Surgical Technique Carpal Fusion

Similar documents
Surgical Technique. Customer Service:

Surgical Technique 4.5/8.5MM BEAMING SYSTEM. Customer Service:

Integra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE

Surgical Technique. DISCLOSURE: This device is not approved for sale in the U.S.A. Customer Service:

Acutrak 2 Headless Compression Screw System Micro, Mini, and Standard Screws. Supplemental Use Guide Four Corner Fusion

Surgical Technique Guide

Surgical Technique Guide

Acu-Loc Wrist Spanning Plate System. Surgical Technique

ORION Screw System PRODUCT INFORMATION

2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

2.0. The Unrivaled Solution for MidFoot Fusion. Reinforced Bone Bridge. Zero Profile. Because Uniform Compression is Better Compression

Conventus CAGE PH Surgical Techniques

CANNULINK. Intraossous Fixation System SURGICAL TECHNIQUE

Surgical Technique. Forearm Fracture Solutions

Percutaneous Scaphoid Fixation: A Volar Approach

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

CHARLOTTE. 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE

Technique Guide Hammertoe Correction System

MICRONAIL. Intramedullary Distal Radius System SURGICAL TECHNIQUE

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

System. Humeral Nail. Surgical Technique

Headless Compession Screw 4.5 / 6.5 SURGICAL TECHNIQUE. Titanium or Stainless Steel. Cannulated Headless Design. Multiple Thread Options.

INnate. Surgical Technique Guide. Anatomic Fixation in Your Hands. The INnate Implant

Headless Compession Screw 2.5 / 3.0

Chapter 19. Arthroscopic Bone Grafting for Scaphoid Nonunion. Introduction. Operative Technique. Radiocarpal and Midcarpal Exploration

The Flower Four Corner Fusion Plate

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation

DYNAMIC, TRANSVERSE COMPRESSION. Low Profile, Anatomic Design, Type II Anodized. Mechanical Compression Designed to Stimulate the Fusion Process

Correction System. Surgical Technique

CHARLOTTE. 3.0 and 4.3 Multi-Use Compression Screws SURGIC A L T ECHNIQUE

Motec. Wrist Joint Arthrodesis Metacarpal Taper and Radius Connector

Clover Staple. Surgical Technique

Correction System. Surgical Technique

CHARLOTTE. 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE

Locking Ankle Plating System. Surgical Technique

Biotrak Resorbable Fixation System

DISTAL ELBOW SET. proximal ulna plate SURGICAL TECHNIQUE GUIDE

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

AcUMEDr. FoREARM ROD SYSTEM

The Flower Proximal Humerus Plate

Hallux Valgus Deformity OPERATIVE TECHNIQUE

CHARLOTTE. Compression Staple

2.4 mm Variable Angle Locking Intercarpal Fusion System

Motec. Wrist Joint Arthrodesis Metacarpal Nail and Radius Connector

Humeral SuturePlate. Surgical Technique

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Axi+LineTM Proximal Bunion CorrectionSystem. Surgical Technique

Lapidus Arthrodesis System Instructions for Use

MetaCun DuoMetaCun. Midfoot Fusion Locking Plate System. Surgical Technique and Ordering Information

The Flower Medial Column Fusion Plate

Surgical Technique. Targeter Systems Overview

VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

ReMotion Total Wrist System

CSS. Cannulated Screw System SURGICAL TECHNIQUE

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

Integra. ADVANSYS Plating System SURGICAL TECHNIQUE

Wrist Fixation System

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

SURGICAL TECHNIQUE GUIDE PROTEAN. radial head plate. As described by: Jorge L. Orbay, M.D. Miami Hand & Upper Extremity Institute Miami, Florida

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Flower Medium Headless & Cannulated Screws

Hand Fracture System. Surgical Technique

Instrument and Implant for wrist fracture

Chapter 13. Arthroscopic Lunotriquetral Arthrodesis and Head of the Hamate Resection. Introduction. Operative Technique (Fontes) Midcarpal Exploration

