Journal of Orthopaedic Surgery and Research 2010, 5:62

Similar documents
Case Report Late Occurring Medial Migration of a Lag Screw in Gamma Nailing

Comparitive Study between Proximal Femoral Nailing and Dynamic Hip Screw in Intertrochanteric Fracture of Femur *

Technique Guide. DHS Blade. For osteoporotic bone.

Assessment of Prognosis of Patients with Intertrochanteric Fractures Undergoing Treatment with PFN: An Observational Study

9/24/2015. When Can I Use a SHS? When CAN T I Use a SHS? Sliding Hip Screw. Time proven. Technically simple. Cheap. Quick

Randomized comparative study to evaluate the role of proximal femoral nail and dynamic hip screw in unstable trochanteric fractures

GAMMA LOCKING NAIL INSTRUMENTS OPERATIVE TECHNIQUE

Use Of A Long Femoral Stem In The Treatment Of Proximal Femoral Fractures: A Report Of Four Cases

Failed Subtrochanteric Fracture How I Decide What to Do?

INTERTAN Nails Geared for Stability

The Lateral Trochanteric Wall A Key Element in the Reconstruction of Unstable Pertrochanteric Hip Fractures

Salvage of failed dynamic hip screw fixation of intertrochanteric fractures

The Journal of the Korean Society of Fractures Vol.16, No.1, January, 2003

Standard intramedullary (IM) nails are usually used

A comparative study of 30 cases of trochanteric fracture femur treated with dynamic hip screw and proximal femoral nailing

PFNA. With Augmentation Option.

HOW TO CITE THIS ARTICLE:

Gamma3 TM Fragment Control Clip

ORIGINAL ARTICLE. INTER TROCHANTERIC # NECK FEMUR FIXATION WITH TFN 250 CASES. Prasad Vijaykumar Joshi, Chandrashekar Yadav.

Page Proof 1 of 5. Fig. E1-A The INTERTAN nail was short or long.

Case Report. Antegrade Femur Lengthening with the PRECICE Limb Lengthening Technology

Zimmer ITST Intertrochanteric/ Subtrochanteric Fixation System. Abbreviated Surgical Technique

The Mechanical Properties Of Fixing Greater Trochanter Or Lesser Trochanter In Complex Four Part Intertrochanteric Fractures

PFNA. With Augmentation Option.

Preoperative Planning. The primary objectives of preoperative planning are to:

Is the biomechanical problem of trochanteric fracture solved?

Crossed Steinmann Pin Fixation In Supracondylar Femur Fractures In Adults A Case Series

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

MRIMS Journal of Health Sciences 2016;4(1) pissn: , eissn:

Type I : At the level of lesser trochanter Type II : Less than 2.5 cm below lesser trochanter. Type III : cm below lesser trochanter

PFNA-II. Proximal Femoral Nail Antirotation.

Comparative Study of Fixation Devices for Intertrochanteric Fractures

Trochanter Stabilization Plate for DHS Implants

Functional evaluation of proximal femoral fractures managed with cephalomedullary nailing by oxford hip score - A prospective study

A Prospective Study to Evaluate the Management of Sub-trochanteric Femur Fractures with Long Proximal Femoral Nail

DISLOCATION AND FRACTURES OF THE HIP. Dr Károly Fekete

PFN in trochanteric fractures: Clinico radiological outcome study

Types of Plates 1. New Dynamic Compression Plate: Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia

Comparative study between proximal femoral nail and proximal femoral nail antirotation in management of unstable trochanteric fractures

A Comparison of the Proximal Femoral Nail Antirotation Device and Dynamic Hip Screw in the Treatment of Unstable Pertrochanteric Fracture

INTERTROCHANTERIC FEMORAL FRACTURES TREATED BY DYNAMIC HIP SCREW

Hip Fractures. Anatomy. Causes. Symptoms

Angular Malalignment in Subtrochanteric and Proximal Shaft Femur Fractures after Intramedullary Nailing using SIGN Nails

Peritroch Hip Fractures. Robert M Harris MD. Hip Fractures. Factors Influencing Construct Strength: Uncontrolled factors 4/28/2016

PATENTED A-PFN. Antirotator Proximal Femoral Nail. Medical Devices

A 42-year-old patient presenting with femoral

Provision of Rotational Stability: Prevention of Collapse: Closed Fracture Reduction: Minimally Invasive Surgery with no Exposure of the Fracture:

Case Report Bilateral Distal Femoral Nailing in a Rare Symmetrical Periprosthetic Knee Fracture

Pelvis injuries Fractures of the femur (proximal,shaft) Dr Tamás Bodzay

JMSCR Vol. 03 Issue 08 Page August 2015

Raju Vaishya, Amit Kumar Agarwal, Nishint Gupta & Vipul Vijay

Femoral neck fracture during physical therapy following surface replacement arthroplasty: a preventable complication?

Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS)

Review of Proximal Nail Antirotation (PFNA) and PFNA-2 Our Local Experience

Proximal Femoral Shortening after Operation with Compression Hip Screws for Intertrochanteric Fracture in Patients under the Age of 60 Years

Pre-Operative Planning. Positioning of the Patient

Biomet Large Cannulated Screw System

STUDY OF RESULTS OF ENDER NAILING AND CANNULATED CANCELLOUS SCREW IN THE TREATMENT OF INTERTROCHANTERIC FRACTURE FEMUR

Technique Guide. DHS/DCS System. Including LCP DHS and DHS Blade.

Locked plating constructs are creating a challenge for surgeons.

Treatment of extracapsular hip fractures with the proximal femoral nail (PFN) : Long term results in 45 patients

ICUC Paper. The treatment of trochanteric fractures revisited: Pietro Regazzoni, Alberto Fernandez, Dominik Heim, Stephan M. Perren.

Principles of intramedullary nailing. Management for ORP

9/24/2015. Nailing IT Fractures: Long vs. Short Technique Tricks. Conflict of Interest. Short vs. Long Hip Nail

Closed reduction and internal fixation of fractures of the shaft of the femur by the Titanium Elastic Nailing System in children.

Results of Proximal Femoral Nail in Intertrochanteric Fracture of Femur

Screw Placement and Types Matter

5/31/2018. Ipsilateral Femoral Neck And Shaft Fractures. Ipsilateral Neck-Shaft Fractures Introduction. Ipsilateral Neck-Shaft Fractures Introduction

The Orthopaedic Enigma: A Simplified Classification

Distal Femur Fractures in The Elderly The Ideal Construct

Treatment of Femoral Intertrochanteric Fracture with Proximal Femoral Nail

Internal fixation of femoral neck fractures

Intramedullary Nailing of Subtrochanteric Fractures

Fracture fixation. Types. Mechanical considerations. Biomechanics of fracture fixation. External fixation. Internal fixation

Zimmer ITST Intertrochanteric/ Subtrochanteric Fixation System

Lower risk of implant failure and reoperation

Valgus subtrochanteric osteotomy for malunited intertrochanteric fractures : Our experience in 5 cases

)23( COPYRIGHT 2016 BY THE ARCHIVES OF BONE AND JOINT SURGERY

Aesculap Targon FN. Head Preserving Solution for Medial Femoral Neck Fractures. Aesculap Orthopaedics

TREATMENT OF SUBTROCHANTERIC FEMUR FRACTURES WITH PROXIMAL FEMORAL NAILS: A PROSPECTIVE STUDY

JOURNALOF ORTHOPAEDIC TRAUMA

Clinical outcomes of muscle pedicle bone grafting (Meyer's Procedure) in cases of old displaced femur neck fractures: A Study Of 20 Cases

Outcomes of Cephalomedullary Nailing in Basicervical Fracture

Practical Reduction Techniques: Diaphyseal Reduction. Philip Wolinsky University of California at Davis Medical Center

Large Distractor Femur

Cannulated Pediatric Osteotomy System (CAPOS). A single system of osteotomy blade plates and cannulated instrumentation.

COMPARATIVE STUDY OF MANAGEMENT OF DIAPHYSEAL FEMUR FRACTURE WITH INTRAMEDULLARY INTERLOCKING NAIL AND K. NAIL

Olecranon fracture. Lonnie Froberg, MD, Ph.D Rigshospitalet, Copenhagen University Hospital

Surgical Technique International Version

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016

Long-stem revision prosthesis for salvage of failed fixation of extracapsular proximal femoral fractures

Dynamic Hip Screw Compared to Condylar Blade Plate in the Treatment of Unstable Fragility Intertrochanteric Fractures

LISS DF and LISS PLT. Less Invasive Stabilization Systems for Distal Femur and Proximal Lateral Tibia.

