Trust Nonin Oximeters, Even For Your Sickest Patients

Similar documents
Nonin Medical OEM Pulse Oximetry Solutions. Superior Performance for Challenging Patient Conditions

Too Good to be True? Three Ways Cheap Pulse Oximeters Could be Short-changing Your Patients and Profits

SenSmart. Universal Oximeter System W: E: T: F:

Appendix E Choose the sign or symptom that best indicates severe respiratory distress.

Choosing Mindray SpO2

ALCO Regulations. Protocol pg. 47

SenSmart Model X-100. The first oximetry system to put regional oximetry, pulse oximetry and ease of use at your fingertips.

The first oximetry system to put regional oximetry, pulse oximetry and ease of use at your fingertips.

Chapter 26. Assisting With Oxygen Needs. Elsevier items and derived items 2014, 2010 by Mosby, an imprint of Elsevier Inc. All rights reserved.

All motion is not created equal.

GE Healthcare. Ohmeda TruSat For wherever your patients take you

Pulse Oximeter Accuracy Study

Oxygen Saturation Monitors & Pulse Oximetry. D. J. McMahon rev cewood

Dr. D.McG.Clarkson Determining the Accuracy of SpO2 Values

Clinical Policy: Oxygen Therapy in the Home Reference Number: CP.MP.485

Chapter 12 - Vital_Signs_and_Monitoring_Devices

Pulse Oximeter Accuracy Study

Home Pulse Oximetry for Infants and Children

Infinity MCable -Masimo SET

Northwest Community EMS System Continuing Education Class Credit Questions Respiratory Assessment January 2012

By utilizing VirtuOx IDTF and our VPOD line of Overnight Pulse Oximeters your center will:

Check a Pulse! When to Question SpO 2, NIBP & EtCO 2 Readings

QOF indicator area: Chronic Obstructive Pulmonary disease (COPD)

MedStar Health considers Continuous Home Pulse Oximetry medically necessary for the following indications:

BTS Guideline for Home Oxygen use in adults Appendix 9 (online only) Key Questions - PICO 10 December 2012

Pulse Oximetry Test: Summary Report

CMS-50E Instructions by Cooper Medical Supplies (These instructions are to supplement the manufacturer s user manual not to replace it!

Pulse oximetry in the accident and emergency department

OXIMETRY TEST INSTRUCTIONS (to be performed by a regulated health professional)

Blood Pressure Estimation Using Photoplethysmography (PPG)

JAMES R. KNIGHT

TABLE OF CONTENTS. Physician's Manual. I. Device Description 2. II. Intended Use 5. III. Contraindications 5. IV. Warnings and Precautions 5

SUBJECT INFORMATION AND CONSENT FORM

Module. Module. Managing Other Chronic Conditions. Managing Other Chronic Conditions

Baseline Vital Signs and SAMPLE History. Chapter 5

They are updated regularly as new NICE guidance is published. To view the latest version of this NICE Pathway see:

Chandra Ramamoorthy MBBS; FRCA (UK) Professor of Anesthesiology, Stanford University. Director of Pediatric Cardiac Anesthesiology

pulse oximetry sensors 2007

ORIGINAL RESEARCH. Effect of road traffic accident contaminants on pulse oximetry among normoxaemic volunteers

Physiological Measurements Training for Care/Nursing & LD Small Group Home Staff

August 2013 CE. Site code # E-1213

Testing Masimo rainbow Technology with vpad-a1 1. Background

Up to 50% of continuous flow oxygen therapy patients experience clinically significant nocturnal desaturation. 1

Sleep diagnostics systems

Julie Zimmerman, MSN, RN, CCRN Clinical Nurse Specialist

Appendix D An unresponsive patient with shallow, gasping breaths at a rate of six per minute requires:

Corporate Medical Policy

What is. InSpectra StO 2?

Introducing the WatchPAT 200 # 1 Home Sleep Study Device

Bronchoconstriction is also treated with medications that inhibit bronchiolar constriction such as: Ipratropium (Atrovent)

Assessing Global Patient Status with the Halo Index

CHF Exercise Tutorial

Recognition and Management of High Loop Gain Sleep Apnea

Capnography. Capnography. Oxygenation. Pulmonary Physiology 4/15/2018. non invasive monitor for ventilation. Edward C. Adlesic, DMD.

