Modified candy-plug technique for chronic type B aortic dissection with aneurysmal dilatation: a case report

Similar documents
Distal False Lumen Occlusion in Aortic Dissection With a Homemade Extra-Large Vascular Plug: The Candy-Plug Technique

Modification in aortic arch replacement surgery

Acute dissections of the descending thoracic aorta (Debakey

What is the best treatment for False Lumen growth after type B Dissection

Residual Dissection and False Lumen Aneurysm After TEVAR

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

The Petticoat Technique Managing Type B Dissection with both Early and Long Term Considerations

Endovascular therapy for Ischemic versus Nonischemic complicated acute type B aortic dissection (catbad).

Abdominal and thoracic aneurysm repair

Challenges. 1. Sizing. 2. Proximal landing zone 3. Distal landing zone 4. Access vessels 5. Spinal cord ischemia 6. Endoleak

Indications for use. Contraindications within the United States

Pioneering EVAR techniques in aortic dissection

Hybrid Repair of a Complex Thoracoabdominal Aortic Aneurysm

Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui

No Disclosure. Aortic Dissection in Japan. This. The Challenge of Acute and Chronic Type B Aortic Dissections with Endovascular Aortic Repair

Optimal Treatment of Chronic Dissection

Objective assessment of current stent grafts: which graft for which lesion. Ludovic Canaud, MD, PhD Pierre Alric, MD, PhD Montpellier, France

Ascending Aorta: Is The Endovascular Approach Realistic?

I-Hui Wu, M.D. Ph.D. Clinical Assistant Professor Cardiovascular Surgical Department National Taiwan University Hospital

Development of Stent Graft. Kato et al. Development of an expandable intra-aortic prothesis for experimental aortic dissection.

Is it time to stent the ascending aorta? Martin Czerny

Vascular Intervention

Title. Different arch branched devices are available, is morphology the. main criteria of choice? Ciro Ferrer, MD

Late False Lumen Expansion Predicted by Preoperative Blood Flow Simulation in a Patient with Chronic Type B Aortic Dissection

Thoracic aortic aneurysms are life threatening and

Percutaneous Approaches to Aortic Disease in 2018

My personal experience with INCRAFT in standard and challenging cases

Open fenestration for complicated acute aortic B dissection

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT

Performance of the conformable GORE TAG device in Type B aortic dissection from the GORE GREAT real world registry

False Lumen Occlusion Techniques in CAD:

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

Ascending Aorta: The Endovascular Approach

I SECTION I. Thoracic aortic aneurysms

What is the benefit. of MEP s in BEVAR for TAAA. in preventing paraplegia?

UC SF An Algorithm to Choose Which Uncomplicated (Asymptomatic) Acute Type B Dissection Patients Should Undergo TEVAR. Disclosures.

Management of Acute Aortic Syndromes. M. Grabenwoger, MD Dept. of Cardiovascular Surgery Hospital Hietzing, Vienna, Austria

Endovascular aortic stent grafts have forever

Total endovascular techniques utilization in aortic dissection radical treatment

Neurological Complications of TEVAR. Frank J Criado, MD. Union Memorial-MedStar Health Baltimore, MD USA

Combined Endovascular and Surgical Repair of Thoracoabdominal Aortic Pathology: Hybrid TEVAR

Acute Type B dissection. Closure of the infra diaphragmatic tear: how and when?

Development of a Branched LSA Endograft & Ascending Aorta Endograft

DISCLOSURES ISOLATED DTA LESION? TYPE B DISSECTIONS TREATMENT OPTIONS

The Current Status Of Endovascular Repair Of Ascending Aorta And Aortic Arch

FLEXIBLE, BALOON EXPANDABLE

Nellix Endovascular System: Clinical Outcomes and Device Overview

Aggressive Resection/Reconstruction of the Aortic Arch in Type A Dissection

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

How to achieve a successful proximal sealing in TEVAR? Pr L Canaud

Paraplegia in endovascular repair of TAA and in TEVAR: Incidence, prevention and therapy. Johannes Lammer Medical University Vienna, Austria

Jean M Panneton, MD Professor of Surgery Program Director Vascular Surgery Chief EVMS. Arch Pathology: The Endovascular Era is here

Understanding the Predictors of Aneurysmal Degeneration in Type B Dissection

False Lumen Backflow In Chronic Aortic Dissections: What Is Its Role and How Can It Be Treated?

