Radiation Safety in the Catheterization Lab

Similar documents
Utilize radiation safety principles to reduce the amount of radiation used to achieve desired clinical result.

Why radiation protection matters?

Krueger-Gilbert Health Physics, Inc.

Krueger Gilbert Health Physics, Inc.

Radiation Safety For Anesthesiologists. R2 Pinyada Pisutchareonpong R2 Nawaporn Sateantantikul Supervised by Aj Chaowanan Khamtuicrua

Managing the imaging dose during Image-guided Radiotherapy. Martin J Murphy PhD Department of Radiation Oncology Virginia Commonwealth University

Interventional Fluoroscopy Patient and Staff Safety. Procedures. Safety objectives. Medical physics tasks. Comparative patient risks.

Radiologic Units: What You Need to Know

RADIATION SAFETY. Junior Radiology Course

The Basics of Radiation Safety

Radiation Protection- Cath lab

Biological Effects of Ionizing Radiation Module 8 - AAPM/RSNA Curriculum. Basic Radiation Biology

Medical Fluoroscopic Exposures and Incidents

3/5/2015. Don t Electrocute Me!: Common Misconceptions in Imaging and Radiation Safety (and What to Do About Them)

Dosimetric Consideration in Diagnostic Radiology

Managing the imaging dose during image-guided radiation therapy

Radiation protection for patient and staff during routine EVAR and TEVAR procedures Miltos Matsagkas, MD, PhD, FEBVS

Radiation Safety for New Medical Physics Graduate Students

CT Radiation Risks and Dose Reduction

ARRT Specifications Radiation Exposure & Monitoring

Basic radiation protection & radiobiology

Dose-equivalent equivalent = absorbed

Debra Pennington, MD Director of Imaging Dell Children s Medical Center

Table of Contents. Introduction 3. Background 4

Article Excerpts: Radiation protection concerns among staff performing Fluoroscopic procedures.

Why is CT Dose of Interest?

Quiz True/False: Large amounts of radiation to insects will cause them to mutate!

Vascular & Interventional Education Days Thomas M Griglock, Ph.D., DABR Chief Diagnostic Imaging Physicist, OHSU

Radiation Dose in Pediatric Imaging

The print quality of this copy is not an accurate representation of the original.

Radiation Doses in Radiology: Influence of Standards and Regulations

Radiation Burden in Cardiology. A quick tour! David Sutton

Radiation Units and Dosimetry 15 August Kalpana M. Kanal, Ph.D., DABR 1

Radiation physics and radiation protection. University of Szeged Department of Nuclear Medicine

The x-rays produced penetrate the body which absorbs, refracts, or reflects the x-ray beam energy depending on the tissue. Bone

Module Rhodes

Radiation Safety. Bethany Gillett 14th Feb After this lecture, you should be able to:

Managing Radiation Risk in Pediatric CT Imaging

Radiation Exposure 1980 to 2006

Dose Estimates for Nuclear Medicine Procedures: What are they? Where do they come from?

Laboratory Safety 197/405. Types of Radiation 198/405

Radiation Dose Specification

2017 Course of the Nordic Association for Clinical Physics on occupational dosimetry in hospitals

Managing Patient Dose in Computed Tomography (CT)

Patient Management Image Selection Radiation Biology, Dosimetry & Protection

Radiopharmaceuticals. Radionuclides in NM. Radionuclides NUCLEAR MEDICINE. Modes of radioactive decays DIAGNOSTIC THERAPY CHEMICAL COMPOUND

RADIATION MONITORING DEVICES R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S

Fetal Dose Calculations and Impact on Patient Care

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

Radiologist Update on the Relative Patient Doses Associated with Diagnostic Imaging Modalities Today

Health Physics and the Linear No-Threshold Model

Background Radiation in U.S. ~ msv/yr msv/yr ~0.02 ~0.02 msv msv/day /day (~2 m rem/day) mrem/day) NCRP 4

People Exposed to More Radiation from Medical Exams

DETERMINATION OF ENTRANCE SKIN DOSE FROM DIAGNOSTIC X-RAY OF HUMAN CHEST AT FEDERAL MEDICAL CENTRE KEFFI, NIGERIA

Estimation of Organ and Effective Doses for Neonate and Infant Diagnostic Cardiac Catheterizations

Staff Exposure Monitoring in Interventional Radiology

"The Good Side of Radiation: Medical Applications"

created by high-voltage devices Examples include medical and dental x-rays, light, microwaves and nuclear energy

Further there has been shift from equipment focus to patient focus. During the last 15 years QC testing of equipment and dosimetry in phantoms

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

RADIOLOGY AN DIAGNOSTIC IMAGING

Ionising radiation is EM radiation that causes ionisation of atoms. The minimum energy needed to ionise any atom is 12 ev.