Classification Name, Classification Number, Class, Classification Reference: 74BWS I DSK I DXN I

Capnography 101. James A Temple BA, NRP, CCP

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

In 1994, the American Sleep Disorders Association

1. EXECUTIVE SUMMARY 2. PRODUCT SUMMARY

INVOS System Inservice Guide for Pediatric Use. INVOS System Inservice Guide for Pediatric Use

3/13/2014. Home Sweet Home? New Trends in Testing for Obstructive Sleep Apnea. Disclosures. No relevant financial disclosures

505 Recovery rates and training (Pulse Oximeter)

Kenek Edge Pulse Oximeter System. LionsGate Technologies, Inc. User Manual

Chapter 9 Vital Signs and SAMPLE History DOT Directory

Automated Blood Pressure Monitor

Fundamentals of Pulse Oximetry

About VirtuOx. Was marketed exclusively by Phillips Healthcare division, Respironics for 3 years

Identification and Treatment of the Patient with Sleep Related Hypoventilation

Spirodoc. 3D Laboratory for respiratory analysis two functional modes: doctor and patient. Four devices in one. Spirometer with Touch Screen display

ABSTRACTS. Section A: Nellcor Clinical Laboratory

Evaluation of the EQUANOX, FORE-SIGHT and INVOS Systems at St. Francis Hospital in Columbus, GA 1

Pulse. Assess for the following:

Ultra Blue. Test Strips UNISTRIP. Charlotte, NC V2-10/25/2018 TECHNOLOGIES,LLC

Non-Invasive Monitoring

3/30/12. Luke J. Gasowski BS, BSRT, NREMT-P, FP-C, CCP-C, RRT-NPS

Chapter 11. Objectives. Objectives 01/09/2013. Baseline Vital Signs, Monitoring Devices, and History Taking

Bi-Level Therapy: Boosting Comfort & Compliance in Apnea Patients

ABSTRACT. Recent studies have shown that the photoplethysmogram

Global Pulse Oximetry Market: Trends and Opportunities ( )

Empowering the RT with New Noninvasive Monitoring Capabilities

I Can t Breathe! Physiology and Evaluation of the Dyspneic Patient. Christopher Parker, MD Pulmonology, Norman Regional Health Systems

For more information about how to cite these materials visit

CHRONIC OBSTRUCTIVE PULMONARY DISEASE

Effective Treatment for Obstructive Sleep Apnoea

THE HEART THE CIRCULATORY SYSTEM

Clinical Considerations of High Intensity Interval Training (HIIT)

ISO INTERNATIONAL STANDARD

After simple testing that only takes minutes people with elevated test results are then recommended to see their physicians for follow-up.

Design a system of measurement of heart rate, oxygen saturation in blood and body temperature with non-invasive method

Competitive Intelligence Report Technology & Patents

Cover Page. The handle holds various files of this Leiden University dissertation

2 hospital system, tertiary care, community, referral centers

#6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure

Appendix (i) The ABCDE approach to the sick patient

LEARNING OBJECTIVES FOR COPD EDUCATORS

Q.E.D. Saliva Alcohol Test

Evaluation of the Precision and Accuracy of the INRatio 2 Prothrombin Time (PT) Monitoring System

OXYGEN USE IN PHYSICAL THERAPY PRACTICE. Rebecca H. Crouch, PT,DPT,MS,CCS,FAACVPR

Government Agency Catalog

Transcription:

Trust Nonin Oximeters, Even For Your Sickest Patients Trust Nonin Oximeters, Even For Your Sickest Patients An oximeter comparison study of healthy subjects in an independent hypoxia lab simulating the symptoms of COPD patients

