Replacement of the Ascending Aorta, Aortic Root and Valve with a Novel Stentless

Similar documents
The increasing number of elderly patients with complex

Composite stentless valve with graft extension for combined replacement of the aortic valve, root and ascending aorta

Valve-sparing versus composite root replacement procedures in patients with Marfan syndrome

Disease of the aortic valve is frequently associated with

How to Perform a Valve Sparing Root Replacement Joseph S. Coselli, M.D.

Gelweave TM. Thoracic and Thoracoabdominal Graft Geometries. Ante-Flo TM 4 Branch Plexus. Siena Valsalva TM Trifurcate Arch Graft. Coselli.

Management of Difficult Aortic Root, Old and New solutions

Publicado : Interactive CardioVascular Thoracic Surgery 2011;12:650.

Techniques to preserve the native aortic valve during aortic

AORTIC ROOT RECONSTRUCTION WITH PRESERVATION OF NATIVE AORTIC VALVE AND SINUSES IN AORTIC ROOT DILATATION WITH AORTIC REGURGITATION

The stentless bioprosthesis has many salient features that

Early and Midterm Outcomes of the VSSR procedure with De Paulis valsalva graft: A Chinese single-center Experience in 38 patients

14 Valvular Stenosis

Hemodynamics Benefit of Supra-Annular Design in Failed Bio-Prosthetic Valves

A Loeys-Dietz Patient with a Trans-Atlantic Odyssey. Repeated Aortic Root Surgery ending with a Huge Left Main Coronary Aneurysm 4

Indications and Late Results of Aortic Valve Repair

Aortic valve repair: When and how to employ this novel approach?

To reduce the morbidity and mortality associated with

Operative Strategy. Operative Technique

Acute type A aortic dissection (Type I, proximal, ascending)

Ascending Thoracic Aorta: Postsurgical CT Evaluation

TAVR for Valve-In-Valve. Brian O Neill Assistant Professor of Medicine Department of Medicine, Section of Cardiology

Aortic valve repair: Techniques and Pitfalls. Allan Stewart, MD Columbia University Medical Center New York, NY

CT Appearance of Thoracic Aortic Graft Complications

Surgery for Acquired Cardiovascular Disease ACD

Case. 15-year-old boy with bicuspid AV Severe AR with moderate AS. Ross vs. AVR (or AVP)

Bicuspid aortic root spared during ascending aorta surgery: an update of long-term results

Transcatheter Pulmonary Valve Replacement Update on progress and outcomes

Management of Acute Aortic Syndromes. M. Grabenwoger, MD Dept. of Cardiovascular Surgery Hospital Hietzing, Vienna, Austria

The application of autologous pulmonary artery in surgical correction of complicated aortic arch anomaly

CoreValve in a Degenerative Surgical Valve

Valve-sparing aortic root replacement (VSRR) at the Johns

Management of Fusiform Ascending Aortic Aneurysms

Aortic Root Replacement With the Carboseal Composite Graft: 7-Year Experience With the First 100 Implants

Use of pericardial baffle in the management of intractable bleeding in patients undergoing aortic surgery

MITROFLOW VALSALVA CONDUIT TM

Marfan s S drome: Combined Composite Valve GrAeplacement of the Aortic Root and Transaortic Mihal Valve Replacement

Aneurysms of the proximal ascending aorta represent a

Total arch replacement with separated graft technique and selective antegrade cerebral perfusion

Valve-Sparing Aortic Root Replacement: Early Experience With the De Paulis Valsalva Graft in 51 Patients

Surgical Procedures and Complications

Controversy exists regarding the extent of proximal

Results of Aortic Valve Preservation and Repair

An anterior aortoventriculoplasty, known as the Konno-

Redacement of the AsGending Aorta and Aortic Valve with a Composite Graft: Results in 25 Patients

Reconstruction of the intervalvular fibrous body during aortic and

42yr Old Male with Severe AR Mild LV dysfunction s/p TOF -AV Replacement(tissue valve) or AoV plasty- Kyung-Hwan Kim