Radiation Safety Training Module: Diagnostic Radiology Radiation Protection in Diagnostic Radiology

Accounting for Imaging Dose

Ionizing Radiation. Michael J. Vala, CHP. Bristol-Myers Squibb

RADIATION INJURY OF THE SKIN FOLLOWING DIAGNOSTIC AND INTERVENTIONAL FLUOROSCOPIC PROCEDURES

Ionizing Radiation Exposure of the Population of the United States. David A. Schauer Executive Director

Outline. NCRP Scientific Committee 6-2

Ionizing Radiation. Nuclear Medicine

Measurement of Scattered Radiation Dose Around Radiology Unit at Dr. Saiful Anwar Hospital, Malang

ACUTE RADIATION SYNDROME: Diagnosis and Treatment

Pediatric Blunt Abdominal Trauma: Solid Organs, Seatbelts, and Sieverts. 23 March. The Plan. Tucker Redfern Symposium Ramin Jamshidi, MD FACS

Research Journal of Pharmaceutical, Biological and Chemical Sciences

Prof. Dr. Doğan BOR Ankara University Institute of Nuclear Science

Radiation Safety Manual

Upon successful completion of the course, the student should be competent in the following tasks:

Introduction. Chapter 15 Radiation Protection. Advisory bodies. Regulatory bodies. Main Principles of Radiation Protection

Recent Progress in Radiation Dosimetry for Epidemiology and Radiological Protection. John Harrison ICRP Committee 2

Ask EuroSafe Imaging Tips & Tricks. Interventional Radiology Working Group. How to control or reduce staff doses during IR procedures

Or Complying with JC standards

International Radiation Protection Association EYE DOSE GUIDANCE (and EPRI Workshop) -- SPRING

Radiation Protection in Laboratory work. Mats Isaksson, prof. Department of radiation physics, GU

Skyscan 1076 in vivo scanning: X-ray dosimetry

Practice and Risk at Medical Facilities in Agency Operations

Radiation related illnesses: risks and awareness

in developing institutional policies, procedures, and /or protocols. The Canadian Society of

TM on the New Dose Limits for the Lens of the Eye: Implications and Implementation

Quality and Safety of Patient Healthcare and Personalized Medicine Using Ionizing Radiation

Variation of Occupational Doses among Subspecialties in Diagnostic Radiology. A.N. Al-Haj, C.S. Lagarde, A.M. Lobriguito

Radiation Safety Guide. Analytical X-Ray Equipment

Radiation Safety General Awareness and ALARA Training

Chem 481 Lecture Material 3/11/09

Radiation Safety. Disclosures

PHY138Y Nuclear and Radiation

UQ X-ray Safety Training Module

Radiation Safety in the Modern Radiology Department: A Growing Concern

Session 83X Dose Management: Patient and Staff Radiation Safety in Radiology

Patient Dosimetry in Interventional Procedures: what to measure and estimate, why and how?

Public and Worker Health Impacts from the Fukushima Nuclear Plant Accident Thomas McKone, PhD & James Seward, MD, MPP

Mapping the ASRT Objectives for Radiation Protection (47 Objectives) and Radiation Biology (21 Objectives) to this Text

Transcription:

SCAI FALL FELLOWS COURSE - 2015 Radiation Safety in the Catheterization Lab V. Vivian Dimas, MD, FSCAI Associate Professor Pediatrics, Cardiology UT Southwestern Medical Center Dallas TX

None Disclosures

Radiation Safety Ionizing radiation can directly/indirectly damage DNA Health effects vary widely Type of radiation Total radiation dose Dose rate SECONDS HOURS DAYS YEARS GENERATIONS biochemical effects cell division CNS and GI effects Cancer Genetic effects

Radiation Safety The more frequently cells divide (mitotic rate) the more sensitive they are to radiation injury. The more specialized (degree of differentiation) the cells are, the less sensitive they are to radiation injury. At low doses, radiation effects are a statistical probability. In all cases the effects of radiation will be delayed.