Does your oximeter work for all of your patients? How can you know? COPD patients often present with complex co-morbidities CHF COPD CAD Up to 49.5% of COPD discharges have congestive heart failure (CHF) and/or coronary artery disease (CAD). 1 Pulse Wave Distortions can cause inaccurate oximeter readings 2 When a COPD patient is desaturating, the following may be present: Low pulse strength poor blood circulation can result in low pulse strength. Cold hands from a variety of reasons/conditions can also result in low pulse strength. Little or no oxygen reserve COPD patients have little or no oxygen reserve capacity in their lungs and can be living on the edge of hypoxemia. 3 Labored breathing dyspnea can cause labored breathing and chest heaving, which can create pulse wave distortions. As a result it becomes harder for the oximeter to find the true pulse, particularly when the patient s oxygen level is dropping. Low Pulse Strength* Normal Pulse Strength* Low Pulse Strength with Labored Breathing* * Simulated waveforms

Which oximeters are accurate in tracking desaturations? Following Nonin Medical s invention of the fingertip oximeter in 1995 there has been a proliferation of brands introduced. Many of the new oximeters are made by two manufacturers: 2 Beijing Choice Electronic Technology Co Ltd. (Beijing, China) Contec Medical Systems Co Ltd. (Qinhuangdao, China) These two companies make over 30 different oximeter brands and models 2 major retailer brands, distributor brands, and internet brands. Some are FDA-cleared while some are health and wellness devices. Current Accuracy Assessment Methods Can be Flawed Often clinicians assess an oximeter by comparing the oximeter to a tabletop or multi-parameter oximeter using a healthy individual or a COPD patient who is in stable condition. Accuracy assessment is most relevant when done on a COPD patient who is desaturating with associated labored breathing (dyspnea) and low pulse strength.

WHITE PAPER SUMMARY Fingertip Pulse Oximeter Performance in Dyspnea and Low Perfusion During Hypoxic Events P.B. Batchelder, RRT, LRCP, Clinimark Laboratories, Boulder, Colorado CLINIMARK, LLC CLINICAL TESTING AND VALIDATION SERVICES FOR MEDICAL DEVICES Clinimark is an independent laboratory whose purpose is to provide impartial research and clinical laboratory testing for medical device development and FDA regulatory validation in invasive and non-invasive monitoring intended for the medical setting. Clinimark is actively involved with standards organizations, such as the ASTM, ISO, and IEC, working with the FDA in development of worldwide harmonized pulse oximetry standards. OXIMETER PERFORMANCE COMPARISON TEST DESIGN Clinimark conducted a test on human subjects in which they induced the conditions typical of a COPD patient with low pulse strength, dyspnea, experiencing a desaturation, or hypoxic event. They then tested devices from three manufacturers to see which ones could track the hypoxic event. Test Methodology An arm of each subject was cooled with cold air to reduce the blood circulation and create a low pulse strength condition. Multiple desaturation events were induced along with dyspnea (labored breathing). A Nonin oximeter along with a Beijing Choice or Contec Medical fingertip pulse oximeter and a reference device were placed on the test hand. A Nellcor N600x tabletop oximeter was used as the reference device. 100% 95 Figure 1: Example of Frozen Reading 100% 95 Figure 2: Example of No Tracking 90 85 75 70 Frozen Reading The green reference pulse oximeter shows an hypoxic event. The purple pulse oximeter tracked the event. The blue pulse oximeter was frozen. 90 85 75 70 Not Tracking The green reference pulse oximeter shows an hypoxic event. The purple pulse oximeter tracked the event. The blue pulse oximeter was >10% inaccurate.

Only the Nonin oximeter, with PureSAT technology, was able to accurately track desaturations in humans with low pulse strength and labored breathing. RESULTS The charts below show the percentage of subjects in which oxygen level changes were accurately tracked. Nonin vs. Beijing Choice (12 Subjects, 54 Desaturation Events) Nonin vs. Contec Medical (13 Subjects, 61 Desaturation Events) 100 100% 100 92% 92% 92% Percentage 60 40 Percentage 60 40 25% 20 20 0 Nonin Medical Beijing Choice Nellcor N600 (reference device) 0 Nonin Medical 0% Contec Medical Nellcor N600 (reference device) % of Subjects Accurately Tracked 4 The oximeters made by Beijing Choice and Contec Medical failed to track many of the desaturations. These two companies make many of the oximeter brands sold by retailers, internet sellers and distributors. Trust Nonin oximeters, even for your sickest patients. Your oximeter needs to work on all your patients, especially the sickest. Only Nonin makes Nonin.