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

AcUMEDr. LoCKING CLAVICLE PLATE SYSTEM

Importance of screw position in intertrochanteric femoral fractures treated by dynamic hip screw

Surgical Technique Guide PANTERA. Proximal Humerus Fracture Fixation Plate System

Approach Patients with Confidence

Posterolateral elbow dislocation with entrapment of the medial epicondyle in children: a case report Juan Rodríguez Martín* and Juan Pretell Mazzini

Transcription:

Journal of Orthopaedic Surgery and Research This Provisional PDF corresponds to the article as it appeared upon acceptance. Fully formatted PDF and full text (HTML) versions will be made available soon. Medial pelvic migration of the lag screw in a short gamma nail after hip fracture fixation: a case report and review of the literature Journal of Orthopaedic Surgery and Research 2010, 5:62 doi:10.1186/1749-799x-5-62 Xinning Li (xinning.li@gmail.com) Michael J Heffernan (mikeheff24@gmail.com) Christina Kane (chrissy.kane@gmail.com) Walter Leclair (wjlortho@aol.com) ISSN 1749-799X Article type Case report Submission date 23 March 2010 Acceptance date 27 August 2010 Publication date 27 August 2010 Article URL http://www.josr-online.com/content/5/1/62 This peer-reviewed article was published immediately upon acceptance. It can be downloaded, printed and distributed freely for any purposes (see copyright notice below). Articles in Journal of Orthopaedic Surgery and Research are listed in PubMed and archived at PubMed Central. For information about publishing your research in Journal of Orthopaedic Surgery and Research or any BioMed Central journal, go to http://www.josr-online.com/info/instructions/ For information about other BioMed Central publications go to http://www.biomedcentral.com/ 2010 Li et al., licensee BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Medial pelvic migration of the lag screw in a short gamma nail after hip fracture fixation: a case report and review of the literature Xinning Li*, Michael J Heffernan, Christina Kane, Walter Leclair. University of Massachusetts Medical Center, Worcester, MA, USA Xinning Li * First and corresponding author University of Massachusetts Medical Center Dept. of Orthopaedic Surgery 55 Lake Avenue North Worcester, MA 01655 USA Xinning.li@gmail.com (508) 334-1000 (phone) (508) 334-7273 (fax) Michael J Heffernan University of Massachusetts Medical Center Dept. of Orthopaedic Surgery 55 Lake Avenue North Worcester, MA 01655 USA mikeheff24@gmail.com Christina Kane University of Massachusetts Medical School 55 Lake Avenue North Worcester, MA 01655 USA chrissy.kane@gmail.com Walter Leclair Dept. of Orthopaedic Surgery University of Massachusetts Medical Center 55 Lake Avenue North Worcester, MA 01655 USA walter.leclair@umassmed.edu 1

ABSTRACT Hip fractures are a common injury among the elderly. Internal fixation with an intramedullary (IM) system has gained popularity for the treatment of intertrochanteric femur fractures. Multiple complications associated with IM fracture fixation have been described, however, we report a rare complication of medial pelvic migration of the lag screw of a short IM nail in a stable construct ten weeks post surgery. The patient was subsequently treated with Lag Screw removal and revision surgery with a shorter Lag Screw and an accessory cannulated screw acting as a de-rotational device. The patient did well with the revision surgery and was able to return to full activities. BACKGROUND Hip fractures are a common injury among adults ages 65 and older, occurring in approximately 300,000 individuals yearly [1,2]. An estimated 1.66 million hip fractures occurred worldwide in 1990 and the number is expected to increase to 6.26 million by the year 2050 [3]. Internal fixation with an intramedullary (IM) system has gained popularity for the treatment of intertrochanteric femur fractures. This construct provides both load sharing properties while allowing immediate mobilization [4,5]. Complications of IM hip fracture fixation include but not limited to infection, mal or non union, avascular necrosis, hardware failure, neurovascular injuries, fracture of the femur distal to the implant, and death [3-5]. A common complication associated with the IM system is lag screw cut-out from the femoral head which leads to varus collapse of the fracture and non-union [6-8]. Other rare complications related to the lag screw include medial pelvic migration [9], lateral migration [10], extracorporeal extrusion from the body [11], and sigmoid perforation [8]. Furthermore, medial 2