Integra. Freedom Wrist Arthroplasty System SURGICAL TECHNIQUE

SURGICAL TECHNIQUE GUIDE

SURGICAL TECHNIQUE GUIDE PROTEAN. radial head plate. As described by: Jorge L. Orbay, M.D. Miami Hand & Upper Extremity Institute Miami, Florida

Contents. Chapter 1 4 Chapter Chapter Chapter Chapter 5 15

TABLE OF CONTENTS. Limited intercarpal joint arthrodesis (including isolated capitolunate, two-column and four-corner fusions)

Technique Guide. 6.5 mm Midfoot Fusion Bolt. For intramedullary fixation of the medial column of the foot.

Acu-Loc 2 Wrist Plating System

Wrist Fusion Instrument and Implant Set.

CHARLOTTE Lisfranc. Recontruction System SURGICAL TECHNIQUE

Surgical Technique. Wrist Plating System

LCP Wrist Fusion Set. Anatomic plates for total wrist fusion.

OptiLock Periarticular Plating System For Distal Tibial Fractures. Surgical Technique

MetaFix Ludloff Plate

Locking Radial Head Plates

PEDUS-L. Locking Plantar Lapidus Plate

Flower Opening Wedge Plate

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

SpeedTip CCS 2.2, 3.0

SURGICAL TECHNIQUE GUIDE: LAPIDUS ARTHRODESIS USING THE PHANTOM INTRAMEDULLARY NAIL INTRAMEDULLARY NAIL

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

A sequenced approach to flush graft placement. GLENOID BONE LOSS SYSTEM Procedural Solution

Integra. PyroSphere System SURGICAL TECHNIQUE

upper extremity fixation system

Volar Distal Radius Plating System Surgical Technique

Volar Distal Radius Plating System Surgical Technique

Bunion Correction System

Integra. Silicone PIP Implant SURGICAL TECHNIQUE

Acu-Loc Wrist Plating System. Surgical Technique

6.5 mm midfoot fusion bolt

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

Acu-Loc 2 Wrist Plating System. Surgical Technique

Motec. Wrist Joint Arthrodesis Straight Double Taper

Forefoot/Midfoot Plating System

Jacqueline C. Vanderzanden, Brian D. Adams & Justin J. Guan

Transcription:

Carpal Fusion Patent and Patent Pending CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician.

INDICATIONS FOR USE The Extremity Medical Lag Screw and X-Post System is intended for the reduction and internal fixation of arthrodeses, osteotomies, intra-articular and extra-articular fractures and nonunions of the small bones of the hand and wrist. NOTE: This technique describes the steps for hardware implantation as used in a Capito-Lunate fusion. Please follow the same steps as listed in this procedure for use with other carpal bone fusions. Pre-Operative Planning - Templating The Extremity Medical Lag Screw and X-Post System provides several X-Post options (45, 60, or 75 ). Use the X-ray template to pre-operatively determine X-Post positioning and angle. STEP 1 - Exposure & Joint Preparation A standard longitudinal incision, which begins at Lister s tubercle and extends distally 6-8cm, is performed over the radiocarpal joint. Incise and elevate the capsule and expose the carpal bones. Removal of the scaphoid is at the discretion of the surgeon. Prepare the carpal bone surfaces for fusion by removing the remaining articular cartilage and subchondral bone. After removal of the cartilage and subchondral bone of the articulating surfaces, generous amounts of cancellous bone graft should be inserted between the bones. STEP 2 - Provisional Fixation Align the carpals into the ideal orientation with your preferred method. Provisionally pin the bones. The provisional fixation may be left in throughout hardware implantation. Note: When placing provisional pins, care must be taken to allow for adequate space to implant hardware. 1. 2. 1) A provisional Ø1.6 Guidewire may be used to pin the Capito-Lunate joint. 2) A compression (Wolfe) clamp with parallel Ø1.6 Guidewires may be used to fixate the bones during hardware implantation.

