cobas PCR Media Uni Swab Sample Kit

Similar documents
cobas PCR Media Dual Swab Sample Kit

CMV FEP ALA For nucleic acid amplification of CMV DNA and Fluorescence detection with End Point analysis (FEP) on Aladin (Sacace)

Strep-a-Test Twister Test

Chlamydia trachomatis (CHLa)Test Kit

Rotavirus Test Kit. Instructions For Use. Format: Cassette Specimen: Fecal Extract Catalog Number: VEL-001-ROTA

Murex Chlamydia Verification Kit

PLATELIA CANDIDA Ab PLUS Negative and Positive Controls. Quality Control Human Sera

Sputum DNA Collection, Preservation and Isolation Kit 50 Individual Devices

1. Identification of the substance / preparation and of the company. Trade name: Enzymatic cleaning. Part number:

SAFETY DATA SHEET. according to 1907/2006/EC, Article 31. Zinc Polycarboxylate Cement

SAFETY DATA SHEET According to EC Directive 1907/2006/EC.

HBeAg and HBeAg Ab ELISA Kit

Oral Specimen Collection Device

1. Identification of the substance/preparation and of the company

Safety Data Sheet Product Name: Heparin / PF4 Serum Panel - For In Vitro Diagnostic Use Only

Virus Nucleic Acid Isolation Kit

Rapid-VIDITEST. Influenza A+B

Human Influenza A (Swine Flu) Rapid test

May be harmful if inhaled. May cause respiratory tract irritation. Skin. May be harmful if absorbed through skin. May cause skin irritation.

: Sweat Controls for Cystic Fibrosis Testing

Purified Human Complement Proteins A400 Series

Commercial product name: SED-CHEK 2 ESR CONTROLS

Technical Bulletin No. 98b

Genomic DNA Isolation Reagent Kit (Blood/Cultured Cell/Tissue)

Pulpdent Corporation Revision Date: May 6, 2014 Safety Data Sheet

Pulpdent Corporation Revision Date: January 1, 2014

Safety Data Sheet. May cause stomach ache, diarrhoea, nausea and vomiting.

ANTIBODY SCREENING by Uni-Gold Recombigen HIV

Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/28/2010 Print Date 08/24/2011

Fetal Cell Count kit

Material Safety Data Sheet. Catalog Number:

1.2 Relevant identified uses of the substance or mixture and uses advised against Laboratory chemical

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Genomic DNA Isolation Kit (Blood/Cultured Cell/Fungus)

SAFETY DATA SHEET (SDS) According to EC Regulation 1907/2006/EC and Subsequent Amendments

87491 Chlamydia trachomatis, amplified probe technique Neisseria gonorrhoeae, amplified probe technique. Virology (Performed on Mpls campus)

Rapid-VIDITEST Swine Flu

MBead Buffy Coat Genomic DNA Kit

Guide for Use. Advance Plus Touch Free Intermittent Catheter System

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/27/2010 Print Date 07/09/2010

MATERIAL SAFETY DATA SHEET In accordance with CE Regulation n 1907/2006. Annex II.

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

ABIOpure TM Viral (version 2.0)

MATERIAL SAFETY DATA SHEET In accordance with CE Regulation n 1907/2006. Annex II.

Safety Data Sheet TENARIS

Safety Data Sheet CITRA FORCE

Drew University Bloodborne Pathogens Exposure Control Plan and Procedures

Purified Human Complement Proteins A400 Series

Pulpdent Corporation Revision Date: May 1, 2017 Safety Data Sheet

H312: Harmful in contact with skin. H319: Causes serious eye irritation. H351: Suspected of causing cancer.