migration of the proximal femoral element seen with the Proximal Femoral Nail described as the Z Effect have also been reported [12]. We believe this is the first case report presenting medial pelvic migration of the lag screw or femoral neck element of a short Gamma 3 IM nail in a locked and stable construct ten weeks post surgery. The patient was subsequently treated with Lag Screw removal and revision surgery with a shorter Lag Screw and an accessory cannulated screw acting as a de-rotational device. CASE PRESENTATION The patient was a 77 year old Caucasian female who experienced a mechanical fall onto her right side and presented to our emergency department. On physical examination, the patient had a shortened and externally rotated right lower extremity that was painful to log-roll and axial load. Otherwise the patient was neurovascularly intact. The initial radiographs showed a 3- part inter-trochanteric hip fracture with the lesser trochanter as a separate fragment (Fig. 1). The patient was taken to the operating room after medical clearance for a closed reduction and insertion of a short Gamma 3 nail (125 degrees x 11mm x 180 mm, Stryker, Kalamazoo, MI) according to standard technique. A 100 mm lag screw was inserted close to the subchondral bone but without penetrating the femoral head with a total Tip to Apex Distance (TAD) of 13 mm (AP=5mm and Lateral=8mm). After confirmation of firm fixation of the lag screw, a distal locking screw was inserted in the dynamized position of IM nail. A set screw was then placed to prevent rotation of the lag screw. There was no intra-operative complications and post operative anterior-posterior and lateral hip radiographs are seen in Figs. 2 and 3. Post-operatively, the patient was discharged to rehab facility on day 3. On the sixth week post operative visit, the patient had no complaints and she has been weight bearing as tolerated. Anterior posterior right hip radiograph shows some callus formation 3

and compression of the lag screw without medial migration (Fig. 4). At the ten week follow up visit, right hip radiographs revealed that the lag screw along with the short IM nail construct had migrated medially through her femoral head and through the medial wall of her acetabulum (Fig. 5), however, the patient have been ambulating on her right lower extremity and did not complaint of hip pain or have any neurovascular deficits. Patient was subsequently admitted and underwent revision surgery with removal of the lag screw and placement of a shorter lag screw after intra-operative stress confirmation of no visible fracture motion. An accessory cannulated screw was then placed anterior and parallel to the Lag Screw to provide de-rotational component (Fig. 6). The distal locking screw of the IM nail was then removed to provide axial dynamization of the nail. The patient tolerated the procedure well and continued to do well clinically at the one year follow-up (Fig. 7) and currently back to full activities with full weight bearing and cane assisted ambulation. DISSCUSION Intertrochanteric hip fractures are very common among the elderly [13,14]. There are many different fixation devices developed for the management of these fractures, with majority of them belonging to either the intrameduallary or the sliding hip plate category. The advantages of intrameduallary fixation system are decreased intra-operative blood loss and operating room time with immediate load-bearing. Better clinical outcomes have also been reported when utilized in the unstable fracture pattern when compared to the sliding hip plates [4,15]. However, higher complication rates associated with distal femur fracture and lag screw cut out have also been reported with the IM system [4]. Several rare complications related to the lag screw in an IM hip fixation system have been seen in the literature as case reports. Tauber et al. reported a case of sigmoid perforation 4