STEP 3 - X-Post Guidewire Insert a Ø0.9mm Guidewire in the Lunate parallel to the Capito-Lunate joint. This Guidewire will serve as an alignment wire for the X-Post orientation. Verify proper positioning with fluoroscopy. Note: To allow for more orthogonal placement of the Lag Screw, the initial X-Post Guidewire wire may be canted up to 20 from proximal-dorsal to distal-volar. 15-20 STEP 4 - X-Post Depth Measurement Place the depth gauge over the X-Post Guidewire and down to bone to determine the length of the X-Post. Note: The Depth Gauge is a two-sided gauge. Read this measurement from the side labeled X-Post Depth. It is recommended that the X-Post be countersunk 1-2mm below the cortical surface. This difference can be factored into the final implant selection by selecting an X-Post 1-2mm shorter than the measured length.

STEP 5 Preparation for X-Post : Pilot Drill Drill to the measured depth utilizing the Ø2.7mm Cannulated Drill. Either the Short or Long Tapered Guide may be used to prevent soft tissue impingement. STEP 6 - Preparation for X-Post : Countersink Place the cannulated X-Post Countersink over the Guidewire and advance by hand until the depth line is no longer visible.

STEP 7 - X-Post Insertion Select the appropriate X-Post (length based on the Step 4 measurement and the angle determined from the pre-operative templating). Align the laser marked arrows of the Ø2.0 mm Hex Driver to markings on the implant. When the implant and Hex Driver are aligned in this fashion, the laser marked arrows will indicate the direction of the Lag Screw. Insert the X-Post until countersunk 1-2mm below the cortical rim. The laser marked arrow should be facing the intended fusion area. STEP 8 - Clear Additional Bone In order to gain access to the implant eyelet, remove any obstructing bone by hand using the X-Post Clearing Tool. This will allow the guide to seat properly. Alternatively, a rongeur can be used to remove any impinging bone. NOTE: Any difficulty seating the Drill Guide in Step 9 could be due to bony interference at the implant eyelet.

STEP 9 Lag Screw Guidewire Insertion Insert the Long Tapered Guide into the eyelet of the X-Post. Ensure that the guide is seated into the taper of the implant to the level where the head of the guide is no longer visible. This will keep the Guidewire concentric with the eyelet, and allows for optimal locking of the Lag Screw and X-Post construct. Once the Long Tapered Guide is seated, drive a Ø0.9mm Guidewire through the hole of the guide to the appropriate level. Verify the positioning of the Guidewire under fluoroscopy. Optional: If provisional fixation has not already been applied, the supplemental holes on the guide may be utilized for temporary fixation. STEP 10 - Lag Screw Depth Measurement Measure the length of the Lag Screw by placing the Depth Gauge over the Guidewire and down to the bone. Note: The Depth Gauge is a two-sided gauge. Read this measurement from the side labeled Lag Screw.

STEP 11 - Pilot Drill for Lag Screw Drill utilizing the Ø2.0mm Cannulated Drill. Align the first depth marking to the top of the Tapered Guide. Based on this zero reference, drill to the depth measurement previously recorded. Graduations on drill are in 10mm increments. STEP 12 Insert Lag Screw Insert the Lag Screw under TWO finger pressure until tactile compression is felt, and the visualization shows the Lag Screw flush against the X-Post. With the tapered Lag Screw, the Morse Taper engagement should be felt as the tapers engage. Note: Remove any provisional wires prior to final tightening, this will ensure maximum compression is applied.

FINAL POSITIONING If additional fixation is determined necessary, an additional headed or headless screw may be implanted per standard techniques. Four-Corner Fusion When performing a four-corner fusion, it is critical that the Triquetrum-Hamate joint surface be prepared before the Capito-Lunate joint is fixated. It is recommended to follow these steps in performing a four-corner fusion: 1. Prepare the surfaces fully 2. Harvest and insert bone graft 3. Implant both X-Posts 4. Implant the Lag Screws sequentially

POSTOPERATIVE TREATMENT Subsequent to incision closure, patients should initially be immobilized in a well-padded splint for the first two weeks postoperatively. Following repeat incision assessment and suture removal, standard post-operative protocols for arthrodesis, as preferred by the surgeon, should be followed. Progression of movement and transition out of cast immobilization should be based on bone quality and healing rates, and will likely be individualized on a case by case basis. IMPLANT REMOVAL Remove any tissue ingrowth from the Lag Screw. Insert the 2.0 Hex Driver into the Lag Screw and completely remove it by turning counterclockwise. Insert the 2.0 Hex Driver into the Post and remove it by turning counterclockwise.

