Estimating Iodine Concentration from CT Number Enhancement

Similar documents
CT NUMBER ACCURACY ANALYSIS FOR RADIOTHERAPY TREATMENT PLANNING IMAGING

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell

To Shield or Not to Shield? Lincoln L. Berland, M.D.

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report

Patient dose assessment of CT perfusion scanning at the RSCH

Dual-Energy CT: The Technological Approaches

Doses from Cervical Spine Computed Tomography (CT) examinations in the UK. John Holroyd and Sue Edyvean

Dental ConeBeam Computed Tomography (CBCT) X-ray Systems

Paediatric Dose Reduction and Image Quality

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

Dual-Energy Imaging of Bone Marrow Edema on a Dedicated Multi-Source Cone-Beam CT System for the Extremities

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Gender differences in CT calcium scoring: A phantom study

Chapter 6. Hester Gietema Cornelia Schaefer-Prokop Willem Mali Gerard Groenewegen Mathias Prokop. Accepted for publication in Radiology

Breast Cancer PET/CT Imaging Protocol

Computed tomography Acceptance testing and dose measurements

Dual Energy CT of Pulmonary Embolism

X-Ray & CT Physics / Clinical CT

Translating Protocols Across Patient Size: Babies to Bariatric

Biases affecting tumor uptake measurements in FDG-PET

Accounting for Imaging Dose

Patient / Organ Dose in CT

True Dual Energy. Dr. Stefan Ulzheimer, Siemens Healthcare GmbH. DEfinitely Siemens

Alfred Health's CT quality control program

8/18/2011. Acknowledgements. Managing Pediatric CT Patient Doses INTRODUCTION

Why is CT Dose of Interest?

Automated CT Protocol Design Advantages and Pitfalls of Algorithm-Based Technique Selection in Pediatrics. Disclosures 7/22/2014. Learning Objectives

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School

Typical PET Image. Elevated uptake of FDG (related to metabolism) Lung cancer example: But where exactly is it located?

Optimized PET/CT protocols: how much CT is needed? Increasing use of PET-CT. Imaging in Lymphoma

Experimental measurement with an anthropomorphic phantom of the proton dose distribution in the presence of metal implants

State of the art and future development for standardized estimation of organ doses in CT

Outcomes in the NLST. Health system infrastructure needs to implement screening

Conventional and spiral CT dose indices in Yazd general hospitals, Iran

Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters

Radiation Dose Reduction: Should You Use a Bismuth Breast Shield?

CT Radiation Risks and Dose Reduction

Ultralow Dose Chest CT with MBIR

E. Senéterre*, F. Paganin**, J.M. Bruel*, F.B. Michel**, J. Bousquet**

FDG-18 PET/CT - radiation dose and dose-reduction strategy

Cone Beam CT Protocol Optimisation for Prostate Imaging with the Varian Radiotherapy OBI imaging system. Dr Craig Moore & Dr Tim Wood

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

Managing Radiation Risk in Pediatric CT Imaging

Cardiac CTA Prospective Gating Broad Beam

National Cancer Institute

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

Dual-Energy 101: Principles, Methods and Dose

An audit of radiation dose of 4D CT in a radiotherapy department

Quantitative and Qualitative Assessment of Thorax Cone Beam CT Image Quality across Multiple Imaging Systems

CT angiography of pulmonary arteries to detect pulmonary embolism with low kv settings

Low Dose CT Lung Screening: What is Technically Required?

Survey of patients CT radiation dose in Jiangsu Province

Improved image quality of low-dose thoracic CT examinations with a new postprocessing software*

Calculation of Effective Doses for Radiotherapy Cone-Beam CT and Nuclear Medicine Hawkeye CT Laura Sawyer

Measurement error of spiral CT Volumetry:

Managing the imaging dose during Image-guided Radiotherapy. Martin J Murphy PhD Department of Radiation Oncology Virginia Commonwealth University

Crowd-Sourcing Quality in Imaging

A multicentric study on patient dose in multislice CT

Guidelines for the Management of Pulmonary Nodules Detected by Low-dose CT Lung Cancer Screening

Fused monochromatic imaging acquired by single source dual energy CT in hepatocellular carcinoma during arterial phase: an initial experience

