government: Government to Business (G to B)

Content Part 2 Users manual... 4

university client training program

Premium performance compact ultrasound. Philips CX50 CompactXtreme ultrasound system

Keywords Web-Based Remote Training Program, Thai Speech Therapy, Articulation Disorders.

ASCO Power Control Systems Overview

TRAINING COORDINATOR TRAINING

Electronic Test Orders and Results (ETOR)

Premium performance compact ultrasound. Philips CX50 CompactXtreme ultrasound system

Report on. The feasibility of including blood lead level assessment information in the school records of enrolled children

Implementing a Modern NDT Inspection Program Utilizing Connected Instruments and Cloud Software Solutions

Premium performance compact ultrasound. Philips CX50 CompactXtreme ultrasound system

Implementing Convertible, Flexible and Scaleable Ultrasound

Dictation of Outside Imaging studies. Part1: For EMS and Trauma Service Patients in the ED

SIS Customer Satisfaction Survey - Key Learnings

Instructor Guide to EHR Go

Premium performance compact ultrasound

InTouch Center Local Customer Teams InTouch Agreements Parts Support

Versana Premier. Care with Confidence. gehealthcare.com

Abstract. Introduction. Providers stand to lose $1.15 billion in CMS reimbursements under MU

HIV Care & Treatment Program STATE OF OREGON

Premium performance compact ultrasound. Philips CX50 POC CompactXtreme ultrasound system

When You Need To Know More.

2015 Exam Committees Report for the National Physical Therapy Examination Program

Client Satisfaction Survey

INSERT COMPANY LOGO HERE

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Interactive Mobile Health and Rehabilitation

A Quality Improvement Project: Decreasing the Time from Diagnosis to Surgery in Patients with Bladder Cancer

IntelliSpace Breast. Mammography solutions. Manage your breast review environment

GE Healthcare. Vivid i Cardiovascular ultrasound system

The American College of Radiology Breast Ultrasound Accreditation Program: Frequently Asked Questions (Revised: July 31, 2017)

Not all NLP is Created Equal:

A Closer Look at Radiology s Role in Corporate Healthcare. Mark D. Jensen, CEO, Charlotte Radiology

Welch Allyn HScribe Holter Analysis System

2017/8/23 1. SE-2003&SE-2012 Holter Analysis System

Vascular. HealthView. Cardiovascular Data Intelligence.

Radiation Oncology. The conf ident path to treatment Philips Radiation Oncology Solutions

Harvard Pilgrim Spine Management Provider Training

The Value of Walgreens

Free ecosystem for medical imaging

Eliminate the Most Common Challenges in Audiometric Testing A Case for Tablet Audiometry in Occupational Hearing Conservation

Timothy M. Gustafson, MBA, R.T. (R)

A World without Boundaries. with Smart Portable Ultrasound

Continuing the momentum to deliver improved performance. Robert Cascella Chief Business Leader Diagnosis & Treatment

Kent Joint Commissioning Action Plan For Adults with Autism and or ADHD (2017 / 2021)

The Joint Commission: Comprehensive Overview of Advanced Stroke & Advance Heart Failure Programs

Potential Cancer Registrar

SIM HIT Assessment. Table 1: Practice Capacity to Support Data Elements

STATE OPERATIONS MANUAL

Lowering epilepsy-related treatment costs in the era of patient choice and value-based care


Open Range Software, LLC

Roger TM at work. Focus on work rather than on hearing

RESULTS REPORTING MANUAL. Hospital Births Newborn Screening Program June 2016

Distribution Partner Briefing: A Partnership for Profit. Welcome to Smartcool s information package for prospective channel partners.