Supplemental INDICATION Information Placement of the Lag Screw and X-Post construct is based on surgeon preference and access. 1. Radiolunate Fusion Approach and Exposure A dorsal longitudinal or transverse incision centered over the radiocarpal joint is performed. A transverse or longitudinal capsulotomy Is performed at the discretion of the surgeon. The articulating surfaces should be debrided down to bleeding subchondral or cancellous bone. X-Post Placement Typically, the X-Post is placed centered between the radiolunate joint surfaces and tangent to the distal articulating surface of the lunate. This Guidewire must be centered between the radiolunate and Capito-Lunate joint surfaces to allow sufficient room for the threads of the implant. Verify proper positioning with fluoroscopy.

Supplemental INDICATION Information Placement of the Lag Screw and X-Post construct is based on surgeon preference and access. 2. Thumb Basal Joint Fusion Approach and Exposure An L-shaped Wagner incision is typically utilized for this procedure. Care must be taken to identify and protect sensory nerve branches in the subcutaneous tissues. The thenar muscles are reflected from the metacarpal to expose the basal joint while carefully protecting the insertion of the APL. The capsule is incised on the radial and dorsal aspect of the trapeziometacarpal joint to fully expose the articulating surface. A Ø0.9mm Guidewire Is inserted from radial to ulnar in the trapezium midway between the articular surfaces, and parallel to the TM joint surface. Verify positioning of the Guidewire via fluoroscopy. At this point, the position of the fusion is selected, and a Ø1.6mm Guidewire is inserted between the thumb and index metacarpals to provisionally fix the position of fusion. Fluoroscopy is used to confirm the selected position. Ideally, the tip of the thumb should flex to pinch the middle phalanx of the partially flexed index finger. When final position has been selected and confirmed, the cutting block is applied and aligned over the distal articular surface so as to cut a tangent to the articular surface and resect a minimum of distal trapezial bone. The cutting block is stabilized with two.035 Guidewires. A Ø0.038mm oscillating saw is used to make the trapezial cut. The block is then lifted and advanced to position over the base of the thumb metacarpal, to create a parallel cut and remove the articulating cartilage and a minimum of the subchondral bone of the MC. The block and all resected bone and cartilage is then removed with a fine rongeur. Care must be taken to assure that there are no remaining spurs that would prevent perfect coaptation of the resected surfaces. If necessary, a 2mm burr can be used to further freshen the apposing articular surface. Remove the transmetacarpal Guidewire from the index MC, manually impact the thumb metacarpal against the trapezial surface, and then re-insert the transmetacarpal Guidewire into the index. Final positioning should be confirmed with fluoroscopy.

NOTES:

NOTES:

IMPLANT SPECIFICATIONS X-Post LAG SCREWS CarpalFiX X-Post (Gold) Specifications Major Minor Angles Lengths Diameter Diameter 45, 60, 75 10-18 mm 4.0mm 2.7mm (By 2mm increments) Length Lag Screw Specifications Thread Length Major Diameter Minor Diameter Standard 14-30mm L-8mm 3mm 2mm (By 2mm increments) Short Thread 14-30mm 14, 16, 18mm - 6mm 3mm 2mm (By 2mm increments) 20, 22mm - 8mm 24, 26mm - 10mm 28, 30mm - 12mm