Pulpdent Corporation Revision Date: May 1, 2017 Safety Data Sheet

SAFETY DATA SHEET According to Regulations (EC) No. 1272/2008 and (EU) No. 453/2010. IQ Starfiqs

Chlamydia Rapid Screen Test (RAP-2858) RUO in the USA. Revised 28 Jul 2006

Fryolux Tinning Compound

SAFETY DATA SHEET NEW AFTERCARE SHAMPOO 1000LITRE IBCNEWSHAM

May be harmful if inhaled. May cause respiratory tract irritation. Skin. May be harmful if absorbed through skin. May cause skin irritation.

OASIS PRO CITRUS GINGER ROOM REFRESHER. Use only for the purpose on the product label.

- Chemical characterisation / Description: Mixture of the substances listed below with harmless additions:

SECTION 1 PRODUCT AND COMPANY IDENTIFICATION

MATERIAL SAFETY DATA SHEET WILKINSONS GROUT CLEANER

Safety Data Sheet. Product Name: DetectX Palladium Screening Fluorescent Detection Kit. Section 1: Identification. Section 2: Hazard(s) Identification

Use only for the purpose on the product label.

Material Safety Data Sheet

SAFETY DATA SHEET - DISHWASHER LIQUID FOR SOFT WATER

MATERIAL SAFETY DATA SHEET. 1. Identification of the substance/preparation and of the company

Safety Data Sheet SECTION 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/26/2010 Print Date 08/26/2011

MATERIAL SAFETY DATA SHEET

Test kit contains HDL Cholesterol Precipitating Reagent and HDL Cholesterol Standard.

Safety Data Sheet. according to Regulation (EC) No 1907/2006. Coltosol F

Athens Research and Technology, Inc. SDS - SAFETY DATA SHEET

Pulpdent Corporation Revision Date: May 7, 2014

Blood Borne Pathogens (BBP)

HAV IgG/IgM Rapid Test

Rapid-VIDITEST. Influenza A

Product Identifier AWSD229: AIRWORKS AIR FRESHENER DISC FRUIT BASKET

Pulpdent Corporation Revision Date: January 1, 2014

Material Safety Data Sheet

Taking nose, throat and skin swabs. Clinical Skills

HDV Real-TM. Handbook

SAFETY DATA SHEET 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING

Bloodborne Pathogens For School Employees

SAFETY DATA SHEET. Section 1: Identification of the substance/mixture and of the company/undertaking

RealLine Mycoplasma genitalium Str-Format

MATERIAL SAFETY DATA SHEET

Bayer Environmental Science

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION. Material for temporary filling and rebuilding root canals

SAFETY DATA SHEET according to regulation (EC) No 1907/2006

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/28/2010 Print Date 07/08/2010

Material safety data sheet

Athens Research and Technology, Inc. SDS - SAFETY DATA SHEET

CitriBoost. Safety Data Sheet. Prepared according to Federal register / Vol. 77, No. 58/ Monday, March 26th 2012 / Rules and Regulations

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/28/2010 Print Date 08/29/2011

MATERIAL SAFETY DATA SHEET

To provide you with necessary knowledge and skills to accurately perform 3 HIV rapid tests and to determine HIV status.

SAFETY DATA SHEET according to regulation (EC) No 1907/2006

Transcription:

For in vitro diagnostic use cobas PCR Media Uni Swab Sample Kit P/N: 07958030190

Table of contents Intended use... 3 Reagents and materials... 4 cobas PCR Media Uni Swab Sample Kit... 4 Precautions and handling requirements... 5 Warnings and precautions... 5 Reagent handling... 5 Good laboratory practice... 5 Specimen collection... 6 Rectal swab specimen collection... 6 Throat swab specimen collection... 8 Vaginal swab specimen collection clinician collection... 10 Vaginal swab specimen collection self collection... 12 Specimen transport and storage... 13 Additional information... 14 Symbols... 14 Manufacturer and distributors... 15 Trademarks and patents... 15 Copyright... 15 References... 16 Document revision... 16 Doc Rev. 2.0 2

