Orthodontic Screw System

Similar documents
TSIII SA Implant System

High-end solution STEP-BY-STEP USER GUIDE

Introduction of Dentium Implant. Help kit

tomas - Anchorage System

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282

The Most Reliable Spinal Solution

SURGICAL PROCEDURES FOR ROXOLID IMPLANTS

NARROW DIAMETER implant

Technique Guide. Orthodontic Bone Anchor (OBA) System. Skeletal implants for the orthodontic movement of the teeth.

2.0 mm Mandible Locking Plate System

ORTH easy. The Complete System for Cortical Anchorage. OrthoEasy Pins

Osteoconductive S.L.A. Surface. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation.

GMI FRONTIER implant system. Surgical procedures guide

EXCELLA ll. Spinal System

4766 Research Dr. San Antonio, TX insightdentalsystems.com

Technique Guide. Midface Distractor System. For the temporary stabilization and gradual lengthening of the cranial or midfacial bones.

Implant Mountless Package Handling. Instructions for Use

MagDen System Magnetic Implant. Catalog/Manual

Mini External Fixator.

orthodontic Bone anchor (oba) SYStem

Fixed Restoration for Atrophic Ridges

FOR C1 & V3 IMPLANTS STEP-BY-STEP GUIDED SURGICAL PROCEDURE

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

SimpleLine II Surgical / Prosthesis Manual

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

Correction System. Surgical Technique

TSLP Thoracolumbar Spine Locking Plate

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

Distal Ulnar Locking Plate

SMV Scientific Bone Plate and Screw System Surgical Technique

External Skeletal Fixation (ESF)

Lag Screw Device Intended for symphyseal fracture fixation of the mandible

Implant System MAKE IT SIMPLE

Sinus Lift System. 1. Crestal approach kit 2. Aqualiftor approach kit 3. Lateral approach Kit

Correction System. Surgical Technique

6. Timing for orthodontic force

The REAL Mini Implant

Ease of Use. Have the instrument you need when you need it.

E-type Straight Nose Cone

System. Humeral Nail. Surgical Technique

INTERNAL HEX ( ps) PLATFORM SHIFT PRESERVATION OF BONE NEVER LOOKED BETTER

a perfect fit SURGERY CAMLOG /CONELOG SCREW-LINE Surgery set and drills Osteotomy sets ALTApin set Sinus set Complementary surgical instruments

QUICK REFERENCE GUIDE. The PreFix Fixator (92000 Series) ALWAYS INNOVATING

LCP Distal Humerus Plates

LOCATOR F-Tx SEATING AND REMOVAL TOOL PROCEDURES ADDENDUM

A-dec 372L or 572L Dental Light on an A-dec Performer Dental Chair INSTALLATION GUIDE

operative technique Kent Hip

Pre-Operative Planning. Positioning of the Patient

NEW NEW. An Extended Solution for Narrow Ridges

INTERNAL HEX Implant System

GMI. MONOLITH implant system. Surgical procedures guide

Service Set Training Presentation English. André Breisinger BU Prosthetics

Conventus CAGE PH Surgical Techniques

LCP Distal Tibia Plate

How something small, can make such a big difference!! Your best choice in overdenture

Dentium Implant System. New Product

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

DHS Plate 135º. DHS Platte 135º

a perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care

156 Neodent Kits. Neodent Kits

A self-tapping internal hex. implant by MAKE IT SIMPLE

SMALL DIAMETER Implant

Ankylos. Acuris conometric concept. Manual and product catalog

American Orthodontics americanortho.com (800) The Aarhus System Mini-Implant Screws/TADs Ti6AL4V surgical grade titanium alloy

Cost-effective immediate restoration in the anterior region of the mandible (isy by CAMLOG)

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm

Technique Guide. IMF Screw Set. For intermaxillary fixation.

UFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics

Fibrlok II 2529 Universal Optical Fiber Splice

Mini External Fixator

OrthoLox Coupling-System

MetaFix Ludloff Plate

ADEPT Extra Fixation Cup. Operative Technique. Delivering Results Through Performance

Zimmer ITST Intertrochanteric/ Subtrochanteric Fixation System. Abbreviated Surgical Technique

Olecranon Locking Plate II

FASSIER DUVAL TELESCOPIC IM SYSTEM S RESCUE SYSTEM 2.0

3.5 mm Locking Attachment Plate

WINSTA-C. Clavicle Plating System

Basic Information on Straumann Guided Surgery. Straumann Dental Implant System

Clavicle Hook Locking Plate

ACETABULAR CUP SURGICAL TECHNIQUE

USS Variable Axis Screw (VAS) System. For posterior fixation of the lumbar spine.

Guidance for. implant removal. Straumann Dental Implant System

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

NR Line Product Catalog

IR (INTELLIGENT) INTERNAL ONE-STAGE SYSTEM

The AperFix II System

28 Surgical Technique

Case Study. Case # 1 Author: Dr. Suheil Boutros (USA) 2013 Zimmer Dental, Inc. All rights reserved. 6557, Rev. 03/13.

Surgical Technique & Product Catalogue. Guide for Open & MIS Procedures

Low Profile Neuro Plating System. Surgical Technique

Straumann Guided Adapter. Basic information on. the Straumann Guided Adapter

NEODENT GUIDED SURGERY

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

fassier DUVal TelescoPIc IM system s RESCUE SYSTEM 2.0

Technique Guide. TomoFix Osteotomy System. A comprehensive plating system for stable fixation of osteotomies around the knee.

Transcription:

1 st Pride ental Group Orthodontic Screw System HEA OFFICE 8th F. WorldMeridian Venture CenterⅡ, 426-5, Gasan-dong, Geumcheon-gu, Seoul, Korea tel_ 82 2 2016 7000, fax_ 82 2 2016 7001 homepage_ http://www.osstem.com MANUFACTURER #507-8, Geoje3-dong, Yeonje-gu Busan, Korea. Zip_ 611-804 tel_ 82 51 850 2500 fax_ 82 51 861 4693 06 MS Inplant System 07

Orthodontic Screw esign Quality Feature Osstem Orthodontic Screw was developed by the R& center of Osstem Implant to help your successful placement with its superior quality. Good Initial Stability esign Concept Good Initial Stability The initial stability of the orthodontic screw is mainly provided by the cortical bone. With this new product, the initial stability is effectively improved by increasing the taper Body. Good Self rilling & Self Tapping Therefore, sufficient final torque for placement and less possibility Good Feeling of Screw Implantation of displacement can be achieved when applied with orthodontic force. Good Strength Resistance of the thread against external load Small Head Size Resistance against Orthodontic Forces 50 Simple Gingiva Shape To use orthodontic screws as a stable anchorage, the screw thread and bone must have sufficient resistance against orthodontic forces. The screw thread and body shape of the new product are designed oad(n) 40 30 20 0.8(022 Wire) to be highly rigid against orthodontic forces. 10 Conventional Competitor ow Profile and Smooth Curved Head 0 0.00 0.05 0.10 0.15 0.20 isplacement(mm) Simple Gingiva Shape Stress istribution The body and thread of the new orthodontic screw are designed to Tapered Body to Increase Cortical Bone Support facilitate stress distribution. Thus, long-term orthodontic force does not give excessive stress to the bone with the new orthodontic screw Strengthened Body esign Powerful Self Threading (0.7 Pitch) Enhanced Body Strength Conventional : 35.3Mpa : 23.8Mpa Comparison of Fracture Strength of Orthodontic Screws 80 70 Simple Head Sharp tip for Self rill Function Through Hole The fracture strength is improved by increasing the upper diameter. The strength is far superior to the conventional products to improve the safety of the placement. However, the 1.4 diameter size has low body strength So requires careful placement. Torque(Ncm) 60 50 40 30 20 10 Competitor Conventional 0 0 1 2 3 4 5 6 7 8 9 10-10 Placement epth 02 03