Radiation Safety: Biological Effects Stochastic Injury Cell is modified (not lost) and reproduces Single cell injury Probability dose Severity not related to dose Does not have a threshold Cancer Deterministic Injury Number of cells lost in an organ/tissue resulting in loss of tissue function Injury to multiple cells Has a threshold. Dose dependent. Severity related to dose Cataracts, skin erythema/necrosis Deterministic, dermis, dose dependent

Radiation Safety: Terminology Quantities measured in sieverts represent stochastic risk A biological effect/impact Measure of the health effect of low levels of radiation Used to represent the risk of the effect Not used for high dose rates of radiation (which are typically related to deterministic effects) 1 Sv = 1 J/kg = 1Gy Quantities measured in gray are typically those that relate to deterministic risk A physical quantity 1 Gy = 1 J/kg = 1 Sv 1 gray (Gy) = 100 rem = 1 Sv

Radiation Safety: Terminology Fluoroscopic time: duration fluoro is used Does NOT include cine acquisition Alone, is not a useful descriptor of patient dose Air Kerma (sum of kinetic energy released per unit mass) Sum of energy of charged particles liberated by ionizing radiation in a unit mass of air (J/kg = Gy) Measures ionization in air not tissue Chambers et al. CCI 2011; 77(4): 546-56

Radiation Safety: Terminology Total Air Kerma at the interventional reference point (K a,r, Gy) Used to monitor thresholds/patient dose Cumulative procedural dose of x-ray energy (delivered to air) at the reference point (usually along central xray beam) Required since 2006 on interventional x-ray systems Associated with deterministic effects (skin effects) Not a true peak skin dose Chambers et al. CCI 2011; 77(4): 546-56

Radiation Safety: Terminology Air Kerma area-product (P ka, Gy-cm 2 ) Previously the dose area product Absorbed dose (air kerma in mgy or Gy) x exposed area in cm 2 Displayed on most current screens Used to monitor patient dose and possible risk of inducing cancer Chambers et al. CCI 2011; 77(4): 546-56

Radiation Safety: Terminology Effective dose (msv) Calculated value Marker of stochastic risk Takes 3 factors into account: Absorbed dose to all organs (total body vs organ specific; weighted for tissue) Relative harm level Sensitives of each organ Used to assess potential for long term effects from procedure Not intended to apply to a specific patient

Radiation Safety: Terminology Peak Skin Dose (PSD, Gy) Max dose received at any area of skin Derived not measured (Ka and x-ray geometry physicist) Determines deterministic effects of exposure (probability and severity increase as PSD increases) Dependent on dose rate and duration x-ray beam directed toward area Calculated by physicist

Radiation Safety: Terminology Einstein AJ et al. Circulation. 2007;116:1290-1305

Radiation Safety: Biological Effects 0-2 Gy 2-5 Gy 5-10 Gy 10-15 Gy 15 Gy < 2 weeks: None 2-8 weeks: None 6-52 weeks: None Permanent: None < 2 weeks: Transient erythema 2-8 weeks: Epilation 6-52 weeks: Recovery from hair loss Permanent: None expected < 2 weeks: Transient erythema 2-8 weeks: Persistent erythema/epilation 6-52 weeks: Prolonged erythema and permanent partial epilation/full recovery Permanent: Full recovery to dermal atrophy/induration < 2 weeks: Transient erythema 2-8 weeks: Erythema, epilation, dry/moist desquamation 6-52 weeks: Prolonged erythema, permanent epilation Permanent: Telangiectasia, dermal atrophy/induration < 2 weeks: Transient erythema, very high dose moist desquamation, edema/ulceration 2-8 weeks: Erythema, epilation 6-52 weeks: Dermal atrophy with secondary ulceration/induration; high dose dermal necrosis/surgery Permanent: Late skin breakdown Chambers et al. CCI 2011; 77(4): 546-56 Balter et al. Radiology 2010; 254: 326-41 The Joint Commission has identified a peak skin dose > 15 Gy as a sentinel event (cumulative over 6-12 months)

Radiation Safety: Dose estimates < 100 msv considered low dose Annual background radiation: 3.1 msv Chest xray: 0.1 msv Whole body CT scan: 10 msv Cardiac CT 16 msv Chest CT 7 msv Adult catheterization: Diagnostic coronary 9.1 msv PCI 17 msv Pediatric cardiac catheterization: Diagnostic/straight forward interventions: < 5 msv Most < 20 msv Einstein AJ et al. Circulation 2007; 116: 1290-1305 Pantos I et al. Curr Cardiol Rev 2009 Jan; 5(1): 1-11

Radiation Safety ALARA As low as reasonably achievable Basically keep the dose as low as possible Assume no safe dose (linear no threshold model)