with free medial migration of the lag screw in a Gamma nail. The complication presented 8 weeks post operative without any history of trauma. The sigmoid perforation presented at 12 weeks as retroperitoneal abscess and sepsis. No intra-operative complications were reported from surgery and the authors could not explain the cause of this complication [8]. Another report in the literature described spontaneous extracorporeal extrusion of the Proximal Femoral Nail lag screw from the body of a patient over one year from the date of surgery. Given that the PFN system has no build in mechanism to stop lateral migration of the lag screw, the authors urged for a modification of the PFN system [11,16]. Another case of lateral lag screw migration without extrusion from the skin in the setting of a minor trauma has also been reported [10]. Walking and normal weight bearing subjects the implant and bone surface to combined axial and torsional load that may play a role in lag screw migration. Werner-Tutschku et al. described a complication of the PFN when the superior anti-rotation screw penetration into the femoral head or pelvis while the distal femoral neck element (lag screw) migrating laterally. They termed this the Z-Effect which was seen in 7.1% of their cases (7/70) associated with the PNF with two femoral neck elements. The authors attributed this complication to bad primary reposition in varus which causes collapse of the fracture and sliding of the inferior neck screw laterally while the superior anti-rotational screw migrated medially [6,12]. This Z-Effect or medial migration of the femoral neck element (FNE) was recently analyzed biomechanically. Several different IM hip fixation systems where tested and medial migration of the femoral neck element was reproduced reliably in each. The authors found that certain fracture patterns (deficient lateral buttress or an unstable medial calcar) that led to nail toggling within the femoral canal are more likely to cause medial migration of the FNE in implants with only one FNE. Preventing nail toggling was able to prevent medial migration of the FNE. However, the exception to the rule was seen in the PFN with two FNEs, as preventing nail toggling did not 5

prevent medial migration of the distal Lag Screw. Thus the authors concluded a different mechanism other than nail toggling may be responsible for the Z-Effect seen in the dual screw PFN systems [6]. Another biomechanical study showed that specimens with the greatest mechanical mismatch between femoral head and neck exhibit lateral migration of the distal femoral neck element of a dual screw IM system. Specifically, migration is seen if the compressive strength of the femoral head is much greater than the femoral neck, which simulates fractures that have significant medial cortex comminution that are prone to varus collapse [17]. In the presenting case, the patient had an unstable intertrochanteric hip fracture with the discontinuity of the medial cortex. A short Gamma 3 nail was placed with the Lag Screw locked rotationally by the set screw. The distal locking screw was then placed in the dynamized position of the Gamma nail. We theorized that over time with the compression of the fracture and dynamization of the nail in the setting of an unstable fracture pattern, there was toggling of the nail within the intrameduallary canal which led to the medial migration of the Lag Screw with repeated axial loading. This is the mechanism as proposed by Weil et al. in their biomechanical study [6]. Further penetration of the femoral head and eventual migration into the pelvis are more likely to be seen with osteoporotic bone [17]. Intra-operatively during the revision surgery, the Lag Screw was felt to be well fixed into the acetabulum even in the setting of medial migration into the pelvis. The patient was asymptomatic, which lead us to believe that the Lag Screw may have migrated at the center of rotation into the acetabulum thus with hip range of motion, the patient did not experience significant pain. Furthermore, we stressed the fracture site intra-operatively after removal of the Lag Screw and there was no fracture motion, which indicated that the fracture was well healed. Therefore, decision was made to replace the longer Lag Screw with a shorter one. We also wanted a de-rotational component to the IM construct to further prevent spinning of the femoral head on the shorter Lag Screw, therefore, a 6

second cannulated screw was placed into the femoral neck anterior and parallel to the shorter Lag Screw. Furthermore, the shorter Lag Screw was also locked rotationally by the set screw. The patient did very well with the revision surgery and was able to return to full activities. CONCLUSION Although the apparent mechanisms of the femoral neck element (lag screw) medial pelvic migration are undefined, incidents occur in part due to poor device placement during surgery leading to varus collapse post operatively, unstable fracture patterns especially with comminution of the medial calcar or lateral cortex, and post-operative weight-bearing on osteoporotic bone have been reported as contributing factors in literature. The medial Lag Screw migration seen in our patient is likely a combination of the above mentioned factors. Even with application of the set cap which stabilizes the construct in torsion, axial load may still cause toggling of the nail within the femoral canal leading to medial migration similar to what is seen in the Z-Effect. It s also important to demonstrate fracture healing by stressing the hip intraoperatively. If there is no fracture motion, then replacing the original Lag Screw with a shorter Lag Screw and using a cannulated screw as a de-rotational device can be used as a surgical management option. Attention should be paid to the position of the IM implant to minimize varus collapse in order to decrease risk of medial migration of the Lag Screw. CONSENT Written informed consent was obtained from the patient for publication of this case report and any accompanying images. COMPETING INTERESTS All authors declare no conflicts of interest in relations to this manuscript. 7

