Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Similar documents
Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

Small Field Dosimetry: Overview of AAPM TG-155 and the IAEA-AAPM Code of Practice (Therapy)

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

SRS Uncertainty: Linac and CyberKnife Uncertainties

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Credentialing for the Use of IGRT in Clinical Trials

SBRT of Lung & Liver lesions using Novalis IGRT System. Patrick Silgen, M.S., DABR Park Nicollet Methodist Hospital

Image Guided Stereotactic Radiotherapy of the Lung

SBRT TREATMENT PLANNING: TIPS + TRICKS. Rachel A. Hackett CMD, RT(T)

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Work partially supported by VisionRT

In-Room Radiographic Imaging for Localization

Flattening Filter Free beam

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Special Procedures Rotation I/II SBRT, SRS, TBI, and TSET

Implementing SBRT Protocols: A NRG CIRO Perspective. Ying Xiao, Ph.D. What is NRG Oncology?

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Treatment Planning for Lung. Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

Cyberknife Stereotactic Treatment

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies

Technique For Plan Quality and Efficiency Using VMAT Radiosurgery For Patients with Multiple Brain Metastases

In-Room Radiographic Imaging for Localization

Treatment Planning & IGRT Credentialing for NRG SBRT Trials

8/3/2016. Outline. Site Specific IGRT Considerations for Clinical Imaging Protocols. Krishni Wijesooriya, PhD University of Virginia

Stereotactic Radiosurgery. Extracranial Stereotactic Radiosurgery. Linear accelerators. Basic technique. Indications of SRS

Image Registration for Radiation Therapy Applications: Part 2: In-room Volumetric Imaging

EORTC Member Facility Questionnaire

Original Date: April 2016 Page 1 of 7 FOR CMS (MEDICARE) MEMBERS ONLY

Image Fusion, Contouring, and Margins in SRS

brain SPINE 2 SRS Matures into breast lung spine LUNG Dr. Robert Timmerman Discusses SBRT for Inoperable Lung Cancer BRAIN

SBRT in early stage NSCLC

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

Stereotactic radiotherapy

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

Pitfalls in SBRT Treatment Planning for a Moving Target

Introduction. Modalities used in imaging guidance. Flat panel detector. X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

The role of Radiation Oncologist: Hi-tech treatments for liver metastases

SRS Plan Quality and Treatment Efficiency: VMAT vs Dynamic Conformal ARCs

Which Planning CT Should be Used for Lung SBRT? Ping Xia, Ph.D. Head of Medical Physics in Radiation Oncology Cleveland Clinic

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

Disclosures. Overview 8/3/2016. SRS: Cranial and Spine

EXACTRAC HIGHLY ACCURATE PATIENT MONITORING

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

8/2/2018. Disclosures. In ICRU91: SRT = {SBRT/SABR, SRS}

The TomoTherapy System as a Tool of Differentiation in Quality and Marketability

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Unrivaled, End-to-End

Image Guided in Radiation Therapy (IGRT) Chumpot Kakanaporn Med Phys Radiation Oncology Siriraj Hospital

Stereotactic Body Radiotherapy for Lung Tumours. Dr. Kaustav Talapatra Head, Radiation Oncology Kokilaben Dhirubhai Ambani Hospital Mumbai

Clinical Implementation of SRS/SBRT

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

Radiation treatment planning in lung cancer

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

Comparison of Interfacility Implementation of Essential SBRT Components. Keith Neiderer B.S. CMD RT(T) VCU Health System

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Potential systematic uncertainties in IGRT when FBCT reference images are used for pancreatic tumors

4D Radiotherapy in early ca Lung. Prof. Manoj Gupta Dept of Radiotherapy & oncology I.G.Medical College Shimla

On the use of 4DCT derived composite CT images in treatment planning of SBRT for lung tumors

Advances in external beam radiotherapy

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

Learning objective. Outline. Acknowledgements. KV CBCT Imaging Part I. R Hammoud AAPM 2008 CE-Therapy (SAM) 1

Proton Stereotactic Radiotherapy: Clinical Overview. Brian Winey, Ph.D. Physicist, MGH Assistant Professor, HMS

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

ph fax

Overview of MLC-based Linac Radiosurgery

3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients

Results of Stereotactic radiotherapy for Stage I and II NSCLC Is There a Need for Image Guidance?

