Low-dose and High-resolution Cardiac Imaging with Revolution CT

Similar documents
Combined Anatomical and Functional Imaging with Revolution * CT

BrightSpeed Elite CT with ASiR: Comparing Dose & Image Quality Rule Out Pulmonary Embolism on Initial & Follow-Up Exam

Cardiac CT Lowering the Dose Dramatically

Gemstone Spectral Imaging quantifies lesion characteristics for a confident diagnosis

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

Disclosure Information

PINPOINTING RADIATION THERAPY WITH THE PRECISION OF MR.

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

CT Myocardial Perfusion: Is there Added Value to Coronary CT?

The radiation dose in retrospective

GE Healthcare. Look differently. Invenia ABUS. Automated Breast Ultrasound

Dual Energy CT of the Heart: Perfusion and Beyond

Is computed tomography angiography really useful in. of coronary artery disease?

Use of Nuclear Cardiology in Myocardial Viability Assessment and Introduction to PET and PET/CT for Advanced Users

MEDICAL UNIVERSITY of SOUTH CAROLINA

Correlation of Cardiac CTA to Conventional Cardiac Angiography in Diagnosing Coronary Artery Stenosis in a Community Based Center

SPECT-CT: Τι πρέπει να γνωρίζει ο Καρδιολόγος

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

CT Perfusion. U. Joseph Schoepf, MD, FAHA, FSCBT MR, FSCCT Professor of Radiology, Medicine, and Pediatrics Director of Cardiovascular Imaging

Alessandro Albonico Philips

Low-Dose Computed Tomography Coronary Angiography With Prospective Electrocardiogram Triggering

Vivid T8 Ultrasound. Cardiac and shared services. Together like never before from GE.

GE Healthcare 9900 Innovation Drive Wauwatosa, WI U.S.A.

Low Dose Era in Cardiac CT

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre

How do the Parameters affect Image Quality and Dose for Abdominal CT? Image Review

CASE from South Korea

Certainty. lives in layers. Philips IQon Spectral CT. Computed tomography

Stress only Perfusion Imaging

AFib is the most common cardiac arrhythmia and its prevalence and incidence increases with age (Fuster V. et al. Circulation 2006).

Cardiac Imaging Tests

Simon Nepveu 1, Irina Boldeanu 1, Yves Provost 1, Jean Chalaoui 1, Louis-Mathieu Stevens 2,3, Nicolas Noiseux 2,3, Carl Chartrand-Lefebvre 1,3

Imaging ischemic heart disease: role of SPECT and PET. Focus on Patients with Known CAD

I have no financial disclosures

Conflict of Interest Disclosure

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Impact of SSF on diagnostic performance of coronary CT angiography within one heart beat in patients with high heart rate using a 256-row detector CT

Radiation Dose Reduction Strategies in Coronary CT Angiography

Disclosures. GETTING TO THE HEART OF THE MATTER WITH MULTIMODALITY CARDIAC IMAGING Organ Review Meeting 25 September. Overview

SYNTAX III REVOLUTION Trial Press briefing conference. Prof. Patrick W. Serruys MD, PhD Principal Investigator Imperial College of London

Vivid T8 Ultrasound. Cardiac and shared services. Together like never before from GE. Take rugged reliability to challenging conditions.

Technology Assessment Institute: Summit on CT Dose Cardiac CT - Optimal Use of Evolving Scanner Technologies

Coronary Artery Anomalies from Birth to Adulthood; the Role of CT Coronary Angiography in Sudden Cardiac Death Screening

Isolated congenital coronary anomalies: Evaluation by multislice-ct or MRI

Index. radiologic.theclinics.com. Note: Page numbers of article titles are in boldface type.

Clinical Image Gallery Next Generation Volume 1

IOWA RADIOLOGY 1. Guide to CT Scans Clive Downtown Des Moines

A new method for radiation dose reduction at cardiac CT with multi-phase data-averaging and non-rigid image registration: preliminary clinical trial

Les Outils Cliniques de Demain en Scanner Cardiaque. Cardiaque Status en ECR 2018 From Diagnosis to Prognosis

Vivid S6. Cardiovascular ultrasound system. GE Healthcare. Davis Medical

Potential recommendations for CT coronary angiography in athletes

The Emerging Role of Cardiac CT in Cardiovascular Imaging. Anthony Gemignani, MD Vermont Cardiac Network April 28, 2016