AUTHORS CONTRIBUTIONS XL contributed to the data collection / interpretation, figures, and drafting / revising of the entire manuscript. MH and CK contributed to the figure collection and to the introduction and case presentation section. The patient was evaluated and operated by WL. The final manuscript was seen and approved by all authors before submission. REFERENCES 1. Ehmke L,Fitzpatrick D,Krieg J et al. Lag screws for hip fracture fixation: Evaluation of migration resistance under simulated walking. Journal of Orthopaedic Research. 2005;23:1329-35. 2. Richmond J,Aharonoff G,Zuckerman J et al. Mortality risk after hip fracture. Journal of Orthopedic Trauma. 2003;17:53-6. 3. Kenzora J,McCarthy R,Lowell J et al. Hip fracture mortality: relation to age, treatment, preoperative Illness, time of surgery, and complications. Clinical Ortho Related Research. 1984;186:45-56. 4. Chinoy M,Parker M. Fixed nail plates versus sliding hip systems for the treatment of trochanteric femoral fractures: a meta analysis of 14 studies. Injury. 1999;30:157-63. 5. Bridle S,Patel A,Bircher M et al. Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw Journal of Bone and Joint Surgery Br. 1991;73:330-34. 6. Weil Y,Gardner M,Mikhail G et al. Medial migration of intramedullary hip fixation devices: a biomechanical analysis. Arch Orthop Trauma Surg. 2008;128:227-234. 8

7. Stocker R,Maier R. Medial migration of lag screw in gamma nailing. Is it the result of teechnical or implantation error? Unfallchirurg. 2005;108:79-80. 8. Tauber M,Resch H. Sigmoid perforation after medial migration of lag screw in gamma nailing. Arch Orthop Trauma Surg. 2006;126:118-22. 9. Ramkumar U,Saffar T,Thinakarajan H et al. Pelvic migration of lag screw from a nailing device. Injury Extra. 2006;37:53-55. 10. Lasanianos N,Mouzopoulos G,Georgilas I. Hip screw lateral migration with no cutout or non-union implication: a case report. Cases Journal. 2009;2:6419. 11. Gun-ll I,Suk-Hyun L. Spontaneous extracorporeal extrusion of the lag screw from a proximal femoral nail. Injury Extra. 2006;37:147-50. 12. Werner-Tutschku W,Lajtai G,Schmiedhuber G et al. Intra- and perioperative complications in the stabilization of per- and subtrochanteric femoral fractures by means of PFN. Unfallchirurg. 2002;105:881-885. 13. Schipper I,Steyerberg E,Castelein R et al. Treatment of unstable trochanteric fractures. Randomised comparison of the gamma nail and the proximal femoral nail. Journal of Bone and Joint Surgery Am. 2004;86:86-94. 14. Kannusa P,Parkkaria J,Sievänena H et al. Epidemiology of hip fractures. Bone. 1996;18:57-63. 15. Park S,Yang K,Yoo J et al. The treatment of reverse obliquity intertrochanteric fractures with the intramedullary hip nail. The Journal of Trauma injury, infection, and critical care. 2006;65:852-57. 16. Leung K,So W,Shen W et al. Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients. Journal of Bone and Joint Surgery Am. 1992;74:345-51. 9

17. Strauss E,Kummer F,Koval K et al. The "Z-Effect" phenomenon defined: A laboratory study. Journal of Orthopaedic Research. 2007;25:1568-73. Figure legends Figure 1: Anterior-Posterior radiograph demonstrating a three part intertrochanteric hip fracture on the right side. Discontinuety of the medial contex is seen with the less trochanter fracture fragment. Figure 2: Post-operative AP radiograph showing the reduction of the three part hip fracture with placement of the short Gamma 3 intrameduallary nail. Figure 3: Post-operative Lateral radiograph showing the reduction of the three part hip fracture with placement of the short Gamma 3 intrameduallary nail. Figure 4: Anterior-Posterior radiographs at the six week post operative clinic visit shows compression of the Lag screw without medial migration. Figure 5: Medial migration of the Lag Screw into the pelvis at the ten week post operative clinic visit. Figure 6: Intra-operative fluoroscopic image at the time of revision surgery. A shorter Lag Screw was placed and another accessory cannulated screw placed anterior and in parallel to the Lag Screw. Figure 7: Most recent AP hip radiograph at the one year post revision clinic visit shows good implant position and a well healed intertrochanteric hip fracture. 10

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

Figure 7