References: 1 PHC4-provided hospital discharges between Oct 1, 2007 and Sept 30, 2008, Pittsburgh Regional Health Initiative 2010. 2 Nonin Medical, Inc. Data on file. 3 Wild Iris Medical Education, Case Manager CEU, www.nursingceu.com, Chronic Obstructive Pulmonary. 4 In this study, performance was considered acceptable if a test pulse oximeter showed a clear pattern in tracking a hypoxic event from ~95% down to ~<85% then back up to ~95%. nonin.com Nonin Medical, Inc. 13700 1st Avenue North Plymouth, MN 55441-5443 U.S.A. Tel: +1.763.553.9968 1.0.356.8874 Fax: +1.763.577.5521 E-mail: info@nonin.com Nonin Medical B.V. Prins Hendriklaan 26 1075 BD Amsterdam Netherlands Tel: +31 (0)13-79 99 040 Fax: +31 (0)13-79 99 042 E-mail: infointl@nonin.com nonin.com 2016 Nonin Medical, Inc. All trademarks are the property of Nonin Medical, Inc unless otherwise noted. P/N 110499-001-01

White Paper Fingertip Pulse Oximeter Performance in Dyspnea and Low Perfusion During Hypoxic Events P.B. Batchelder, RRT, LRCP, Clinimark Laboratories, Boulder, Colorado INTRODUCTION The first fingertip pulse oximeter was introduced in 1995 by Nonin Medical. For approximately 13 years, it was the sole device in this form factor in which the entire pulse oximeter was housed in the finger sensor (display, engine, power supply and sensor). Due to convenience of size and, apparently few reported performance issues, it saw rapid adoption in the clinical environment. In the last eight years several new portable fingertip pulse oximeters have been introduced. Many of these devices are low cost and available over the counter. Anecdotal information gathered from clinicians indicate that some devices have poor performance which might be due to a combination of poor signal strength (lower perfusion) and labored breathing (dyspnea) resulting in inaccurate SpO 2 and/or pulse rate. Our patients have poor peripheral perfusion (due to beta blockers), dyspnea and motion. [We have seen] slow response time, poor low perfusion performance, freezing, inconsistent performance, no reading. Angie Ebeling, RRT, Pulmonary Rehabilitation; North Memorial Medical Center, Robbinsdale, Minnesota Clinicians see discrepancies in the readings when they compare the cheaper home pulse oximeter to the ones used in the hospital. Barbara Sherwood, BS RRT, NPS, C.O.R.E. Respiratory Services; Minneapolis, Minnesota Clinimark Laboratories, an independent hypoxia lab, was asked to investigate the performance of two newer fingertip pulse oximeters and the Nonin Medical fingertip pulse oximeter during dyspnea and low perfusion. Multiple hypoxic events down to the 70 85% range were induced to verify that the pulse oximeter was able to track saturation changes during these challenging conditions. In order to do this in a repeatable, safe manner this study was conducted in a laboratory setting by creating dyspnea, low perfusion and hypoxia in healthy volunteer subjects. METHODS Prior to study start, Institutional Review Board approval was obtained. 1 The study was registered at clinicaltrials. gov (NCT00881829) and written informed consent was obtained from each subject prior to conducting the study. Devices Under Test Fingertip pulse oximeters from three widely used manufacturers were studied. They were the Nonin 3230 (using the same PureLight and PureSAT technology as the Onyx Vantage 9590 and Onyx II 9550), the Beijing Choice MD300 and the Contec Medical CMS50. The latter two manufacturers distribute under several different names and are representative of many newer fingertip pulse oximeters. All devices are FDA-cleared. Study Design Dyspnea and low perfusion were simultaneously induced in each volunteer test subject. During the dyspneic and low perfusion periods, multiple hypoxic events down to the 70 85% SpO 2 range were induced to verify that the fingertip pulse oximeter was able to track saturation changes during these challenging conditions.

