Made to make a difference

Similar documents
HEALICOIL REGENESORB Suture Anchor V1 07/14

The first cannulated retrograde drill providing precision and control from a guide wire. ACUFEX TRUNAV Retrograde Drill

Type of evidence. Design rationale. Economic analysis

Comprehensive Product Offerings for Your Rotator Cuff Repair

Precisely locate anatomic femoral ACL insertion sites 1. ACUFEX PINPOINT Anatomic ACL Guide System

SURGICAL TECHNIQUE VISUALIZE FEMORAL FIXATION 360 GRAFT TO BONE CONTACT INCREASED PULL-OUT STRENGTH

EndoWorld OSM19-5-E/ MegaFix. The Bioabsorbable Interference Screw. KARL STORZ SPORTS MEDICINE, Inc.

Double Bundle ACL Reconstruction using the Smith & Nephew Outside-In Anatomic ACL Guide System

Tensioning a Soft Tissue ACL Graft

Comprehensive Product Offerings for Your Rotator Cuff Repair

Initial Fixation Strength of Bio-absorbable Magnesium Screw

Modified Lemaire tenodesis with an iliotibial band graft and BIOSURE REGENESORB interference screw fixation

Transtibial PCL Reconstruction. Surgical Technique. Transtibial PCL Reconstruction

ENDOBUTTON Family of Fixation Devices. Often imitated, never equaled, the gold standard for femoral fixation.

ENDOBUTTON Family of Fixation Devices. Often imitated, never equaled, the gold standard for femoral fixation.

Calcium Phosphate Cement

Properties of GENESYS TM Biocomposite Material Compared to Pure Polylactide (PLA)

A sequenced approach to flush graft placement. GLENOID BONE LOSS SYSTEM Procedural Solution

AFX. Femoral Implant. System. The AperFix. AM Portal Surgical Technique Guide. with the. The AperFix System with the AFX Femoral Implant

YEAR DATA STEP. Proven results in cartilage repair. CARGEL Bioscaffold. Supporting healthcare professionals for over 150 years

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

Double Bundle PCL Reconstruction. Surgical Technique

Surgical Technique. Calcaneal Locking Plate

Cannulated Screw System. Product Overview

ACL reconstruction with the ACUFEX Director Drill Guide and. ENDOBUTTON CL Fixation System. *smith&nephew. Knee Series Technique Guide ENDOBUTTON CL

Surgical Technique. Clavicle Locking Plate

Remnant Preservation in ACL Reconstruction: Is it Worth Doing?

*smith&nephew CONTOUR

Flexibility In Action. ACL Instrumentation

Surgical Technique. Olecranon Locking Plate

Surgical Technique. Proximal Humerus Locking Plate

ACL Reconstruction for BTB Grafts

Knee Preservation System

Anterior cruciate ligament reconstruction using the Bio-TransFix femoral fixation device. with an anteromedial portal technique.

PCL and extra-articular applications. Stability Versatility Recovery

Tibial Fixation. with TunneLoc Device. Surgical Technique by Mark J. Albritton, M.D. and Sherwin Ho, M.D.

Chart a course for meniscal preservation

5/31/15. The Problem. Every Decade We Change Our Minds The Journey Around the Notch. Life is full of Compromises. 50 years ago..

Surgical Technique. Distal Humerus Locking Plate

Roof Impingement Revisited

Technique Guide. *smith&nephew N8TIVE ACL Anatomic ACL Reconstruction System

RIGIDfix. Soft Tissue. Surgical Technique for Mitek RIGIDfix ACL Reconstruction PRODUCTS. Daniel J. McKernan, M.D. TISSUE SOFT.