CROWN PRT. Inservice implantation guide

Anatomy determines the close vicinity of the sinuses of

Repair or Replacement

Joseph E. Bavaria, M.D. Roberts Measy Professor and Vice Chief CardioVascular Surgery Director: Thoracic Aortic Surgery Program University of

Advances in the Treatment of Acute Type A Dissection: An Integrated Approach

Outcomes of Mitral Valve Repair for Mitral Regurgitation Due to Degenerative Disease

Long-term results (22 years) of the Ross Operation a single institutional experience

Annular Stabilization Techniques in the Context of Aortic Valve Repair

Aortic root false aneurysm from gelatin-resorcinolformaldehyde GRF glue following surgical treatment for type A dissection

The need for right ventricular outflow tract reconstruction

Re-do aortic valve replacement after previous homograft aortic root replacement

The Edge-to-Edge Technique f For Barlow's Disease

Verbrede mediastinum: Treatment

Stentless full root bioprosthesis in surgery for complex aortic valve-ascending aortic disease: a single center experience of over 300 patients

Joseph E. Bavaria, M.D. Roberts Measy Professor and Vice Chief CardioVascular Surgery Director: Thoracic Aortic Surgery Program University of

The Role Of Decellularized Valve Prostheses In The Young Patient

The vast majority of patients, especially children, who

SURGICAL INTERVENTION IN AORTOPATHIES ZOHAIR ALHALEES, MD RIYADH, SAUDI ARABIA

Valve-Sparing Aortic Root Replacement in Loeys-Dietz Syndrome

The Journal of Thoracic and Cardiovascular Surgery

Clinical Commissioning Policy Proposition: Personalised External Aortic Root Support (PEARS) for surgical management of enlarged aortic root (adults)

SOLO SMART. The smart way to return to life. Native-like performance now with stented-like implantability

ACD. Tirone E. David, MD, Christopher M. Feindel, MD, Susan Armstrong, MSc, and Manjula Maganti, MSc

PPM: How to fit a big valve in a small heart

Early and One-year Outcomes of Aortic Root Surgery in Marfan Syndrome Patients

Aortic Arch/ Thoracoabdominal Aortic Replacement

Aortic Regurgitation in Connective Tissue Disorders Special precautions? Carlos A. Mestres MD PhD FETCS

separated graft technique 29 II HCA SCP continuous cold blood cardioplegia P<0.05 I cerebrovascular accident CVA II CVA

Experience with 500 Stentless Aortic Valve Replacements

Composite valve graft replacement has become

Clinical outcomes of aortic root replacement after previous aortic root replacement

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology

We present the case of an asymptomatic, 75-year-old

Role of Sutureless Valves in the Surgeon s Armamentarium Prof. Dr Malakh Shrestha Vice Chair, Director of Aortic Surgery Cardiothoracic,

Midterm Outcome of Valve-Sparing Aortic Root Replacement in Inherited Connective Tissue Disorders. Patients

Aortic valve leaflet sparing and salvage surgery: evolution of techniques for aortic root reconstruction q

Transcatheter aortic valves in aortic regurgitation Gry Dahle Dept of Cardiothoracic- and vascular surgery Rikshospitalet, Oslo University Hospital,

Pulmonary Valve Replacement

Aortic Valve Resuspension in Ascending Aortic Aneurysm Repair With Aortic Insufficiency

Late results of aortic root repair & replacement. John Pepper Imperial College and Royal Brompton Hospital, London, UK.

Durability of Aortic Valve Preservation and Root Reconstruction in Acute Type A Aortic Dissection

TSDA Boot Camp September 13-16, Introduction to Aortic Valve Surgery. George L. Hicks, Jr., MD

HURDLES FOR STARTING MINISTERNOTOMY AORTIC VALVE REPLACEMENT PROGRAM IN OUR INSTITUTE

Interventional procedures guidance Published: 26 September 2014 nice.org.uk/guidance/ipg504

Minimally invasive valve-sparing aortic root reimplantation

Joseph E. Bavaria, MD

Aortic valve insufficiency may be caused by abnormalities

Kinsing Ko, Thom de Kroon, Najim Kaoui, Bart van Putte, Nabil Saouti. St. Antonius Hospital, Nieuwegein, The Netherlands

The Bentall procedure: Is it the gold standard? A series of 597 consecutive cases

PROVEN PLUS. Introducing the Avalus Aortic Valve by Medtronic.