CUSTOM-MADE SCALLOPED THORACIC ENDOGRAFTS IN DIFFERENT HOSTILE AORTIC ANATOMIES

Introducing the GORE TAG Conformable Thoracic Stent Graft with ACTIVE CONTROL System

Originally Posted: November 15, 2014 BRUIT IN THE GROIN

Optimal repair of acute aortic dissection

An Overview of Post-EVAR Endoleaks: Imaging Findings and Management. Ravi Shergill BSc Sean A. Kennedy MD Mark O. Baerlocher MD FRCPC

In recent years, the field of endovascular surgery has revolutionized

Antegrade Thoracic Stent Grafting during Repair of Acute Debakey I Dissection: Promotes Distal Aortic Remodeling and Reduces Late Open Re-operation

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

IMH/Penetrating Aortic Ulcers/ Saccular Aneurysms: How to manage and when to intervene

Thoracic aortic trauma A.T.O.ABDOOL-CARRIM ACADEMIC HEAD VASCULAR SURGERY DEPARTMENT OF SURGERY UNIVERSITY OF WITWATERSRAND

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Anatomical challenges in EVAR

Accepted Manuscript. Is A More Extensive Operation Justified for Acute Type A Dissection Repair? Dr. Leonard N. Girardi

Aortic stents, types, selection, tricks in deployment.

Low profile TEVAR: is it an added value? Michel Bosiers, G. Torsello Münster

EVAR and TEVAR: Extending Their Use for Rupture and Traumatic Injury. Conflict of Interest. Hypotensive shock 5/5/2014. none

Aortic Arch pathology options: Open,Hybrid, fenestration, Chimney or branched stent-graft?

Technique and Outcome of Laser Fenestration For Arch Vessels

Introduction. Bumpei Kikuchi, 1 Kazuhiro Ando, 1 Satoshi Nakazawa, 2 Osamu Sasaki, 1 Masatoshi Watanabe, 1 and Akihiko Saito 1

Endovascular Repair of Aortic Arch/Thoracic Aneurysms: Bolton RelayBranch Device

TEVAR for complicated acute type B dissection with malperfusion

Total Endovascular Repair Type A Dissection. Eric Herget Interventional Radiology

THORACOABDOMINAL AORTIC ANEURYSMS HYBRID REPAIR

Mechanisms of and treatment strategies for dsine after TEVAR for acute and chronic type B aortic dissection- insights from EuREC.

Peter I. Kalmar, 1 Peter Oberwalder, 2 Peter Schedlbauer, 1 Jürgen Steiner, 1 and Rupert H. Portugaller Introduction. 2.

Experience of endovascular procedures on abdominal and thoracic aorta in CA region

Endoleaks after F-BEVAR How to Assess & Treat? Gustavo S. Oderich, MD Mayo Clinic Rochester, MN

Left subclavian artery (LSA) coverage during

How to manage the left subclavian and left vertebral artery during TEVAR

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices?

Thoracic endovascular aneurysm repair in Japan: Experience with fenestrated stent grafts in the treatment of distal arch aneurysms

Thoracic Endovascular Aortic Repair (TEVAR) Indications and Basic Procedure

Talent Abdominal Stent Graft

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke

Arch Repair with the Bolton Medical RelayBranch Thoracic Stent-graft system: Multicenter experience

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA

Retrograde Embolization of a Symptomatic Hypogastric Artery Aneurysm

Treatment of acute type B aortic dissection: Current status

UC SF. Disclosures. Thoracic Endovascular Aortic Repair 4/24/2009. Management of Acute Dissections: Is There Still a Role for Open Surgery?