Principles of ACL graft fixation. Ph. Landreau Aspetar Doha Qatar

Improved control of knee laxity after dynamic augmentation of ACL suture repair

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Active, yet simple deployment, now with a curved approach. SUTUREFIX All-Suture Anchor

The AperFix II System

Surgical Technique. Figure 1 Figure 4. Figure 3 Figure 5. Figure 6

Surgical Technique. Figure 1 Figure 4. Figure 3 Figure 5. Figure 6

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

28 Surgical Technique

Mechanical Aspects of an Interference Screw Placement in ACL Reconstruction

09/24/2015. AGH Nuts and Bolts of Orthopedics Conference 2015 Chad J. Micucci, M.D. Disclosures NONE

RibFix Blu. Thoracic Fixation System

Resorbable Orthopedic Fixation System

ART /2015-E. Oval Blade Dilators. Anatomical tunnel dilation in cruciate ligament surgery

ACL reconstruction. Osteoconductive absorbable interference screws. Unique material. Optimal design. Adapted to different surgical techniques

Dr. Pablo E. Gelber MD PhD Hospital de la Santa Creu i Sant Pau and ICATME Hospital Universitari Quirón Dexeus (Barcelona, Spain) Figure 2a-d

POWER TO RESTORE WITHOUT LEAVING A TRACE. The only remaining evidence of the trauma

Lateral Location of the Tibial Tunnel Increases Lateral Meniscal Extrusion After Anatomical Single Bundle Anterior Cruciate Ligament Reconstruction

Bio XT Maximising the Material Performance of Resorbable Implants

Surgical Technique International Version. Clavicle Locking Plate

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

LARS ACL. Best practice guidelines

Bioabsorbable Versus Titanium Screws in ACL Reconstruction. A Randomised Controlled Trial with 13 years Follow-up

experts in bone regeneration Osteotwin Sports Surgery Line

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates

Features. The hollow core can be filled with autograft or allograft bone.

Torn ACL - Anatomic Footprint ACL Reconstruction

Locking Ankle Plating System. Surgical Technique

Bone Void Filler. Callos. The Next Generation in Calcium Phosphate Cement A COLSON ASSOCIATE

CROSS PIN TECHNOLOGY FOR AN ANATOMIC ACL

FIXED PERFORMANCE. Soft Tissue ACL Reconstruction

ACL Reconstruction Cross-Pin Technique

Distal Cut First Femoral Preparation

Development of a Novel Hybrid Double-bundle ACL Reconstruction Technique in a Translational Large Animal Model

Alternative Design Report

Human ACL reconstruction

The Most Reliable Spinal Solution

RapidSorb Resorbable Tacks. Resorbable Fixation System.

Foot and Ankle Technique Guide Metatarsal Shortening Osteotomy

More than bone regeneration. A total solution.

Kohei Kawaguchi, Shuji Taketomi, Hiroshi Inui, Ryota Yamagami, Kenichi Kono, Keiu Nakazato, Kentaro Takagi, Manabu Kawata, Sakae Tanaka

Talos -C (HA) and the PEEK-OPTIMA HA Enhanced Technology

TSLP Thoracolumbar Spine Locking Plate

Opening Wedge Osteotomy System using PEEKPower HTO Plate. 2 nd Generation Surgical Technique

Bio-TransFix ACL Reconstruction. Surgical Technique

SpeedBridge and SpeedFix Knotless Rotator Cuff Repair using the SwiveLock C and FiberTape Surgical Technique

Hard to reach areas require specific solutions

BICEPTOR Tenodesis System

Innovative Range of Regenerative Solutions

Advanced FE Modeling of Absorbable PLLA Screws

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine.

*smith&nephew ENDOBUTTON CL. Knee Series Technique Guide. Fixation System

Feature Function Surgeon/Patient Benefit

Trephine System. Principle-based anterior lumbar interbody fusion.