Aortic root aneurysm: Principles of repair and long-term follow-up

Repair of the aortic valve in patients with insufficiency and aortic root aneurysm

Functional anatomy of the aortic root. ΔΡΟΣΟΣ ΓΕΩΡΓΙΟΣ Διεσθσνηής Καρδιοθωρακοτειροσργικής Κλινικής Γ.Ν. «Γ. Παπανικολάοσ» Θεζζαλονίκη

Transcription:

Title: Replacement of the Ascending Aorta, Aortic Root and Valve with a Novel Stentless Valved-Conduit Running Head: Replacement of Ascending Aorta and Valve Authors: Kelvin K.W. Lau MRCS DPhil Krystyna Bochenek-Klimczyk MD Manuel Galiñanes MD, PhD, FRCS Andrzej W. Sosnowski FRCS Institution and Affiliations: Cardiac Surgery Unit, Cardiovascular Sciences Department, Glenfield Hospital, University of Leicester, Groby Road, Leicester, LE3 9QP UK (all authors) Keywords: Aorta; Aortic valve, replacement; aortic root; aortic operation; Valve disease Word Count: 2379 Corresponding author: Manuel Galiñanes, Cardiac Surgery Unit, Cardiovascular Sciences Department, Glenfield Hospital, University of Leicester, Groby Road, Leicester, LE3 9QP, United Kingdom 1

Tel: +44 116 2563032 Fax +44 116 2502449 e-mail: mg50@le.ac.uk 2

Abstract: Purpose Biological valved-conduit grafts avoid the need for anticoagulation, and can exploit the excellent hemodynamic performance of stentless valves. Incorporation of sinuses of Valsalva into the neoaortic root can improve the function of the stentless valves. Description Here we present a novel prefabricated stentless valved-conduit incorporating sinuses of Valsalva and describe the technique of inplantation. The BioValsalva valvedconduit incorporates a stentless porcine aortic valve (Vascutek Elan ) suspended within a triple-layered vascular conduit (Triplex, Vascutek, Renfrewshire, Scotland) constructed with sinuses of Valsalva. Evaluation The BioValsalva valve-conduit was used in twelve patients with aortic regurgitation due to annuloaortic ectasia unsuitable for aortic valve repair and concomitant ascending aorta aneurysm with no mortality and excellent functioned result. Conclusion The prefabricated, composite stentless-valved-conduit, which material is hemostatic and reduces bleeding, is easy to implant with short ischemic time, and lends itself well to a variety of insertion techniques. 3

Introduction: The replacement of the aortic root, ascending aorta and aortic valve with a valvedconduit is a well-established procedure for the treatment of ascending aorta aneurysms and aortic dissection. However, this operation is still associated with high perioperative mortality and morbidity. The nature of the prosthetic material used may play a role in these complications. Knitted vascular conduits did not have favourable handling properties and hemostasis was suboptimal, contributing to mediastinal bleeding, a life-threatening complication. To overcome this problem, woven prostheses with zero-porosity were developed. The use of a xenograft root, which if necessary could be extended distally with a vascular graft, has also been proposed (1). However, the xenograft aortic wall is prone to calcification. If reoperation were required, then replacement of the entire xenograft root would be necessary, compounding the risk of surgery (2). The use of a mechanical valve in a composite graft requires long-term anticoagulation and is a disadvantage especially in elderly patients, in patients unsuitable for anticoagulation, and in patients with extended aortic pathologies, such as aortic dissection and thoracoabdominal aortic aneurysms. Composite valved-conduits using mechanical and bioprosthetic prostheses have traditionally been designed as straight tubes without incorporating the sinuses of Valsalva. The physiological importance of the sinuses is beginning to be recognised. Vortices which form at this site improve blood flow to the coronary arteries and promote earlier and more gradual valve leaflet closure, thus reducing stress of the leaflet coaptation (3). Furthermore, in the absence of the sinuses, there is a theoretical risk of collision of the valve leaflets with the vascular graft resulting in abrasive wear. Therefore, the ideal composite valved-conduit used for replacement of the aortic 4