The SPIDER-Graft for Thoracoabdominal Aortic Repair a feasability study in pigs

The role of false lumen intervention to promote remodelling via induced thrombosis the FLIRT concept

Endovascular treatment of aortic arch using Relay branched stent grafts

Current State of Thoracic Branch Devices and Ongoing Clinical Trials

TEVAR for Chronic dissections: indications for TEVAR, long term results

RETROGRADE BRANCH. Gustavo S. Oderich MD Professor of Surgery Director of Endovascular Therapy Division of Vascular and Endovascular Surgery

UC SF Early Intervention in Type B Dissection: Results From the INSTEAD XL Trial. Acute Type B Dissection. Outline. Disclosures.

Transcription:

Kotani et al. Journal of Cardiothoracic Surgery (2017) 12:77 DOI 10.1186/s13019-017-0647-8 CASE REPORT Modified candy-plug technique for chronic type B aortic dissection with aneurysmal dilatation: a case report Sohsyu Kotani 1*, Yoshito Inoue 1, Mio Kasai 1, Satoru Suzuki 1 and Takashi Hachiya 2 Open Access Abstract Background: The original candy-plug technique has been reported to be beneficial for the treatment of residual perfused false lumen in patients with aortic dissection. However, this technique is also associated with several problems, such as narrowing of the true lumen and damage to the flap or vessel wall. Therefore, we modified the procedure to overcome these problems. Here we report a case in which the patient was successfully treated using the modified procedure. Case presentation: A 59-year-old man presented with chronic type B aortic dissection with aneurysmal dilatation. The patient had undergone prosthetic graft replacement of the ascending aorta for acute type A aortic dissection 3 years previously and replacement of the descending aorta for residual type B aortic dissection with aneurysmal dilatation 1 year previously. After these procedures, the residual false lumen aneurysm of the distal descending aorta expanded to 57-mm in diameter. Endovascular stent grafting was successfully performed using the modified candy-plug technique with relining of the true lumen and occlusion of the false lumen. The patient was discharged 10 days after the procedure. Follow-up imaging at 1 year showed a completely thrombosed false lumen aneurysm. Conclusion: The modified candy-plug technique is useful for treatment of residual type B aortic dissection with aneurysmal dilatation. Keywords: Candy-plug technique, Residual type B aortic dissection with aneurysmal dilatation, Endovascular repair Background Recently, thoracic endovascular aortic repair (TEVAR) has become a useful operative treatment for complicated chronic type B aortic dissection by covering the primary entry. However, retrograde flow through distal entries or branch vessels makes complete false lumen thrombosis difficult. Successful exclusion of the false lumen in chronic dissection remains a challenge. Survival is associated with aortic remodelling, which is related to persistence of flow in the false lumen [1]. The original candy-plug technique was described for occlusion of a large false lumen aneurysm of the descending aorta using a candy-shaped stent-graft [2]. However, endovascular intervention with this technique * Correspondence: sohsyu_k@yahoo.co.jp 1 Department of Cardiovascular Surgery, Hiratsuka City Hospital, Kanagawa, Japan Full list of author information is available at the end of the article alone still has two major problems: 1. the possibility of narrowing the true lumen by compression of the candyplug stent [3] and 2. The possibility of flap or vessel wall injury by the stent [3]. To avoid these complications, we designed an efficient modification of the candy-plug device, which is deployed adjacent to the distal end of the stent-graft in the true lumen at the same distal end. Here, we report a case of residual type B chronic aortic dissection with aneurysmal dilatation that was successfully treated using the modified candy-plug technique with an Excluder aortic extender after a staged operation for type A aortic dissection. Case presentation A 59-year-old man with a medical history of hypertension and smoking was diagnosed with acute type A aortic dissection in 2012. The patient underwent emergency surgery, and prosthetic graft replacement of the ascending aorta was performed. Residual type B aortic dissection The Author(s). 