Mahoning County Public Health. Epidemiology Response Annex

Imaging Performance Partnership. A Data Driven Approach to Your Imaging Program Strategy

Transcription:

Clinical applications Managing echocardiography workflow A. Keller R. Rigling J. Rock Chief of Cardiology and Director, Echocardiography Center, Regional Heart and Vascular Center, Danbury Hospital, Danbury CT, USA. Clinical Manager, Echocardiography Center, Regional Heart and Vascular Center, Danbury Hospital, Danbury CT, USA. Director, Clinical Science & Applications, Cardiology Informatics, Philips Medical Systems, Andover MA, USA. In February 2005,The Regional Heart and Vascular Center at Danbury Hospital went live with Philips Xcelera Echo Lab Management, an echo reporting and management system that it had beta-tested for Philips. The system helped the center implement a new workflow that reduces the timeto-report, enhancing sonographers knowledge, satisfying both readers and referring physicians, and enhancing patient care. Located in Danbury, Connecticut, the Regional Heart and Vascular Center at Danbury Hospital (Figure 1) serves Western Connecticut and Eastern New York. Danbury Hospital s Echocardiography Laboratory is the first lab in Fairfield County (and one of the first 50 labs in the world) to be accredited by the Intersocietal Commission for the Accreditation of Echocardiography Laboratories. The lab is accredited in all three major areas of echocardiography, i.e. Transthoracic Echo, Transesophageal Echo, and Stress Echocardiography. At the main campus, plus two outpatient centers, the staff conducts over 9,000 studies each year, including 2,000 stress echos, 6,500 Adult TTEs, 300 pediatric TTEs, 250 adult TEEs, and 500 interoperative TEEs. The staff includes six physicians, seven sonographers, a clinical manager, an RN, and clerical support. In 1999, workflow in the Echocardiography Center was not optimized. Study acquisition (Figure 2) is only one of many steps. In fact, an analysis of the workflow (See Intermezzo, page 35) identified 26 steps to efficiently and effectively running an echo lab. All of these steps could, in principle, be managed using appropriate software. At that time, however, there was no suitable commercially available software or hardware. Nevertheless, using the MESA test tools from the IHE, the laboratory was able to implement a digital display and storage system. The software was run on a Linux-based system, with 1 G Figure 1. Danbury hospital. 2 F Figure 2. Conducting an exam in the Echocardiography Center. MEDICAMUNDI 51/1 2007/06 31

E Figure 3. Evaluating results at an Xcelera Client Workstation. 3 E The transition to digital echocardiography went smoothly and the impact was immediate. an old server that the hospital had planned to discard. While the system was a successful stop-gap solution, it lacked both support and the important workflow-enhancers that we needed. So, in 2001, it was decided to investigate commercial solutions. A team comprising the Chief of Cardiology Andrew Keller, Clinical Manager Rick Rigling, the department administrator, and representatives from purchasing and information technology visited echo labs across the country to view full service digital reporting solutions in action. Xcelera Echo Lab Management The transition to digital echocardiography went smoothly, and the impact was immediate. The system was easy to learn, supporting Philips claim to offer Sense and Simplicity. The manufacturers took care to match the way that a sonographer and a physician interact to come to the same report. A sonographer and a physician tend to look at the anatomy of the heart in different ways, but Xcelera accommodates the workflow and thought processes of both users. According to the manufacturer, Xcelera Echo Lab Management is customizable, fluid, open and standards-based, and future-safe. A brief investigation of these claims in practice led to the following conclusions: E Xcelera Echo Lab Management eases workflow and provides tools to enhance diagnosis. 32 MEDICAMUNDI 51/1 2007/06 Danbury has a long-standing relationship with Philips and had always been pleased with Philips service and responsiveness. In 2001, the Xcelera Echo Lab Management system had not yet been launched as a commercial product, but was regarded as work in progress. Nevertheless, it was closer than any commercially available product designed to meet the needs of the laboratory. The fact that Philips also provided the clinical ultrasound systems gave a measure of confidence. Xcelera Echo Lab Management eases workflow while providing tools to enhance diagnosis all from a single point of contact: the Xcelera Client Workstation (Figure 3). Seven Xcelera client workstations were obtained: three for sonographers, two for the physicians, one for the clerical support, and one for the OR. Customizable The reporting codes can be customized to make them physician-specific. This is an important aspect, as different physicians have different reporting styles, and it is easier to adapt the system to the physician rather than vice versa. Fluid The reports are available throughout the health system or online, wherever they are needed. Any secured client of the health system can immediately access the report through an interface to the hospital information system. Open and standards-based Danbury Hospital s Echocardiography Laboratory is a large laboratory that also has an active cardiology fellowship program. This means that it is important to have ultrasound