valve, aortic root and ascending aorta should possess the following characteristics: (i) sinuses mimicking the anatomy of the aortic root, (ii) a synthetic conduit material which should be both hemostatic and easy to handle, whilst resistant to calcification and deterioration with time, and (iii) a valve which does not require anticoagulation, has good hemodynamics and is durable. Here we report on a new bioprosthetic valved-conduit BioValsalva (Vascutek Terumo, UK) which consists of a stentless bioprosthesis, the Elan valve that has been shown to afford excellent hemodynamics with performance (4), within a polyester and polytetrafluoroethylene (PTFE) triplelayered conduit which is hemostatic, has favourable handling properties and incorporates sinuses of Valsalva (Figure 1). Technology The BioValsalva prosthesis consists of a stentless porcine valve (Vascutek Elan ) pre-implanted within a longitudinally-corrugated Triplex vascular graft incorporating sinuses of Valsalva. The selected porcine valves were predilated and preserved with low-pressure fixation in 0.5% buffered glutaraldehyde. They did not receive anti-mineralisation treatment. Only two sizes of the prosthesis were used (26 and 28mm for the conduit and 25 and 27mm respectively for the valve). The diameters of the sinus of Valsalva for these conduits are 32mm and 35mm respectively. As discussed below, different implantation techniques can be used to accommodate one of these two prostheses sizes into a wide range of aortic anatomy. 5

Surgical technique The operation was performed through a median sternotomy. Transesophageal echocardiogram (TOE) was performed in all patients prior to and following separation from CPB. Standard CPB was established between the right atrium and aortic arch with moderate hypothermia (28ºC), or deep hypothermia (17ºC) if circulatory arrest was required. A modified Bentall technique with complete resection of the ascending aorta and aortic valve, and reimplantation of the coronary buttons was used in all patients. The sewing ring of the BioValsalva composite conduit was anastomosed to the aortic annulus using a variety of techniques depending on the aortic anatomy. When the tissue was healthy, continuous and semi-continuous sutures were used, with or without pledget reinforcement. When the tissue quality was poor and the annulus calcified, interrupted mattress sutures were used. Interrupted mattress sutures were also used when a small aortic annulus was encountered, allowing the implantation of a larger root into the supraannular position; whilst everted mattress sutures reinforced with continuous sutures were used when there was a large annulus, to allow a smaller root to be implanted in the intraannular position. The vascular graft was fenestrated with a punch (5.6 mm) and the coronary buttons were anastomosed to the BioValsalva graft using 5/0 Surgipro (Syneture, USA). Following completion of the coronary anastomoses, the tube graft was cut to length and an end-to-end anastomosis to the distal ascending aorta was fashioned using a continuous 3/0 Prolene (Ethicon, USA) suture reinforced with Teflon felt and tissue glue (Glubran, GEM, Viareggio, Italy). 6