CT examination is a high-radiation-dose imaging technique

Loren Ketai, MD; Mathurn Malby, BS; Kirk Jordan, MD; Andrew Meholic, MD; and Julie Locken, MD

Whole Body CT Protocol Update 2018

Measurements of Air Kerma Index in Computed Tomography: A comparison among methodologies

Chapter 5. Pulmonary nodules detected at lung cancer screening: Interobserver variability of semiautomated volume measurements

4D PET: promises and limitations

Hi RES Extremity - (04/18/2011) CTDI: ~13 mgy per acquisition Used for evaluation of: Ankle Elbow Hand Wrist Foot /Calcaneous Toes Fingers

Cardiopulmonary Imaging Original Research

Uozu city/jp, Minatoku, Tokyo/JP Bones, Extremities, CT, Surgery, Physics, Artifacts, Image verification /ecr2014/C-0462

HI-Res Extremity Sensation 16

CT angiography techniques. Boot camp

PET CT for Staging Lung Cancer

Ask EuroSafe Imaging. Tips & Tricks. CT Working Group. Optimization of scan length to reduce CT radiation dose

8/1/2017. Financial Disclosures. Dose Tracking at MGH. How Dose Tracking Affected Protocol Optimization in a Tertiary Quaternary Healthcare Center

THE SAAD CENTRE FOR RADIOGRAPHY OPEN FOR BUSINESS. The University for business and the professions

Optimizing radiation dose by varying age at pediatric temporal bone CT

CT Quality Control Manual FAQs

Breast CT and Dosimetry

Introduction and Background

Radiation Exposure in Pregnancy. John R. Mayo UNIVERSITY OF BRITISH COLUMBIA

354 Korean J Radiol 9(4), August 2008

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

Handzettel 1. CT Contrast Media. Agenda. Contrast Media Definition. Agenda. Why we need contrast media? Agenda

SpiderX. Portable Residual Stress X-Ray Diffractometer.

Assessment of effective dose in paediatric CT examinations

Metal Artefact Reduction in CT

Dianna Cody, PhD, DABR, FAAPM Professor & Clinical Operations Director Imaging Physics U.T. M.D. Anderson Cancer Center Houston, TX

Recommendations for cross-sectional imaging in cancer management, Second edition

Modelling the effect of lead and other materials for shielding of the fetus in CT pulmonary angiography

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes

CT Dose Estimation. John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology. University of California Davis Medical Center

Electron Beam CT versus 16-slice Spiral CT: How Accurately Can We Measure. Coronary Artery Calcium Volume?

CT SCAN PROTOCOL. Shoulder

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

Transcription:

Estimating Iodine Concentration from CT Number Enhancement Rosemary Eaton, Andrew Shah, Jane Shekhdar Medical Physics, Mount Vernon Hospital CT Users Group 4 th October 212, Edinburgh

Summary Background to the project Phantom measurements: How is CT number related to iodine concentration? Anthropomorphic phantom measurements Conclusions

Background - SPUtNIk SPUtNIk project: Accuracy and Cost-Effectiveness of Dynamic Contrast Enhanced Computed Tomography in the Characterisation of Solitary Pulmonary Nodules Single Pulmonary Nodule Investigation

Background - SPUtNIk SPUtNIk project: Accuracy and Cost-Effectiveness of Dynamic Contrast Enhanced Computed Tomography in the Characterisation of Solitary Pulmonary Nodules Single pulmonary nodules -?malignant Dynamic contrast enhanced CT to assess vascularity Imaging pre-contrast and every 6s for 4 min ROI drawn (manually) over nodule at widest part in each series CT number plotted as a function of time Maximum enhancement over baseline Previous work: > 15HU (at 12 kv) positive for malignancy Swensen et al, Lung nodule enhancement at CT: multicentre study, Radiology 2; 214:73-8

SPUtNIk our concerns Can we use a lower kv to increase enhancement and improve ENR (enhancement to noise ratio)? Kalender et al (Med Phys 29; 36:993-17) show that CNRD is optimised at <6 kv for thorax imaging using iodine contrast, at a range of patient sizes Can we achieve adequate noise statistics at low kv, given the technical limitations on mas? Does the size of the patient affect measured CT number? Does the location of the ROI (eg in lung, next to a rib, near the heart) affect CT number?

How is CT number related to iodine concentration?