Proteus XR/f Patient positioning guide

Computer Aided Detection and Diagnosis: Cardiac Imaging Applications

General Cardiovascular Magnetic Resonance Imaging

Multisclice CT in combination with functional imaging for CAD. Temporal Resolution. Spatial Resolution. Temporal resolution = ½ of the rotation time

Dr Felix Keng. Imaging of the heart is technically difficult because: Role of Cardiac MSCT. Current: Cardiac Motion Respiratory Motion

CT Myocardial Perfusion

Calcium Scoring and Cardiac CT

Cardiac CT Angiography

Advanced Imaging MRI and CTA

Optimal testing for coronary artery disease in symptomatic and asymptomatic patients

Computed Tomography of the Coronary Arteries

Contrast-Enhanced Computed Tomography Angiography (CTA) for Coronary Artery Evaluation

Cardiac Computed Tomography

Stable Angina: Indication for revascularization and best medical therapy

Cardiac CTA Prospective Gating Broad Beam

MICHIGAN CORONARY CTA PRIOR-AUTHORIZATION INFORMATIONAL GUIDE

A comparison of radiation doses from modern multi-slice Computed Tomography angiography and conventional diagnostic Angiography:

Typical PET Image. Elevated uptake of FDG (related to metabolism) Lung cancer example: But where exactly is it located?

b. To facilitate the management decision of a patient with an equivocal stress test.

Kavitha Yaddanapudi Stony brook University New York

Hospital, 6 Lukon Road, Lukong Town, Changhua Shien, Taiwan 505, Taiwan.

Nuclear Cardiology Cardiac Myocardial Perfusion with 82 Rb. Dominique Delbeke, MD, PhD Vanderbilt University Medical Center Nashville, TN

Validation of CT Perfusion Imaging Against Invasive Angiography and FFR on a 320-MDCT Scanner

Lung Perfusion Analysis New Pathways in Lung Imaging. Case Study Brochure PLA 309 Hospital

LOGIQ V2. Simple. Fast. Precise. Empowering Point of Care Medicine.

High Speed Myocardial Perfusion SPECT: Validation of Quantitative Analysis and use in Low Dose Stress only Protocol

Which Test When? Avoid the Stress of Stress Testing. Marc Newell, MD, FACC, FSCCT Minneapolis Heart Institute

Cardiac CT saves money and time as first-line heart test 4/1/2008

New Technologies for Cardiac CT. Geoffrey D. Rubin, MD, MBA, FACR, FNASCI Duke University

CT or PET/CT for coronary artery disease

Why is CT Dose of Interest?

Hybrid cardiac imaging Advantages, limitations, clinical scenarios and perspectives for the future

Assignable revenue codes: Explanation of services:

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

, David Stultz, MD. Cardiac CT. David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006

J. Schwitter, MD, FESC Section of Cardiology

(Non-EKG Gated) CTA Thoracic Aorta = CTA Chest

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

Cigna - Prior Authorization Procedure List: Radiology & Cardiology

Usefulness of New CT Technologies for Interventional Cardiovascular Procedures

Pearls & Pitfalls in nuclear cardiology

ADVANCED CARDIOVASCULAR IMAGING. Medical Knowledge. Goals and Objectives PF EF MF LF Aspirational

A Snapshot on Nuclear Cardiac Imaging

Cardiac Nuclear Medicine

CHRONIC CAD DIAGNOSIS

Assignable revenue codes: Explanation of services:

Evidence for Everyone: Expanding the Reach of Health Technology Assessment 2016 CADTH Symposium, April 10-12, Shaw Centre, Ottawa

Transcription:

GE Healthcare Case study Low-dose and High-resolution Cardiac Imaging with Revolution CT Prof. Philipp A. Kaufmann, M.D. Ronny R. Buechel, M.D. Fran Mikulicic, M.D. Dominik C. Benz, M.D. University of Zürich, Department of Nuclear Medicine, Switzerland

Case 1 Detailed and Reliable Stenosis Detection in One Heart Beat A man in his 60s complaining of typical angina pectoris and status after TIA was referred to coronary CT angiography after an exercise test clinically positive and electrically negative. - 160 mm axial scanning with - 100 kv and 270 ma - 75% acquisition peak - BMI: 25 - ASiR-V 1 to lower dose Curved - LAD 3D Coronary Tree SPECT Hybrid Coronary angiogram - 0.28 sec rotation speed - Heart rate: 46-48 BPM - DLP 45 mgy-cm - 0.63 msv2 - Exposure time: 0.28 sec In this patient with a calcium score of 0, a subtotal occlusion of the LAD (90-99 %) could be visualized on the CT images. Thanks to the one-beat axial acquisition, the new iterative reconstruction technology ASiR-V and the high image quality at low kv, Revolution CT delivers cardiac CT with excellent soft plaque differentiation at very low dose in routine use. Dr. Ronny R. Buechel Correspondingly, SPECT revealed a large reversible perfusion defect in the anterior wall. The patient underwent coronary angiogram where the diagnosis was confirmed and stenting of the lesion was performed.