Improved access, ultra-low displacement 1 and the highest fixation strength 1. Q-FIX All-Suture Anchor

Supplemental Use Guide Standard Triple Arthrodesis

Knee Surgical Technique

Improved access, ultra-low displacement 1 and the highest fixation strength 1. Q-FIX All-Suture Anchor

Transcription:

Made to make a difference The difference is bone ingrowth BIOSURE REGENESORB Interference Screw Supporting healthcare professionals

Not all interference screws are created equal Bone ingrowth Open architecture to allow for bone to grow through the screw and attach to the graft 1 Reliable performance Strength expected from a solid absorbable interference screw 2 Advanced material REGENESORB Material is replaced by bone within 24 months in preclinical studies 3

BIOSURE REGENESORB Interference Screw The unique BIOSURE REGENESORB Screw is the first interference screw made out of an advanced biocomposite material with an open-architecture design to allow for bone ingrowth, while also providing the kind of performance expected with a solid absorbable interference screw. 2

The difference is bone ingrowth 1 Open architecture allows bone ingrowth Solid interference screw Conventional solid interference screws limit bone ingrowth to the head and tip of the screw BIOSURE REGENESORB Interference Screw Open-architecture design allows bone ingrowth across the interference screw 1 50 % at 12 weeks Limits bone ingrowth VS Bone ingrowth Approximately 50% bone volume is restored by new bone within center cannulation at 12 weeks as demonstrated by pre-clinical studies. 1 Renderings are for illustrative purposes Micro-CT scan at 12 weeks post-implantation, in an ovine ACL reconstruction study 1 2 Which leads to circumferential graft-to-bone integration Solid interference screw BIOSURE REGENESORB Interference Screw VS Graft Renderings are for illustrative purposes Limited graft-tobone integration A solid screw only allows integration on the side contacting the tunnel wall Transverse micro-ct scan at 12 weeks postimplantation, in an ovine ACL reconstruction study 4 Circumfrential graftto-bone integration Proven integration by bone on all sides of the graft, as demonstrated by a pre-clinical study New bone is integrated into the graft in areas not previously accessed by solid conventional interference screws, resulting in circumfrential graft-to-bone integration, as demonstrated by a pre-clinical study. 4

3 And impacts the healing process. Integration between bone and graft plays a role in the remodeling and healing process, as suggested by several studies. 5-8 RELIABLE PERFORMANCE THAT S EXPECTED FROM A SOLID SCREW The open-architecture design provides the benefits of bone ingrowth without compromising strength or reliability. The BIOSURE REGENESORB Interference Screw exhibits the fixation strength of a solid absorbable interference screw without statistical difference throughout the healing period in a simulated degradation environment. 9 The full length of the BIOSURE REGENESORB Interference Screw is supported by the BIOSURE Driver. Torsional stress is transferred off the screw and onto the driver, resulting in superior performance during insertion. 10,11 White Paper available

Advanced biocomposite material REGENESORB Material is replaced by bone within 24 months The REGENESORB Material mixture is designed to remain mechanically stable for a minimum of six months before subsequently being absorbed and replaced by bone within 24 months. 12 Long-term absorption profile of solid REGENESORB Implant in a preclinical model 6 MONTHS 12 MONTHS 18 MONTHS 24 MONTHS White Paper available Gross anatomy and histology images of a 9x10mm implant of REGENESORB Material evaluated in a direct-in-bone sheep model. Images clearly demonstrate absorption and complete replacement by bone in 24 months. Please note this implant was designed for this preclinical study and is not an exact replica of a BIOSURE REGENESORB Interference Screw. The science behind REGENESORB Material REGENESORB Material is a unique formula of osteoconductive component materials, each proven safe and biocompatible with over decades of clinical use. 13,14 20 % Calcium Sulfate 15 % 65 % PLGA Calcium Sulfate Works in early healing stages at 4 12 weeks 15 Sustained bone formation over 18 months 15 PLGA Comprised of natural products lactic acid and glycolic acid Unlike competitive materials, REGENESORB Material includes a second osteo-conductive material, calcium sulfate. Works in early stages (4 12 weeks) of bone healing 15 Associated with increased levels of local growth factors 16