Intended use cobas PCR Media Uni Swab Sample Kit The cobas PCR Media Uni Swab Sample Kit is used to collect and transport human specimens. The cobas PCR Media serves as a nucleic acid stabilizing transport and storage medium for human specimens. Note: This kit has been validated for use with cobas CT/NG, and cobas Cdiff Tests. Refer to the assay-specific Instructions for Use for particular specimen claims. Doc Rev. 2.0 3

Reagents and materials cobas PCR Media Uni Swab Sample Kit All unopened kits shall be stored as recommended in Table 1. Table 1 cobas PCR Media Uni Swab Sample Kit cobas PCR Media Uni Swab Sample Kit Store at 15-30 C 100 Packets (P/N 07958030190) Packet components Reagent ingredients Quantity per packet Safety symbol and warning* cobas PCR Media 40% (w/w) Guanidine hydrochloride Tris-HCl buffer 1 x 4.3 ml Warning H302: Harmful if swallowed. H315: Causes skin irritation. Swab Envelope 1 woven swab (polyester bud) 1 swab Not applicable *Product safety labeling primarily follows EU GHS guidance H319: Causes serious eye irritation. P264: Wash skin thoroughly after handling. P270: Do not eat, drink or smoke when using this product. P280: Wear protective gloves/ eye protection/ face protection. P301 + P312 + P330: IF SWALLOWED: Call a POISON CENTER or doctor/ physician if you feel unwell. Rinse mouth. P337 + P313: If eye irritation persists: Get medical advice/ attention. P501: Dispose of contents/ container to an approved waste disposal plant. Doc Rev. 2.0 4

Precautions and handling requirements Warnings and precautions cobas PCR Media contains guanidine hydrochloride. Do not allow direct contact between guanidine hydrochloride and sodium hypochlorite (bleach) or other highly reactive reagents such as acids and bases. These mixtures can release a noxious gas. For in vitro diagnostic use only. Carefully follow the instructions, as shown below. Avoid contact of the cobas PCR Media with the skin, eyes or mucous membranes. If contact does occur, immediately wash with large amounts of water. If the collected specimen contains excess blood (specimen has a red or brown color), it should be discarded and not used for testing. Specimens should be handled as if infectious using safe laboratory procedures such as those outlined in Biosafety in Microbiological and Biomedical Laboratories 1 and in the CLSI Document M29-A4. 2 Safety Data Sheets (SDS) are available on request from your local Roche representative. Reagent handling If cobas PCR Media is spilled, FIRST clean with a suitable laboratory detergent and water, and then with 0.5% sodium hypochlorite. Dispose of unused reagents, waste and specimens in accordance with all applicable regulations. Do not use a kit after its expiration date. Ensure that the cap is tightened when closing the cobas PCR Media Tube. Do not pre-wet swab in cobas PCR Media before collection. Good laboratory practice Always follow Good Laboratory Practices/Good Clinical Practices (GLP/GCP). Wear protective disposable gloves, coats, and eye protection when handling specimens and kit reagents. Wash hands thoroughly after handling specimens and kit reagents. Doc Rev. 2.0 5

Specimen collection Rectal swab specimen collection WARNING: DO NOT PRE-WET SWAB IN cobas PCR MEDIA BEFORE COLLECTION! The cobas PCR Media Uni Swab Sample kit contains: cobas PCR Media Tube Woven Swab: A 1. COLLECT: To collect the specimen, hold the swab with the scoreline above your hand and insert the swab about 3 to 5 cm into the anal canal. Gently turn the swab for about 5-10 seconds while running the swab against the walls of the rectum. If the swab is grossly contaminated with feces, discard and repeat the collection. Withdraw the swab carefully. Do not let the swab touch any surface before placing it into the collection tube. Doc Rev. 2.0 6