2 White Paper Reference Devices. Two Nellcor N-600x tabletop pulse oximeters were used as reference devices. One was placed on the warm, normal perfusion hand (warm reference) and the other was on the cooled, low perfusion hand (cooled reference). Due to the dynamic nature of this trial (in which the saturation changed rapidly from ~95%, down to the 70 85% range, then back up to ~95%) this trial did not use arterial blood as a reference. This is because arterial blood reference measurement requires a stable saturation for at least one minute. 2 Test Devices. The Nonin fingertip pulse oximeter was placed on one finger of the cooled test hand. One of the newer fingertip pulse oximeters was placed on the remaining finger of the cooled test hand (either a Beijing Choice ChoiceMMed MD300 or a Contec Medical CMS50). Sample Size. The sample size was as follows: Beijing Choice and Nonin = 12 subjects with 54 hypoxic events. Contec and Nonin = 13 subjects with 61 hypoxic events. Low Perfusion. The low perfusion (cooled hand) condition was created by directing chilled air (~55 F) over the right arm and right side of the body. Warm, normal perfusion conditions were created by covering the left arm and shoulder with a blanket. A warm water bottle was placed under the left hand. This allowed the left hand to remain warm with normal perfusion, while the right hand exhibited low perfusion. Dyspnea. Dyspnea was created in healthy volunteer subjects by having the subjects hyperventilate continuously for extended periods of time. After one minute of this intense ventilatory breathing exercise, all subjects in this trial began to fatigue and exhibit labored breathing. Hypoxic Events. Intermittent hypoxic events down to a nadir of 70 85% SpO 2 (based on the reference device) were produced by administration of ~14% oxygen. The subject was asked to hyperventilate continuously during the test with the exception of short periods, at which times the subject was asked to hold their breath which created short hypoxic events down to 70 85%. Analysis. The number of times and the duration for each of the following conditions were totaled: 1. Frozen reading no change in reading of the test device during a hypoxic event. 2. No tracking test device readings displayed were >10% high compared to the reference device during a hypoxic event. 3. No reading blank display. In this study, performance was considered acceptable if a test pulse oximeter showed a clear pattern in tracking a hypoxic event from ~95% down to ~<85% then back up to ~95%. Figure 1: Example of Frozen Reading Figure 2: Example of No Tracking Figure 3: Example of No Reading The red and green reference pulse oximeters show an hypoxic event. The purple pulse oximeter tracked the event. The blue pulse oximeter was frozen. The red and green reference pulse oximeters show an hypoxic event. The purple pulse oximeter tracked the event. The blue pulse oximeter was >10% inaccurate. The red and green reference pulse oximeters show an hypoxic event. The purple pulse oximeter tracked the event. The blue pulse oximeter exhibited three periods of no reading. Warm Reference SpO2 Cold Reference SpO2 Warm Reference SpO2 Cold Reference SpO2 Warm Reference SpO2 Cold Reference SpO2 100 100 100 95 95 95 90 90 90 85 85 85 75 75 75 70 70 70