References 1. As demonstrated by micro-ct analysis and quantifications of bone ingrowth within cannulation of implanted screw in femoral tunnel compared to undisturbed bone in a preclinical ovine ACLR study (49.5%, stdev 12.5%). Data on File at Smith & Nephew, report NCS250. Results of in vivo simulation have not been shown to quantitatively predict clinical performance. 2. Compared to BIOSURE HA Interference Screws. Data on file at Smith & Nephew, reports 15004843, 15002832, 15002353, 15002699. 3. In vivo animal testing has demonstrated that REGENESORB Material is bioabsorbable and is replaced by bone. Implants (9x10mm) were implanted in ovine cancellous bone and compared to an empty defect (9x10mm) at 6, 12, 18 and 24 months (n=6). Micro-CT analysis demonstrated that by 24 months, bone ingrowth into this material (289.5mm3) was significantly greater (p<0.05) than bone ingrowth into an empty defect (170.2mm3) and reaches a bone volume not statistically different from intact bone (188.2mm3). Results of in vivo simulation have not been shown to quantitatively predict human clinical performance. Data on file at Smith & Nephew, report 15000897. 4. Data on file at Smith & Nephew, report NCS250. 5. Kuang GM, Yau WP, Lu WW et al. Osteointegration of soft tissue grafts within the bone tunnels in anterior cruciate ligament reconstruction can be enhanced. Knee Surg Sports Traumatol Arthrosc. 2010 Aug;18(8):1038-51. doi: 10.1007/s00167-009-0910-1. Epub 2009 Sep 25. 6. The Anterior Cruciate Ligament: Reconstruction and Basic Science. Chadwick C. Prodromos, editor. Philadelphia: Saunders; 2008. ISBN: 978-1-4160-3834-4. 7. Current Concepts in ACL Reconstruction. Freddie H. Fu and Stephen B. Cohen, editors. SLACK Incorporated NJ, USA. ISBN: 978-1556428135. 8. Anterior Cruciate Ligament Reconstruction: A Practical Surgical Guide. Siebold, Rainer, Dejour, David, Zaffagnini, Stefano, editors. Springer Science & Business, 2014 ISBN 978-3-642-45349-6. 9. Compared to BIOSURE HA Interference Screws in biomechanical studies. Results between BIOSURE REGENESORB and BIOSURE HA were not statistically significant. Data on file at Smith & Nephew, reports 15004843, 15002832, 15002353, 15002699. 10. Data on file at Smith & Nephew, report 15004843 and 15005418. 11. Compared to 7x23mm Arthrex BioComposite and 7x23mm Mitek Milagro (p<.05). Data on file at Smith & Nephew, report 15005418. 12. In vivo animal testing has demonstrated that REGENESORB Material is bioabsorbable and is replaced by bone. Implants (9x10mm) were implanted in ovine cancellous bone and compared to an empty defect (9x10mm) at 6, 12, 18 and 24 months (n=6). Micro-CT analysis demonstrated that by 24 months, bone ingrowth into this material (289.5mm3) was significantly greater (p<0.05) than bone ingrowth into an empty defect (170.2mm3) and reached a bone volume not statistically different from intact bone (188.2mm3). Results of in vivo simulation have not been shown to quantitatively predict clinical performance. Data on file at Smith & Nephew, report 15000897. 13. Smith & Nephew White Paper 10601161 REGENESORB: Absorbable Biocomposite Material. 14. Data on file at Smith & Nephew, reports 15000897, 15001194, 15000921, 15000919, NCS250. 15. Costantino and Friedman. Synthetic Bone Graft Substitutes (1994) Otolaryngol Clin North Am. 1994 Oct;27(5). 16. Walsh et al, (2003) Clin. Orthop. Rel. Res. Vol 406, Allison Et al (2011) US Oncology and Hematology Vol 7(1).