X-Posts Implant Description Qty 4.6 X-Posts (45 ) 127-46410 X-Post (45 ) 4.6 X 10mm 2 127-46412 X-Post (45 ) 4.6 X 12mm 2 127-46414 X-Post (45 ) 4.6 X 14mm 2 127-46416 X-Post (45 ) 4.6 X 16mm 2 127-46418 X-Post (45 ) 4.6 X 1 8mm 2 4.6 X-Posts (60 ) 127-46610 X-Post (60 ) 4.6 X 10mm 2 127-46612 X-Post (60 ) 4.6 X 12mm 2 127-46614 X-Post (60 ) 4.6 X 14mm 2 127-46616 X-Post (60 ) 4.6 X 16mm 2 127-46618 X-Post (60 ) 4.6 X 18mm 2 4.6 X-Posts (75 ) 127-46710 X-Post (75 ) 4.6 X 10mm 2 127-46712 X-Post (75 ) 4.6 X 12mm 2 127-46714 X-Post (75 ) 4.6 X 14mm 2 127-46716 X-Post (75 ) 4.6 X 16mm 2 127-46718 X-Post (75 ) 4.6 X 18mm 2 Lag Screws Implant Description Qty 3.0 Lag Screws 127-30214 Lag Screw (Cannulated Tapered) 3.0 x 14mm 2 127-30216 Lag Screw (Cannulated Tapered) 3.0 x 16mm 2 127-30218 Lag Screw (Cannulated Tapered) 3.0 x 18mm 2 127-30220 Lag Screw (Cannulated Tapered) 3.0 x 20mm 2 127-30222 Lag Screw (Cannulated Tapered) 3.0 x 22mm 2 127-30224 Lag Screw (Cannulated Tapered) 3.0 x 24mm 2 127-30226 Lag Screw (Cannulated Tapered) 3.0 x 26mm 2 127-30228 Lag Screw (Cannulated Tapered) 3.0 x 28mm 2 127-30230 Lag Screw (Cannulated Tapered) 3.0 x 30mm 2 3.0 Short Thread Lag Screws 127-30414 Short Thread Lag Screw (Cannulated Tapered) 3.0 x 14mm 2 127-30416 Short Thread Lag Screw (Cannulated Tapered) 3.0 x 16mm 2 127-30418 Short Thread Lag Screw (Cannulated Tapered) 3.0 x 18mm 2 127-30420 Short Thread Lag Screw (Cannulated Tapered) 3.0 x 20mm 2 127-30422 Short Thread Lag Screw (Cannulated Tapered) 3.0 x 22mm 2 127-30424 Short Thread Lag Screw (Cannulated Tapered) 3.0 x 24mm 2 127-30426 Short Thread Lag Screw (Cannulated Tapered) 3.0 x 26mm 2 127-30428 Short Thread Lag Screw (Cannulated Tapered) 3.0 x 28mm 2 127-30430 Short Thread Lag Screw (Cannulated Tapered) 3.0 x 30mm 2 System Accessories Instrument Description Disposable Instruments 101-00004 Guidewire - 0.9mm 10 101-00006 Guidewire - 1.6mm 5 101-00011 Cannulated Drill 2.0mm 2 101-00022 Cleaning Brush - 0.9mm 1 127-00004 X-Post Countersink 4.6mm 1 127-00007 CarpalFiX X-Ray Template 1 127-00027 Cannulated Drill 2.7mm 2 Re-Usable Instruments 101-00008 Guidewire Holder - 0.9mm 1 101-00009 Guidewire Holder - 1.6mm 1 102-00017 AO Quick Connect Handle 1 118-00020 2.0 Hex Driver 2 127-00000 CarpalFiX Instrument Tray 1 127-00001 CarpalFiX Implant Caddy 1 127-00002 Long Tapered Guide 4.6mm 1 127-00003 Short Tapered Guide 4.6mm 1 127-00005 X-Post Clearing Tool 1 127-00006 Small AO Handle 1 127-00010 Depth Gauge 0.9mm 1 300 Interpace Parkway Suite 410 Parsippany, NJ 07054 Phone: 973.588.8980 Fax: 888.499.0542 0086 LBL-127-99102-EN Rev C 4/2015