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Kotani et al. Journal of Cardiothoracic Surgery (2017) 12:77 with a perfused false lumen aneurysm from the proximal aortic arch to the right iliac artery was followed up by periodic computed tomography angiography (CTA) every 6 months. In 2015, the patient underwent prosthetic graft replacement using a 28-mm Dacron graft (J-Graft SHIELD NEO; Japan Lifeline Co, Ltd., Tokyo, Japan) from the hemi-arch to the descending aorta due to false lumen aneurysm dilatation. Six months after the second procedure, retrograde blood flow persisted through the distal entry in the false lumen, and the dissection with false lumen aneurysm expanded from 47 to 57-mm at its maximum diameter (Fig. 1). It also exhibited a 28-mm false lumen aneurysm and an 8-mm true lumen immediately above the celiac trunk. To dilate the true lumen and occlude the large false lumen, TEVAR was performed using the modified candy-plug technique. Two Conformable TAG stent-grafts (TGU282820J, TGU343420J; W. L. Gore & Associates, Flagstaff, AZ, USA) were selected to deploy in the true lumen. Since proximal diameter was the same as a 28-mm prosthetic graft, a 34*200-mm aortic stent-graft was chosen for proximal true lumen to achieve oversizing by just 20%. The dissection with false lumen aneurysm tapered toward the celiac trunk (8-mm true lumen and 28-mm false lumen), therefore a 28*200-mm aortic stent-graft (two sizes smaller than the proximal device in diameter) was chosen for distal true lumen. Length of thoracic coverage from a 28-mm prosthetic graft to the level of celiac trunk was 168-mm. To keep adequate landing zone, two different size of stent-grafts were required. A 36*45-mm Excluder aortic extender (PLA360400J; W. L. Page 2 of 5 Gore & Associates, Flagstaff, AZ, USA) was chosen for placement of the candy-plug in the distal false lumen based on the preoperative CTA results. This procedure was performed under general anesthesia. To prepare the candy-plug device, a 36*45-mm Excluder aortic extender was partially unloaded from the delivery system. To restrict opening of the stent-graft, a 2 0 Ethibond (Ethicon, Somerville, NJ, USA) suture was placed at the middle of the stent-graft, also using a 22-Fr DrySeal Sheath (DSL2228; W. L. Gore & Associates, Flagstaff, AZ, USA) to limit its maximum diameter to 10-mm, producing a shape similar to a wrapped candy (Fig. 2). Then, the stent-graft was reloaded and prepared in a standard manner. The patient had a false lumen of the left femoral artery and a true lumen of the right femoral artery. First, a Radifocus guidewire (RF-GA35183; Terumo Medical, NJ, USA) was placed through the false lumen via an 8-Fr left femoral sheath, and then a double curve Lunderquist guidewire (TSCMG-35-300-LESDC-JP; Cook Medical, Bloomington, IN, USA) was positioned carefully in exchange for the Radifocus guidewire. Second, a Radifocus guidewire and a double curve Lunderquist guidewire were placed through the true lumen via the right femoral artery in a similar manner. Third, TEVAR was performed via a 24-Fr right femoral sheath. A 28*200-mm Conformable TAG stentgraft was placed in the small true lumen of the descending aorta immediately above the celiac trunk, and then a 34*200-mm Conformable TAG stent-graft was placed at the mid-portion of the 28-mm prosthetic graft of the descending aorta. Next, a customized 36*45-mm Excluder aortic extender was deployed in the large false lumen at the Fig. 1 a Preoperative 3D CTA imaging of a 59-year-old patient showing an aortic dissection with a 28-mm false lumen aneurysm and an 8-mm true lumen immediately above the celiac trunk. b An axial slice at the level of the arrow showing the aortic dissection with a 57-mm triple lumen aneurysm. c, d A saggital slice showing a major distal entry just above the aortic bifurcation (arrowhead)