Radiation Safety: monitoring Personal dosimeter Required nationally by law 2 locations: Collar outside protective garment May overestimate some areas Waist below protective garment Ann ICRP 2000; 85: 25-43

Radiation Safety: Recommended maximum dose RADIATION WORKER Whole body dose < 50 msv/yr (NCRP) 100 msv/5 yrs (ICRP) Extremities (hands) < 500 msv/yr (both) Lens of eye < 150 msv/yr (both) Fetus (after declaration of pregnancy) < 0.5 msv/mo (5 msv/term) (NCRP) 1 msv/term (ICRP) GENERAL POPULATION Avg of 1 msv/yr of effective dose

TIME Radiation Safety. How to reduce exposure DISTANCE SHIELDING EDUCATION

Radiation Safety. How to reduce exposure: time Focused study Plan Avoid unnecessary angiograms If an angiogram is redundant, don t do it Fluoroscopy is ~95% of the time, and ~40% radiation Cine ~5% time and 60% radiation

Radiation Safety. How to reduce exposure: time Plan the angiograms and views review prior angiograms, CT, MRI Use lowest acceptable frame rate Image quality and radiation dose are tightly coupled Reduction of one results in reduction of the other Do not use fluoroscopy to make changes to patient/table position or collimators/shields If your eye is not on the screen, step off

Radiation Safety. How to reduce exposure: distance Goal is to decrease exposure to scatter Physician radiation exposure is changed by camera projection Steep angulation of x-ray beam increases radiation dose and scatter Collimation decreases scatter Increased BMI increased dose and subsequently increased scatter

Radiation Safety. How to reduce exposure Take a step back during cine Double the distance from the patient and reduce exposure by a factor of 4 Copper filters decrease primary beam exposure skin dose Remove anti-scatter grids when catheterizing small children Air gap technique Can reduce dose without compromising image quality

Radiation Safety. Where is exposure? Scattered radiation main source of exposure for operator and staff Most scatter originates from beam entrance Intensity of scatter radiation decreases with increasing distance from the patient Heidbuchel et al; Europace 2014; 16(7) 946-64

Time. Distance Shielding Radiation Safety. How to reduce exposure Remote shielding, should use it Wear lead protective aprons Hang aprons appropriately (avoid cracks) Education Institutional radiation safety programs Dosimeter badge SCAI Pediatric QIT

Radiation Safety. How to reduce exposure Precautions to minimize exposure to patient and operator Minimize cine Avoid steep angles Minimize magnification Minimize frame rate Collimate Keep detector close to patient Monitor real time doses Minimize exposure to operator Use protective garments Maintain garments appropriately Maximize distance of operator from x- ray source and patient Utilize shielding (above and below table) Keep body parts out of field of view Minimize exposure to patient Keep table height as high as comfortable Vary imaging beam angle Keep non-target body parts out of beam

Radiation Safety: Post-procedure issues Record both K a,r and P ka for each case For K a,r > 5 Gy should document in chart and counsel patient regarding possible skin changes K a,r > 10 Gy (P ka > 1000 Gy-cm 2 ) notify physicist to calculate PSD Follow up pt in 2-4 weeks for skin exam PSD > 15 Gy notify hospital risk mgmt within 24hrs Must be reported to regulatory agency

Radiation Safety Children are potentially at greater risk of stochastic effects: Tissues more sensitive to radiation than adults Younger at time of radiation, longer period of time for malignancies to develop Many receive high doses over a lifetime (previously untracked) CT scans, CXRs, Catheterizations.

Radiation Dose Benchmarks During Cardiac Catheterization for Congenital Heart Disease in the United States 7 sites participating in C3PO Fluoroscopy alone not adequate; correlated poorly with DAP (P ka ) and K a,r 75 th Percentile for adult diagnostic cath 1180 mgy; PCI 3120 mgy (95 th 4050 mgy) J Am Coll Cardiol Intv. 2014;7(9):1060-1069

Radiation Safety Tracking and recommendations specific for pediatrics in the works: Quality Metrics Working Group of ACC Radiation dose metric for procedures IMPACT Lifetime risk unknown Longer life expectancy stochastic risk? Gamma-H2AX used as biomarker Formed when double stranded DNA breaks 1:1 ratio to DSBs Kuo LJ et al. In vivo 2008; 22: 305-310

Radiation Safety Focus on radiation reduction: Flat panel detectors Digital image acquisition Stored fluoroscopy Pediatric dosing Increased awareness