Fingertip Pulse Oximeter Performance in Dyspnea and Low Perfusion During Hypoxic Events 3 RESULTS Beijing Choice / Nonin MEDICAL Comparison (See Table 1a and 1b) Sample Size: 12 subjects, 54 hypoxic events Beijing Choice Accurately tracked hypoxic events in 25% of subjects Accurately tracked 69% of all hypoxic events Nonin Medical Accurately tracked hypoxic events in 100% of subjects Accurately tracked 100% of all hypoxic events Nellcor normal perfusion (warm hand) reference Accurately tracked hypoxic events in 92% of subjects Accurately tracked 98% of all hypoxic events Nellcor low perfusion (cooled hand) reference Accurately tracked hypoxic events in 100% of subjects Accurately tracked 100% of all hypoxic events Table 1a: Results by Subject (12 Subjects) Subjects Accurately Tracked: % of subjects in which the oximeter accurately followed the changing SpO 2 during all of that subject s hypoxic events Beijing Choice 4 25% Nonin Medical 12 100% Nellcor warm reference 11 92% Nellcor cooled reference 12 100% Contec Medical / Nonin MEDICAL Comparison (See Table 2a and 2b) Sample Size: 13 subjects, 61 hypoxic events Contec Medical Accurately tracked hypoxic events in 0% of subjects* Accurately tracked 16% of total hypoxic events Nonin Medical Accurately tracked hypoxic events in 92% of subjects Accurately tracked 97% of all hypoxic events Nellcor normal perfusion (warm hand) reference Accurately tracked hypoxic events in 92% of subjects Accurately tracked 98% of all hypoxic events Nellcor low perfusion (cooled hand) reference Accurately tracked hypoxic events in 100% of subjects Accurately tracked 100% of all hypoxic events Table 2a: Results by Subject (13 Subjects) Subjects Accurately Tracked: % of subjects in which the oximeter accurately followed the changing SpO 2 during all of that subject s hypoxic events Contec Medical 0 0% Nonin Medical 12 92% Nellcor warm reference 12 92% Nellcor cooled reference 13 100% Table 1b: Results by Hypoxic Event (54 Events) Hypoxic Events Accurately Tracked: % of total hypoxic events across all subjects in which the oximeter accurately followed the changing SpO 2 Beijing Choice 37 69% Nonin Medical 54 100% Nellcor warm reference 53 98% Nellcor cooled reference 54 100% Table 2b: Results by Hypoxic Event (61 Events) Hypoxic Events Accurately Tracked: % of total hypoxic events across all subjects in which the oximeter accurately followed the changing SpO 2 Contec Medical 10 16% Nonin Medical 59 97% Nellcor warm reference 60 98% Nellcor cooled reference 61 100% Use of the cheaper finger pulse oximeters in hospitals is rare, however patients commonly buy the least expensive option. Curt Merriman, RRT, CPFT; C.O.R.E. Respiratory Services, Minneapolis, Minnesota *No individual subject tracked accurately through all of their hypoxic events.

4 Fingertip Pulse Oximeter Performance in Dyspnea and Low Perfusion During Hypoxic Events Discussion In this study the Beijing Choice and Contec Medical fingertip pulse oximeters performed significantly worse than the Nonin Medical fingertip pulse oximeter in dyspneic, low perfusion conditions. References 1 Avista Adventist Hospital Institutional Review Board, FWA 00011584. 2 ISO 601-2-61 First edition 2011-04-01 Medical electrical equipment Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment. Table 3: Total Hypoxic Events Accurately Tracked Nellcor warm reference 98% Nonin Medical 97% Nellcor cooled reference 92% Beijing Choice 69% Contec Medical 21% In the last few years fingertip pulse oximeters have been available in the U.S. as health and wellness devices without FDA clearance or need for a prescription. Patients have begun to purchase and use these devices to guide selfcare. And to a lesser degree, some clinicians are using these uncleared devices as well as similar inexpensive FDAcleared devices in their practice. Concerned clinicians often conduct impromptu evaluations of these devices by putting the oximeter on themselves or on a stable patient under non-stressful conditions and comparing the values to a reference device. Performance in this type of impromptu evaluation is not representative of the dyspneic patient who may have paradoxical chest movement from labored breathing and low peripheral perfusion. Additionally, hypoxic events must be included in the testing to verify that a device is not frozen and is able to track a saturation change. This study indicated that when performance might be most needed during labored breathing with low perfusion the two newer low cost oximeters tested in this study failed to track many of the hypoxic events and, instead froze the readings, read >10% high or blanked the display when the saturation was critically low. onyxvantage.com Nonin Medical, Inc. 13700 1st Avenue North Plymouth, MN 55441-5443 USA Tel: +1.763.553.9968 0.356.8874 Fax: +1.763.577.5521 E-mail: info@nonin.com Nonin Medical B.V. Prins Hendriklaan 26 1075 BD Amsterdam Netherlands Tel: +31 (0)13-79 99 040 Fax: +31 (0)13-79 99 042 E-mail: infointl@nonin.com 2016 Nonin Medical, Inc. All trademarks are the property of Nonin Medical, Inc. unless otherwise noted. P/N 110497-001-01