Ordering Information Reference # Description BIOSURE REGENESORB Interference Screw 72204389 BIOSURE REGENESORB Interference Screw 5mm x 20mm* 72204390 BIOSURE REGENESORB Interference Screw 5mm x 25mm* 72204391 BIOSURE REGENESORB Interference Screw 6mm x 20mm 72204392 BIOSURE REGENESORB Interference Screw 6mm x 25mm 72204393 BIOSURE REGENESORB Interference Screw 6mm x 25mm Reverse Thread 72204394 BIOSURE REGENESORB Interference Screw 7mm x 20mm 72204395 BIOSURE REGENESORB Interference Screw 7mm x 25mm 72204396 BIOSURE REGENESORB Interference Screw 7mm x 25mm Reverse Thread 72204397 BIOSURE REGENESORB Interference Screw 7mm x 30mm 72204398 BIOSURE REGENESORB Interference Screw 8mm x 20mm 72204399 BIOSURE REGENESORB Interference Screw 8mm x 25mm 72204400 BIOSURE REGENESORB Interference Screw 8mm x 25mm Reverse Thread 72204401 BIOSURE REGENESORB Interference Screw 8mm x 30mm 72204402 BIOSURE REGENESORB Interference Screw 8mm x 35mm 72204403 BIOSURE REGENESORB Interference Screw 9mm x 20mm 72204404 BIOSURE REGENESORB Interference Screw 9mm x 25mm 72204405 BIOSURE REGENESORB Interference Screw 9mm x 30mm 72204406 BIOSURE REGENESORB Interference Screw 9mm x 35mm 72204407 BIOSURE REGENESORB Interference Screw 10mm x 20mm 72204408 BIOSURE REGENESORB Interference Screw 10mm x 25mm 72204409 BIOSURE REGENESORB Interference Screw 10mm x 30mm 72204410 BIOSURE REGENESORB Interference Screw 10mm x 35mm 72204411 BIOSURE REGENESORB Interference Screw 11mm x 25mm 72204412 BIOSURE REGENESORB Interference Screw 11mm x 30mm 72204413 BIOSURE REGENESORB Interference Screw 11mm x 35mm 72204414 BIOSURE REGENESORB Interference Screw 12mm x 35mm Reference # Description Instruments 7211138 Guide Wire, 1.2mm x 12" sterile (5 per box) 72201201 Guide Wire, 1.2mm x 18" sterile (5 per box) 72201887 BIOSURE Driver 72204647 BIOSURE Driver, 5mm* 72201888 BIOSURE Ratchet Driver (requires 7207707) 7207707 Ratcheting Handle with Hudson Adapter Reference # Description 72201941 BIOSURE TAP System - includes 1 each of: 72201889 6mm BIOSURE Tap 72201890 7mm BIOSURE Tap 72201891 8mm BIOSURE Tap 72201892 9mm BIOSURE Tap 72201893 10mm BIOSURE Tap 72201887 BIOSURE Driver 72201938 BIOSURE Tap Tray Reference # Description 72201942 BIOSURE EASY TAP System - includes 1 each of: 72201190 6mm BIOSURE EASY Tap 72201191 7mm BIOSURE EASY Tap 72201192 8mm BIOSURE EASY Tap 72201193 9mm BIOSURE EASY Tap 72201194 10mm BIOSURE EASY Tap 72201888 BIOSURE Ratchet Driver 7207707 Ratcheting Handle with Hudson Adapter 72201939 BIOSURE EASY Tap Tray * BIOSURE REGENESORB Interference Screws with 5mm diameter require use with 5mm BIOSURE Driver. For more information contact your local sales representative or visit www.smith-nephew.com BIOSURE REGENESORB Interference Screw BIOSURE Driver BIOSURE TAP System Smith & Nephew, Inc. 150 Minuteman Road Andover, MA 01810 USA www.smith-nephew.com T +1 978 749 1000 US Customer Service: +1 800 343 5717 Trademark of Smith & Nephew. 2017 Smith & Nephew. All rights reserved. Printed in USA. 07344 V2 10/17