2. ALIGN: Remove the cap from the cobas PCR Media Tube ad lower the swab specimen into the tube until the visible scoreline on the swab is aligned with the tube rim. The tip of the swab should not be submerged into the liquid prior to breaking the shaft. 3. BREAK: Carefully leverage the swab against the tube rim to break the swab shaft at the scoreline. 4. CLOSE: Tightly re-cap the cobas PCR Media Tube. The specimen is now ready for transport. Discard the top portion of the swab. Specimen transport and storage Following specimen collection, transport and store the cobas PCR Media Tube containing the collection swab at 2 C to 30 C. Consult the test-specific Instructions for Use for collected specimen stability claims. Transportation of collected specimens must comply with all applicable regulations for the transport of etiologic agents. 3 Doc Rev. 2.0 7

Throat swab specimen collection cobas PCR Media Uni Swab Sample Kit WARNING: DO NOT PRE-WET SWAB IN cobas PCR MEDIA BEFORE COLLECTION! The cobas PCR Media Uni Swab Sample kit contains: cobas PCR Media Tube Woven Swab: A 1. COLLECT: To collect the specimen, hold the swab with the scoreline above your hand and insert the swab into the mouth and collect the specimen from the bilaterial posterior pharynx, both tonsils and the uvula. Withdraw the swab carefully. Do not let the swab touch any surface before placing it into the collection tube. Doc Rev. 2.0 8

2. ALIGN: Remove the cap from the cobas PCR Media Tube ad lower the swab specimen into the tube until the visible scoreline on the swab is aligned with the tube rim. The tip of the swab should not be submerged into the liquid prior to breaking the shaft. 3. BREAK: Carefully leverage the swab against the tube rim to break the swab shaft at the scoreline. 4. CLOSE: Tightly re-cap the cobas PCR Media Tube. The specimen is now ready for transport. Discard the top portion of the swab. Specimen transport and storage Following specimen collection, transport and store the cobas PCR Media Tube containing the collection swab at 2 C to 30 C. Consult the test-specific Instructions for Use for collected specimen stability claims. Transportation of collected specimens must comply with all applicable regulations for the transport of etiologic agents. 3 Doc Rev. 2.0 9

Vaginal swab specimen collection clinician collection cobas PCR Media Uni Swab Sample Kit WARNING: DO NOT PRE-WET SWAB IN cobas PCR MEDIA BEFORE COLLECTION! The cobas PCR Media Uni Swab Sample kit contains: cobas PCR Media Tube Woven Swab: A 1. COLLECT: In one hand, hold the swab with the scoreline above your hand and insert the swab about 5 cm (2 inches) into the vaginal opening. Gently turn the swab for about 30 seconds while rubbing the swab against the walls of the vagina. Withdraw the swab carefully. Do not let the swab touch any surface before placing it into the collection tube. Doc Rev. 2.0 10

2. ALIGN: Remove the cap from the cobas PCR Media Tube and lower the swab specimen into the tube until the visible scoreline on the swab is aligned with the tube rim. The tip of the swab should not be submerged into the liquid prior to breaking the shaft. 3. BREAK: Carefully leverage the swab against the tube rim to break the swab shaft at the scoreline. 4. CLOSE: Tightly re-cap the cobas PCR Media Tube. The specimen is now ready for transport. Discard the top portion of the swab. Specimen transport and storage Following specimen collection, transport and store the cobas PCR Media Tube containing the collection swab at 2 C to 30 C. Consult the test-specific Instructions for Use for collected specimen stability claims. Transportation of collected specimens must comply with all applicable regulations for the transport of etiologic agents. 3 Doc Rev. 2.0 11

Vaginal swab specimen collection self collection cobas PCR Media Uni Swab Sample Kit WARNING: DO NOT PRE-WET SWAB IN cobas PCR MEDIA BEFORE COLLECTION! The cobas PCR Media Uni Swab Sample kit contains: cobas PCR Media tube Woven Swab: A 1. POSITION: In one hand, hold the swab with the scoreline above your hand and with the other hand separate the folds of skin around the vaginal opening (labia). Doc Rev. 2.0 12