Defining Target Volumes and Organs at Risk: a common language

Small Field Dosimetry: An Overview of Reference and Relative Dosimetry in Non-Equilibrium Condition

Overview of Advanced Techniques in Radiation Therapy

Subject: Image-Guided Radiation Therapy

PGY-1. Resident Review Session Schedule

Case Study. Institution Farrer Park Hospital

Medical Dosimetry Graduate Certificate Program IU Graduate School & The Department of Radiation Oncology IU Simon Cancer Center

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies USE OF STEREOTACTIC BODY RADIATION THERAPY FOR INOPERABLE NON- SMALL CELL LUNG TUMORS

Implementation of advanced RT Techniques

Managing the imaging dose during image-guided radiation therapy

Many vendors are beginning to allow couch motion during radiation delivery.

ADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER

8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

1 : : Medical Physics, Città della Salute e della Scienza, Torino, Italy

SunCHECK Patient Comprehensive Patient QA

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

Jean Pouliot, PhD Professor and Vice Chair, Department of Radiation Oncology, Director of Physics Division

IMRT FOR CRANIOSPINAL IRRADIATION: CHALLENGES AND RESULTS. A. Miller, L. Kasulaitytė Institute of Oncolygy, Vilnius University

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Protocol of Radiotherapy for Small Cell Lung Cancer

SBRT REQUIRES: STEREOTACTIC BODY RADIOTHERAPY STEREOTACTIC BODY RADIOTHERAPY (SBRT) (SBRT) What s s in a name? Stereotactic Body Radiotherapy

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Margins in SBRT. Mischa Hoogeman

Transcription:

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR PhD, FAAPM, FACR, FASTRO Department of Radiation Oncology Indiana University School of Medicine Indianapolis, IN, USA Indra J. Das, PhD, FAAPM, FACR, FASTRO

Stereotactic RadioSurgery Cranial (Head & Brain) (SRS, SRT) Extra Cranial (lung, liver, pancreas, spine, prostate); (SBRT) Cranial Extra-Cranial Lung Liver Spine

Conventional RT vs SBRT Characteristic Conventional RT SBRT Dose / Fraction 1.8 3 Gy 6 30 Gy No. of Fractions 10 45 1-5 Treatment time 10-15 min Up to 45min Planning Margin cm mm Imaging modalities used for Tx planning CT Multi-modality: CT/MR/PET-CT Geometric verification Anatomy Stereotactic system Staff Training Highest Highest + special SBRT Training Physics / dosimetry monitoring Indirect Direct

Systems for SBRT Linear Accelerator Based SBRT Rapid Arc True Beam Body Frame with linear accelerator Elekta Varian Pro-Lock System Dedicated Delivery Systems Gamma Knife Novalis, Brain Lab Tomotherapy Cyber-Knife Proton beam

Delivery Systems Linear Accelerator Novalis Radiosurgery Cyber Knife Tomotherapy Gamma Knife Proton Beam

BrainLab Novalis, SRS/SRT/IMRS m3 μmlc Novalis Head rings BrainLab Cone: 4mm-20mm diameter

Cyber Knife Based SRS Robotic treatment IGRT Intra-treatment imaging Orthogonal kv imaging Cone Size from 5 mm to 60 mm

Proton Beam SRS/SBRT Cyclotron Synchrotron Treatment Schematic Harvard/MGH SRS system

Dose Distributions (Liver SBRT)