esign Quality Feature Orthodontic Screw SPEC Excellent Self rill & Self Tapping Function Initial Penetration iagram Orthodontic Screw (Simple Head) There are many cases of placing orthodontic screws without drilling. 5 4 Conventional 1.4 1.4 1.5 The new design provides an excellent initial penetration performance with its sharp tip, and can be placed safely without drilling. However, when the bone is very hard, drilling is recommended to epth(mm) 3 2 Competitor 6 OSSH1406 8 OSSH1408 reduce bone trauma. 1 0 0 5 10 15 20 25 30 35 Time(sec) Placement Torque Increased in the ast Stage 20 Placement torque diagram 1.6 1.6 1.5 6 OSSH1606 The placement torque of the new design is constant in the first half of the placement and increases in the latter half. This enables reliable recognition of the completion of placement and provides an excellent initial stability. Torque(Ncm) 15 10 5 Conventional 8 OSSH1608 10 OSSH1610 0 0 1 2 3 4 5 6 7 8 9 10-5 Placement epth 1.8 1.8 1.5 ow Head and Smooth Curve Profile 6 OSSH1806 8 OSSH1808 The head is designed to be lower than the conventional products to 10 OSSH1810 minimize the foreign body sense for the patients. The design is suitable for the application in narrow space such as anterior. Machined Surface Material: Ti-6AI-4V The straight shape reduces the sense of pressure on the gingiva. (Conventional) () 04 05

Orthodontic Screw SPEC Orthodontic Screw SPEC Orthodontic Screw (Through Hole) Orthodontic Screw 1.6 1.4 1.4 1.5 6 OSTH1406 8 OSTH1408 1.6 2.0 6 WHOS206 8 WHOS208 10 WHOS210 1.6 1.6 1.8 1.8 1.5 2.0 6 OSTH1606 6 WHOSW206 8 OSTH1608 8 WHOSW208 10 OSTH1610 10 WHOSW210 Machine Surface Material: Ti-6AI-4V Through Hole Size : 0.8 1.8 1.8 1.5 6 OSTH1806 8 OSTH1808 10 OSTH1810 Machined Surface Material: Ti-6AI-4V Through Hole Size : 0.8 06 07

Orthodontic Screw SPEC Surgical Instrument Application Case by Orthodontic Screw iameter Surgical Instrument 1.4 When the approach is difficult due to the narrow space between the dental roots of the maxillary/mandibular anterior teeth The 1.4 size has limited strength due to its small size. Pilot drill placement is recommended to prevent fracture. 1.3 1.5 Machine rill river Machine river Where sufficient space can be obtained 1.6 When sufficient initial stability can be obtained from normal bone quality (Hex) river Tip Hand river Hand river Optional Purchase 1.8 Where sufficient space can be obtained When high initial stability is required from soft bone quality Universal Handle The conventional products can be used by coupling a cross driver in the cross slot on the head. When using a cross driver, take care that excessive torque may break the neck. Cross driver is not applicable to the new products which have no slot on their heads. (Using Cross river) 08 09

Surgical Instrument Surgical Instrument rill 1.3 1.5 Machine river Type Hex Cross Code OSOR130C OSOR150C Code OSMA OCM 1.3 1.5 aser Marking: indicated with 6 / 8 / 10 / 12mm Use for the placement of orthodontic screws by connecting to an engine 1.3 rill - use for the placement of 1.4 or 1.6 screws The set consists of Hex and Cross types. Use the Hex type for applying 1.5 rill - use for the placement of 1.8 screw torque, and use Cross type for correcting the through hole path of the Recommended drilling speed: 800rpm (high speed) screw part It is recommended to remove some cortical bone by drilling 29.4 before placement. If the cortical bone is very thick, the drilling depth should be the same as the length of the screw (Caution) o not apply excessive torque with the cross type driver 6 8 10 12 (Hex) Universal Handle Code OUH river Handle Code TIHC Use by coupling with the driver tip. The middle part of the handle is anti-slip processed for easier placement Use manual tightening of the screws coupled with the hand driver 100 30 river Tip Type Hex Cross 70 48 69 Code OST OSTS OCT Use for the placement of orthodontic screws by coupling with the Universal Handle The set consists of Hex and Cross types. Use the Hex type for applying torque, and use Cross type for correcting the through hole path of the Hand river Type Hex Cross Code OSTA OCH Use for the placement of orthodontic screws by connecting to the river Handle or Ratchet Wrench The set consists of Hex and Cross types. Use the Hex type for applying torque, and use Cross type for correcting the through hole path of the screw part screw part (Caution) o not apply excessive torque with the cross type driver. (Hex) (Hex) (Caution) o not apply excessive torque with the cross type driver (Hex) 10 11