Patients with aneurysms extending distally underwent further ascending aorta and arch replacement with a 28mm Dacron conduit. The distal anastomosis was performed under circulatory arrest with a tube-graft inversion technique as described previously (5). Clinical Experience Between December 2006 and June 2007, 12 BioValsalva prostheses were implanted electively in 12 patients (9 males, 3 females) with annuloaortic ectasia and aortic regurgitation resulting from degenerative valve disease unsuitable for repair. The procedure was thoroughly explained and informed consent was obtained for all patients in accordance with the General Medical Council (UK) guidelines. The regional ethics committee has confirmed that ethical approval is not required under the NHS research governance guidelines. The mean CPB time was 145±28 minutes, and the mean aortic cross-clamp time was 95±21 minutes mean ± standard error of the mean). Deep hypothermic circulatory arrest (20-22 minutes) was used in three cases for distal ascending aorta and arch replacement with a 28mm Dacron conduit. There were no in-hospital deaths or reoperations for bleeding or tamponade. All patients underwent post-operative CT of aorta and echocardiography prior to discharge. Figure 2 is a representative axial CT section and Figure 3 shows the valved-conduit in a CT reconstruction. These confirm the presence of three distinct sinuses of Valsalva. The mean peak-gradient of the aortic valve prostheses was 18±6mmHg. The mean effective orifice area (EOA) ± standard error of the mean was 2.2 0.3 and 2.4 0.4cm 2 for the 25 and 27mm prostheses, respectively. In all cases the 7

valve prostheses were functioning well with no evidence of regurgitation. Hematoma was noticed around the ascending aorta in 4 patients. In addition, one patient underwent MRI of the aorta. This latter investigation could not demonstrate obvious dynamic movements of the sinuses of Valsalva during the cardiac cycle, however this important issue should be addressed in future studies in a larger group of patients. Comments: We have shown here that the BioValsalva prosthesis, a novel valved-conduit, can be safely used with short aortic cross-clamp times and good hemostatic properties. We have also shown that the prosthesis is versatile, allowing the use of a variety of surgical techniques to accommodate specific anatomical findings. The availability of such a valve-conduit may have important implications for improving the surgical outcome of the correction of the aortic valve, aortic root and ascending aorta pathology. The Bentall procedure is the gold standard for repair of ascending aortic aneurysms and aortic regurgitation. Universal use of mechanical valves is limited by their need for anticoagulation and suboptimal hemodynamics. With improved durability of bioprosthetic valves coupled with their excellent hemodynamic profile, several groups have modified the Bentall procedure to incorporate stentless aortic valves (1, 6, 7). These were constructed intraoperatively following sizing of the annulus. Intraoperative construction requires an extended cross-clamp time. In addition, imperfectly placed sutures can result in distortion of the valve which might only be identified by TOE upon discontinuation of CPB (8). The new prefabricated BioValsalva valved-conduit eliminates the ischemic time required for the 8

construction of the valved-conduit construction during surgery and the risk of valve malfunction. Our results show a mean ischemic time of 95 minutes, which compares favourably to other series of Bentall operations (8). Composite grafts constructed from the first-generation Toronto SPV valve within a Dacron tube have been shown to have good hemodynamic performance accompanied by good medium-term clinical outcomes (3, 7). The BioValsalva prosthesis utilises an Elan stentless aortic valve that has also been shown to possess excellent hemodynamic performance and clinical results (4, 9). Bleeding is a significant morbidity associated with the Bentall procedure, and can result in the need for reoperation in over 10% in some series. Earlier ascending aorta replacements were complicated by bleeding from needle holes and anastamotic lines. The BioValsalva prosthesis contains a Triplex vascular graft, with an inner woven polyester layer and an outer PTFE layer. The superior hemostatic properties of this conduit can be seen where the valved-conduit was anastomosed to a distal conduit in repairs involving the aortic arch: notably, there was bleeding from the Dacron graft suture holes and not in the valved-conduit. In our series, there were no reoperations and little mediastinal drainage. An added benefit with this vascular graft material is the ease of fenestration with an aortic punch, avoiding the imprecise perforation with electrocautery. Nevertheless, care must be taken to ensure that the valve leaflets are not damaged by the punch because surface tension can draw the leaflets onto the conduit wall. Unlike mechanical valves, optimal functioning of biological valves is affected by the anatomy of the aortic root. The sinuses of Valsalva in particular, may play a role in 9