Kotani et al. Journal of Cardiothoracic Surgery (2017) 12:77 Page 3 of 5 Fig. 2 How to prepare the candy-plug device. a A 2 0 polyester suture placed at the middle of the stent-graft to restrict opening of the stent-graft. b Using a 22-Fr sheath to limits its maximum diameter of its waist to 10-mm. c After customization of the stent-graft. Then the stent-graft was reloaded and prepared in a standard fashion distal end of the 28*200-mm Conformable TAG stent-graft via a 24-Fr left femoral sheath. Finally, a 16-mm Amplatzer Vascular Plug II (9-AVP2 016; AGA Medical Corp., North Plymouth, MN, USA) was placed into the center of the candy-plug of the Excluder extender to complete the occlusion. Postprocedural angiography demonstrated no major complications and no residual retrograde flow into the false lumen aneurysm. The patient was discharged on the 10th postoperative day without any complications. Follow-up CTA at 1 month post-tevar showed no endoleak and almost complete thrombosis of the false lumen above the candy-plug device. CTA at 1 year also showed decreased maximum aneurysm diameter (47-mm), greater expansion of the true lumen, and volume reduction of the thrombosed false lumen (Fig. 3). Discussion The candy-plug technique is a useful treatment option for occlusion of the false lumen in chronic type B aortic dissection. Kölbel et al. originally described this technique using a Zenith TX-2 ProForm stent-graft (Cook Medical, Bloomington, IN, USA) [2]. In this report, the plug was placed in a false lumen in which the true lumen is guarded by a stent-graft. Rholffs et al. reported early results of 18 patients using this candy-plug technique for endovascular false lumen occlusion in chronic aortic dissection [4]. They said their technique was feasible and associated with low morbidity and mortality due to its minimal invasiveness [4]. Ogawa et al. recommended using an Excluder aortic extender for the candy-plug device instead of the Zenith TX-2 due to the ease of modification [3]. However, they placed it at an unprotected level without a stent-graft in the true lumen. They were also concerned about the possibility of complications caused by the candy-plug device. One of the technical problems of the candy-plug is the possibility of narrowing the true lumen as the result of expanding the candy-plug within the false lumen [3]. This possibility presents the risk of thrombosis of the branch vessels, which are located near the distal entries. Another concern is the possibility of flap or vessel wall injury due to continuous shear stress from the candy-plug device [3]. Disproportionate stress from the candy-plug device edge has the risk of intimal injury [5]. According to this previous report, the intimal flap is barely stabilized by being sandwiched the embolized false lumen and stented true lumen. We think that a stent-graft in the true lumen should be deployed at the level of distal end of the occluder device in the false lumen. Our modified candy-plug technique with an Excluder aortic extender can reduce the risk of these complications by deploying it adjacent to the distal end of the stent-graft in the true lumen. A stent-graft in the true lumen can avoid narrowing the true lumen and will thus protect the flap from damage by the candy-plug device. We chose 34-mm and 28-mm aortic stent-grafts for the true lumen and a candy-shaped 36*45-mm Excluder aortic extender for the false lumen while using a 28-mm prosthetic graft in the descending aorta; the 28-mm false lumen aneurysm and the 8-mm true lumen were located immediately above the celiac trunk. In TEVAR for aortic dissection, the size of stent-graft is determined by the diameter of the proximal landing zone. Generally, 10 20% oversizing of the stent-graft based on the proximal landing zone diameter is recommended. In this case, since proximal diameter was the same as a 28-mm prosthetic graft, a 34*200-mm stentgraft was chosen for proximal true lumen to achieve oversizing by just 20%. The dissection with false lumen aneurysm tapered toward the celiac trunk, therefore a two sizes smaller diameter stent-graft was chosen for distal true lumen. A 36*45-mm Excluder aortic extender was selected because of the easy modification and based on the mean