systems from several different vendors in the lab, so that the sonographers can gain experience with equipment from different manufacturers. Because the Xcelera system is open and standards-based it works with all the ultrasound systems in the lab. 4 F Figure 4. The automatically generated report. Future-safe Particularly in the case of IT, it is important to work with a large vendor, in order to be sure of getting the essential long-term support. Faster reporting One dramatic improvement that Xcelera brought to Danbury was to eliminate delays in report distribution. In the previous workflow arrangement, the study had to be read by the physician, and then transcribed and proofed to create the final report, which had to be available within 24 business hours. Given the conditions, this turn-around time was regarded as acceptable, but the time saved with Xcelera is remarkable. Once the sonographer finishes the study, it is on the chart in the patient s room in 5-10 minutes. For outpatients, the referring physician can find the results on the HIS within the same timeframe. Using Xcelera, the report is completed within five minutes of the interpretation of the study and is electronically signed and disseminated (Figure 4). Before implementation of Xcelera, digital images were stored on a server and viewed with a digital viewer. Reporting was done using different software, and paper copies were sent to the referring physicians. The readers would sit at PCs and dictate diagnoses as they viewed the studies. They had a paper on which they circled codes. The transcriptionist could enter those code numbers, which would then generate phrases. However, these were not automatically transferred to the final report. Instead, the full interpretation had to be dictated, transcribed, proofed, signed and distributed. The problems were not confined to the number of steps. The physical location was also challenging. The images had to be viewed on the imaging system, while the reports had to be read at the other side of the room on a different PC. The transition to Xcelera required changes from the entire staff. There were concerns that the readers might not accept the user interface, and that referring physicians might not like the automated language of the reports. These concerns proved to be unfounded. All the readers were enthusiastic, and the faster report generation resulted in higher referring physician satisfaction. People were calling out of nowhere to say how fantastic it was to get a report shortly after the study. The fact that the reports looked different was not regarded as a problem. The important thing was that the referring physician got the report quickly, often before the patient returned from the exam. In echo, and particularly in echocardiography, physicians want to know the results quickly so they can make a judgment to start treatment if necessary. In the past, referring physicians were always called immediately if there were markedly abnormal reports. But distributing reports quickly on normal or near-normal studies is also helpful. A report of a mild or moderate abnormality, transmitted to the treating physician in a timely fashion, facilitates treatment of that patient. Timeliness is also valuable with normal reports, because it diffuses patient anxiety. An additional benefit is that Xcelera sigificantly reduces the amount of paperwork the patient has to carry around. The faster turn-around time has given Danbury a competitive edge. The hospital s volume has grown, due at least in part to the enhanced efficiency of the Echocardiography Center and the satisfaction of referring physicians. Greater role for sonographers With Xcelera, the sonographers roles have expanded beyond image acquisition. After acquiring studies, they immediately fill out the report, adding the demographics and preliminary results. The report then goes to the E One dramatic improvement was to eliminate delays in report distribution. E Using Xcelera, the report is distributed within five minutes. MEDICAMUNDI 51/1 2007/06 33