CT number vs [I] Iodine Optiray 35 contrast agent mixed with water Concentration determined by measuring mass Six iodine concentrations (.57 24.8 mg/ml) and water Expected concentration: 9 mg/ml in blood stream after complete mixing; threshold.6 mg/ml in nodule Scanner Siemens Somatom Definition 8, 1, 12 kv CT number of vials in air and surrounding Siemens QA phantom Vials scanned individually and adjacent to high iodine concentrations

Iodine in air 12 Mean enhancement in CT number over water (HU) 1 8 6 4 2 5 1 15 2 25 3 Iodine concentration (mg/ml) 8 kv, one vial at a time 8 kv, all vials together 12 kv, one vial at a time 12 kv, all vials together Linear (12 kv, one vial at a time) Linear (8 kv, all vials together) Linear (8 kv, one vial at a time) Linear (12 kv, all vials together)

Iodine next to water phantom 1 Mean enhancement in CT number over water (HU) 9 8 7 6 5 4 3 2 1 Graphs.. 8 kv 1 kv 12 kv Linear (12 kv) Linear (1 kv) Linear (8 kv) 5 1 15 2 25 3 Iodine concentration (mg/ml)

CT number vs [I] Gradient of CT number vs iodine concentration changes depending on what else is in the field of view Beam hardening effects More attenuation in the useful beam -> higher mean energy -> more penetrating -> material is less attenuating -> CT number is lower

Mean enhancement in CT number over water (HU) 12 1 8 6 4 2 8 kv, one vial at a time 8 kv, all vials together 12 kv, one vial at a time 12 kv, all vials together 8 kv, near water 1 kv, near water 12 kv, near water 5 1 15 2 25 3 Iodine concentration (mg/ml)

CT number vs [I] Our results compared to previous measurements Miles (27) found a significant variation between scanners AND over time Attributed to anode pitting and changes in effective filtration over time kv Medium CT no. to iodine ratio / HU (mg/ml) -1 This work Miles (27) 8 air 42. 38.8 8 water 36. 33.1 1 air 3.5 1 water 27.3 25.5 Miles (21) 12 air 26.8 25.6 26.5 12 chest 23.6 12 water 21.5 21.3 22.7 14 air 22.2 14 water 17.4 Miles, Young, Chica & Esser, Quantitative contrast-enhanced computed tomography: is there a need for system calibration?, Eur Radiol 27; 17:919-926 Miles, Griffiths & Fuentes, Standardised perfusion value: universal CT contrast enhancement scale that correlates with FDG PET in lung nodules, Radiology 21; 22:548-553

CT number vs [I] Our results compared to previous measurements Miles (27) found a significant variation between scanners AND over time Attributed to anode pitting and changes in effective filtration over time We will measure each scanner individually Lung-equivalent phantom with I inserts Radiographers will be provided with a water phantom with I inserts for consistency measurements over the timescale of the trial New tubes? kv Medium CT no. to iodine ratio / HU (mg/ml) -1 This work Miles (27) 8 air 42. 38.8 8 water 36. 33.1 1 air 3.5 1 water 27.3 25.5 Miles (21) 12 air 26.8 25.6 26.5 12 chest 23.6 12 water 21.5 21.3 22.7 14 air 22.2 14 water 17.4

Anthropomorphic phantom measurements

Phantom measurements Does the CT number depend on where in the lung the iodine is located? Does it depend on the size of the patient? Do these effects change with kv?

Method ART anthropomorphic phantom Thorax section Plugs removed in 3 locations: central lung; near rib; near heart 1 ml syringe filled with iodine solution and inserted into channels Two iodine solutions and water considered: 1. mg/ml,.6 mg/ml,. mg/ml Scanned at 8 kv, 1 kv, 12 kv Reduced FOV (15 cm) used in accordance with trial protocol Three different patient sizes : 5 kg, 8 kg, 95 kg

Method Images exported to CD and read with ImageJ ROI placed over central part of iodine solution ROI had to be moved manually as the phantom was not entirely straight and the ROI was small Inter-slice variation measurements made at 7 slices, ignoring gaps between phantom slabs Mean and SD in CT number recorded for each ROI nearly 2 measurements in total