enhancing durability of the valves. The presence of the sinuses theoretically reduces the impact of the valve leaflets on the conduit during valve opening, and on each other during valve closure, and may improve blood flow in the coronary arteries (3). Another major advantage of the BioValsalva valved-conduit is the relative ease for explantation if a reoperation is needed as the valve is not incorporated into the suture line of the prosthesis to the aortic annulus. Early bioprosthetic valved-conduits were sutured in such a way that both the valve and the vascular graft were incorporated into the anastomosis (6) and in this case full explantation of the valved-conduit is necessary when valve replacement is required. Compared to homograft and xenograft roots, the polyester vascular prosthesis is relatively resistant to calcification and dilation, and would not require replacement. Therefore reoperation could be achieved through entering the graft and excising the stentless valve. A new stentless or stented valve could then be reimplanted into a suitable position. In conclusion, the BioValsalva bioprosthetic valved-conduit belongs to a new generation of prefabricated bioprosthetic valved-conduits with excellent hemodynamic profiles and hemostatic properties incorporating sinuses of Valsalva. Our series showed that this versatile valved-conduit could be implanted easily and safely using a wide range of techniques, for the replacement of the aortic valve, aortic root and ascending aorta, with good short term clinical outcomes. 10

Acknowledgements: No financial support or technical assistance was received for the study. However, Vascutek, Ltd contributed to the cost of publication of the color figures. Disclosure and Freedom of Investigation: BioValsalva valved-conduits were supplied at full cost to our department. The authors had full control in the patient selection, operative technique, study design, data analysis and preparation of the article. As mentioned in the acknowledgments, financial support was obtained for the publication of color figures from Vascutek, Ltd. 11

References: 1 Byrne JG, Mihaljevic T, Lipson WE, Smith B, Fox JA, Aranki SF. Composite stentless valve with graft extension for combined replacement of the aortic valve, root and ascending aorta. Eur J Cardiothorac Surg 2001;20:252-6 2 Dossche KM, Schepens MA, Morshuis WJ, de la Riviere AB, Knaepen PJ, Vermeulen FE. A 23-year experience with composite valve graft replacement of the aortic root. Ann Thorac Surg 1999;67:1070-7. 3 de Paulis R, Tomai F, Bertoldo F et al. Coronary flow characteristics after a Bentall procedure with or without sinuses of Valsalva. Eur J Cardiothorac Surg 2004;26:66-72 4 Flynn M, Iaccovoni A, Pathi V, Butler J, Macarthur KJ, Berg GA. The aortic Elan stentless aortic valve: excellent hemodynamics and ease of implantation. Semin Thorac Cardiovasc Surg 2001;13:48-54. 5 Alexiou C, Sosnowski AW. Tube-graft inversion for the construction of an "open" distal anastomosis during ascending aortic replacement: a new technique. Ann Thorac Surg 2007;83:326-8 6 Urbanski PP. New vascular graft for assembling the stentless valve composite graft. Ann Thorac Surg 2007;84:1771-3. 12

7 de Paulis R, Nardi P, De Matteis GM, Polisca P, Chiariello L. Bentall procedure with a stentless valve and a new aortic root prosthesis. Ann Thorac Surg 2001;71:1375-6 8 Urbanski PP, Diegeler A, Siebel A, Zacher M, Hacker RW. Valved stentless composite graft: clinical outcomes and hemodynamic characteristics. Ann Thorac Surg 2003;75:467-71 9 Akar AR, Szafranek A, Alexiou C, et al. Use of stentless xenografts in the aortic position: determinants of early and late outcome. Ann Thorac Surg 2002;74:1450-7 10 Galla JD, Lansman SL, Spielvogel D et al. Bioprosthetic valved conduit aortic root reconstruction: the Mount Sinai experience. Ann Thorac Surg 2002;74:S1769-72 13

Legends Figure 1: BioValsalva valved-conduit Figure 2: CT aorta after implantation of the BioValsalva valved-conduit demonstrating the origin of the coronary arteries (arrows) and the three sinuses of Valsalva (*) following implantation. Figure 3: CT reconstruction of the aorta following implantation of the BioValsalva valved-conduit. 14