E The ideal would be a paperless environment until the final report is generated. physician, who makes any necessary changes. This change in workflow, requiring the sonographer to commit to the preliminary report, has proven to be educational for the sonographers. The number of patient recalls has also decreased. This may be due, at least in part, to the additional understanding of clinical pathology the sonographers have gained from using Xcelera. Studies are now reviewed on the spot, in the presence of the sonographer, rather than simply passed on to physicians and reviewed later. The goal is to have other sonographers reports match the physicians reports, in order to increase efficiency. The transcriptionists roles have also changed, from rephrasing and adapting reports to focusing on proofreading and distributing. The future The current Xcelera solution is regarded as the first step in an overall plan to enhance workflow. In the short term, Xcelera will be augmented with multi-modality viewing and web access. The current interface with the HIS will also be modified, so that the demographics in the report can be automatically populated. A new outpatient center is currently being built, which will contain additional Xcelera workstations. The other satellite clinics will also be equipped with reporting capabilities, rather than housing only the echo systems and sending images to the main campus for reporting. Beyond these short-term goals, the aim is to create an automated workflow that reduces the cost of the laborious manual entry that is now done on a daily basis. The information should flow automatically from the HIS and order entry system to the ultrasound department and from there to billing and accounts receivable. It should also be possible to audit the sonographers and physicians time on a quarterly basis. A further development will be to interface with an image broker such as Philips isite, so that images can be displayed across the infrastructure of the hospital and at physicians homes. The last of the 26 steps would be an automated customer satisfaction survey. Conclusion Xcelera has lived up to the expectations. The next phase is to expand what Xcelera can achieve. It has already been possible to significantly decrease the paper that travels with a patient who has a test done, but the ideal would be to go to a paperless environment until the final report is generated K INTERMEZZO Workflow analysis showing the 26 steps of efficiently and effectively running an echo lab 34 MEDICAMUNDI 51/1 2007/06 Danbury Hospital Echocardiography Laboratory Office of the Director Danbury, CT 06810 Memorandum Subject: Ideal laboratory workflow paradigm Developing a plan to streamline HIS order processing, digital echocardiographic acquisition and storage, reporting, billing, remote reviewing, and validation. Audience: Partners in a Luminary Agreement. Abstract: Acquiring echocardiographic studies forms just a small part of the body of work performed in a busy echocardiographic laboratory. Busy, efficient imaging laboratories in Cardiology must incorporate workflow processes to remain competitive and efficient. Key components of successful workflow (from start to finish) include:

1. Order entry, processing, and receipt 2. Pre-authorization 3. Scheduling with the patient and staff static review of existing health care providers 4. Transportation 5. Registration and payer verification 6. Reconciliation of patient demographics (for name or demographic changes) 7. Coordination with physicians performing the examination 8. Workflow document processing (hardcopy of order, billing information, previous reports and media) 9. Pre-fetch clinical history and payer information, including Advanced Beneficiary Notice 10. Study acquisition 11. Notification of study status changes 12. Study archiving and storage 13. Study retrieval using an intelligent rapid search 14. Study dissemination in a diagnostic consistent format for review 15. Study dissemination over broad band Internet pipes 16. Study dissemination as a thumbnail for bedside review without interpretation 17. Preliminary reporting 18. Professional review 19. Quality assurance 20. Transcription and reporting, review and electronic signature 21. Report dissemination, including images, and transmission to HIS and LCR. 22. Access to aggregate numerical values or discrete entities for statistical analysis 23. Billing and auditing based on body of work performed (triggered by reporting) 24. Validation of storage/reporting 25. Laboratory statistics 26. Patient satisfaction survey Entities that can restructure their laboratory to automate these components will reduce cost and improve efficiency, while maintaining or improving quality and patient satisfaction. Industry entities, which develop open products to automate this workflow, will develop a marketable system with true value to the customer. Proposal: Partner with industry in a luminary environment to deploy, modify, or develop systems to develop and automate the workflow process Work Site: Danbury Hospital Danbury Hospital is conveniently located between New York and Boston, accessible by rail, air, or bus. The hospital catchment area includes over 350,000 patients in Fairfield and Litchfield counties in Connecticut, and Westchester and Duchess counties in New York State. The echo-cardiography laboratory is modern and has been accredited by ICAEL in all three adult echo-cardiographic disciplines. The patient volume is equally divided between outpatients and inpatients; the volume of the echocardiography laboratory approaches 7000 procedures per year. A geographically separate satellite office (performing 1500 studies annually) is ideal for testing connectivity issues for tele-echocardiology. The medical director of the laboratory (Dr. Andrew Keller) is a Trustee of the American Society of Echocardiography, a member of the newly formed Digital Echocardiography task force of the American Society of Echocardiography, and is recognized nationally and locally as an expert in echocardiography and data management. Mr. Richard Rigling is the technical director of the echocardiography laboratory; he is a trustee of ICAEL, and an active committee member within the American Society of Echocardiography. The facilities are large enough to accommodate and test critical test bed applications, yet small and friendly enough to allow for constant feedback with staff and physicians. The site is ideal for beta site deployment and visitation by potential customers. A strong infrastructure exists within HIS, the department of medicine (including the internal medicine training program), and human resources. MEDICAMUNDI 51/1 2007/06 35