Results 8 kv

Method Considered CT number enhancement, ie CT#(iodine) CT#(water) in same location. The CT number of water varied significantly depending on location in the phantom, phantom size and kv 7 Water CT number at 1 kv in small phantom 6 5 CT number (HU) 4 3 2 1 rib lung heart 1 12 14 16 18 2 22 24-1 Slice number

Method Considered CT number enhancement, ie CT#(iodine) CT#(water) in same location. The CT number of water varied significantly depending on location in the phantom, phantom size and kv Measuring enhancement more closely mimics the clinical situation where we are interested in increase in CT number compared to pre-contrast scan Excluded: slices between slabs of phantom air bubbles at ends of syringes slices at base of lung where diaphragm begins to appear Take mean of CT number enhancement in all remaining slices Students T-test (2-talied) to assess significance of differences in enhancement between different locations in phantom and different patient sizes (p<.5)

Results CT number varied with all parameters: kv Iodine concentration Following results are for 1. mg/ml Location within phantom Phantom size

4 35 12 kv 3 Results 8 kv 25 2 15 1 5 4 4 35 3 25 2 15 1 5 35 3 25 2 15 1 5

6 5 1 kv Results 8 kv 4 3 2 1 6 6 5 5 4 3 2 4 3 2 1 1

8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 kv

Analysis Enhancement is a bit erratic Generally: Enhancement slightly depressed near ribs beam hardening artefacts Enhancement near heart is variable beam hardening effects vs beam hardening correction? Enhancement in lung tissue near expected, except at 8 kv (high) Remember, considering enhancement not simply CT# Which kv should we use for the trial?

8 7 8 kv 6 Results 8 kv 5 4 3 2 1 Decided not to use 8 kv Statistically significant variation in enhancement, depending on location within phantom and phantom size 8 7 6 5 4 3 2 1 At 8 kv there is a significant difference in beam quality at different positions in the phantom Difficulties in obtaining high enough mas to keep noise low and ENR high for large patients 8 7 6 5 4 3 2 1

4 35 12 kv Results 8 kv 25 3 2 15 1 5 Decided against 12 kv too: Enhancement in the large phantom varied significantly between positions 4 4 35 3 25 2 15 1 5 Since enhancement values are lowest, a high dose needs to be delivered to obtain reasonable ENR (> 1.5?)* 35 3 25 2 15 1 5 *Miles et al Current status and guidelines for the assessment of tumour vascular support with dynamic contrast-enhanced computed tomography (Eur Radiol. 212; 22:143-1441), suggests ENR > 1.5.

6 5 1 kv Results 8 kv 4 3 2 1 We will use 1 kv in the SPUtNIk trial Least variation between phantoms and positions ENR > 1.5 at reasonable CTDI Threshold enhancement of 2 HU 6 6 5 5 4 3 2 Mass (kg) mas ENR CTDI (mgy) < 6 2 2.1 8.6 6 9 35 1.6 15.1 4 3 2 1 1 > 9 5 1.7 21.6

Analysis Limitations: Hard to know what patient mass our phantoms are ROI very small for 1ml syringes (area 5.9mm 2 / diameter 2.7mm). Nodules in trial will be >8mm, ROI drawn on widest axial slice at 7% nodule diameter on lung window Uncertainty in [I] and/or non-uniform distribution along syringe. Minimised by shaking our stock vial before drawing into the syringe Position of heart ROI in the heart itself for some slices, in the lung for others Since reduced FOV used, not sure what beam hardening correction is being applied. We will use a patient-size phantom with reduced FOV for the scanner assessments

Conclusions

Conclusions CT number does increase with increasing iodine concentration, but Need to use enhancementover baseline, rather than raw CT number Be aware of the limitationsand uncertaintyin enhancement measurements Think about what phantomto use to check the CT# / [I] for your scanner. Air? Water? Lung? The kvyou choose will depend on the application and required ENR All of these things will vary between scanners and recon kernels

Acknowledgements Maria Lewis (Guy s & St Thomas ) SPUtNIk trial group University of Southampton Clinical Trials Unit Project ref. 9/22/117

SPUtNIk Single Pulmonary Nodule Investigation Sites taking part in the trial: Aberdeen Brighton & Sussex Glasgow Mount Vernon Oxford Papworth Southampton UCH London

Thank you for listening Rosemary Eaton, Andrew Shah, Jane Shekhdar Medical Physics, Mount Vernon Hospital CT Users Group 4 th October 212, Edinburgh