Kotani et al. Journal of Cardiothoracic Surgery (2017) 12:77 Page 4 of 5 Fig. 3 a Postoperative 3D CTA imaging 1 year after TEVAR with implantation of a candy-plug. b A saggital slice showing the candy-plug device with the Amplatzer vascular plug. c Decreased aneurysm diameter and false lumen thrombus formation (at the level of the arrow). d The candyplug with the Amplatzer vascular plug filling the central lumen (at the level of arrowhead) diameter of false lumen which was 31.3-mm. It is difficult to determine the appropriate size of stent-grafts because the thrombosed false lumen will become smaller after candy-plug deployment, and the radial force of its frame may increase. Kölbel et al. selected their customized 42-mm TX-2 ProForm stent-graft based on preoperative CTA results, which identified a false lumen diameter < 36-mm. Ogawa et al. based the diameter of their Excluder extender on the mean diameter of the false lumen observed on axial CTA images. This case had the risk of paraplegia due to long coverage with total false lumen thrombosis. The incidence of symptomatic spinal cord ischemia after TEVAR is ranging between 1 and 5% [6]. Some patients with occluded lower thoracic levels may not suffer from paraplegia whereas others with these segments preserved may well show symptomatic spinal cord ischemia. There are 4 vascular territories supplying the spinal cord (left subclavian, intercostal, lumbar, and hypogastric arteries) and simultaneous closure of some of these vascular territories has association with symptomatic spinal cord injury [6]. We could keep these arteries except intercostal arteries in this case. In addition, we always avoid intraoperative prolonged hypotension. This case didn t show no sign of paraplegia in the perioperative period. Conclusion We performed a successful endovascular repair using the modified candy-plug technique for a residual large false lumen aneurysm in the descending aorta. This technique has the potential to effectively occlude large distal false lumen aneurysms within chronic aortic dissection with aneurysmal dilatation. Abbreviations CTA: Computed tomography angiography; TEVAR: Thoracic endovascular aortic repair Acknowledgements Not applicable. Funding The authors declare no funding for this publication. Availability of data and materials All data generated or analyzed during this study are included in this published article. Authors contributions SK was a major contributor in writing the manuscript. YI and TH performed described surgery, interpreted data, and revised manuscript. MK and SS conceived of the study and participated in its design and coordination. All authors read and approved the final manuscript. Ethics approval and consent to participate Not applicable. Consent for publication This patient included in the study consented to participate in research and consent to publish. Competing interests The authors declare that they have no competing interests. Publisher s Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Author details 1 Department of Cardiovascular Surgery, Hiratsuka City Hospital, Kanagawa, Japan. 2Department of Cardiovascular Surgery, Kawasaki City Hospital, Kanagawa, Japan. Received: 24 March 2017 Accepted: 29 August 2017 References 1. Mani K, Clough RE, OTA L, et al. Predictors of outcome after endovascular repair for chronic type B dissection. Eur J Vasc Endovasc Surg. 2012;43:386 91.

Kotani et al. Journal of Cardiothoracic Surgery (2017) 12:77 Page 5 of 5 2. Kölbel T, Lohrenz C, Kieback A, et al. Distal false lumen occlusion in aortic dissection with a homemade extra-large vascular plug: the candy-plug technique. J Endovasc Ther. 2013;10:484 9. 3. Ogawa Y, Nishimaki H, Chiba K, et al. Candy-plug technique using an excluder aortic extender for distal occlusion of a large false lumen aneurysm in chronic aortic dissection. J Endovasc Ther. 2016;23:483 6. 4. Rohlffs F, Tsilimparis N, Fiorucci B, et al. The candy-plug technique: technical aspects and early results of a new endovascular method for false lumen occulusion in chronic aortic dissection. J Endovasc Ther. 2017;24:549 55. 5. Furukawa T, Uchida N, Yamane Y, et al. A pitfall of false lumen embolization in chronic aortic dissection: intimal injury caused by the embolization device edge. Interact Cardiovasc Thorac Surg. 2017;24:153 5. 6. Czerny M, Eggebrecht H, Sodeck G, et al. Mechanisms of symptomatic spinal cord ischemia after TEVAR. J Endovasc Ther. 2012;19:37 43. Submit your next manuscript to BioMed Central and we will help you at every step: We accept pre-submission inquiries Our selector tool helps you to find the most relevant journal We provide round the clock customer support Convenient online submission Thorough peer review Inclusion in PubMed and all major indexing services Maximum visibility for your research Submit your manuscript at www.biomedcentral.com/submit