Dose Distributions (Lung SBRT) 3DCRT or IMRT

Dose Distributions Spine SBRT

Recurrent-Spine SBRT

SBRT at Indiana University A phase I trial of SBRT for medically inoperable lung cancer was initiated at Indiana University in the late 1990s By Dr Timmerman Currently SBRT at Indiana University Lung (primary and metastases) Liver (primary Hepatocellular Carcinoma HCC and metastases) Majority of our patients have been treated utilizing the Elekta Stereotactic Body Frame System Fakiris et al.. Stereotactic body radiation therapy for early stage non-small small-call lung carcinoma: four-year results of a prospective phase II study. Int. J. Radiat. Oncol. Biol. Phys. V75(3), p677-682, 682, 2009 Cardenes et al. Phase I feasibility trail of stereotactic body radiation therapy for primary hepatocellular carcinoma, Cin Transl Oncol V12(3), p218-24. 2010

SBRT High dose of radiation delivered in a hypofractionated regimen (single fraction or 3-5 fractions) High target accuracy Stereotactic reference - target is localized relative to a known 3D coordinate system through the use of external fiducial markers Patient immobilization is important Rapid dose falloff (sharp dose gradient) Multiple conformal beams

Elekta Stereotactic Body Frame 8 4 6 X Y 3 7 Z 1 2 5

Different Systems Elekta Stereotactic body frame CIVCO Body Pro-Lok system Small box frame system tightly restricts patient motion Modular structures highly adaptable to individual patient Stereotactic reference system to localize target Isocenter setup relies on skin marks/tattoos Can not be indexed to treatment couch Respiration compression plate Indexed to treatment couch Respiration compression plate and belt

CT Simulation Planning CT obtained from CT-Simulator 2 mm axial slice through area of interest 4D-CT obtained for motion assessment Fusion Image obtained with patient in frame Positron Emission Tomography PET (lung and liver) Dual phase CT (liver)

Multi Modality Imaging CT PET Regular CT Dual phase CT Erdi et. al. Radiotherapy and Oncology 62 (2002) 51-60

4D-CT Spatial X, Y, Z + Temporal => 4D CT Raw Data/ Images Respiration Signal CT Acquisition Software

Motion Assessment 4DCT

Treatment Planning Contour volumes Beam placement and beam modifiers Plan evaluation Isocenter stereotactic coordinate determination Coordinate verification QA

Treatment Planning Structure Contour Structure contoured based on RTOG protocols or internal guidelines LUNG GTV use lung window Spinal Cord Whole lung Esophagus Heart Proximal Bronchial Tree Trachea Brachial plexus, ipsilateral Descending aorta (optional) Chestwall/ Rib Skin LIVER GTV Spinal cord Whole liver Stomach / Duodenum Heart Rt and Lt Kidneys Small Bowel Rt Lung Bowel Chestwall/ Rib Skin PTV is created per protocol (normally 0.5cm axial margin and 1cm superior-inferior margin around GTV)

Possible Beam Arrangements

SBRT, Lung Photon Proton

CyberKnife Plans

Plan Evaluation Target coverage Target dose heterogeneity Normal tissue constraints Conformity indices High dose spillage Low dose spillage RTOG 0236 AAPM TG-101 Timmerman R. Semin. Radiat. Oncol. 18: p215-222. 2008

Treatment Planning Isocenter Coordinates X iso = X measure + 85 Y iso = Y meaasure Z iso = Z meaasure +n x 100

Treatment Day Patient setup in frame according to simulation parameters Isocenter setup by stereotactic reference system Image acquisition and treatment verification Online correction through couch adjustment Treat

Image Guided Treatment Verification Purpose: to verify patient position on the treatment day is the same as the planned and to provide correction guidance if deviation is discovered IGRT systems Fixed or rotating kv and MV imagers (2D imaging) 3D volumetric imaging

Cone Beam CT - Lung Tumor Match Before Registration (CBCT and Planning CT blended) After Registration (CBCT and Planning CT blended)

Cone Beam CT - Liver Tissue Match Before Registration (CBCT and Planning CT blended) After Registration (CBCT and Planning CT blended)

Cone Beam CT Bony Anatomy Verify Before Registration (CBCT and Planning CT blended) After Registration (CBCT and Planning CT blended)