2. COLLECT: Insert the swab about 5cm (2 inches) into the vaginal opening. Gently turn the swab for about 30 seconds while rubbing the swab against the wall of the vagina. Remove the swab carefully. Do NOT touch the swab to any surface before placing into the collection tube. 3. OPEN TUBE: While holding the swab in the same hand, remove the cap from the tube as shown above. 4. ALIGN: Lower the swab into the tube until the visible scoreline on the shaft is lined up with the tube rim. 5. BREAK: Carefully lean the swab against the tube rim to break the swab shaft at the scoreline. 6. CLOSE: Tightly close the cobas PCR Media Tube. Return the sample to your healthcare provider as instructed. Discard the top portion of the swab. Specimen transport and storage Following specimen collection, transport and store the cobas PCR Media Tube containing the collection swab at 2 C to 30 C. Consult the test-specific Instructions for Use for collected specimen stability claims. Transportation of collected specimens must comply with all applicable regulations for the transport of etiologic agents. 3 Doc Rev. 2.0 13

Additional information Symbols The following symbols are used in labeling for Roche PCR diagnostic products. Age or Date of Birth Do not reuse Authorized Representative in the European community Batch code Female In Vitro Diagnostic Medical Device Catalogue number Male Collect date Manufacturer Consult instructions for use Non sterile Contains sufficient for <n> tests Patient ID Contents of kit Patient Name Distributed by Peel here Site Urine Fill Line Sterilized using ethylene oxide Use-by date Temperature Limit Global Trade Item Number This product fulfills the requirements of the European Directive 98/79 EC for in vitro diagnostic medical devices. US Customer Technical Support 1-800-526-1247 Doc Rev. 2.0 14

Manufacturer and distributors Manufactured for: Roche Molecular Systems, Inc. 1080 US Highway 202 South Branchburg, NJ 08876 USA www.roche.com Roche Diagnostics Roche Diagnostics, SL 201, boulevard Armand-Frappier Avda. Generalitat, 171-173 H7V 4A2 Laval, Québec, Canada E-08174 Sant Cugat del Vallès (For Technical Assistance call: Barcelona, Spain Pour toute assistance technique, appeler le: 1-877-273-3433) Distribuidor em Portugal: Roche Sistemas de Diagnósticos Lda. Distributore in Italia: Estrada Nacional, 249-1 Roche Diagnostics S.p.A 2720-413 Amadora, Portugal Viale G. B. Stucchi 110 20052 Monza, Milano, Italy Roche Diagnostics 2, Avenue du Vercors Roche Diagnostics GmbH 38240 Meylan, France Sandhofer Strasse 116 68305 Mannheim, Germany Roche Diagnostica Brasil Ltda Av. Engenheiro Billings, 1729 Roche Diagnostics (Schweiz) AG Jaguaré, Building 10 Industriestrasse 7 05321-010 São Paulo, SP Brazil 6343 Rotkreuz, Switzerland Trademarks and patents See http://www.roche-diagnostics.us/patents Copyright 2017 Roche Molecular Systems, Inc. Doc Rev. 2.0 15

References 1. Center for Disease Control and Prevention. Biosafety in Microbiological and Biomedical Laboratories, 5th ed. U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institutes of Health HHS Publication No. (CDC) 21-1112, revised December 2009. 2. Clinical and Laboratory Standards Institute (CLSI). Protection of laboratory workers from occupationally acquired infections. Approved Guideline-Fourth Edition. CLSI Document M29-A4:Wayne, PA;CLSI, 2014. 3. International Air Transport Association. Dangerous Goods Regulations, 52nd Edition. 2011. Document revision Document Revision Information Doc Rev. 1.0 10/2016 Doc Rev. 2.0 04/2017 First Publishing. Added statement Refer to the assay-specific Instructions for Use for particular specimen claims and removed reference to cobas CT/NG v2.0 Test in the Intended use section. Please contact your local Roche Representative if you have any questions. Doc Rev. 2.0 16