Case 2 Rapid Exclusion of CAD with Ultra-low-dose CCTA A woman in her 60s, with no cardiovacular risk factors, but complaining of exercise dependent, atypical chest pain was referred to coronary CT angiography after an exercise test clinically positive and electrically negative. - 160 mm axial scanning with -8 0 kv and 180 ma -B MI: 17 - ASiR-V1 to lower dose -0.28 sec rotation speed -H eart rate: 56 BPM - 40 cc of contrast media (320 mg I/ml) including SmartPrep phase triggering - DLP 14 mgy-cm - 0.19 msv2 - Exposure time: 0.28 sec Thanks to the 160 mm coverage and ASIR-V the exam was performed with ultra-low dose and very low iodine load to exclude CAD. On the first 100 cardiac CT exams that we performed, we achieved an average dose of 0.5 msv, thanks to the one-beat axial acquisition, the new iterative reconstruction technology ASiR-V and the high image quality at low kv. Prof. Dr. Philipp A. Kaufmann

Case 3 Congenital Anomalous Course of Left Coronary Artery A man in his 40s with elevated coronary risk profile and atypical chest pain was referred to CT for risk stratification. - 160 mm axial scanning with - 100 kv and 256 ma - BMI: 26 - ASiR-V 1 to lower dose - 0.28 sec rotation speed - Heart rate: 69-72 BPM - DLP 37 mgy-cm - 0.52 msv 2 - Exposure time: 0.28 sec Thanks to the one-beat cardiac acquisition and ASIR-V, a confident and reproducible diagnosis of coronary arteries can be performed with very low dose, even at high heart rates. Dr. Fran Mikulicic This congenital anomaly of the left coronary artery reveals a joint origin of the LMA and RCA from the right coronary cusp with interarterial course of the left main artery. This rare anomaly is associated with sudden cardiac death particularly during strenuous exercise. For further evaluation a myocardial SPECT with exercise stress testing is planned to evaluate the relevance of the finding in this particular case.

About GE Healthcare GE Healthcare provides transformational medical technologies and services to meet the demand for increased access, enhanced quality and more affordable healthcare around the world. GE (NYSE: GE) works on things that matter - great people and technologies taking on tough challenges. From medical imaging, software & IT, patient monitoring and diagnostics to drug discovery, biopharmaceutical manufacturing technologies and performance improvement solutions, GE Healthcare helps medical professionals deliver great healthcare to their patients. GE Healthcare 3000 N. Grandview Blvd. Waukesha, WI 53188 USA gehealthcare.com @GEHealthcare GE imagination at work 2015 General Electric Company All rights reserved. General Electric Company reserves the right to make changes in specification and features shown herein, or discontinue the product described at any time without notice or obligation. GE, the GE mongram, Revolution and ASiR-V are trademarks of General Electric Company. GE Healthcare, a division of General Electric Company. The clinical cases are displayed for educational purposes only and for the benefit of healthcare students and professionals. 1 In clinical practice, the use of ASiR-V may reduce CT patient dose depending on the clinical task, patient size, anatomical location and clinical practice. A consultation with a radiologist and a physicist should be made to determine the appropriate dose to obtain diagnostic image quality for the particular clinical task. 2 Obtained using a chest factor of 0.014*DLP Legal Mentions : The system is intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission projection data from the same axial plane taken at different angles. The system has the capability to image whole organs in a single rotation. Whole organs include but are not limited to brain, heart, liver, kidney, pancreas, etc.. The system may acquire data using Axial, Cine, Helical, Cardiac, and Gated CT scan techniques from patients of all ages. These images may be obtained either with or without contrast. This device may include signal analysis and display equipment, patient and equipment supports, components and accessories. Class: IIb Manufacturer: GE Medical Systems LLC, USA LNE/G-MED NB 0459 GMDN 37618. JB28027XE