Comparison between 2 systems Compared with Elekta body frame, the Pro-lok system is relatively complex and time consuming in patient simulation and treatment setup Relatively larger random setup errors were found in Pro-lok system for both SBRT liver and lung treatment setup Large inter-fractional correction occurs more frequently with Pro-lok system Image guidance is critical for SBRT patient setup, especially when Pro-lok system is used

Histograms of inter-fractional couch corrections of liver patient setup Pro-Lok System Elekta System 25 20 Vrt Lng Lat 40 35 30 Vrt Lng Lat frequency [%] 15 10 frequency [%] 25 20 15 5 10 5 0 0 0.2 0.4 0.6 0.8 1 couch correction [cm] 0 0 0.2 0.4 0.6 0.8 1 couch correction [cm] For large couch corrections, repeated CBCTs are often performed to verify the correction. For Pro-lok system, 40.7% of all the fractions ended up with repeated CBCT. Only 13.6% of fractions have repeated CBCT when Elekta body frame was used

Results of Two Systems Systematic Setup Error Random Setup Error 0.8 0.6 ProLok Elekta 0.7 0.6 ProLok Elekta Liver Systematic error (cm) 0.4 0.2 0.0-0.2-0.4 Vrt Lng Lat Random error (cm) 0.5 0.4 0.3 0.2 0.1 0-0.6 Vrt Lng Lat Lung Systematic error (cm) 0.8 0.6 0.4 0.2 0.0-0.2 ProLok Elekta Vrt Lng Lat Random error (cm) 0.6 0.5 0.4 0.3 0.2 0.1 ProLok Elekta -0.4 0-0.6 Vrt Lng Lat

Linac vs CyberKnife Linac Cyber Knife Lung Liver ing et al, Med Phys, 40(5), 051705, 2013

PTV Prescription Gamma Knife 50% CyberKnife 50-70% Lung (40-48% ) Ding et al, 2013 Liver (67-77%) Ding et al, 2013 Novalis 70-80% Accelerator 80% 3DCRT 95-100% IMRT 100%

Small Field Dosimetry f D M w, Q f Q N DW, Qo k Q, Qo k f Q, f, Q ref f Q clin clin f Q M M f Q f Q clin clin f clin fclin Dw, Q M clin Qclin f f D / M w, Q fclin / M Qclin fclin, f Q M f Q k Q clin, Q k f Q clin clin f fclin Dw, Q / M Q ( Output) clin w, clin rel f f D / M clin clin (Re ading ) rel, f, Q w, Q w, Q k f Q clin clin, f, Q ( S ( S w, air w, air ) ) fclin f P P fclin

Why So Much of Fuss? Reference (ref) conditions cannot be achieved for most SRS devices (cyberknife, gammaknife, tomotherapy etc) Machine Specific reference () needs to be linked to ref Ratio of reading (PDD, TMR, Output etc) is not the same as ratio of dose D1 D 2 M M D 1 M1 fclin, f k Q clin, Q D2 M 2 1 2

Impact of k f Q clin clin, f, Q Relative dose at d max Field Size (cm)

What is Common Theme? Multimodality imaging for target delineation Very High dose (20-60 Gy) in few fractions (1-5) Stereotactic immobilization / CBCT/ image based High degree of precision (mm) needed Small Fields High degree of precision in dosimetry needed Accurate commissioning data Proper selection of detector Repeated imaging for localization, pretreatment and during treatment

Selection of a SBRT Machine Hard to compare Advertising for personal gain Only anecdotal and dosimetric data No scientific data on clinical outcome No randomization possible in this era

Summary SRS/SRT/SBRT/IMRS is now widely used for hypofractionated treatment world wide with good outcome Image guidance for treatment planning and treatment verification is very critical to the success of SBRT radiation therapy Quality assurance and Small Field dosimetry as well as continuous monitoring of the QA and process is critical For SBRT, image-guided localization techniques shall be used to guarantee the spatial accuracy of the derived dose distribution AAPM has Task Group report on every modalities that can be referred There is no superiority of any device that can be recommended