Guide for Orthodontic Screw Placement Please read and observe the following guide carefully for successful placement. 1. rilling The design of this product dose not require drilling before placement. However, if the bone is very hard, the excessive placement torque may lead to the failure of the orthodontic screw, In this case, initial drilling is recommended. The placement methods using drilling process of the products are shown below; Make sure to inject a saline solution during drilling to prevent overheating. The recommended drilling speed is 800rpm. 3. Cautions for Placement uring the placement process, maintain the screw path aligned with the direction of insertion and take care not to shake the driver. If the path is deviated or the driver shakes during placement, wobbling may occur as shown below resulting in the fracture of the screw tip. If the insertion path is not correct, it is recommended to remove the screw, correct the path and place the screw again. 1.3 1.3 rilling epth Only Cortical rilling epth Only Cortical 1.4 1.6 Using 1.3 rill (Soft Bone) (Normal Bone) (Hard Bone) 4. Connecting the It is recommended to install the devices (wire, power chain, coil spring, etc.) 1.5 1.5 Orthodontic evices for applying orthodontic force after one or two weeks from the screw placement to secure sufficient initial stability. 1.8 rilling epth Only Cortical rilling epth Only Cortical 5. Removing the Screw To remove a screw, fix the driver in the hex head of the screw and turn in the opposite direction of placement slowly. Using 1.5 rill It is safer to use a Hex river for the products formed with a Cross Slot. (Soft Bone) (Normal Bone) (Hard Bone) Using a Cross river may break the screw neck. 6. Using the Product The orthodontic screws are sterilized and can be placed directly after unpacking. 2. Orthodontic Screw For manual placement, mount the river Tip on the Universal Handle, and connect the screw. To sterilize the product again, mount on the kit socket and sterilize in an autoclave Placement Turn in the clockwise direction with force, at the initial placement speed of one revolution per five (5) seconds. When thread begins to be formed in the bone, apply a rotating force only at 132 C for 15 minutes. This product is a sterilized product for one time use only. o not reuse this product. for further placement. When using an Engine, mount the Machine river on the Hand Piece, and connect the screw. Place the orthodontic screw at the speed lower than 20rpm. Insert the screw until the driver tip touches the gingival tissue, and then remove the driver. 12 13

Coupling Universal river Tip with Orthodontic Screw Maintenance of the Ortho Kit Mounting the river Tip on the Universal Handle uring operation, keep used tools in saline solution or in distilled water. When the operation has been completed, soak all Hold the Universal Handle in the hand, pull the head part on which the river Tip is to be mounted. Pulling the head, insert the Tip to the end. Coupling the Screw with river Releasing the head, turn the Tip slightly When the Tip is mounted fully, the head will give a click sound. the used tools in alcohol for washing. Washing with hydrogen peroxide is prohibited. Caution Exposure to hydrogen peroxide may discolor the laser marking and TiN coating. Wash blood stains and other foreign matter clean with distilled water or flowing water. Coupling the Screw with Universal river Remove the moisture with a dry cloth or a hot air blower. Set the dried tools in the KIT case. (Refer to the color coding for setting the tools in the kit case.) ower the river vertically onto the screw head. Turn the ample to the correct angle with fingers. At the correct angle, a click sound will indicate the coupling. Slowly, lift it up vertically After setting, sterilize the kit in an autoclave at 132 15 minutes and store room temperature. for Coupling the Screw with Machine river ower the river vertically onto the screw head. Turn the ample to thecorrect angle with fingers.at the correct angle, a click sound will indicate the coupling. Slowly, lift it up vertically Caution: After an operation, separate all the tools used in the operation immediately, and wash them before storage. It is highly recommended to sterilize the Surgical KIT again before an operation (temperature: 132C, time: 15 min) The warranty period of the Surgical KIT is One Year after first opening the package, and the warranty cycles of the rills and rivers is 50 cycles. Coupling the Screw in the KIT ower the river vertically onto the screw head. While pressing the river, turn it until it is coupled with a click sound. Slowly, lift it up vertically 14 MS Inplant System 15